Published in: Journal of Clinical Monitoring and Computing 5/2020

01-10-2020 | Echocardiography | Original Research

Agreement between different non-invasive methods of ventricular elastance assessment for the monitoring of ventricular–arterial coupling in intensive care

Authors: Maxime Nguyen, Vivien Berhoud, Loïc Bartamian, Audrey Martin, Omar Ellouze, Bélaïd Bouhemad, Pierre-Grégoire Guinot

Published in: Journal of Clinical Monitoring and Computing | Issue 5/2020

Login to get access

Abstract

Ventricular–arterial coupling is calculated as the arterial elastance to end systolic elastance ratio (EA/Ees). Although the gold standard is invasive pressure volume loop analysis, Chen method is the clinical reference non-invasive method for estimating end systolic elastance (Ees). Several simplified methods calculate Ees from the end systolic pressure to volume ratio (ESP/ESV). The objective of the present study was to determine whether ESP/ESV simplification can be used instead of the Chen formula to measure ventricular–arterial coupling and to monitor changes following therapeutic intervention. In this retrospective, single-center study, 3 non-invasive EA/Ees calculation methods were applied to 86 cardiac ICU patients. The Chen method was used as the reference method. Ees was also calculated according to method 1: Ees1 = 0.9 × SAP/ESV and method 2: Ees2= EA/(1/LVEF) − 1. EA was estimated as 0.9 × SAP/SV (mmHg ml−1). After simplification: EA/Ees1 = EA/Ees2 = (1/LVEF) − 1, with the stroke volume estimated as the product of the aortic velocity–time integral (VTIAo) and the aortic area or as the difference between the end diastolic volume (EDV) and the ESV. All patients received fluid infusion, norepinephrine, or dobutamine. At baseline, the concordance correlation coefficient with EA/EesChen was 0.13 [− 0.07; 0.31] for EA/Ees1 and 0.32 [0.19; 0.44] for EA/Ees2. Bias and limit of agreement were 0.28 [− 0.02; 0.36] and [− 5.8; 2.6] for EA/Ees1 and of 0.44 [0.31; 0.53] and [− 3.2; 2.6] for EA/Ees2. When used to follow variations in EA/Ees following therapeutic interventions, only 65% (for EA/Ees1) and 70% (for EA/Ees2) of measures followed the same trend as EA/EesChen. Our results do not support the use of ESP/ESV based method as substitute for Chen method to measure and assess changes in ventriculo–arterial coupling (EA/Ees) in cardiac intensive care patients. Further investigations are needed to establish the most reliable non-invasive method.
Literature
12.
go back to reference Takeuchi M, Igarashi Y, Tomimoto S, et al. Single-beat estimation of the slope of the end-systolic pressure–volume relation in the human left ventricle. Circulation. 1991;83:202–12.CrossRef Takeuchi M, Igarashi Y, Tomimoto S, et al. Single-beat estimation of the slope of the end-systolic pressure–volume relation in the human left ventricle. Circulation. 1991;83:202–12.CrossRef
13.
go back to reference Senzaki H, Chen CH, Kass DA. Single-beat estimation of end-systolic pressure–volume relation in humans. A new method with the potential for noninvasive application. Circulation. 1996;94:2497–506.CrossRef Senzaki H, Chen CH, Kass DA. Single-beat estimation of end-systolic pressure–volume relation in humans. A new method with the potential for noninvasive application. Circulation. 1996;94:2497–506.CrossRef
14.
go back to reference Ikonomidis I, Aboyans V, Blacher J, et al. The role of ventricular–arterial coupling in cardiac disease and heart failure: assessment, clinical implications and therapeutic interventions. A consensus document of the European Society of Cardiology Working Group on Aorta & Peripheral Vascular Disease. Eur J Heart Fail. 2019;21:402–24. https://doi.org/10.1002/ejhf.1436.CrossRefPubMed Ikonomidis I, Aboyans V, Blacher J, et al. The role of ventricular–arterial coupling in cardiac disease and heart failure: assessment, clinical implications and therapeutic interventions. A consensus document of the European Society of Cardiology Working Group on Aorta & Peripheral Vascular Disease. Eur J Heart Fail. 2019;21:402–24. https://​doi.​org/​10.​1002/​ejhf.​1436.CrossRefPubMed
29.
go back to reference Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2015;16:233–71. https://doi.org/10.1093/ehjci/jev014.CrossRef Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2015;16:233–71. https://​doi.​org/​10.​1093/​ehjci/​jev014.CrossRef
Metadata
Title
Agreement between different non-invasive methods of ventricular elastance assessment for the monitoring of ventricular–arterial coupling in intensive care
Authors
Maxime Nguyen
Vivien Berhoud
Loïc Bartamian
Audrey Martin
Omar Ellouze
Bélaïd Bouhemad
Pierre-Grégoire Guinot
Publication date
01-10-2020
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 5/2020
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00397-7

Other articles of this Issue 5/2020

Journal of Clinical Monitoring and Computing 5/2020 Go to the issue