11-05-2024 | Original Article

Effect of plate orientation on apparent thickness of mineral plates by transmission electron microscopy

Authors: Henry Schwarcz, Chiara Micheletti, Kathryn Grandfield

Published in: Journal of Bone and Mineral Metabolism

Login to get access

Abstract

Purpose

Transmission electron microscopy (TEM) is widely used to study the ultrastructure of bone. The mineral of bone occurs as polycrystalline mineral plates about 3 to 6 nm in thickness. A problem in using TEM to make quantitative analyses of bone is that the orientation of the plates with respect to the plane of the section being imaged is expected to affect their apparent thickness. The purpose of this study was to test if this was true, if the apparent thickness of plates changed substantially as a result of tilt of the section.

Methods

We prepared TEM sections of samples of cortical human bone by ion beam milling, orienting one section parallel to the collagen fibril axes and one perpendicular to them. We obtained TEM bright field and HAADF images of these sections, tilting the sections up to ± 20° at 2° intervals and measuring the apparent thickness of individual mineral platelets at each angle of tilt.

Results

Thickness appears to double as section is tilted ± 20°. True thickness of plates is determined by tilting the section along an axis parallel to the plate orientation and determining the minimum apparent thickness. However, as plates are tilted away from minimum-thickness orientation, they become less well-resolved, disappearing when tilted more than 20°. We therefore also measured apparent thickness of only the darkest (most electron scattering) plate images in an untilted section and obtained the same average thickness as that obtained by tilting.

Conclusion

We conclude that tilting of the section is not necessary to obtain an accurate measurement of the thickness of mineral plates.
Literature
3.
go back to reference Nalla RK, Porter AE, Daraio C, Minor A, Radmilovic V, Stach E, Tomsia A, Ritchie R (2005) Ultrastructural examination of dentin using focused ion-beam cross-sectioning and transmission electron microscopy. Micron 36:672–680CrossRefPubMed Nalla RK, Porter AE, Daraio C, Minor A, Radmilovic V, Stach E, Tomsia A, Ritchie R (2005) Ultrastructural examination of dentin using focused ion-beam cross-sectioning and transmission electron microscopy. Micron 36:672–680CrossRefPubMed
Metadata
Title
Effect of plate orientation on apparent thickness of mineral plates by transmission electron microscopy
Authors
Henry Schwarcz
Chiara Micheletti
Kathryn Grandfield
Publication date
11-05-2024
Publisher
Springer Nature Singapore
Published in
Journal of Bone and Mineral Metabolism
Print ISSN: 0914-8779
Electronic ISSN: 1435-5604
DOI
https://doi.org/10.1007/s00774-024-01507-5
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine