Skip to main content
Top
Published in: HSS Journal ® 1/2008

01-02-2008 | Original Article

Early Dislocation Rate in Ceramic-on-Ceramic Total Hip Arthroplasty

Authors: Kenny Mai, MD, Mary E. Hardwick, MSN, Richard H. Walker, MD, Steven N. Copp, MD, Kace A. Ezzet, MD, Clifford W. Colwell Jr., MD

Published in: HSS Journal ® | Issue 1/2008

Login to get access

Abstract

Wear debris from metal-on-polyethylene articulation in conventional total hip arthroplasty (THA) may limit THA longevity. Bearing surfaces made of modern ceramic material, with high wear resistance and low fracture risk, have the potential to extend the longevity of THA and make the procedure more suitable for young, active patients. Concerns regarding a ceramic-on-ceramic bearing surface have included potential for a higher incidence of dislocation caused by limited modular neck length and liner options. This prospective study assessed the early dislocation incidence for a ceramic-on-ceramic THA system. Out of the 336 consecutive ceramic-on-ceramic THA performed at our institution over an 8-year (1997–2005) period, 2 (0.6%) sustained dislocation during, and none after, the first postoperative year. Both dislocations were treated with closed reduction. No component fracture or revision for any reason has occurred in this series.
Literature
1.
go back to reference Jacobs JJ, Shanbhag A, Glant TT, et al (1994) Wear debris in total joint replacements. J Am Acad Orthop Surg 2:212–220PubMed Jacobs JJ, Shanbhag A, Glant TT, et al (1994) Wear debris in total joint replacements. J Am Acad Orthop Surg 2:212–220PubMed
2.
go back to reference Barrack RL, Burak C, Skinner HB (2004) Concerns about ceramics in THA. Clin Orthop Relat Res 429:73–79PubMedCrossRef Barrack RL, Burak C, Skinner HB (2004) Concerns about ceramics in THA. Clin Orthop Relat Res 429:73–79PubMedCrossRef
3.
go back to reference Phillips CB, Barrett JA, Losina E, et al (2003) Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement. J Bone Joint Surg Am 85:20–26PubMedCrossRef Phillips CB, Barrett JA, Losina E, et al (2003) Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement. J Bone Joint Surg Am 85:20–26PubMedCrossRef
4.
go back to reference Katz JN, Losina E, Barrett J, et al (2001) Association between hospital and surgeon procedure volume and outcomes of total hip replacement in the United States medicare population. J Bone Joint Surg Am 83:1622–1629PubMedCrossRef Katz JN, Losina E, Barrett J, et al (2001) Association between hospital and surgeon procedure volume and outcomes of total hip replacement in the United States medicare population. J Bone Joint Surg Am 83:1622–1629PubMedCrossRef
5.
go back to reference Garino JP (2000) Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res 379:41–47PubMedCrossRef Garino JP (2000) Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res 379:41–47PubMedCrossRef
6.
go back to reference Woo RY, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64:1295–1306PubMed Woo RY, Morrey BF (1982) Dislocations after total hip arthroplasty. J Bone Joint Surg Am 64:1295–1306PubMed
7.
go back to reference Mihalko WM, Whiteside LA (2004) Hip mechanics after posterior structure repair in total hip arthroplasty. Clin Orthop Relat Res 420:194–198PubMedCrossRef Mihalko WM, Whiteside LA (2004) Hip mechanics after posterior structure repair in total hip arthroplasty. Clin Orthop Relat Res 420:194–198PubMedCrossRef
8.
go back to reference Weeden SH, Paprosky WG, Bowling JW (2003) The early dislocation rate in primary total hip arthroplasty following the posterior approach with posterior soft-tissue repair. J Arthroplast 18:709–713CrossRef Weeden SH, Paprosky WG, Bowling JW (2003) The early dislocation rate in primary total hip arthroplasty following the posterior approach with posterior soft-tissue repair. J Arthroplast 18:709–713CrossRef
9.
go back to reference Boutin P (2000) Total hip arthroplasty using a ceramic prosthesis. Pierre Boutin (1924–1989). Clin Orthop Relat Res 379:3–11PubMedCrossRef Boutin P (2000) Total hip arthroplasty using a ceramic prosthesis. Pierre Boutin (1924–1989). Clin Orthop Relat Res 379:3–11PubMedCrossRef
10.
go back to reference Hamadouche M, Boutin P, Daussange J, et al (2002) Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84:69–77PubMed Hamadouche M, Boutin P, Daussange J, et al (2002) Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84:69–77PubMed
11.
go back to reference D’Antonio J, Capello W, Manley M, et al. (2005) Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 436:164–171PubMedCrossRef D’Antonio J, Capello W, Manley M, et al. (2005) Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 436:164–171PubMedCrossRef
12.
go back to reference Hannouche D, Hamadouche M, Nizard R, et al. (2005) Ceramics in total hip replacement. Clin Orthop Relat Res 430:62–71PubMedCrossRef Hannouche D, Hamadouche M, Nizard R, et al. (2005) Ceramics in total hip replacement. Clin Orthop Relat Res 430:62–71PubMedCrossRef
13.
go back to reference Sedel L (2000) Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res 379:48–54PubMedCrossRef Sedel L (2000) Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res 379:48–54PubMedCrossRef
14.
go back to reference Heros R, Willmann G (1998) Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty 9:114–122 Heros R, Willmann G (1998) Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty 9:114–122
15.
16.
go back to reference Pellicci PM, Bostrom M, Poss R (1998) Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin Orthop Relat Res 335:224–228CrossRef Pellicci PM, Bostrom M, Poss R (1998) Posterior approach to total hip replacement using enhanced posterior soft tissue repair. Clin Orthop Relat Res 335:224–228CrossRef
17.
go back to reference White RE, Jr, Forness TJ, Allman JK, et al (2001) Effect of posterior capsular repair on early dislocation in primary total hip replacement. Clin Orthop Relat Res 393:163–167PubMedCrossRef White RE, Jr, Forness TJ, Allman JK, et al (2001) Effect of posterior capsular repair on early dislocation in primary total hip replacement. Clin Orthop Relat Res 393:163–167PubMedCrossRef
18.
go back to reference Berry DJ, von Knoch M, Schleck CD, et al (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87:2456–2463PubMedCrossRef Berry DJ, von Knoch M, Schleck CD, et al (2005) Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am 87:2456–2463PubMedCrossRef
19.
go back to reference Bartz RL, Nobel PC, Kadakia NR, et al (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300–1307PubMed Bartz RL, Nobel PC, Kadakia NR, et al (2000) The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg Am 82:1300–1307PubMed
20.
go back to reference Chandler DR, Glousman R, Hull D, et al (1982) Prosthetic hip range of motion and impingement. The effects of head and neck geometry. Clin Orthop Relat Res 166:284–291PubMed Chandler DR, Glousman R, Hull D, et al (1982) Prosthetic hip range of motion and impingement. The effects of head and neck geometry. Clin Orthop Relat Res 166:284–291PubMed
21.
go back to reference Khatod M, Barber T, Paxton E, et al (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23PubMedCrossRef Khatod M, Barber T, Paxton E, et al (2006) An analysis of the risk of hip dislocation with a contemporary total joint registry. Clin Orthop Relat Res 447:19–23PubMedCrossRef
22.
go back to reference Fisher J, Jin Z, Tipper J, et al (2006) Tribology of alternative bearings. Clin Orthop Relat Res 453:25–34PubMedCrossRef Fisher J, Jin Z, Tipper J, et al (2006) Tribology of alternative bearings. Clin Orthop Relat Res 453:25–34PubMedCrossRef
Metadata
Title
Early Dislocation Rate in Ceramic-on-Ceramic Total Hip Arthroplasty
Authors
Kenny Mai, MD
Mary E. Hardwick, MSN
Richard H. Walker, MD
Steven N. Copp, MD
Kace A. Ezzet, MD
Clifford W. Colwell Jr., MD
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
HSS Journal ® / Issue 1/2008
Print ISSN: 1556-3316
Electronic ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-007-9060-5

Other articles of this Issue 1/2008

HSS Journal ® 1/2008 Go to the issue

Cases in Peri-Operative Medicine

Pulmonary Embolism after IVC Filter