Skip to main content
Top
Published in: European Journal of Nuclear Medicine and Molecular Imaging 4/2008

01-04-2008 | Guidelines

EANM/ESC guidelines for radionuclide imaging of cardiac function

Authors: B. Hesse, T. B. Lindhardt, W. Acampa, C. Anagnostopoulos, J. Ballinger, J. J. Bax, L. Edenbrandt, A. Flotats, G. Germano, T. Gmeiner Stopar, P. Franken, A. Kelion, A. Kjaer, D. Le Guludec, M. Ljungberg, A. F. Maenhout, C. Marcassa, J. Marving, F. McKiddie, W. M. Schaefer, L. Stegger, R. Underwood

Published in: European Journal of Nuclear Medicine and Molecular Imaging | Issue 4/2008

Login to get access

Abstract

Radionuclide imaging of cardiac function represents a number of well-validated techniques for accurate determination of right (RV) and left ventricular (LV) ejection fraction (EF) and LV volumes. These first European guidelines give recommendations for how and when to use first-pass and equilibrium radionuclide ventriculography, gated myocardial perfusion scintigraphy, gated PET, and studies with non-imaging devices for the evaluation of cardiac function. The items covered are presented in 11 sections: clinical indications, radiopharmaceuticals and dosimetry, study acquisition, RV EF, LV EF, LV volumes, LV regional function, LV diastolic function, reports and image display and reference values from the literature of RVEF, LVEF and LV volumes. If specific recommendations given cannot be based on evidence from original, scientific studies, referral is given to “prevailing or general consensus”. The guidelines are designed to assist in the practice of referral to, performance, interpretation and reporting of nuclear cardiology studies for the evaluation of cardiac performance.
Literature
1.
go back to reference White HD, Norris RM, Brown MA, Takayama M, Maslowski A, Bass NM, et al. Effect of intravenous streptokinase on left ventricular function and early survival after acute myocardial infarction. N Engl J Med 1987;317:850-5.PubMedCrossRef White HD, Norris RM, Brown MA, Takayama M, Maslowski A, Bass NM, et al. Effect of intravenous streptokinase on left ventricular function and early survival after acute myocardial infarction. N Engl J Med 1987;317:850-5.PubMedCrossRef
2.
go back to reference Mahmarian JJ, Shaw LJ, Filipchuk NG, Dakik HA, Iskander SS, Ruddy TD, et al. A multinational study to establish the value of early adenosine technetium-99m sestamibi myocardial perfusion SPECT in identifying a low-risk group for early hospital discharge after acute myocardial infarction. J Am Coll Cardiol 2006;48:2448-57.PubMedCrossRef Mahmarian JJ, Shaw LJ, Filipchuk NG, Dakik HA, Iskander SS, Ruddy TD, et al. A multinational study to establish the value of early adenosine technetium-99m sestamibi myocardial perfusion SPECT in identifying a low-risk group for early hospital discharge after acute myocardial infarction. J Am Coll Cardiol 2006;48:2448-57.PubMedCrossRef
3.
go back to reference Schaadt B, Kelbaek H. Age and left ventricular ejection fraction identify patients with advanced breast cancer at high risk for development of epirubicin-induced heart failure. J Nucl Cardiol 1997;4:494-501.PubMedCrossRef Schaadt B, Kelbaek H. Age and left ventricular ejection fraction identify patients with advanced breast cancer at high risk for development of epirubicin-induced heart failure. J Nucl Cardiol 1997;4:494-501.PubMedCrossRef
4.
go back to reference Klocke FJ, Baird MG, Bateman TM, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging—executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). J Am Coll Cardiol 2003;42:1318-33.PubMedCrossRef Klocke FJ, Baird MG, Bateman TM, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging—executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). J Am Coll Cardiol 2003;42:1318-33.PubMedCrossRef
5.
go back to reference Brown KA, Heller GV, Landin RS, Shaw LJ, Beller GA, Pasquale MJ, et al. Early dipyridamole (99m)Tc-sestamibi single photon emission computed tomographic imaging 2 to 4days after acute myocardial infarction predicts in-hospital and postdischarge cardiac events: comparison with submaximal exercise imaging. Circulation 1999;100:2060-6.PubMedCrossRef Brown KA, Heller GV, Landin RS, Shaw LJ, Beller GA, Pasquale MJ, et al. Early dipyridamole (99m)Tc-sestamibi single photon emission computed tomographic imaging 2 to 4days after acute myocardial infarction predicts in-hospital and postdischarge cardiac events: comparison with submaximal exercise imaging. Circulation 1999;100:2060-6.PubMedCrossRef
6.
go back to reference Shaw LJ, Hachamovitch R, Berman DS, Marwick TH, Lauer MS, Heller GV, et al. The economic consequences of available diagnostic and prognostic strategies for the evaluation of stable angina patients an observational assessment of the value of precatheterization ischemia. J Am Coll Cardiol 1999;33:661-9.PubMedCrossRef Shaw LJ, Hachamovitch R, Berman DS, Marwick TH, Lauer MS, Heller GV, et al. The economic consequences of available diagnostic and prognostic strategies for the evaluation of stable angina patients an observational assessment of the value of precatheterization ischemia. J Am Coll Cardiol 1999;33:661-9.PubMedCrossRef
7.
go back to reference Underwood SR, Godman B, Salvani S, Ogle JR, Ell PJ. Economics of myocardial perfusion imaging in Europe—the EMPIRE study. Eur Heart J 1999;20:157-66.PubMedCrossRef Underwood SR, Godman B, Salvani S, Ogle JR, Ell PJ. Economics of myocardial perfusion imaging in Europe—the EMPIRE study. Eur Heart J 1999;20:157-66.PubMedCrossRef
8.
go back to reference Underwood SR, Anagnostopoulos C, Cerqueira M, Ell PJ, Flint EJ, Harbinson M, et al. Myocardial perfusion scintigraphy: the evidence. Eur J Nucl Med Mol Imaging 2004;31:261-91.PubMedCrossRef Underwood SR, Anagnostopoulos C, Cerqueira M, Ell PJ, Flint EJ, Harbinson M, et al. Myocardial perfusion scintigraphy: the evidence. Eur J Nucl Med Mol Imaging 2004;31:261-91.PubMedCrossRef
9.
go back to reference Sharir T, Germano G, Kavanagh PB, Lai S, Cohen I, Lewin HC, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999;100:1035-42.PubMedCrossRef Sharir T, Germano G, Kavanagh PB, Lai S, Cohen I, Lewin HC, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999;100:1035-42.PubMedCrossRef
10.
go back to reference Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83.PubMedCrossRef Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83.PubMedCrossRef
11.
go back to reference Mitani I, Jain D, Joska TM, Burtness B, Zaret BL. Doxorubicin cardiotoxicity: prevention of congestive heart failure with serial cardiac function monitoring with equilibrium radionuclide angiocardiography in the current era. J Nucl Cardiol 2003;10:132-9.PubMedCrossRef Mitani I, Jain D, Joska TM, Burtness B, Zaret BL. Doxorubicin cardiotoxicity: prevention of congestive heart failure with serial cardiac function monitoring with equilibrium radionuclide angiocardiography in the current era. J Nucl Cardiol 2003;10:132-9.PubMedCrossRef
12.
go back to reference Ewer MS, Vooletich MT, Durand J-B, Woods ML, Davis JR, Valero V, et al. Reversibility of trastuzumab-related cardiotoxicity: new insights based on clinical course and response to medical treatment. J Clin Oncol 2005;23:7820-6.PubMedCrossRef Ewer MS, Vooletich MT, Durand J-B, Woods ML, Davis JR, Valero V, et al. Reversibility of trastuzumab-related cardiotoxicity: new insights based on clinical course and response to medical treatment. J Clin Oncol 2005;23:7820-6.PubMedCrossRef
13.
go back to reference Kies P, Bootsma M, Bax J, Schalij MJ, van der Wall EE. Arrhythmogenic right ventricular dysplasia/cardiomyopathy: screening, diagnosis, and treatment. Heart Rhythm 2006;3:225-34.PubMedCrossRef Kies P, Bootsma M, Bax J, Schalij MJ, van der Wall EE. Arrhythmogenic right ventricular dysplasia/cardiomyopathy: screening, diagnosis, and treatment. Heart Rhythm 2006;3:225-34.PubMedCrossRef
14.
go back to reference Borer JS, Hochreiter C, Herrold EM, Supino P, Aschermann M, Wencker D, et al. Prediction of indications for valve replacement among asymptomatic or minimally symptomatic patients with chronic aortic regurgitation and normal left ventricular performance. Circulation 1998;97:525-34.PubMedPubMedCentralCrossRef Borer JS, Hochreiter C, Herrold EM, Supino P, Aschermann M, Wencker D, et al. Prediction of indications for valve replacement among asymptomatic or minimally symptomatic patients with chronic aortic regurgitation and normal left ventricular performance. Circulation 1998;97:525-34.PubMedPubMedCentralCrossRef
15.
go back to reference Hesse B, Tägil K, Cuocolo A, Anagnostopoulos C, Bardiés M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 2005;32:855-97.PubMedCrossRef Hesse B, Tägil K, Cuocolo A, Anagnostopoulos C, Bardiés M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging 2005;32:855-97.PubMedCrossRef
16.
go back to reference AmerscanTM Stannous Agent, Technical leaflet. Amersham, 2001. AmerscanTM Stannous Agent, Technical leaflet. Amersham, 2001.
17.
go back to reference UltraTag RBC, Summary of product characteristics. Mallinckrodt, 2001. UltraTag RBC, Summary of product characteristics. Mallinckrodt, 2001.
18.
go back to reference Technescan PYP. Summary of product characteristics. Mallinckrodt, 2000. Technescan PYP. Summary of product characteristics. Mallinckrodt, 2000.
19.
go back to reference Ellis BL, Sampson CB. Radiolabelling of blood cells—theory and practice. In: Sampson CB, editor. Textbook of radiopharmacy theory and practice. 3rd ed. Amsterdam: Gordon and Breach Science; 1999. p. 83-104. Ellis BL, Sampson CB. Radiolabelling of blood cells—theory and practice. In: Sampson CB, editor. Textbook of radiopharmacy theory and practice. 3rd ed. Amsterdam: Gordon and Breach Science; 1999. p. 83-104.
20.
go back to reference Sampson CB. Complications and difficulties in radiolabelling blood cells: a review. Nucl Med Commun 1996;17:648-58.PubMedCrossRef Sampson CB. Complications and difficulties in radiolabelling blood cells: a review. Nucl Med Commun 1996;17:648-58.PubMedCrossRef
21.
go back to reference Zanelli GD. Effect of certain drugs used in the treatment of cardiovascular disease on the in-vitro labelling of red blood cells with 99mTc. Nucl Med Commun 1982;3:155-61.CrossRef Zanelli GD. Effect of certain drugs used in the treatment of cardiovascular disease on the in-vitro labelling of red blood cells with 99mTc. Nucl Med Commun 1982;3:155-61.CrossRef
22.
go back to reference International Atomic Energy Agency. Applying radiation safety standards in nuclear medicine no. 40. IAEA safety related publications. Appendix VI: guidance levels for diagnostic procedures. Vienna: IAEA; 2005. p. 101-5. International Atomic Energy Agency. Applying radiation safety standards in nuclear medicine no. 40. IAEA safety related publications. Appendix VI: guidance levels for diagnostic procedures. Vienna: IAEA; 2005. p. 101-5.
23.
go back to reference Lassmann M, Biassoni L, Monsieurs M, Franzius C, Jacobs F. The new EANM paediatric dosage card. Eur J Nucl Med Mol Imaging 2007;34:796-8.PubMedCrossRef Lassmann M, Biassoni L, Monsieurs M, Franzius C, Jacobs F. The new EANM paediatric dosage card. Eur J Nucl Med Mol Imaging 2007;34:796-8.PubMedCrossRef
24.
go back to reference Millar AM, Wathen CG, Muir AL. Failure in labelling of red blood cells with 99mTc: interaction between intravenous cannulae and stannous pyrophosphate. Eur J Nucl Med 1983;8:502-4.PubMedCrossRef Millar AM, Wathen CG, Muir AL. Failure in labelling of red blood cells with 99mTc: interaction between intravenous cannulae and stannous pyrophosphate. Eur J Nucl Med 1983;8:502-4.PubMedCrossRef
25.
go back to reference Pauwels EKJ, Feitsma RIJ, Blom J. Influence of adriamycin on red blood cell labelling; A pitfall in scintigraphic blood pool imaging. Nucl Med Commun 1983;4:290-5.CrossRef Pauwels EKJ, Feitsma RIJ, Blom J. Influence of adriamycin on red blood cell labelling; A pitfall in scintigraphic blood pool imaging. Nucl Med Commun 1983;4:290-5.CrossRef
26.
go back to reference Sampson CB. Adverse reactions and drug interactions with radiopharmaceuticals. Drug Safety 1993;8:280-94.PubMedCrossRef Sampson CB. Adverse reactions and drug interactions with radiopharmaceuticals. Drug Safety 1993;8:280-94.PubMedCrossRef
27.
go back to reference Lee HB, Wexler JP, Scharf SC, Blaufox MD. Pharmacologic alterations in Tc-99m binding by red blood cells: concise communication. J Nucl Med 1983;24:397-401.PubMed Lee HB, Wexler JP, Scharf SC, Blaufox MD. Pharmacologic alterations in Tc-99m binding by red blood cells: concise communication. J Nucl Med 1983;24:397-401.PubMed
28.
go back to reference International Commission on Radiological Protection. ICRP publication 80: radiation dose to patients from radiopharmaceuticals. Annals of the ICRP, vol. 28. Oxford: Pergamon; 1999. p. 61. International Commission on Radiological Protection. ICRP publication 80: radiation dose to patients from radiopharmaceuticals. Annals of the ICRP, vol. 28. Oxford: Pergamon; 1999. p. 61.
29.
go back to reference Mountford PJ, Lazarus CR, Edwards S. Radiopharmaceuticals. In: Bennet PN, editor. Drugs and human lactation. Amsterdam: Elsevier Science; 1996. p. 609-77.CrossRef Mountford PJ, Lazarus CR, Edwards S. Radiopharmaceuticals. In: Bennet PN, editor. Drugs and human lactation. Amsterdam: Elsevier Science; 1996. p. 609-77.CrossRef
30.
go back to reference Ahlgren L, Ivarsson S, Johansson L, Mattsson S, Nosslin B. Excretion of radionuclides in human breast milk after the administration of radiopharmaceuticals. J Nucl Med 1985;26:1085-90.PubMed Ahlgren L, Ivarsson S, Johansson L, Mattsson S, Nosslin B. Excretion of radionuclides in human breast milk after the administration of radiopharmaceuticals. J Nucl Med 1985;26:1085-90.PubMed
31.
go back to reference Rubow S, Klopper J, Wasserman H, Baard B, van Niekerk M. The excretion of radiopharmaceuticals in human breast milk: additional data and dosimetry. Eur J Nucl Med 1994;21:144-53.PubMedCrossRef Rubow S, Klopper J, Wasserman H, Baard B, van Niekerk M. The excretion of radiopharmaceuticals in human breast milk: additional data and dosimetry. Eur J Nucl Med 1994;21:144-53.PubMedCrossRef
32.
go back to reference International Atomic Energy Agency. Applying radiation safety standards in nuclear medicine No. 40. IAEA safety related publications, Appendix IV: Cessation of breast feeding. Vienna: IAEA; 2005. p. 97-9. International Atomic Energy Agency. Applying radiation safety standards in nuclear medicine No. 40. IAEA safety related publications, Appendix IV: Cessation of breast feeding. Vienna: IAEA; 2005. p. 97-9.
33.
go back to reference Administration of radioactive substances advisory committee. Notes for guidance on the clinical administration of radiopharmaceuticals and use of sealed radioactive sources. National Radiation Protection Board (UK), 2006. Administration of radioactive substances advisory committee. Notes for guidance on the clinical administration of radiopharmaceuticals and use of sealed radioactive sources. National Radiation Protection Board (UK), 2006.
34.
go back to reference Nowotnik DP, Verbruggen AM. Practical and physiochemical aspects of the preparation of 99mTc-labelled radiopharmaceuticals. In: Sampson CB, editor. Textbook of radiopharmacy theory and practice. 3rd ed. Amsterdam: Gordon and Breach Science Publishers; 1999. p. 37-56. Nowotnik DP, Verbruggen AM. Practical and physiochemical aspects of the preparation of 99mTc-labelled radiopharmaceuticals. In: Sampson CB, editor. Textbook of radiopharmacy theory and practice. 3rd ed. Amsterdam: Gordon and Breach Science Publishers; 1999. p. 37-56.
35.
go back to reference Vasculocis, Summary of product characteristics. CIS Biointernational; 1996. Vasculocis, Summary of product characteristics. CIS Biointernational; 1996.
36.
go back to reference Technescan HSA, Summary of product characteristics. Mallinckrodt; 2000. Technescan HSA, Summary of product characteristics. Mallinckrodt; 2000.
37.
go back to reference Silberstein EB, Ryan J. Prevalence of adverse reactions in nuclear medicine. Pharmacopeia Committee of the Society of Nuclear Medicine. J Nucl Med 1996;37:185-92, 1064-7.PubMed Silberstein EB, Ryan J. Prevalence of adverse reactions in nuclear medicine. Pharmacopeia Committee of the Society of Nuclear Medicine. J Nucl Med 1996;37:185-92, 1064-7.PubMed
38.
go back to reference Borer JS. Measurement of ventricular function and volume. In: George A, Beller MD, Zaret BL, editors. Nuclear cardiology: state of the art and future directions. 2nd ed. St. Louis: Mosby; 1999. p. 201-15. Borer JS. Measurement of ventricular function and volume. In: George A, Beller MD, Zaret BL, editors. Nuclear cardiology: state of the art and future directions. 2nd ed. St. Louis: Mosby; 1999. p. 201-15.
39.
go back to reference Nichols K, DePuey EG, Gooneratne N, Salensky H, Friedman M, Cochoff S. First-pass ventricular ejection fraction using a single-crystal nuclear camera. J Nucl Med 1994;35:1292-300.PubMed Nichols K, DePuey EG, Gooneratne N, Salensky H, Friedman M, Cochoff S. First-pass ventricular ejection fraction using a single-crystal nuclear camera. J Nucl Med 1994;35:1292-300.PubMed
40.
go back to reference Williams KA. Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography. J Nucl Cardiol 2005;12:86-95.PubMedCrossRef Williams KA. Measurement of ventricular function with scintigraphic techniques: part I-imaging hardware, radiopharmaceuticals, and first-pass radionuclide angiography. J Nucl Cardiol 2005;12:86-95.PubMedCrossRef
41.
go back to reference Marving J, Høilund-Carlsen PF, Chraemmer-Jørgensen B, Gadsbøll N. Are right and left ventricular ejection fractions equal? Ejection fractions in normal subjects and in patients with first acute myocardial infarction. Circulation 1985;72:502-14.PubMedCrossRef Marving J, Høilund-Carlsen PF, Chraemmer-Jørgensen B, Gadsbøll N. Are right and left ventricular ejection fractions equal? Ejection fractions in normal subjects and in patients with first acute myocardial infarction. Circulation 1985;72:502-14.PubMedCrossRef
42.
go back to reference Friedman JD, Berman DS, Borges-Neto S, Hayes SW, Johnson LL, Nichols KJ, et al. Quality Assurance Committee of the American Society of Nuclear Cardiology. First-pass radionuclide angiography. J Nucl Cardiol 2006;13:42-55.CrossRef Friedman JD, Berman DS, Borges-Neto S, Hayes SW, Johnson LL, Nichols KJ, et al. Quality Assurance Committee of the American Society of Nuclear Cardiology. First-pass radionuclide angiography. J Nucl Cardiol 2006;13:42-55.CrossRef
43.
go back to reference Hecht HS, Josephson MA, Hopkins JM, Singh BN. Reproducibility of ERNV in patients with coronary artery disease: response of left ventricular ejection fraction and regional wall motion to supine bicycle exercise. Am Heart J 1982;104:567-74.PubMedCrossRef Hecht HS, Josephson MA, Hopkins JM, Singh BN. Reproducibility of ERNV in patients with coronary artery disease: response of left ventricular ejection fraction and regional wall motion to supine bicycle exercise. Am Heart J 1982;104:567-74.PubMedCrossRef
44.
go back to reference Iftikhar I, Koutelou M, Mahmarian JJ, Verani MS. Simultaneous perfusion tomography and radionuclide angiography during dobutamine stress. J Nucl Med 1996;37:1306-10.PubMed Iftikhar I, Koutelou M, Mahmarian JJ, Verani MS. Simultaneous perfusion tomography and radionuclide angiography during dobutamine stress. J Nucl Med 1996;37:1306-10.PubMed
45.
go back to reference Cates CU, Kronenberg MW, Collins HW, Sandler MP. Dipyridamole radionuclide ventriculography: a test with high specificity for severe coronary artery disease. J Am Coll Cardiol 1989;13:841-51.PubMedCrossRef Cates CU, Kronenberg MW, Collins HW, Sandler MP. Dipyridamole radionuclide ventriculography: a test with high specificity for severe coronary artery disease. J Am Coll Cardiol 1989;13:841-51.PubMedCrossRef
46.
go back to reference Dymond DS, Foster C, Grenier RP, Carpenter J, Schmidt DH. Peak exercise and immediate postexercise imaging for the detection of left ventricular functional abnormalities in coronary artery disease. Am J Cardiol 1984;53:1532-7.PubMedCrossRef Dymond DS, Foster C, Grenier RP, Carpenter J, Schmidt DH. Peak exercise and immediate postexercise imaging for the detection of left ventricular functional abnormalities in coronary artery disease. Am J Cardiol 1984;53:1532-7.PubMedCrossRef
47.
go back to reference Tamaki N, Yasuda T, Moore R, Gill JB, Coucher CA, Hutter AM, et al. Continuous monitoring of left ventricular function by an ambulatory radionuclide detector in patients with coronary artery disease. J Am Coll Cardiol 1988;2:669-79.CrossRef Tamaki N, Yasuda T, Moore R, Gill JB, Coucher CA, Hutter AM, et al. Continuous monitoring of left ventricular function by an ambulatory radionuclide detector in patients with coronary artery disease. J Am Coll Cardiol 1988;2:669-79.CrossRef
48.
go back to reference Pace L, Cuocolo A, Stefano ML, Nappi A, Nicolai E, Imbriaco M, et al. Left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor: effects of different time averaging on accuracy. J Nucl Med 1993;34:1602-6.PubMed Pace L, Cuocolo A, Stefano ML, Nappi A, Nicolai E, Imbriaco M, et al. Left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor: effects of different time averaging on accuracy. J Nucl Med 1993;34:1602-6.PubMed
49.
go back to reference Hacker M, Hoyer X, Kupzyk S, Fougere CL, Kois J, Stempfle HU, et al. Clinical validation of the gated blood pool SPECT QBS((R)) processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography. Int J Cardiovasc Imaging 2006;22:407-16.PubMedCrossRef Hacker M, Hoyer X, Kupzyk S, Fougere CL, Kois J, Stempfle HU, et al. Clinical validation of the gated blood pool SPECT QBS((R)) processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography. Int J Cardiovasc Imaging 2006;22:407-16.PubMedCrossRef
50.
go back to reference Daou D, Van Kriekinge SD, Coaguila C, Lebtahi R, Fourme T, Sitbon O, et al. Automatic quantification of right ventricular function with gated blood pool SPECT. J Nucl Cardiol 2004;11:293-304.PubMedCrossRef Daou D, Van Kriekinge SD, Coaguila C, Lebtahi R, Fourme T, Sitbon O, et al. Automatic quantification of right ventricular function with gated blood pool SPECT. J Nucl Cardiol 2004;11:293-304.PubMedCrossRef
51.
go back to reference Kjaer A, Lebech AM, Hesse B, Petersen CL. Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI. Clin Physiol Funct Imaging 2005;25:344-9.PubMedCrossRef Kjaer A, Lebech AM, Hesse B, Petersen CL. Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT: comparison with cine MRI. Clin Physiol Funct Imaging 2005;25:344-9.PubMedCrossRef
52.
go back to reference Nichols K, Saouaf R, Ababneh AA, Barst RJ, Rosenbaum MS, Groch MW, et al. Validation of SPECT equilibrium radionuclide angiographic right ventricular parameters by cardiac magnetic resonance imaging. J Nucl Cardiol 2002;9:153-60.PubMedCrossRef Nichols K, Saouaf R, Ababneh AA, Barst RJ, Rosenbaum MS, Groch MW, et al. Validation of SPECT equilibrium radionuclide angiographic right ventricular parameters by cardiac magnetic resonance imaging. J Nucl Cardiol 2002;9:153-60.PubMedCrossRef
53.
go back to reference De BP, Nichols K, Vandenberghe S, Segers P, De WO, Van de WC, et al. Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom. J Nucl Med 2003;44:967-72. De BP, Nichols K, Vandenberghe S, Segers P, De WO, Van de WC, et al. Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom. J Nucl Med 2003;44:967-72.
54.
go back to reference De Bondt P, De Winter O, De Sutter J, Dierckx RA. Agreement between four available algorithms to evaluate global systolic left and right ventricular function from tomographic radionuclide ventriculography and comparison with planar imaging. Nucl Med Commun 2005;26:351-9.PubMedCrossRef De Bondt P, De Winter O, De Sutter J, Dierckx RA. Agreement between four available algorithms to evaluate global systolic left and right ventricular function from tomographic radionuclide ventriculography and comparison with planar imaging. Nucl Med Commun 2005;26:351-9.PubMedCrossRef
55.
go back to reference Akinboboye O, Nichols K, Wang Y, Dim UR, Reichek N. Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles. J Nucl Cardiol 2005;12:418-27.PubMedCrossRef Akinboboye O, Nichols K, Wang Y, Dim UR, Reichek N. Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles. J Nucl Cardiol 2005;12:418-27.PubMedCrossRef
56.
go back to reference Chin BB, Bloomgarden DC, Xia W, Kim HJ, Fayad ZA, Ferrari VA, et al. Right and left ventricular volume and ejection fraction by tomographic gated blood-pool scintigraphy. J Nucl Med 1997;38:942-8.PubMed Chin BB, Bloomgarden DC, Xia W, Kim HJ, Fayad ZA, Ferrari VA, et al. Right and left ventricular volume and ejection fraction by tomographic gated blood-pool scintigraphy. J Nucl Med 1997;38:942-8.PubMed
57.
go back to reference Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47.PubMed Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su HT, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47.PubMed
58.
go back to reference Ficaro EP, Quaife RA, Kritzman JN, Corbett JR. Accuracy and reproducibility of 3D-MSPECT for estimating left ventricular ejection fraction in patients with severe perfusion abnormalities (abstract). Circulation 1999;100(Suppl. 1):I26. Ficaro EP, Quaife RA, Kritzman JN, Corbett JR. Accuracy and reproducibility of 3D-MSPECT for estimating left ventricular ejection fraction in patients with severe perfusion abnormalities (abstract). Circulation 1999;100(Suppl. 1):I26.
59.
go back to reference Faber TL, Cooke CD, Folks RD, Vansant JP, Nichols KJ, DePuey EG, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med 1999;40:650-9.PubMed Faber TL, Cooke CD, Folks RD, Vansant JP, Nichols KJ, DePuey EG, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med 1999;40:650-9.PubMed
60.
go back to reference Schaefer WM, Lipke C, Standke D, Kuehl HP, Nowak B, Kaiser HJ, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med 2005;46:1256-63.PubMed Schaefer WM, Lipke C, Standke D, Kuehl HP, Nowak B, Kaiser HJ, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med 2005;46:1256-63.PubMed
61.
go back to reference Kubo N, Mabuchi M, Katoh C, Morita K, Tsukamoto E, Morita Y, et al. Accuracy and reproducibility of left ventricular function from quantitative, gated, single photon emission computed tomography using dynamic myocardial phantoms: effect of pre-reconstruction filters. Nucl Med Commun 2002;23:529-36.PubMedCrossRef Kubo N, Mabuchi M, Katoh C, Morita K, Tsukamoto E, Morita Y, et al. Accuracy and reproducibility of left ventricular function from quantitative, gated, single photon emission computed tomography using dynamic myocardial phantoms: effect of pre-reconstruction filters. Nucl Med Commun 2002;23:529-36.PubMedCrossRef
62.
go back to reference Wheat JM, Currie GM. QGS ejection fraction reproducibility in gated SPECT comparing pre-filtered and post-filtered reconstruction. Nucl Med Commun 2006;27:57-9.PubMedCrossRef Wheat JM, Currie GM. QGS ejection fraction reproducibility in gated SPECT comparing pre-filtered and post-filtered reconstruction. Nucl Med Commun 2006;27:57-9.PubMedCrossRef
63.
go back to reference Hashimoto J, Kubo A, Iwasaki R, Iwanaga S, Mitamura H, Ogawa S, et al. Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise. Eur J Nucl Med 1999;26:1541-6.PubMedCrossRef Hashimoto J, Kubo A, Iwasaki R, Iwanaga S, Mitamura H, Ogawa S, et al. Gated single-photon emission tomography imaging protocol to evaluate myocardial stunning after exercise. Eur J Nucl Med 1999;26:1541-6.PubMedCrossRef
64.
go back to reference Schaefer WM, Lipke CS, Nowak B, Kaiser HJ, Reinartz P, Buecker A, et al. Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI. J Nucl Med 2004;45:74-9.PubMed Schaefer WM, Lipke CS, Nowak B, Kaiser HJ, Reinartz P, Buecker A, et al. Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI. J Nucl Med 2004;45:74-9.PubMed
65.
go back to reference Slart RH, Bax JJ, de Jong RM, de Boer J, Lamb HJ, Mook PH, et al. Comparison of gated PET with MRI for evaluation of left ventricular function in patients with coronary artery disease. J Nucl Med 2004;45:176-82.PubMed Slart RH, Bax JJ, de Jong RM, de Boer J, Lamb HJ, Mook PH, et al. Comparison of gated PET with MRI for evaluation of left ventricular function in patients with coronary artery disease. J Nucl Med 2004;45:176-82.PubMed
66.
go back to reference Flotats A, Serra-Grima R, Camacho V, Mena E, Borras X, Estorch M, et al. Left ventricular end-diastolic volume is decreased at maximal exercise in athletes with marked repolarisation abnormalities: a continuous radionuclide monitoring study. Eur J Nucl Med Mol Imaging 2005;32:203-10.PubMedCrossRef Flotats A, Serra-Grima R, Camacho V, Mena E, Borras X, Estorch M, et al. Left ventricular end-diastolic volume is decreased at maximal exercise in athletes with marked repolarisation abnormalities: a continuous radionuclide monitoring study. Eur J Nucl Med Mol Imaging 2005;32:203-10.PubMedCrossRef
67.
go back to reference Pfisterer N, Regenass S, Müller-Brand J, Burkart F. Ambulatory scintigraphic assessment of transient changes in left ventricular function: a new method for detection of silent myocardial ischaemia. Eur Heart J 1988;9(Suppl N):98-103.PubMedCrossRef Pfisterer N, Regenass S, Müller-Brand J, Burkart F. Ambulatory scintigraphic assessment of transient changes in left ventricular function: a new method for detection of silent myocardial ischaemia. Eur Heart J 1988;9(Suppl N):98-103.PubMedCrossRef
68.
go back to reference Yang LD, Bairey MN, Berman DS, Nichols KJ, Odom-Maryon T, Rozansky A. Accuracy and reproducibility of left ventricular ejection fraction measurements using an ambulatory radionuclide left ventricular function monitor. J Nucl Med 1991;32:796-802.PubMed Yang LD, Bairey MN, Berman DS, Nichols KJ, Odom-Maryon T, Rozansky A. Accuracy and reproducibility of left ventricular ejection fraction measurements using an ambulatory radionuclide left ventricular function monitor. J Nucl Med 1991;32:796-802.PubMed
69.
go back to reference Pace L, Cuocolo A, Nappi A, Nicolai E, Trimarco B, Salvatore M. Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor. Eur J Nucl Med 1992;19:800-6.PubMedCrossRef Pace L, Cuocolo A, Nappi A, Nicolai E, Trimarco B, Salvatore M. Accuracy and repeatability of left ventricular systolic and diastolic function measurements using an ambulatory radionuclide monitor. Eur J Nucl Med 1992;19:800-6.PubMedCrossRef
70.
go back to reference Jain D, Joska T, Lee FA, Burg M, Lampert R, Zaret BL. Day-to-day reproducibility of mental stress-induced abnormal left ventricular function response in patients with coronary artery disease and its relationship to autonomic activation. J Nucl Cardiol 2001;8:347-55.PubMedCrossRef Jain D, Joska T, Lee FA, Burg M, Lampert R, Zaret BL. Day-to-day reproducibility of mental stress-induced abnormal left ventricular function response in patients with coronary artery disease and its relationship to autonomic activation. J Nucl Cardiol 2001;8:347-55.PubMedCrossRef
71.
go back to reference Tamaki N, Gill JB, Moore RH, Yasuda T, Boucher CA, Strauss HW. Cardiac response to daily activities and exercise in normal subjects assessed by an ambulatory ventricular function monitor. Am J Cardiol 1987;59:1164-9.PubMedCrossRef Tamaki N, Gill JB, Moore RH, Yasuda T, Boucher CA, Strauss HW. Cardiac response to daily activities and exercise in normal subjects assessed by an ambulatory ventricular function monitor. Am J Cardiol 1987;59:1164-9.PubMedCrossRef
72.
go back to reference Kayden DS, Remetz MS, Cabin HS, Deckelbaum LI, Cleman MW, Wackers FJ, et al. Validation of continuous radionuclide left ventricular function monitoring in detecting silent myocardial ischemia during balloon angioplasty of the left anterior descending artery. Am J Cardiol 1991;67:1339-43.PubMedCrossRef Kayden DS, Remetz MS, Cabin HS, Deckelbaum LI, Cleman MW, Wackers FJ, et al. Validation of continuous radionuclide left ventricular function monitoring in detecting silent myocardial ischemia during balloon angioplasty of the left anterior descending artery. Am J Cardiol 1991;67:1339-43.PubMedCrossRef
73.
go back to reference Bairey CN, de Yang L, Berman DS, Rozanski A. Comparison of physiologic ejection fraction responses to activities of daily living: implications for clinical testing. J Am Coll Cardiol 1990;16:847-54.PubMedCrossRef Bairey CN, de Yang L, Berman DS, Rozanski A. Comparison of physiologic ejection fraction responses to activities of daily living: implications for clinical testing. J Am Coll Cardiol 1990;16:847-54.PubMedCrossRef
74.
go back to reference Wolz DE, Flores AR, Grandis DJ, Orie JE, Schulman DS. Abnormal left ventricular ejection fraction response to mental stress and exercise in cardiomyopathy. J Nucl Cardiol 1995;2:144-50.PubMedCrossRef Wolz DE, Flores AR, Grandis DJ, Orie JE, Schulman DS. Abnormal left ventricular ejection fraction response to mental stress and exercise in cardiomyopathy. J Nucl Cardiol 1995;2:144-50.PubMedCrossRef
75.
go back to reference Fearnow EC 3rd, Stanfield JA, Jaszczak RJ, Harris CC, Coleman RE. Factors affecting ventricular volumes determined by a count-based equilibrium method. J Nucl Med 1985;26:1042-7.PubMed Fearnow EC 3rd, Stanfield JA, Jaszczak RJ, Harris CC, Coleman RE. Factors affecting ventricular volumes determined by a count-based equilibrium method. J Nucl Med 1985;26:1042-7.PubMed
76.
go back to reference Wieshammer S, Hetzel M, Hetzel J, Henze E, Clausen M, Hombach V. Reproducibility of left ventricular volume measurements at rest and during bicycle exercise in patients with congestive heart failure: A combined radionuclide and haemodynamic study. Nucl Med Commun 1996;17:591-5.PubMedCrossRef Wieshammer S, Hetzel M, Hetzel J, Henze E, Clausen M, Hombach V. Reproducibility of left ventricular volume measurements at rest and during bicycle exercise in patients with congestive heart failure: A combined radionuclide and haemodynamic study. Nucl Med Commun 1996;17:591-5.PubMedCrossRef
77.
go back to reference Seldin DW, Esser PD, Nichols AB, Ratner SJ, Alderson PO. Left ventricular volume determination from scintigraphy and digital angiography by a semi-automatic geometric method. Radiology 1983;149:809-13.PubMedCrossRef Seldin DW, Esser PD, Nichols AB, Ratner SJ, Alderson PO. Left ventricular volume determination from scintigraphy and digital angiography by a semi-automatic geometric method. Radiology 1983;149:809-13.PubMedCrossRef
78.
go back to reference Gal JA, Grenier RP, Port SC, Dymond DS, Schmidt DH. Left ventricular volume calculation using a count-based ratio method applied to first-passradionucide angiography. J Nucl Med 1992;33:2124-32.PubMed Gal JA, Grenier RP, Port SC, Dymond DS, Schmidt DH. Left ventricular volume calculation using a count-based ratio method applied to first-passradionucide angiography. J Nucl Med 1992;33:2124-32.PubMed
79.
go back to reference Massardo T, Gal RA, Grenier RP, Schmidt DH, Port SC. Left ventricular volume calculation using a count based ratio method applied to multigated radionuclide angiography. J Nucl Med 1990;31:450-6.PubMed Massardo T, Gal RA, Grenier RP, Schmidt DH, Port SC. Left ventricular volume calculation using a count based ratio method applied to multigated radionuclide angiography. J Nucl Med 1990;31:450-6.PubMed
80.
go back to reference Thorley PJ, Sheard KL, Rees MR. A comparison of methods for estimating left ventricular from radionuclide ventriculography. Physiol Meas 1993;14:23-32.PubMedCrossRef Thorley PJ, Sheard KL, Rees MR. A comparison of methods for estimating left ventricular from radionuclide ventriculography. Physiol Meas 1993;14:23-32.PubMedCrossRef
81.
go back to reference Nichols K, Humayun N, De Bondt P, Vandenberghe S, Akinboboye OO, Bergmann SR. Model dependence of gated blood pool SPECT ventricular function measurements. J Nucl Cardiol 2004;11:282-92.PubMedCrossRef Nichols K, Humayun N, De Bondt P, Vandenberghe S, Akinboboye OO, Bergmann SR. Model dependence of gated blood pool SPECT ventricular function measurements. J Nucl Cardiol 2004;11:282-92.PubMedCrossRef
82.
go back to reference De Bondt P, Nichols K, Vandenberghe S, Segers P, De Winter O, Van de Wiele C, et al. Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom. J Nucl Med 2003;44:967-72.PubMed De Bondt P, Nichols K, Vandenberghe S, Segers P, De Winter O, Van de Wiele C, et al. Validation of gated blood-pool SPECT cardiac measurements tested using a biventricular dynamic physical phantom. J Nucl Med 2003;44:967-72.PubMed
83.
go back to reference Sharir T, Germano G, Kang X, Lewin HC, Miranda R, Cohen I, et al. Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: Risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med 2001;42:831-7.PubMed Sharir T, Germano G, Kang X, Lewin HC, Miranda R, Cohen I, et al. Prediction of myocardial infarction versus cardiac death by gated myocardial perfusion SPECT: Risk stratification by the amount of stress-induced ischemia and the poststress ejection fraction. J Nucl Med 2001;42:831-7.PubMed
84.
go back to reference Goris ML, Thompson C, Malone LJ, Franken PR. Modelling the integration of myocardial regional perfusion and function. Nucl Med Commun 1994;15:9-20.PubMedCrossRef Goris ML, Thompson C, Malone LJ, Franken PR. Modelling the integration of myocardial regional perfusion and function. Nucl Med Commun 1994;15:9-20.PubMedCrossRef
85.
go back to reference Everaert H, Franken PR, Flamen P, Goris M, Momen A, Bossuyt A. Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on the radial distribution of count rate density across the myocardial wall. Eur J Nucl Med 1996;23:1628-33.PubMedCrossRef Everaert H, Franken PR, Flamen P, Goris M, Momen A, Bossuyt A. Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on the radial distribution of count rate density across the myocardial wall. Eur J Nucl Med 1996;23:1628-33.PubMedCrossRef
86.
go back to reference Faber TL, Stokely EM, Peshock RM, Corbett JR. A model-based four-dimensional left-ventricular surface detector. IEEE Trans Med Imag 1991;10:321-9.CrossRef Faber TL, Stokely EM, Peshock RM, Corbett JR. A model-based four-dimensional left-ventricular surface detector. IEEE Trans Med Imag 1991;10:321-9.CrossRef
87.
go back to reference Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R, et al. Validation of left ventricular volume measurements by gated SPECT Tc-99m-labeled sestamibi imaging. J Nucl Cardiol 1998;5:574-8.PubMedCrossRef Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R, et al. Validation of left ventricular volume measurements by gated SPECT Tc-99m-labeled sestamibi imaging. J Nucl Cardiol 1998;5:574-8.PubMedCrossRef
88.
go back to reference Achtert AD, King MA, Dahlberg ST, Pretorius PH, LaCroix KJ, Tsui BM. An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images. J Nucl Cardiol 1998;5:144-52.PubMedCrossRef Achtert AD, King MA, Dahlberg ST, Pretorius PH, LaCroix KJ, Tsui BM. An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images. J Nucl Cardiol 1998;5:144-52.PubMedCrossRef
89.
go back to reference Lipke CS, Kuhl HP, Nowak B, Kaiser HJ, Reinartz P, Koch KC, et al. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated Tc-99m-MIBI SPET: comparison with cardiac magnetic resonance imaging. Eur J Nucl Med Mol Imaging 2004;31:482-90.PubMedCrossRef Lipke CS, Kuhl HP, Nowak B, Kaiser HJ, Reinartz P, Koch KC, et al. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated Tc-99m-MIBI SPET: comparison with cardiac magnetic resonance imaging. Eur J Nucl Med Mol Imaging 2004;31:482-90.PubMedCrossRef
90.
go back to reference Thorley PJ, Smith JM. Repeatability of left ventricular ejection fraction and volume measurement for (99)mTc-tetrofosmin gated single photon emission computed tomography (SPECT). Nucl Med Commun 2005;26:345-9.PubMedCrossRef Thorley PJ, Smith JM. Repeatability of left ventricular ejection fraction and volume measurement for (99)mTc-tetrofosmin gated single photon emission computed tomography (SPECT). Nucl Med Commun 2005;26:345-9.PubMedCrossRef
91.
go back to reference Mazzanti M, Germano G, Kiat H, Kavanagh PB, Alexanderson E, Friedman JD, et al. Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT. J Am Coll Cardiol 1996;27:1612-20.PubMedCrossRef Mazzanti M, Germano G, Kiat H, Kavanagh PB, Alexanderson E, Friedman JD, et al. Identification of severe and extensive coronary artery disease by automatic measurement of transient ischemic dilation of the left ventricle in dual-isotope myocardial perfusion SPECT. J Am Coll Cardiol 1996;27:1612-20.PubMedCrossRef
92.
go back to reference Bestetti A, Di Leo C, Alessi A, Triulzi A, Tagliabue L, Tarolo GL. Post-stress end-systolic left ventricular dilation: a marker of endocardial post-ischemic stunning. Nucl Med Commun 2001;22:685-93.PubMedCrossRef Bestetti A, Di Leo C, Alessi A, Triulzi A, Tagliabue L, Tarolo GL. Post-stress end-systolic left ventricular dilation: a marker of endocardial post-ischemic stunning. Nucl Med Commun 2001;22:685-93.PubMedCrossRef
93.
go back to reference Anagnostopoulos C, Harbinson M, Kelion A, Kundley K, Loong CY, Notghi A, et al. Procedure guidelines for radionuclide myocardial perfusion imaging. Heart 2004;90(Suppl 1):i1-10.PubMedPubMedCentralCrossRef Anagnostopoulos C, Harbinson M, Kelion A, Kundley K, Loong CY, Notghi A, et al. Procedure guidelines for radionuclide myocardial perfusion imaging. Heart 2004;90(Suppl 1):i1-10.PubMedPubMedCentralCrossRef
94.
go back to reference Scheiner J, Sinusas A, Wittry MD, Royal HD, Machac J, Balon HR, et al. Society of Nuclear Medicine procedure guideline for gated equilibrium radionuclide ventriculography 2002. Society of Nuclear Medicine procedure guidelines, cardiac: gated equilibrium radionuclide ventriculography 3.0. http://www.snm.org. Scheiner J, Sinusas A, Wittry MD, Royal HD, Machac J, Balon HR, et al. Society of Nuclear Medicine procedure guideline for gated equilibrium radionuclide ventriculography 2002. Society of Nuclear Medicine procedure guidelines, cardiac: gated equilibrium radionuclide ventriculography 3.0. http://​www.​snm.​org.
95.
go back to reference Corbett JR, Akinboboye OO, Bacharach SL, Borer JS, Botvinick EH, DePuey EG, et al. Equilibrium radionuclide angiocardiography. J Nucl Cardiol 2006;13:e56-79.PubMedCrossRef Corbett JR, Akinboboye OO, Bacharach SL, Borer JS, Botvinick EH, DePuey EG, et al. Equilibrium radionuclide angiocardiography. J Nucl Cardiol 2006;13:e56-79.PubMedCrossRef
96.
go back to reference Brateman L, Buckley K, Keim SG, Wargovich TJ, Williams CM. Left ventricular regional wall motion assessment by radionuclide ventriculography: a comparison of cine display with Fourier imaging. J Nucl Med 1991;32:777-82.PubMed Brateman L, Buckley K, Keim SG, Wargovich TJ, Williams CM. Left ventricular regional wall motion assessment by radionuclide ventriculography: a comparison of cine display with Fourier imaging. J Nucl Med 1991;32:777-82.PubMed
97.
go back to reference Walton S, Yiannikas J, Jarritt PH, Brown NJ, Swanton RH, Ell PJ. Phasic abnormalities of left ventricular emptying in coronary artery disease. Br Heart J 1981;46:245-53.PubMedPubMedCentralCrossRef Walton S, Yiannikas J, Jarritt PH, Brown NJ, Swanton RH, Ell PJ. Phasic abnormalities of left ventricular emptying in coronary artery disease. Br Heart J 1981;46:245-53.PubMedPubMedCentralCrossRef
98.
go back to reference Underwood SR, Walton S, Laming PJ, Ell PJ, Emanuel RW, Swanton RH. Patterns of ventricular contraction in patients with conduction abnormality studied by radionuclide angiocardiography. Br Heart J 1984;51:568-74.PubMedPubMedCentralCrossRef Underwood SR, Walton S, Laming PJ, Ell PJ, Emanuel RW, Swanton RH. Patterns of ventricular contraction in patients with conduction abnormality studied by radionuclide angiocardiography. Br Heart J 1984;51:568-74.PubMedPubMedCentralCrossRef
99.
go back to reference Muramatsu T, Matsumoto K, Nishimura S. Efficacy of the phase images in Fourier analysis using gated cardiac POOL-SPECT for determining the indication for cardiac resynchronization therapy. Circ J 2005;69:1521-6.PubMedCrossRef Muramatsu T, Matsumoto K, Nishimura S. Efficacy of the phase images in Fourier analysis using gated cardiac POOL-SPECT for determining the indication for cardiac resynchronization therapy. Circ J 2005;69:1521-6.PubMedCrossRef
100.
go back to reference Metcalfe MJ, Norton MY, Jennings K, Walton S. Improved detection of abnormal left ventricular wall motion using tomographic radionuclide ventriculography compared with planar radionuclide and single plane contrast ventriculography. Brit J Radiol 1993;66:986-93.PubMedCrossRef Metcalfe MJ, Norton MY, Jennings K, Walton S. Improved detection of abnormal left ventricular wall motion using tomographic radionuclide ventriculography compared with planar radionuclide and single plane contrast ventriculography. Brit J Radiol 1993;66:986-93.PubMedCrossRef
101.
go back to reference Abidov A, Germano G, Hachamovitch R, Berman DS. Gated SPECT in assessment of regional ad global left ventricular function: major tool of modern nuclear imaging. J Nucl Cardiol 2006;13:261-79.PubMedCrossRef Abidov A, Germano G, Hachamovitch R, Berman DS. Gated SPECT in assessment of regional ad global left ventricular function: major tool of modern nuclear imaging. J Nucl Cardiol 2006;13:261-79.PubMedCrossRef
102.
go back to reference Paulus WJ, Tschöpe C, Sanderson JE, Rusconi C, Flachskampf FA, Rademakers FE, et al. How to diagnose diastolic heart failure: a consensus statement on the diagnosis of heart failure with normal left ventricular ejection fraction by the Heart Failure and Echocardiography Associations of the European Society of Cardiology. Eur Heart J 2007;28:2539-50.PubMedCrossRef Paulus WJ, Tschöpe C, Sanderson JE, Rusconi C, Flachskampf FA, Rademakers FE, et al. How to diagnose diastolic heart failure: a consensus statement on the diagnosis of heart failure with normal left ventricular ejection fraction by the Heart Failure and Echocardiography Associations of the European Society of Cardiology. Eur Heart J 2007;28:2539-50.PubMedCrossRef
103.
go back to reference Wackers FJTh. Equilibrium radionuclide angiograhy. In: Gerson MC, editor. Cardiac nuclear medicine. 3rd ed. New York: McGraw Hill; 1997. p. 315-45. Wackers FJTh. Equilibrium radionuclide angiograhy. In: Gerson MC, editor. Cardiac nuclear medicine. 3rd ed. New York: McGraw Hill; 1997. p. 315-45.
104.
go back to reference Arrighi JA, Soufer R. Left ventricular diastolic function: physiology. Methods of assessment, and clinical significance. J Nucl Cardiol 1995;2:525-43.PubMedCrossRef Arrighi JA, Soufer R. Left ventricular diastolic function: physiology. Methods of assessment, and clinical significance. J Nucl Cardiol 1995;2:525-43.PubMedCrossRef
105.
go back to reference Clements IP, Sinak LJ, Gibbons RJ, Brown ML, O’Connor MKl. Determination of diastolic function by radionuclide ventriculography. Mayo Clin Proc 1990;65:1007-19.PubMedCrossRef Clements IP, Sinak LJ, Gibbons RJ, Brown ML, O’Connor MKl. Determination of diastolic function by radionuclide ventriculography. Mayo Clin Proc 1990;65:1007-19.PubMedCrossRef
106.
go back to reference Bonow RO, Vitale DF, Bacharach SL, Maron BJ, Green MV. Effects of aging on asynchronus left ventricular regional function and global ventricular filling in normal human subjects. J Am Coll Cardiol 1988;11:50-8.PubMedCrossRef Bonow RO, Vitale DF, Bacharach SL, Maron BJ, Green MV. Effects of aging on asynchronus left ventricular regional function and global ventricular filling in normal human subjects. J Am Coll Cardiol 1988;11:50-8.PubMedCrossRef
107.
go back to reference Bonow RO, Bacharach SL, Green MV, Kent KM, Rosing DR, Lipson LC, et al. Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography. Circulation 1981;64:315-23.PubMedCrossRef Bonow RO, Bacharach SL, Green MV, Kent KM, Rosing DR, Lipson LC, et al. Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography. Circulation 1981;64:315-23.PubMedCrossRef
108.
go back to reference Parker JA, Uren RF, Jones AG, Maddox DE, Zimmerman RE, Neill JM, et al. Radionuclide left ventriculography with the slant hole collimator. J Nucl Med 1977;18:848-51.PubMed Parker JA, Uren RF, Jones AG, Maddox DE, Zimmerman RE, Neill JM, et al. Radionuclide left ventriculography with the slant hole collimator. J Nucl Med 1977;18:848-51.PubMed
109.
go back to reference Gunter DL. Collimator Design for Nuclear Medicine. In: Wernick M, Aarsvold J, editors. Emission tomography: the fundamentals of PET and SPECT. San Diego, London: Elsevier Academic; 2004. p. 153-68.CrossRef Gunter DL. Collimator Design for Nuclear Medicine. In: Wernick M, Aarsvold J, editors. Emission tomography: the fundamentals of PET and SPECT. San Diego, London: Elsevier Academic; 2004. p. 153-68.CrossRef
110.
go back to reference Liu YH, Lam PT, Sinusas AJ, Wackers FJ. Differential effect of 180 degrees and 360 degrees acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms. J Nucl Med 2002;43:1115-24.PubMed Liu YH, Lam PT, Sinusas AJ, Wackers FJ. Differential effect of 180 degrees and 360 degrees acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms. J Nucl Med 2002;43:1115-24.PubMed
111.
go back to reference Friedman JD, Berman DS, Kiat H, Bietendorf J, Hyun M, Van Train KF, et al. Rest and treadmill exercise first-pass radionuclide ventriculography: validation of left ventricular ejection fraction measurements. J Nucl Cardiol 1994;1:382-8.PubMedCrossRef Friedman JD, Berman DS, Kiat H, Bietendorf J, Hyun M, Van Train KF, et al. Rest and treadmill exercise first-pass radionuclide ventriculography: validation of left ventricular ejection fraction measurements. J Nucl Cardiol 1994;1:382-8.PubMedCrossRef
112.
go back to reference Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28:844-51.PubMed Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med 1987;28:844-51.PubMed
113.
go back to reference Tan P, Bailey DL, Meikle SR, Eberl S, Fulton RR, Hutton BF. A scanning line source for sumultaneous emission and transmission measurements in SPECT. J Nucl Med 1993;34:1752-60.PubMed Tan P, Bailey DL, Meikle SR, Eberl S, Fulton RR, Hutton BF. A scanning line source for sumultaneous emission and transmission measurements in SPECT. J Nucl Med 1993;34:1752-60.PubMed
114.
go back to reference Celler A, Sitek A, Stoub E, Hawman P, Harrop R, Lyster D. Multiple line source array for SPECT transmission scans: simulation, phantom and patient studies. J Nucl Med 1998;39:2183-9.PubMed Celler A, Sitek A, Stoub E, Hawman P, Harrop R, Lyster D. Multiple line source array for SPECT transmission scans: simulation, phantom and patient studies. J Nucl Med 1998;39:2183-9.PubMed
115.
go back to reference Hasegawa BH, Lang TF, Brown JK, Gingold EL, Reilly SM, Blankespoor SC, et al. Object-specific attenuation correction for SPECT with correlated dual-energy X-ray CT. IEEE Trans Nucl Sci 1993;40:1242-52.CrossRef Hasegawa BH, Lang TF, Brown JK, Gingold EL, Reilly SM, Blankespoor SC, et al. Object-specific attenuation correction for SPECT with correlated dual-energy X-ray CT. IEEE Trans Nucl Sci 1993;40:1242-52.CrossRef
116.
go back to reference Blankespoor SC, Xu X, Kaiki K, Brown JK, Tang HR, Cann CE. Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment. IEEE Trans Nucl Sci 1996;43:2263-74.CrossRef Blankespoor SC, Xu X, Kaiki K, Brown JK, Tang HR, Cann CE. Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessment. IEEE Trans Nucl Sci 1996;43:2263-74.CrossRef
117.
go back to reference Schelbert HR, Verba JW, Johnson AD, Brock GW, Alazraki NP, Rose FJ, et al. Nontraumatic determination of left ventricular ejection fraction by radionuclide angiocardiography. Circulation 1975;51:902-9.PubMedCrossRef Schelbert HR, Verba JW, Johnson AD, Brock GW, Alazraki NP, Rose FJ, et al. Nontraumatic determination of left ventricular ejection fraction by radionuclide angiocardiography. Circulation 1975;51:902-9.PubMedCrossRef
118.
go back to reference Germano G, Kavanagh PB, Su HT, Mazzanti M, Kiat H, Hachamovitch R, et al. Automatic reorientation of 3-dimensional transaxial myocardial perfusion SPECT images. J Nucl Med 1995;36:1107-14.PubMed Germano G, Kavanagh PB, Su HT, Mazzanti M, Kiat H, Hachamovitch R, et al. Automatic reorientation of 3-dimensional transaxial myocardial perfusion SPECT images. J Nucl Med 1995;36:1107-14.PubMed
119.
go back to reference Mullick R, Ezquierra NF. Automatic determination of left ventricular orientation from SPECT data. IEEE Trans Med Imag 1995;14:88-99.CrossRef Mullick R, Ezquierra NF. Automatic determination of left ventricular orientation from SPECT data. IEEE Trans Med Imag 1995;14:88-99.CrossRef
120.
go back to reference Ratib O, Henze E, Schon H, Schelbert HR. Phase analysis of radionuclide ventriculograms for the detection of coronary artery disease. Am Heart J 1982;104:1-12.PubMedCrossRef Ratib O, Henze E, Schon H, Schelbert HR. Phase analysis of radionuclide ventriculograms for the detection of coronary artery disease. Am Heart J 1982;104:1-12.PubMedCrossRef
121.
go back to reference Wu J, Takeda T, Toyama H, Ajisaka R, Masuoka T, Watanabe S, et al. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography. Ann Nucl Med 1999;13:13-8.PubMedCrossRef Wu J, Takeda T, Toyama H, Ajisaka R, Masuoka T, Watanabe S, et al. Phase changes caused by hyperventilation stress in spastic angina pectoris analyzed by first-pass radionuclide ventriculography. Ann Nucl Med 1999;13:13-8.PubMedCrossRef
122.
go back to reference Faber TL, Stokely EM, Templeton GH, Akers MS, Parkey RW, Corbett JR. Quantification of three-dimensional left ventricular segmental wall motion and volumes from gated tomographic radionuclide ventriculograms. J Nucl Med 1989;30:638-49.PubMed Faber TL, Stokely EM, Templeton GH, Akers MS, Parkey RW, Corbett JR. Quantification of three-dimensional left ventricular segmental wall motion and volumes from gated tomographic radionuclide ventriculograms. J Nucl Med 1989;30:638-49.PubMed
123.
go back to reference Bartlett ML, Srinivasan G, Barker WC, Kitsiou AN, Dilsizian V, Bacharach SL. Left ventricular ejection fraction: comparison of results from planar and SPECT gated blood-pool studies. J Nucl Med 1996;37:1795-9.PubMed Bartlett ML, Srinivasan G, Barker WC, Kitsiou AN, Dilsizian V, Bacharach SL. Left ventricular ejection fraction: comparison of results from planar and SPECT gated blood-pool studies. J Nucl Med 1996;37:1795-9.PubMed
124.
go back to reference van Kriekinge SD, Berman DS, Germano G. Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT. J Nucl Cardiol 1999;6:498-506.PubMedCrossRef van Kriekinge SD, Berman DS, Germano G. Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT. J Nucl Cardiol 1999;6:498-506.PubMedCrossRef
125.
go back to reference Links JM, Becker LC, Shindledecker JG, Guzman P, Burow RD, Nickoloff EL, et al. Measurement of absolute left ventricular volume from gated blood-pool studies. Circulation 1982;65:82-91.PubMedCrossRef Links JM, Becker LC, Shindledecker JG, Guzman P, Burow RD, Nickoloff EL, et al. Measurement of absolute left ventricular volume from gated blood-pool studies. Circulation 1982;65:82-91.PubMedCrossRef
126.
go back to reference Stegger L, Biedenstein S, Schäfers KP, Schober O, Schäfers MA. Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET. Eur J Nucl Med 2001;28:48-55.PubMedCrossRef Stegger L, Biedenstein S, Schäfers KP, Schober O, Schäfers MA. Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET. Eur J Nucl Med 2001;28:48-55.PubMedCrossRef
127.
go back to reference Pfisterer ME, Battler A, Zaret BL. Range of normal values for left and right ventricular ejection fraction at rest and during exercise assessed by radionuclide angiocardiography. Eur Heart J 1985;6:647-55.PubMedCrossRef Pfisterer ME, Battler A, Zaret BL. Range of normal values for left and right ventricular ejection fraction at rest and during exercise assessed by radionuclide angiocardiography. Eur Heart J 1985;6:647-55.PubMedCrossRef
128.
go back to reference Chung AK, Das SR, Leonard D, Peshock RM, Kazi F, Abdullah SM, et al. Women have higher left ventricular ejection fractions than men independent of differences in left ventricular volume. The Dallas Heart Study. Circulation 2006;113:1597-604.PubMedCrossRef Chung AK, Das SR, Leonard D, Peshock RM, Kazi F, Abdullah SM, et al. Women have higher left ventricular ejection fractions than men independent of differences in left ventricular volume. The Dallas Heart Study. Circulation 2006;113:1597-604.PubMedCrossRef
129.
go back to reference Ababneh AA, Sciacca RR, Kim B, Bergmann SR. Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: influence of tracer, gender, and acquisition camera. J Nucl Cardiol 2000;7:661-8.PubMedCrossRef Ababneh AA, Sciacca RR, Kim B, Bergmann SR. Normal limits for left ventricular ejection fraction and volumes estimated with gated myocardial perfusion imaging in patients with normal exercise test results: influence of tracer, gender, and acquisition camera. J Nucl Cardiol 2000;7:661-8.PubMedCrossRef
130.
go back to reference Rozanski A, Nichols K, Yao SS, Malholtra S, Cohen R, DePuey EG. Development and application of normal limits for left ventricular ejection fraction and volume measurements from 99mTc-sestamibi myocardial perfusion gates SPECT. J Nucl Med 2000;41:1445-50.PubMed Rozanski A, Nichols K, Yao SS, Malholtra S, Cohen R, DePuey EG. Development and application of normal limits for left ventricular ejection fraction and volume measurements from 99mTc-sestamibi myocardial perfusion gates SPECT. J Nucl Med 2000;41:1445-50.PubMed
131.
go back to reference Sharir T, Kang X, Germano G, Bax JJ, Shaw LJ, Gransar H, et al. Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: gender-related differences in normal limits and outcomes. J Nucl Cardiol 2006;13:495-506.PubMedCrossRef Sharir T, Kang X, Germano G, Bax JJ, Shaw LJ, Gransar H, et al. Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: gender-related differences in normal limits and outcomes. J Nucl Cardiol 2006;13:495-506.PubMedCrossRef
132.
go back to reference Lum DP, Coel MN. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 2003;24:259-66.PubMedCrossRef Lum DP, Coel MN. Comparison of automatic quantification software for the measurement of ventricular volume and ejection fraction in gated myocardial perfusion SPECT. Nucl Med Commun 2003;24:259-66.PubMedCrossRef
133.
go back to reference Navare SM, Wackers FJ, Liu YH. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 2003;30:1330-7.PubMedCrossRef Navare SM, Wackers FJ, Liu YH. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 2003;30:1330-7.PubMedCrossRef
134.
go back to reference Ramakrishna G, Miller TD, Hodge DO, O’Connor MK, Gibbons RJ. Differences in left ventricular ejection fraction and volumes measured at rest and poststress by gated sestamibi SPECT. J Nucl Cardiol 2006;13:668-74.PubMedCrossRef Ramakrishna G, Miller TD, Hodge DO, O’Connor MK, Gibbons RJ. Differences in left ventricular ejection fraction and volumes measured at rest and poststress by gated sestamibi SPECT. J Nucl Cardiol 2006;13:668-74.PubMedCrossRef
135.
go back to reference Higgins JP, Higgins JA, Williams G. Stress-induced abnormalities in myocardial perfusion imaging that are not related to perfusion but are of diagnostic and prognostic importance. Eur J Nucl Med Mol Imaging 2007;34:584-95.PubMedCrossRef Higgins JP, Higgins JA, Williams G. Stress-induced abnormalities in myocardial perfusion imaging that are not related to perfusion but are of diagnostic and prognostic importance. Eur J Nucl Med Mol Imaging 2007;34:584-95.PubMedCrossRef
136.
go back to reference Underwood SR, Walton S, Laming PJ, Ell PJ, Emanuel RW, Swanton RH. Quantitative phase analysis in the assessment of coronary artery disease. Br Heart J 1989;61:14-22.PubMedPubMedCentralCrossRef Underwood SR, Walton S, Laming PJ, Ell PJ, Emanuel RW, Swanton RH. Quantitative phase analysis in the assessment of coronary artery disease. Br Heart J 1989;61:14-22.PubMedPubMedCentralCrossRef
137.
go back to reference Fauchier L, Marie O, Casset-Senon D, Babuty D, Cosnay P, Fauchier JP. Interventricular and intraventricular dyssynchrony in idiopathic dilated cardiomyopathy: a prognostic study with fourier phase analysis of radionuclide angioscintigraphy. J Am Coll Cardiol 2002;40:2022-30.PubMedCrossRef Fauchier L, Marie O, Casset-Senon D, Babuty D, Cosnay P, Fauchier JP. Interventricular and intraventricular dyssynchrony in idiopathic dilated cardiomyopathy: a prognostic study with fourier phase analysis of radionuclide angioscintigraphy. J Am Coll Cardiol 2002;40:2022-30.PubMedCrossRef
138.
go back to reference Marcassa C, Campini R, Verna E, Ceriani L, Giannuzzi P. Assessment of cardiac asynchrony by radionuclide phase analysis. Correlation with ventricular function in patients with narrow or prolonged QRS Interval. Eur J Heart Failure 2007;9:484-90.CrossRef Marcassa C, Campini R, Verna E, Ceriani L, Giannuzzi P. Assessment of cardiac asynchrony by radionuclide phase analysis. Correlation with ventricular function in patients with narrow or prolonged QRS Interval. Eur J Heart Failure 2007;9:484-90.CrossRef
139.
go back to reference Wackers F. Intersocietal Commission for the Accreditation of Nuclear Medicine Laboratories (ICANL) position statement on standardization and optimization of nuclear cardiology reports. J Nucl Cardiol 2000;7:397-400.PubMedCrossRef Wackers F. Intersocietal Commission for the Accreditation of Nuclear Medicine Laboratories (ICANL) position statement on standardization and optimization of nuclear cardiology reports. J Nucl Cardiol 2000;7:397-400.PubMedCrossRef
140.
go back to reference Cerqueira MD. The user-friendly nuclear cardiology reports: what needs to be considered and what is included. J Nucl Cardiol 1996;3:350-5.PubMedCrossRef Cerqueira MD. The user-friendly nuclear cardiology reports: what needs to be considered and what is included. J Nucl Cardiol 1996;3:350-5.PubMedCrossRef
141.
go back to reference Hendel RC, Wackers FJ, Berman DS, Ficaro E, DePuey EG, Klein L, et al. American Society of Nuclear Cardiology consensus statement: reporting of radionuclide myocardial perfusion imaging studies. J Nucl Cardiol 2006;13:e152-6.PubMedCrossRef Hendel RC, Wackers FJ, Berman DS, Ficaro E, DePuey EG, Klein L, et al. American Society of Nuclear Cardiology consensus statement: reporting of radionuclide myocardial perfusion imaging studies. J Nucl Cardiol 2006;13:e152-6.PubMedCrossRef
Metadata
Title
EANM/ESC guidelines for radionuclide imaging of cardiac function
Authors
B. Hesse
T. B. Lindhardt
W. Acampa
C. Anagnostopoulos
J. Ballinger
J. J. Bax
L. Edenbrandt
A. Flotats
G. Germano
T. Gmeiner Stopar
P. Franken
A. Kelion
A. Kjaer
D. Le Guludec
M. Ljungberg
A. F. Maenhout
C. Marcassa
J. Marving
F. McKiddie
W. M. Schaefer
L. Stegger
R. Underwood
Publication date
01-04-2008
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 4/2008
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-007-0694-9

Other articles of this Issue 4/2008

European Journal of Nuclear Medicine and Molecular Imaging 4/2008 Go to the issue