Skip to main content
Top
Published in: Clinical Oral Investigations 8/2017

01-11-2017 | Original Article

Early bone formation around immediately loaded implants with nanostructured calcium-incorporated and machined surface: a randomized, controlled histologic and histomorphometric study in the human posterior maxilla

Authors: Francesco Guido Mangano, Giovanna Iezzi, Jamil Awad Shibli, Jefferson Trabach Pires, Giuseppe Luongo, Adriano Piattelli, Carlo Mangano

Published in: Clinical Oral Investigations | Issue 8/2017

Login to get access

Abstract

Objective

The aim of this randomized, controlled histologic/histomorphometric study was to compare the early bone formation around immediately loaded implants with nanostructured calcium-incorporated (NCI) and machined (MA) surface, placed in the human posterior maxilla.

Materials and methods

Fifteen fully edentulous patients (six males; nine females; mean age 57.9 ± 6.7 years) were selected for this study. Each patient was installed with two temporary transmucosal implants, with different surfaces: one NCI (test) and one MA (control) implant. All temporary implants were placed in the posterior maxilla, according to a split-mouth design, to help to support an interim complete maxillary denture. After 8 weeks, all temporary transmucosal implants were retrieved for histologic/histomorphometric evaluation. The bone-to-implant contact (BIC%) and the bone density (BD%) were calculated. The Wilcoxon matched-pairs signed-rank test was used to evaluate differences (BIC%, BD%) between the surfaces. The level of significance was set at 0.05.

Results

Eight weeks after placement, 24 clinically stable implants (12 test, 12 control) were subjected to histologic/histomorphometric evaluation. In the MA implants, the histomorphometric evaluation revealed a mean BIC(±SD)% and BD(±SD)% of 21.2(±4.9)% and 29.8(±7.8)%, respectively. In the NCI implants, the histomorphometric analysis revealed a mean BIC(±SD)% and BD(±SD)% of 39.7(±8.7)% and 34.6(±7.2)%, respectively. A statistically significant difference was found between the two surfaces with regard to BIC% (p < 0.001), while no significant difference was found with regard to BD% (p = 0.09).

Conclusions

The NCI surface seems to increase the peri-implant endosseous healing properties in the native bone of the posterior maxilla, under immediate loading conditions, when compared with the MA surface.

Clinical relevance

Under immediate loading conditions in the human posterior maxilla, the nanostructured calcium-incorporated surface has led to better histologic and histomorphometric results than the machined surface; therefore, the clinical use of implants with nanostructured calcium-incorporated surface may be beneficial in the posterior maxilla, under immediate loading protocol.
Literature
1.
go back to reference Degidi M, Nardi D, Piattelli A (2016) 10-year prospective cohort follow-up of immediately restored XiVE implants. Clin Oral Implants Res 27:694–700CrossRefPubMed Degidi M, Nardi D, Piattelli A (2016) 10-year prospective cohort follow-up of immediately restored XiVE implants. Clin Oral Implants Res 27:694–700CrossRefPubMed
2.
go back to reference Suarez F, Chan HL, Monje A, Galindo-Moreno P, Wang HL (2013) Effect of the timing of restoration on implant marginal bone loss: a systematic review. J Periodontol 84:159–169CrossRefPubMed Suarez F, Chan HL, Monje A, Galindo-Moreno P, Wang HL (2013) Effect of the timing of restoration on implant marginal bone loss: a systematic review. J Periodontol 84:159–169CrossRefPubMed
3.
go back to reference Papaspyridakos P, Chen CJ, Chuang SK, Weber HP (2014) Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 29(Suppl):256–270CrossRefPubMed Papaspyridakos P, Chen CJ, Chuang SK, Weber HP (2014) Implant loading protocols for edentulous patients with fixed prostheses: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 29(Suppl):256–270CrossRefPubMed
4.
go back to reference Benic GI, Mir-Mari J, Hämmerle CH (2014) Loading protocols for single-implant crowns: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 29(Suppl):222–238CrossRefPubMed Benic GI, Mir-Mari J, Hämmerle CH (2014) Loading protocols for single-implant crowns: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 29(Suppl):222–238CrossRefPubMed
5.
go back to reference Barbier L, Abeloos J, De Clercq C, Jacobs R (2012) Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla. Clin Oral Investig 16:1061–1070CrossRefPubMed Barbier L, Abeloos J, De Clercq C, Jacobs R (2012) Peri-implant bone changes following tooth extraction, immediate placement and loading of implants in the edentulous maxilla. Clin Oral Investig 16:1061–1070CrossRefPubMed
6.
go back to reference Luongo G, Lenzi C, Raes F, Eccellente T, Ortolani M, Mangano C (2014) Immediate functional loading of single implants: a 1-year interim report of a 5-year prospective multicentre study. Eur J Oral Implantol 7:187–199PubMed Luongo G, Lenzi C, Raes F, Eccellente T, Ortolani M, Mangano C (2014) Immediate functional loading of single implants: a 1-year interim report of a 5-year prospective multicentre study. Eur J Oral Implantol 7:187–199PubMed
7.
go back to reference Farronato D, Mangano F, Briguglio F, Iorio-Siciliano V, Riccitiello F, Guarnieri R (2014) Influence of Laser-Lok surface on immediate functional loading of implants in single-tooth replacement: a 2-year prospective clinical study. Int J Periodontics Restorative Dent 34:79–89CrossRefPubMed Farronato D, Mangano F, Briguglio F, Iorio-Siciliano V, Riccitiello F, Guarnieri R (2014) Influence of Laser-Lok surface on immediate functional loading of implants in single-tooth replacement: a 2-year prospective clinical study. Int J Periodontics Restorative Dent 34:79–89CrossRefPubMed
8.
go back to reference Dohan Ehrenfest DM, Vazquez L, Park YJ, Sammartino G, Bernard JP (2011) Identification card and codification of the chemical and morphological characteristics of 14 dental implant surfaces. J Oral Implantol 37:525–542CrossRefPubMed Dohan Ehrenfest DM, Vazquez L, Park YJ, Sammartino G, Bernard JP (2011) Identification card and codification of the chemical and morphological characteristics of 14 dental implant surfaces. J Oral Implantol 37:525–542CrossRefPubMed
9.
go back to reference Chrcanovic BR, Albrektsson T, Wennerberg A (2014) Immediate non-functional versus immediate functional loading and dental implant failure rates: a systematic review and meta-analysis. J Dent 42:1052–1059CrossRefPubMed Chrcanovic BR, Albrektsson T, Wennerberg A (2014) Immediate non-functional versus immediate functional loading and dental implant failure rates: a systematic review and meta-analysis. J Dent 42:1052–1059CrossRefPubMed
10.
go back to reference Calvo-Guirado JL, Satorres-Nieto M, Aguilar-Salvatierra A, Delgado-Ruiz RA, Maté-Sánchez de Val JE, Gargallo-Albiol J, Gómez-Moreno G, Romanos GE (2015) Influence of surface treatment on osseointegration of dental implants: histological, histomorphometric and radiological analysis in vivo. Clin Oral Investig 19:509–517CrossRefPubMed Calvo-Guirado JL, Satorres-Nieto M, Aguilar-Salvatierra A, Delgado-Ruiz RA, Maté-Sánchez de Val JE, Gargallo-Albiol J, Gómez-Moreno G, Romanos GE (2015) Influence of surface treatment on osseointegration of dental implants: histological, histomorphometric and radiological analysis in vivo. Clin Oral Investig 19:509–517CrossRefPubMed
11.
go back to reference Buser D, Janner SF, Wittneben JG, Brägger U, Ramseier CA, Salvi GE (2012) 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res 14:839–851CrossRefPubMed Buser D, Janner SF, Wittneben JG, Brägger U, Ramseier CA, Salvi GE (2012) 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res 14:839–851CrossRefPubMed
12.
go back to reference Wennerberg A, Albrektsson T (2009) Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 20(Suppl 4):172–184CrossRefPubMed Wennerberg A, Albrektsson T (2009) Effects of titanium surface topography on bone integration: a systematic review. Clin Oral Implants Res 20(Suppl 4):172–184CrossRefPubMed
13.
go back to reference Feller L, Jadwat Y, Khammissa RA, Meyerov R, Schechter I, Lemmer J (2015) Cellular responses evoked by different surface characteristics of intraosseous titanium implants. Biomed Res Int 2015:171945CrossRefPubMedPubMedCentral Feller L, Jadwat Y, Khammissa RA, Meyerov R, Schechter I, Lemmer J (2015) Cellular responses evoked by different surface characteristics of intraosseous titanium implants. Biomed Res Int 2015:171945CrossRefPubMedPubMedCentral
14.
go back to reference Kokubo T, Yamaguchi S (2015) Growth of novel ceramic layers on metals via chemical and heat treatments for inducing various biological functions. Front Bioeng Biotechno 3:176 11 pages Kokubo T, Yamaguchi S (2015) Growth of novel ceramic layers on metals via chemical and heat treatments for inducing various biological functions. Front Bioeng Biotechno 3:176 11 pages
15.
go back to reference Traini T, Murmura G, Piattelli M, Scarano A, Pettinicchio M, Sinjari B, Caputi S (2013) Effect of nanoscale topography of titanium implants on bone vessel network, osteocytes, and mineral densities. J Periodontol 84:e40–e47CrossRefPubMed Traini T, Murmura G, Piattelli M, Scarano A, Pettinicchio M, Sinjari B, Caputi S (2013) Effect of nanoscale topography of titanium implants on bone vessel network, osteocytes, and mineral densities. J Periodontol 84:e40–e47CrossRefPubMed
16.
go back to reference Mendes VC, Moineddin R, Davies JE (2007) The effect of discrete calcium phosphate nanocrystals on bone-bonding to titanium surfaces. Biomaterials 28:4748–4755CrossRefPubMed Mendes VC, Moineddin R, Davies JE (2007) The effect of discrete calcium phosphate nanocrystals on bone-bonding to titanium surfaces. Biomaterials 28:4748–4755CrossRefPubMed
17.
go back to reference Abrahamsson I, Linder E, Larsson L, Berglundh T (2013) Deposition of nanometer scaled calcium-phosphate crystals to implants with a dual acid-etched surface does not improve early tissue integration. Clin Oral Implants Res 24:57–62CrossRefPubMed Abrahamsson I, Linder E, Larsson L, Berglundh T (2013) Deposition of nanometer scaled calcium-phosphate crystals to implants with a dual acid-etched surface does not improve early tissue integration. Clin Oral Implants Res 24:57–62CrossRefPubMed
18.
go back to reference Park YS, Yi KY, Lee IS, Han CH, Jung YC (2005) The effects of ion beam assisted deposition of hydroxyapatite on the grit blasted surface of endosseous implants in rat tibiae. Int J Oral Maxillofac Implants 20:31–38PubMed Park YS, Yi KY, Lee IS, Han CH, Jung YC (2005) The effects of ion beam assisted deposition of hydroxyapatite on the grit blasted surface of endosseous implants in rat tibiae. Int J Oral Maxillofac Implants 20:31–38PubMed
19.
go back to reference Coelho PG, Cardaropoli G, Suzuki M, Lemons JE (2009) Early healing of nanothickness bioceramic coatings on dental implants. An experimental study in dogs. J Biomed Mater Res B Applied Biomaterials 88:387–393CrossRef Coelho PG, Cardaropoli G, Suzuki M, Lemons JE (2009) Early healing of nanothickness bioceramic coatings on dental implants. An experimental study in dogs. J Biomed Mater Res B Applied Biomaterials 88:387–393CrossRef
20.
go back to reference Marin C, Granato R, Suzuki M, Gil GN, Piattelli A, Coelho PG (2008) Removal torque and histomorphometric evaluation of bioceramic grit blasted/acid etched and dual acid etched implant surfaces. An experimental study in dogs. J Periodontol 79:1942–1949CrossRefPubMed Marin C, Granato R, Suzuki M, Gil GN, Piattelli A, Coelho PG (2008) Removal torque and histomorphometric evaluation of bioceramic grit blasted/acid etched and dual acid etched implant surfaces. An experimental study in dogs. J Periodontol 79:1942–1949CrossRefPubMed
21.
go back to reference Lee SY, Yang DJ, Yeo S, An HW, Ryoo KH, Park KB (2012) The cytocompatibility and osseointegration of the Ti implants with XPEED® surfaces. Clin Oral Implants Res 23:1283–1289CrossRefPubMed Lee SY, Yang DJ, Yeo S, An HW, Ryoo KH, Park KB (2012) The cytocompatibility and osseointegration of the Ti implants with XPEED® surfaces. Clin Oral Implants Res 23:1283–1289CrossRefPubMed
22.
go back to reference Shibli JA, Mangano C, Mangano F, Rodrigues JA, Cassoni A, Bechara K, Ferreia JD, Dottore AM, Iezzi G, Piattelli A (2013) Bone-to-implant contact around immediately loaded direct laser metal-forming transitional implants in human posterior maxilla. J Periodontol 84:732–737CrossRefPubMed Shibli JA, Mangano C, Mangano F, Rodrigues JA, Cassoni A, Bechara K, Ferreia JD, Dottore AM, Iezzi G, Piattelli A (2013) Bone-to-implant contact around immediately loaded direct laser metal-forming transitional implants in human posterior maxilla. J Periodontol 84:732–737CrossRefPubMed
23.
go back to reference Froum SJ, Simon H, Cho SC, Elian N, Rohrer MD, Tarnow DP (2005) Histologic evaluation of bone implant contact of immediately loaded transitional implants after 6 to 27 months. Int J Oral Maxillofac Implants 20:54–60PubMed Froum SJ, Simon H, Cho SC, Elian N, Rohrer MD, Tarnow DP (2005) Histologic evaluation of bone implant contact of immediately loaded transitional implants after 6 to 27 months. Int J Oral Maxillofac Implants 20:54–60PubMed
24.
go back to reference Romanos GE, Traini T, Johansson CB, Piattelli A (2010) Biologic width and morphologic characteristics of soft tissues around immediately loaded implants: studies performed on human autopsy specimens. J Periodontol 81:70–78CrossRefPubMed Romanos GE, Traini T, Johansson CB, Piattelli A (2010) Biologic width and morphologic characteristics of soft tissues around immediately loaded implants: studies performed on human autopsy specimens. J Periodontol 81:70–78CrossRefPubMed
25.
go back to reference Romanos GE (2015) Wound healing in immediately loaded implants. Periodontology 2000(68):153–167CrossRef Romanos GE (2015) Wound healing in immediately loaded implants. Periodontology 2000(68):153–167CrossRef
26.
go back to reference Östman PO, Wennerberg A, Ekestubbe A, Albrektsson T (2013) Immediate occlusal loading of NanoTite™ tapered implants: a prospective 1-year clinical and radiographic study. Clin Implant Dent Relat Res 15:809–818CrossRefPubMed Östman PO, Wennerberg A, Ekestubbe A, Albrektsson T (2013) Immediate occlusal loading of NanoTite™ tapered implants: a prospective 1-year clinical and radiographic study. Clin Implant Dent Relat Res 15:809–818CrossRefPubMed
27.
go back to reference Telleman G, Meijer HJ, Vissink A, Raghoebar GM (2013) Short implants with a nanometer-sized CaP surface provided with either a platform-switched or platform-matched abutment connection in the posterior region: a randomized clinical trial. Clin Oral Implants Res 24:1316–1324CrossRefPubMed Telleman G, Meijer HJ, Vissink A, Raghoebar GM (2013) Short implants with a nanometer-sized CaP surface provided with either a platform-switched or platform-matched abutment connection in the posterior region: a randomized clinical trial. Clin Oral Implants Res 24:1316–1324CrossRefPubMed
28.
go back to reference Pistilli R, Felice P, Piattelli M, Gessaroli M, Soardi E, Barausse C, Buti J, Corvino V (2013) Posterior atrophic jaws rehabilitated with prostheses supported by 5 × 5 mm implants with a novel nanostructured calcium-incorporated titanium surface or by longer implants in augmented bone. One-year results from a randomised controlled trial. Eur J Oral Implantol 6:343–357PubMed Pistilli R, Felice P, Piattelli M, Gessaroli M, Soardi E, Barausse C, Buti J, Corvino V (2013) Posterior atrophic jaws rehabilitated with prostheses supported by 5 × 5 mm implants with a novel nanostructured calcium-incorporated titanium surface or by longer implants in augmented bone. One-year results from a randomised controlled trial. Eur J Oral Implantol 6:343–357PubMed
29.
go back to reference Felice P, Grusovin MG, Barausse C, Grandi G, Esposito M (2015) Safety and effectiveness of early loaded maxillary titanium implants with a novel nanostructured calcium-incorporated surface (Xpeed): 3-year results from a pilot multicenter randomised controlled trial. Eur J Oral Implantol 8:245–254PubMed Felice P, Grusovin MG, Barausse C, Grandi G, Esposito M (2015) Safety and effectiveness of early loaded maxillary titanium implants with a novel nanostructured calcium-incorporated surface (Xpeed): 3-year results from a pilot multicenter randomised controlled trial. Eur J Oral Implantol 8:245–254PubMed
30.
go back to reference Goene RJ, Testori T, Trisi P (2007) Influence of a nanometer scale surface enhancement on de novo bone formation on titanium implants: a histomorphometric study in human maxillae. Int J Periodontics Restorative Dent 27:211–219PubMed Goene RJ, Testori T, Trisi P (2007) Influence of a nanometer scale surface enhancement on de novo bone formation on titanium implants: a histomorphometric study in human maxillae. Int J Periodontics Restorative Dent 27:211–219PubMed
31.
go back to reference Orsini G, Piattelli M, Scarano A, Petrone G, Kenealy J, Piattelli A, Caputi S (2007) Randomized, controlled histologic and histomorphometric evaluation of implants with nanometer-scale calcium phosphate added to the dual acid-etched surface in the human posterior maxilla. J Periodontol 78:209–218CrossRefPubMed Orsini G, Piattelli M, Scarano A, Petrone G, Kenealy J, Piattelli A, Caputi S (2007) Randomized, controlled histologic and histomorphometric evaluation of implants with nanometer-scale calcium phosphate added to the dual acid-etched surface in the human posterior maxilla. J Periodontol 78:209–218CrossRefPubMed
32.
go back to reference Telleman G, Albrektsson T, Hoffman M, Johansson CB, Vissink A, Meijer HJ, Raghoebar GM (2010) Peri-implant endosseous healing properties of dual acid-etched mini-implants with a nanometer-sized deposition of CaP: a histological and histomorphometric human study. Clin Implant Dent Relat Res 12:153–160CrossRefPubMed Telleman G, Albrektsson T, Hoffman M, Johansson CB, Vissink A, Meijer HJ, Raghoebar GM (2010) Peri-implant endosseous healing properties of dual acid-etched mini-implants with a nanometer-sized deposition of CaP: a histological and histomorphometric human study. Clin Implant Dent Relat Res 12:153–160CrossRefPubMed
33.
go back to reference Shibli JA, Grassi S, Piattelli A, Pecora GE, Ferrari DS, Onuma T, d'Avila S, Coelho PG, Barros R, Iezzi G (2010) Histomorphometric evaluation of bioceramic molecular impregnated and dual acid-etched implant surfaces in the human posterior maxilla. Clin Implant Dent Relat Res 12:281–288CrossRefPubMed Shibli JA, Grassi S, Piattelli A, Pecora GE, Ferrari DS, Onuma T, d'Avila S, Coelho PG, Barros R, Iezzi G (2010) Histomorphometric evaluation of bioceramic molecular impregnated and dual acid-etched implant surfaces in the human posterior maxilla. Clin Implant Dent Relat Res 12:281–288CrossRefPubMed
34.
go back to reference Raes S, Raes F, Cooper L, Giner Tarrida L, Vervaeke S, Cosyn J, De Bruyn H (2016) Oral health-related quality of life changes after placement of immediately loaded single implants in healed alveolar ridges or extraction sockets: a 5-year prospective follow-up study. Clin Oral Implants Res. doi:10.1111/clr.12858 Raes S, Raes F, Cooper L, Giner Tarrida L, Vervaeke S, Cosyn J, De Bruyn H (2016) Oral health-related quality of life changes after placement of immediately loaded single implants in healed alveolar ridges or extraction sockets: a 5-year prospective follow-up study. Clin Oral Implants Res. doi:10.​1111/​clr.​12858
35.
go back to reference Barndt P, Zhang H, Liu F (2015) Immediate loading: from biology to biomechanics. Report of the Committee on Research in fixed Prosthodontics of the American Academy of fixed Prosthodontics. J Prosthet Dent 113:96–107CrossRefPubMed Barndt P, Zhang H, Liu F (2015) Immediate loading: from biology to biomechanics. Report of the Committee on Research in fixed Prosthodontics of the American Academy of fixed Prosthodontics. J Prosthet Dent 113:96–107CrossRefPubMed
36.
go back to reference Mangano FG, Luongo F, Picciocchi G, Mortellaro C, Park KB, Mangano C (2016) Soft tissue stability around single implants inserted to replace maxillary lateral incisors: a 3D evaluation. Int J Dent 2016:9393219PubMedPubMedCentral Mangano FG, Luongo F, Picciocchi G, Mortellaro C, Park KB, Mangano C (2016) Soft tissue stability around single implants inserted to replace maxillary lateral incisors: a 3D evaluation. Int J Dent 2016:9393219PubMedPubMedCentral
37.
go back to reference Han CH, Mangano F, Mortellaro C, Park KB (2016) Immediate loading of tapered implants placed in postextraction sockets and healed sites: a prospective study with 1 year of follow-up. J Craniofac Surg 27:1220–1227 Han CH, Mangano F, Mortellaro C, Park KB (2016) Immediate loading of tapered implants placed in postextraction sockets and healed sites: a prospective study with 1 year of follow-up. J Craniofac Surg 27:1220–1227
38.
go back to reference Sağirkaya E, Kucukekenci AS, Karasoy D, Akça K, Eckert SE, Çehreli MC (2013) Comparative assessments, meta-analysis, and recommended guidelines for reporting studies on histomorphometric bone-implant contact in humans. Int J Oral Maxillofac Implants 28:1243–1253CrossRefPubMed Sağirkaya E, Kucukekenci AS, Karasoy D, Akça K, Eckert SE, Çehreli MC (2013) Comparative assessments, meta-analysis, and recommended guidelines for reporting studies on histomorphometric bone-implant contact in humans. Int J Oral Maxillofac Implants 28:1243–1253CrossRefPubMed
39.
go back to reference Texeira ER, Torres MA, Meyer KR, Zani SR, Shinkai RS, Grossi ML (2015) The influence of low-level laser on osseointegration around machined and sandblasted acid-etched implants: a removal torque and histomorphometric analyses. J Oral Implantol 41:407–413CrossRef Texeira ER, Torres MA, Meyer KR, Zani SR, Shinkai RS, Grossi ML (2015) The influence of low-level laser on osseointegration around machined and sandblasted acid-etched implants: a removal torque and histomorphometric analyses. J Oral Implantol 41:407–413CrossRef
40.
go back to reference Kim JR, Kim SH, Kim IR, Park BS, Kim YD (2016) Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits. J Korean Assoc Oral Maxillofac Surg 42:2–8CrossRefPubMedPubMedCentral Kim JR, Kim SH, Kim IR, Park BS, Kim YD (2016) Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits. J Korean Assoc Oral Maxillofac Surg 42:2–8CrossRefPubMedPubMedCentral
Metadata
Title
Early bone formation around immediately loaded implants with nanostructured calcium-incorporated and machined surface: a randomized, controlled histologic and histomorphometric study in the human posterior maxilla
Authors
Francesco Guido Mangano
Giovanna Iezzi
Jamil Awad Shibli
Jefferson Trabach Pires
Giuseppe Luongo
Adriano Piattelli
Carlo Mangano
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 8/2017
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-017-2061-y

Other articles of this Issue 8/2017

Clinical Oral Investigations 8/2017 Go to the issue