Skip to main content
Top
Published in: Annals of Vascular Surgery 6/2005

01-11-2005 | Papers Presented at the Fifteenth Annual Winter Meeting of the Peripheral Vascular Surgery Society

Duplex Ultrasound Remains a Reliable Test Even After Carotid Stenting

Authors: Brian G. Peterson, MD, G. Matthew Longo, MD, Melina R. Kibbe, MD, RVT, Jon S. Matsumura, MD, Donna Blackburn, MS, RN, RVT, Patricia Astleford, BSN, RN, RVT, Mark K. Eskandari, MD, RVT

Published in: Annals of Vascular Surgery | Issue 6/2005

Login to get access

Abstract

Transluminal arterial stenting reduces vessel compliance and may alter accurate interpretation of flow velocities. We reviewed duplex ultrasonography (DUS) following carotid stenting to identify criteria indicative of severe recurrent stenosis. This is a single-center retrospective review of 158 carotid stenoses treated with carotid angioplasty and stenting (CAS) from April 2001 to December 2004. DUS was obtained preoperatively, postoperatively, and at 3-month intervals thereafter. Peak systolic velocity (PSV) and end diastolic velocity (EDV) were analyzed. Mean follow-up was 12 months (range 1-40). Mean age was 71 ± 9 years (range 51-91; 74% men, 26% women). Three patients (1.9%) developed restenosis and one (0.6%) developed an asymptomatic occlusion during follow-up. Average preoperative PSV was 373 ± 123 cm/sec (mean ± SD) and EDV was 148 ± 63 cm/sec. Immediate postoperative PSV and EDV decreased by an average of 70% (average 118 ± 45 cm/sec) and 72% (average 32 ± 15 cm/sec), respectively. In patients free from restenosis or occlusion, these reductions (range 65-80%) were maintained throughout follow-up and remained within 1-25% of immediate postoperative values. In patients suffering restenosis or occlusion, follow-up PSV and EDV increased 34% and 28%, respectively, compared to preoperative values. PSV and EDV increased by an average of 287% and 500%, respectively, compared to immediate postoperative values. Using criteria of PSV >170 cm/sec and a 50% increase of PSV over immediate postoperative values, restenosis or occlusion was detected with 100% sensitivity and specificity in our patients. Additionally, EDV >120 cm/sec and a 50% increase in EDV over immediate postoperative values detected restenosis and occlusion with 100% sensitivity and specificity. Presumed restenosis and occlusion detected by DUS were confirmed in all cases with angiography. Restenosis or occlusion after CAS at our institution can reliably be detected by carotid duplex using cut-off values of 170 cm/sec PSV, 120 cm/sec EDV, and >50% increase over immediate postoperative values. While these criteria are applied to patients undergoing CAS at our institution, they serve only as suggested guidelines for patient populations at other centers and must be customized to each Intersocietal Commission for the Accreditation of Vascular Laboratories-accredited vascular laboratory.
Literature
1.
go back to reference Yadav JS, Wholey MH, Kuntz RE, et al. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med 2004;351:1493-1501CrossRefPubMed Yadav JS, Wholey MH, Kuntz RE, et al. Protected carotid-artery stenting versus endarterectomy in high-risk patients. N Engl J Med 2004;351:1493-1501CrossRefPubMed
2.
go back to reference Eskandari MK, Longo GM, Vijungco JD, et al. Does carotid stenting measure up to endarterectomy? A vascular surgeon’s experience. Arch Surg 2004;139:734-738CrossRefPubMed Eskandari MK, Longo GM, Vijungco JD, et al. Does carotid stenting measure up to endarterectomy? A vascular surgeon’s experience. Arch Surg 2004;139:734-738CrossRefPubMed
3.
go back to reference Golledge J, Cuming R, Ellis M, et al. Duplex imaging findings predict stenosis following carotid endarterectomy. J Vasc Surg 1997;26:43-48PubMed Golledge J, Cuming R, Ellis M, et al. Duplex imaging findings predict stenosis following carotid endarterectomy. J Vasc Surg 1997;26:43-48PubMed
4.
go back to reference Carballo RE, Towne JB, Seabrook GR, et al. An outcome analysis of carotid endarterectomy: the incidence and natural history of recurrent stenosis. J Vasc Surg 1996;23:749-754PubMed Carballo RE, Towne JB, Seabrook GR, et al. An outcome analysis of carotid endarterectomy: the incidence and natural history of recurrent stenosis. J Vasc Surg 1996;23:749-754PubMed
5.
go back to reference North American Symptomatic Carotid Endarterectomy Trial Collaborators. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 1991;325:445-453 North American Symptomatic Carotid Endarterectomy Trial Collaborators. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 1991;325:445-453
6.
go back to reference Executive Committee for the Asymptomatic Carotid Atherosclerosis Study. Endarterectomy for asymptomatic carotid artery stenosis. J A M A 1995;273:1421-1428 Executive Committee for the Asymptomatic Carotid Atherosclerosis Study. Endarterectomy for asymptomatic carotid artery stenosis. J A M A 1995;273:1421-1428
7.
go back to reference DeBray JM, Glatt B, for the International Consensus Conference, December 1994. Quantification of atheromatous stenosis in the extracranial internal carotid artery. Cerebrovasc Dis 1995;5:414-426 DeBray JM, Glatt B, for the International Consensus Conference, December 1994. Quantification of atheromatous stenosis in the extracranial internal carotid artery. Cerebrovasc Dis 1995;5:414-426
8.
go back to reference Strandness DE Jr. Duplex scanning in vascular disorders. New York: Raven, 1990 Strandness DE Jr. Duplex scanning in vascular disorders. New York: Raven, 1990
9.
go back to reference Hunink MG, Polak JF, Barlan MM, O’Leary DH. Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters. A J R Am J Roentgenol 1993;160:619-625 Hunink MG, Polak JF, Barlan MM, O’Leary DH. Detection and quantification of carotid artery stenosis: efficacy of various Doppler velocity parameters. A J R Am J Roentgenol 1993;160:619-625
10.
go back to reference Polak JF, Dobkin GR, O’Leary DH, et al. Internal carotid artery stenosis: accuracy and reproducibility of color-Doppler-assisted duplex imaging. Radiology 1989;173:793-798PubMed Polak JF, Dobkin GR, O’Leary DH, et al. Internal carotid artery stenosis: accuracy and reproducibility of color-Doppler-assisted duplex imaging. Radiology 1989;173:793-798PubMed
11.
go back to reference Sabeti S, Schillinger M, Mlekusch W, et al. Quantification of internal carotid artery stenosis with duplex US: comparative analysis of different flow velocity criteria. Radiology 2004;232:431-439PubMed Sabeti S, Schillinger M, Mlekusch W, et al. Quantification of internal carotid artery stenosis with duplex US: comparative analysis of different flow velocity criteria. Radiology 2004;232:431-439PubMed
12.
go back to reference Lal BK, Hobson RW II, Goldstein J, et al. Carotid artery stenting: is there a need to revise ultrasound velocity criteria? J Vasc Surg 2004;39:58-66CrossRefPubMed Lal BK, Hobson RW II, Goldstein J, et al. Carotid artery stenting: is there a need to revise ultrasound velocity criteria? J Vasc Surg 2004;39:58-66CrossRefPubMed
13.
go back to reference Willfort-Ehringer A, Ahmadi R, Gruber D, et al. Arterial remodeling and hemodynamics in carotid stents: a prospective duplex ultrasound study over 2 years. J Vasc Surg 2004;39:728-734CrossRefPubMed Willfort-Ehringer A, Ahmadi R, Gruber D, et al. Arterial remodeling and hemodynamics in carotid stents: a prospective duplex ultrasound study over 2 years. J Vasc Surg 2004;39:728-734CrossRefPubMed
14.
go back to reference Vernhet H, Jean B, Lust S, et al. Wall mechanics of the stented extracranial carotid artery. Stroke 2003;34:e222-e224CrossRefPubMed Vernhet H, Jean B, Lust S, et al. Wall mechanics of the stented extracranial carotid artery. Stroke 2003;34:e222-e224CrossRefPubMed
15.
go back to reference Lu CJ, Kao HL, Sun Y, et al. The hemodynamic effects of internal carotid artery stenting: a study with color-coded duplex sonography. Cerebrovasc Dis 2003;15:264-269CrossRefPubMed Lu CJ, Kao HL, Sun Y, et al. The hemodynamic effects of internal carotid artery stenting: a study with color-coded duplex sonography. Cerebrovasc Dis 2003;15:264-269CrossRefPubMed
16.
go back to reference Robbin ML, Lockhart ME, Weber TM, et al. Carotid artery stents: early and intermediate follow-up with Doppler US. Radiology 1997;205:749-756PubMed Robbin ML, Lockhart ME, Weber TM, et al. Carotid artery stents: early and intermediate follow-up with Doppler US. Radiology 1997;205:749-756PubMed
17.
go back to reference Ringer AJ, German JW, Guternam LR, Hopkins LN. Follow-up of stented carotid arteries by Doppler ultrasound. Neurosurgery 2002;51:639-643CrossRefPubMed Ringer AJ, German JW, Guternam LR, Hopkins LN. Follow-up of stented carotid arteries by Doppler ultrasound. Neurosurgery 2002;51:639-643CrossRefPubMed
Metadata
Title
Duplex Ultrasound Remains a Reliable Test Even After Carotid Stenting
Authors
Brian G. Peterson, MD
G. Matthew Longo, MD
Melina R. Kibbe, MD, RVT
Jon S. Matsumura, MD
Donna Blackburn, MS, RN, RVT
Patricia Astleford, BSN, RN, RVT
Mark K. Eskandari, MD, RVT
Publication date
01-11-2005
Publisher
Springer-Verlag
Published in
Annals of Vascular Surgery / Issue 6/2005
Print ISSN: 0890-5096
Electronic ISSN: 1615-5947
DOI
https://doi.org/10.1007/s10016-005-7976-0

Other articles of this Issue 6/2005

Annals of Vascular Surgery 6/2005 Go to the issue

Papers Presented at the Fifteenth Annual Winter Meeting of the Peripheral Vascular Surgery Society

Infrapopliteal Angioplasty for Limb Salvage in the Setting of Renal Failure: Do Results Justify Its Use?

Papers Presented at the Fifteenth Annual Winter Meeting of the Peripheral Vascular Surgery Society

Ruptured Abdominal Aortic Aneurysm: A Retrospective Assessment of Open Versus Endovascular Repair