Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | Research

Effect of filament types and loops number on the force degradation of elastomeric chains used for orthodontic treatment: an in-vitro study

Authors: Bowen Zheng, Majedh Abdo Ali Al-Somairi, Zhiyuan Li, Yang Zhao, Yi Liu

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

In orthodontic treatment, closing spaces, specifically the extraction and scattered spaces of the anterior teeth, requires some auxiliary bias, such as an elastomeric chain. Many factors affect the mechanical properties of elastic chains. In this study, we investigated the relationship of the filament type, the number of loops, and the force degradation of elastomeric chains under thermal cycling conditions.

Methods

The orthogonal design included three filament types (i.e., close, medium, and long). Four, five, and six loops of each elastomeric chain were stretched to have an initial force of 250 g in an artificial saliva environment at 37 °C and thermocycling between 5 and 55 °C three times a day. The remaining force of the elastomeric chains was recorded at different time points (4 h, 24 h, 7 days, 14 days, 21 days, and 28 days), and the percentage of the remaining force was calculated.

Results

The force decreased significantly in the initial 4 h and degraded mostly within the first 24 h. In addition, the percentage of force degradation increased slightly between 1 and 28 days.

Conclusions

Under the same initial force, the longer the connecting body is, the fewer the number of loops and the greater the force degradation of the elastomeric chain are.
Literature
1.
go back to reference Mirhashemi A, Saffarshahroudi A, Sodagar A, Atai M. Force-degradation pattern of six different orthodontic elastomeric chains. J Dent (Tehran). 2012;9(4):204–15.PubMed Mirhashemi A, Saffarshahroudi A, Sodagar A, Atai M. Force-degradation pattern of six different orthodontic elastomeric chains. J Dent (Tehran). 2012;9(4):204–15.PubMed
9.
go back to reference Ramachandraiah S, Sridharan K, Nishad A, Manjusha KK, Abraham EA, Ramees MM. Force decay characteristics of commonly used elastomeric chains on exposure to various mouth rinses with different alcohol concentration: an in vitro study. J Contemp Dent Pract. 2017;18:813–20.PubMed Ramachandraiah S, Sridharan K, Nishad A, Manjusha KK, Abraham EA, Ramees MM. Force decay characteristics of commonly used elastomeric chains on exposure to various mouth rinses with different alcohol concentration: an in vitro study. J Contemp Dent Pract. 2017;18:813–20.PubMed
20.
go back to reference Lo Giudice A, Portelli M, Militi A, et al. Is static friction affected by aging and amount of elastomeric ligatures in orthodontic sliding mechanics? an in-vitro investigation. J Biol Regul Homeost Agents. 2018;32:67–73.PubMed Lo Giudice A, Portelli M, Militi A, et al. Is static friction affected by aging and amount of elastomeric ligatures in orthodontic sliding mechanics? an in-vitro investigation. J Biol Regul Homeost Agents. 2018;32:67–73.PubMed
31.
go back to reference Sang T, Wu J. Factors on force degradation of elastomeric chains in vitro. Shanghai Kou Qiang Yi Xue. 2008;17:638–42. Sang T, Wu J. Factors on force degradation of elastomeric chains in vitro. Shanghai Kou Qiang Yi Xue. 2008;17:638–42.
Metadata
Title
Effect of filament types and loops number on the force degradation of elastomeric chains used for orthodontic treatment: an in-vitro study
Authors
Bowen Zheng
Majedh Abdo Ali Al-Somairi
Zhiyuan Li
Yang Zhao
Yi Liu
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-02812-7

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue