Skip to main content
Top
Published in: Lasers in Medical Science 1/2011

01-01-2011 | Original Article

Effect of sealants on laser fluorescence caries detection in primary teeth

Authors: Elina Askaroglou, Katerina Kavvadia, Panagiotis Lagouvardos, Lisa Papagiannoulis

Published in: Lasers in Medical Science | Issue 1/2011

Login to get access

Abstract

The aim of this study was to investigate in vitro the effects of clear or opaque sealants, on the laser fluorescence readings for occlusal caries detection in primary molars. For this reason, 427 occlusal sites in 199 teeth were clinically examined by one dentist, and their laser fluorescence (LF) was measured locally with the DIAGNOdent™ device, both before and after the teeth had been sealed with Delton Clear LC or Delton Opaque LC. For 29 of these teeth, we also measured the laser fluorescence by scanning the fissures before and after sealant application. We used Wilcoxon’s signed ranks sum test and Spearman’s rho correlation to compare and correlate the LF readings before and after sealing, while we used the Mann–Whitney U test to compare the two materials. Finally, we used the Kruskal–Wallis test to compare readings taken locally with those taken by the scanning technique. The results showed that there was an LF increase by a mean of 6 units after sealing with the clear material, while there was a 15 units decrease after sealing with the opaque one. LF readings before and after sealing correlated better for the clear material (rho = 0.826) than for the opaque one (rho = 0.507). LF readings were statistically significantly affected by both clear and opaque sealants (P < 0.001). However, this effect was statistically significantly less pronounced for the clear material (P < 0.001). There was also no difference between the LF readings taken by the fissure scanning technique or locally (P > 0.05). In conclusion, LF readings for occlusal caries detection in primary molars were significantly affected by both the clear and the opaque materials. However, the effect for the opaque material was more pronounced.
Literature
1.
go back to reference Ripa L (1982) Occlusal sealant: rational and review of clinical trials. Prev Dent 4:3–10 Ripa L (1982) Occlusal sealant: rational and review of clinical trials. Prev Dent 4:3–10
2.
go back to reference National Institutes of Health (1984) Consensus development conference statement on dental sealants in the prevention of tooth decay. J Am Dent Assoc 108:233–236 National Institutes of Health (1984) Consensus development conference statement on dental sealants in the prevention of tooth decay. J Am Dent Assoc 108:233–236
3.
go back to reference Anttonen V, Seppa L, Hausen H (2004) A follow-up study of the use of DIAGNOdent for monitoring fissure caries in children. Community Dent Oral Epidemiol 32:312–318CrossRefPubMed Anttonen V, Seppa L, Hausen H (2004) A follow-up study of the use of DIAGNOdent for monitoring fissure caries in children. Community Dent Oral Epidemiol 32:312–318CrossRefPubMed
4.
go back to reference Primosch R, Barr E (2001) Sealant use and placement techniques among pediatric dentists. J Am Dent Assoc 132:1442–1451PubMed Primosch R, Barr E (2001) Sealant use and placement techniques among pediatric dentists. J Am Dent Assoc 132:1442–1451PubMed
5.
go back to reference Deery C, Iloya J, Nugent Z, Srinivasan V (2006) Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: an in vitro study. Caries Res 40:186–193CrossRefPubMed Deery C, Iloya J, Nugent Z, Srinivasan V (2006) Effect of placing a clear sealant on the validity and reproducibility of occlusal caries detection by a laser fluorescence device: an in vitro study. Caries Res 40:186–193CrossRefPubMed
6.
go back to reference Bader J, Shugars D (2004) A systematic review of the performance of a laser fluorescence device for detecting caries. J Am Dent Assoc 135:1413–1426PubMed Bader J, Shugars D (2004) A systematic review of the performance of a laser fluorescence device for detecting caries. J Am Dent Assoc 135:1413–1426PubMed
7.
go back to reference Reis A, Mendes FM, Angnes V, Angnes G, Grande RH, Loguercio AD (2006) Performance of methods of occlusal caries detection in permanent teeth under clinical and laboratory conditions. J Dent 34:89–96CrossRefPubMed Reis A, Mendes FM, Angnes V, Angnes G, Grande RH, Loguercio AD (2006) Performance of methods of occlusal caries detection in permanent teeth under clinical and laboratory conditions. J Dent 34:89–96CrossRefPubMed
8.
go back to reference Lussi A, Reich E (2005) The influence of toothpastes and prophylaxis pastes on fluorescence measurements for caries detection in vitro. Eur J Oral Sci 113:141–144CrossRefPubMed Lussi A, Reich E (2005) The influence of toothpastes and prophylaxis pastes on fluorescence measurements for caries detection in vitro. Eur J Oral Sci 113:141–144CrossRefPubMed
9.
go back to reference Burin C, Cr B, Loguercio A, Grande R, Reis A (2005) Occlusal caries detection: a comparison of a laser fluorescence system and conventional methods. Pediatr Dent 27:307–312PubMed Burin C, Cr B, Loguercio A, Grande R, Reis A (2005) Occlusal caries detection: a comparison of a laser fluorescence system and conventional methods. Pediatr Dent 27:307–312PubMed
10.
go back to reference Anttonen V, Seppa L, Hausen H (2005) Clinical study on the effect of professional cleaning of occlusal tooth surfaces on laser fluorescence measurements. Caries Res 39:280–283CrossRefPubMed Anttonen V, Seppa L, Hausen H (2005) Clinical study on the effect of professional cleaning of occlusal tooth surfaces on laser fluorescence measurements. Caries Res 39:280–283CrossRefPubMed
11.
go back to reference Akarsu A, Koprulu H (2006) In vivo comparison of the efficacy of DIAGNOdent by visual inspection and radiographic diagnostic techniques in the diagnosis of occlusal caries. J Clin Dent 17:53–58PubMed Akarsu A, Koprulu H (2006) In vivo comparison of the efficacy of DIAGNOdent by visual inspection and radiographic diagnostic techniques in the diagnosis of occlusal caries. J Clin Dent 17:53–58PubMed
12.
go back to reference Olmez A, Tuna D, Oznurhan F (2006) Clinical evaluation of DIAGNOdent in detection of occlusal caries in children. J Clin Pediatr Dent 30:287–291PubMed Olmez A, Tuna D, Oznurhan F (2006) Clinical evaluation of DIAGNOdent in detection of occlusal caries in children. J Clin Pediatr Dent 30:287–291PubMed
13.
go back to reference Costa A, Bezzera A, Fuks A (2007) Assessment of the accuracy of visual examination, bite-wing radiographs and DIAGNOdent on the diagnosis of occlusal caries. Eur Arch Pediatr Dent 8:118–122 Costa A, Bezzera A, Fuks A (2007) Assessment of the accuracy of visual examination, bite-wing radiographs and DIAGNOdent on the diagnosis of occlusal caries. Eur Arch Pediatr Dent 8:118–122
14.
go back to reference Silva B, Severo N, Maltz M (2007) Validity of diode laser to monitor carious lesions in pits and fissures. J Dent 35:679–682CrossRefPubMed Silva B, Severo N, Maltz M (2007) Validity of diode laser to monitor carious lesions in pits and fissures. J Dent 35:679–682CrossRefPubMed
15.
go back to reference Attrill D, Ashley P (2001) Occlusal caries detection in primary teeth: a comparison of Diagnodent with conventional methods. Br Dent J 190:440–443PubMed Attrill D, Ashley P (2001) Occlusal caries detection in primary teeth: a comparison of Diagnodent with conventional methods. Br Dent J 190:440–443PubMed
16.
go back to reference Lussi A, Francescut P (2003) Performance of conventional and new methods for the detection of occlusal caries in deciduous teeth. Caries Res 37:2–7CrossRefPubMed Lussi A, Francescut P (2003) Performance of conventional and new methods for the detection of occlusal caries in deciduous teeth. Caries Res 37:2–7CrossRefPubMed
17.
go back to reference Francescut P, Lussi A (2003) Correlation between fissure discoloration, Diagnodent measurements, and caries depth: an in vitro study. Pediatr Dent 25:559–564PubMed Francescut P, Lussi A (2003) Correlation between fissure discoloration, Diagnodent measurements, and caries depth: an in vitro study. Pediatr Dent 25:559–564PubMed
18.
go back to reference Rocha R, Ardenghi T, Oliveira L, Rodrigues C, Ciamponi A (2003) In vivo effectiveness of laser fluorescence compared to visual inspection and radiography for the detection of occlusal caries in primary teeth. Caries Res 37:437–441CrossRefPubMed Rocha R, Ardenghi T, Oliveira L, Rodrigues C, Ciamponi A (2003) In vivo effectiveness of laser fluorescence compared to visual inspection and radiography for the detection of occlusal caries in primary teeth. Caries Res 37:437–441CrossRefPubMed
19.
go back to reference Anttonen V, Seppa L, Hausen H (2003) Clinical study of the use of the laser fluorescence device Diagnodent for the detection of occlusal caries in children. Caries Res 37:17–23CrossRefPubMed Anttonen V, Seppa L, Hausen H (2003) Clinical study of the use of the laser fluorescence device Diagnodent for the detection of occlusal caries in children. Caries Res 37:17–23CrossRefPubMed
20.
go back to reference Jeon R, Han C, Mandelis A, Sachez V, Abrams S (2004) Diagnosis of pit and fissure caries using frequency-domain infrared photothermal radiometry and modulated laser luminescence. Caries Res 38:497–513CrossRefPubMed Jeon R, Han C, Mandelis A, Sachez V, Abrams S (2004) Diagnosis of pit and fissure caries using frequency-domain infrared photothermal radiometry and modulated laser luminescence. Caries Res 38:497–513CrossRefPubMed
21.
go back to reference Mendes F, Hissadomi M, Imparato J (2004) Effects of drying time and the presence of plaque on the in vivo performance of laser fluorescence in occlusal caries of primary teeth. Caries Res 38:104–108CrossRefPubMed Mendes F, Hissadomi M, Imparato J (2004) Effects of drying time and the presence of plaque on the in vivo performance of laser fluorescence in occlusal caries of primary teeth. Caries Res 38:104–108CrossRefPubMed
22.
go back to reference Braga M, Mendes F, Imparato J, Martins C (2006) Effect of the calibration method of a laser fluorescence device for detecting occlusal caries in primary molars. Pediatr Dent 28:451–454PubMed Braga M, Mendes F, Imparato J, Martins C (2006) Effect of the calibration method of a laser fluorescence device for detecting occlusal caries in primary molars. Pediatr Dent 28:451–454PubMed
23.
go back to reference Kavvadia K, Lagouvardos P (2008) Clinical performance of a diode laser fluorescence device for the detection of occlusal caries in primary teeth. Int J Paediatr Dent 18:118–122CrossRef Kavvadia K, Lagouvardos P (2008) Clinical performance of a diode laser fluorescence device for the detection of occlusal caries in primary teeth. Int J Paediatr Dent 18:118–122CrossRef
24.
go back to reference Takamori K, Hokari N, Okumura Y, Watanabe S (2001) Detection of occlusal caries under sealants by use of a laser fluorescence system. J Clin Laser Med Surg 19:267–271CrossRefPubMed Takamori K, Hokari N, Okumura Y, Watanabe S (2001) Detection of occlusal caries under sealants by use of a laser fluorescence system. J Clin Laser Med Surg 19:267–271CrossRefPubMed
25.
go back to reference Hosoya Y, Matsuzaka K, Inoue T, Marshall G (2004) Influence of tooth-polishing pastes and sealants on DIAGNOdent values. Quintessence Int 35:605–611PubMed Hosoya Y, Matsuzaka K, Inoue T, Marshall G (2004) Influence of tooth-polishing pastes and sealants on DIAGNOdent values. Quintessence Int 35:605–611PubMed
26.
go back to reference Diniz MB, Rodrigues JA, Hug I, Cordeiro RCL, Lussi A (2008) The influence of pit and fissure sealants on infrared fluorescence measurements. Caries Res 42:328–333CrossRefPubMed Diniz MB, Rodrigues JA, Hug I, Cordeiro RCL, Lussi A (2008) The influence of pit and fissure sealants on infrared fluorescence measurements. Caries Res 42:328–333CrossRefPubMed
27.
go back to reference Krause F, Braun A, Frentzen M, Jepsen S (2008) Effects of composite fissure sealants on IR laser fluorescence measurements. Lasers Med Sci 23:133–139CrossRefPubMed Krause F, Braun A, Frentzen M, Jepsen S (2008) Effects of composite fissure sealants on IR laser fluorescence measurements. Lasers Med Sci 23:133–139CrossRefPubMed
28.
go back to reference Manton DJ, Messer LB (2007) The effect of pit and fissure sealants on the detection of occlusal caries in vitro. Eur Arch Paediatr Dent 8:43–48PubMed Manton DJ, Messer LB (2007) The effect of pit and fissure sealants on the detection of occlusal caries in vitro. Eur Arch Paediatr Dent 8:43–48PubMed
29.
go back to reference Nytun R, Raadal M, Espelid I (1992) Diagnosis of dentin involvement in occlusal caries based on visual and radiographic examination of teeth. Scand J Dent Res 100:144–148PubMed Nytun R, Raadal M, Espelid I (1992) Diagnosis of dentin involvement in occlusal caries based on visual and radiographic examination of teeth. Scand J Dent Res 100:144–148PubMed
30.
go back to reference Gostanian H, Shey Z, Kasinathan C, Caceda J, Janal M (2006) An in vitro evaluation of the effect of sealant characteristics on laser fluorescence for caries detection. Pediatr Dent 28:445–450PubMed Gostanian H, Shey Z, Kasinathan C, Caceda J, Janal M (2006) An in vitro evaluation of the effect of sealant characteristics on laser fluorescence for caries detection. Pediatr Dent 28:445–450PubMed
31.
go back to reference Hitij T, Fidler A (2008) Effect of dental material fluorescence on DIAGNOdent readings. Acta Odontol Scand 66:13–17CrossRefPubMed Hitij T, Fidler A (2008) Effect of dental material fluorescence on DIAGNOdent readings. Acta Odontol Scand 66:13–17CrossRefPubMed
32.
go back to reference Stach DJ, Hatch RA, Tilliss TSI, Cross-Poline GN (1992) Change in occlusal height resulting from placement of pit and fissure sealants. J Prosthet Dent 68:750–753CrossRefPubMed Stach DJ, Hatch RA, Tilliss TSI, Cross-Poline GN (1992) Change in occlusal height resulting from placement of pit and fissure sealants. J Prosthet Dent 68:750–753CrossRefPubMed
Metadata
Title
Effect of sealants on laser fluorescence caries detection in primary teeth
Authors
Elina Askaroglou
Katerina Kavvadia
Panagiotis Lagouvardos
Lisa Papagiannoulis
Publication date
01-01-2011
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 1/2011
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-009-0745-5

Other articles of this Issue 1/2011

Lasers in Medical Science 1/2011 Go to the issue