Abstract

Purpose

The purpose of this study was to evaluate the surgical success of sulcus fixation of Baerveldt glaucoma implant (BGIs) in special reference to corneal damage.

Methods

This observational prospective cohort study included 24 patients who underwent a median of 3.0 previous intraocular surgeries and sulcus fixation of BGIs for the first time. The intraocular pressure (IOP), the number of ocular hypotensives used, corneal endothelial cell density (ECD), and logMAR-converted best-corrected visual acuity (VA) of each patient were measured preoperatively and postoperatively until 12 months after surgery. Surgical success was evaluated after 12 months based on the reduction of IOP (5–21 mmHg and > 20% reduction), corneal damage (postoperative development of decompensation, unmeasurable ECD, or ECD reduction of > 20%), loss of light perception, and need for additional surgeries.

Results

Surgical success was noted in 16 (66.7%) patients when corneal damage was included as a failure criterion, whereas surgery was successful in 21 (87.5%) patients when solely judged using IOP control similarly as previous clinical trials. The median IOP decreased from 27.5 mmHg preoperatively to 14.5 mmHg postoperatively (P < 0.0001). The number of ocular hypotensives was significantly reduced postoperatively (P < 0.0001). The median postoperative ECD reduction was only 0.15%, although ECD could not be measured during follow-up or it was significantly reduced by > 20% in six patients. VA was not significantly reduced after surgery. Adverse effects were observed in 15 patients (62.5 cumulative %).

Conclusion

Sulcus fixation of BGIs may be effective and safe in patients with glaucomatous eyes who underwent multiple prior intraocular surgeries.
Literature
3.
go back to reference Rumelt S, Rehany U (1998) Implantation of glaucoma drainage implant tube into the ciliary sulcus in patients with corneal transplants. Arch Ophthalmol 116:685–687CrossRefPubMed Rumelt S, Rehany U (1998) Implantation of glaucoma drainage implant tube into the ciliary sulcus in patients with corneal transplants. Arch Ophthalmol 116:685–687CrossRefPubMed
10.
go back to reference Heuer DK, Barton K, Grehn F et al (2008) Consensus on definitions of success. In: Shaarawy TM, Sherwood MB, Grehn F (eds) Guidelines on design and reporting of surgical trials. Kugler Publications, Amsterdam, pp 15–24 Heuer DK, Barton K, Grehn F et al (2008) Consensus on definitions of success. In: Shaarawy TM, Sherwood MB, Grehn F (eds) Guidelines on design and reporting of surgical trials. Kugler Publications, Amsterdam, pp 15–24
11.
go back to reference Topouzis F, Coleman AL, Choplin N, Bethlem MM, Hill R, Yu F, Panek WC, Wilson MR (1999) Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol 128:198–204CrossRefPubMed Topouzis F, Coleman AL, Choplin N, Bethlem MM, Hill R, Yu F, Panek WC, Wilson MR (1999) Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol 128:198–204CrossRefPubMed
18.
19.
go back to reference McDermott ML, Swendris RP, Shin DH, Juzych MS, Cowden JW (1993) Corneal endothelial cell counts after Molteno implantation. Am J Ophthalmol 115:93–96CrossRefPubMed McDermott ML, Swendris RP, Shin DH, Juzych MS, Cowden JW (1993) Corneal endothelial cell counts after Molteno implantation. Am J Ophthalmol 115:93–96CrossRefPubMed
21.
go back to reference Macdonald JM, Geroski DH, Edelhauser HF (1987) Effect of inflammation on the corneal endothelial pump and barrier. Curr Eye Res 6:1125–1132CrossRefPubMed Macdonald JM, Geroski DH, Edelhauser HF (1987) Effect of inflammation on the corneal endothelial pump and barrier. Curr Eye Res 6:1125–1132CrossRefPubMed
Metadata
Title
Effectiveness and safety of sulcus fixation of Baerveldt glaucoma implants in glaucomatous eyes in patients who underwent multiple intraocular surgeries
Authors
Sotaro Mori
Mari Sakamoto
Takuji Kurimoto
Akiyasu Kanamori
Kaori Ueda
Yukako Inoue
Yuko Yamada
Makoto Nakamura
Publication date
01-10-2018
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 10/2018
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-018-4044-3

Other articles of this Issue 10/2018

Graefe's Archive for Clinical and Experimental Ophthalmology 10/2018 Go to the issue