Abstract

Objective

During radiotherapy to the head and neck, metallic dental restorations produce secondary electrons that increase dose to nearby tissue causing painful ulcers that contribute to morbidity during treatment and lead to breaks in therapy. Various protective measures have been tested with simplified phantoms and beam arrangements. Our objective was to quantitatively assess electron scatter using an anatomical phantom and modern beam configurations.

Methods

A tissue-equivalent phantom was created to simulate the oral cavity with gold crowns on opposing molars. Four-millimeter ethylene copolymer dosimetric dental stents were produced. The phantom was placed in a water bath to simulate soft tissue. Radiation was delivered in opposed lateral, nine-field intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) configurations. A GafChromic EBT3 film was used to simulate the mucosal surfaces of the tongue and the buccal mucosa. The film readings were then converted to isodose plots using DoseLab.

Results

With opposed beams, a 32 % reduction in maximum dose was measured in the occlusal plane with the use of stents. In the nine-field IMRT and VMAT plans, maximum dose to the adjacent film was reduced by approximately 40 % with the use of the dental stent.

Conclusions

This approximately 40 % dose reduction implies that patients’ oral mucosae adjacent to dental fixtures could receive more than 100 Gy during a course of definitive radiotherapy to the head and neck without dental stents. In this era of increasing IMRT/VMAT utilization, our results emphasize the value of stent use to improve morbidity and reduce treatment breaks for patients undergoing head and neck radiotherapy.
Literature
1.
9.
go back to reference Trotti A, Bellm LA, Epstein JB, et al. (2003) Mucositis incidence, severity and associated outcomes in patients with head and neck cancer receiving radiotherapy with or without chemotherapy: a systematic literature review. Radiother Oncol J Eur Soc Ther Radiol Oncol 66:253–262CrossRef Trotti A, Bellm LA, Epstein JB, et al. (2003) Mucositis incidence, severity and associated outcomes in patients with head and neck cancer receiving radiotherapy with or without chemotherapy: a systematic literature review. Radiother Oncol J Eur Soc Ther Radiol Oncol 66:253–262CrossRef
10.
go back to reference Bese NS, Hendry J, Jeremic B (2007) Effects of prolongation of overall treatment time due to unplanned interruptions during radiotherapy of different tumor sites and practical methods for compensation. Int J Radiat Oncol 68:654–661. doi:10.1016/j.ijrobp.2007.03.010 CrossRef Bese NS, Hendry J, Jeremic B (2007) Effects of prolongation of overall treatment time due to unplanned interruptions during radiotherapy of different tumor sites and practical methods for compensation. Int J Radiat Oncol 68:654–661. doi:10.​1016/​j.​ijrobp.​2007.​03.​010 CrossRef
12.
go back to reference Nadrowitz R, Feyerabend T (2001) Backscatter dose from metallic materials due to obliquely incident high-energy photon beams. Med Phys 28:959–965CrossRefPubMed Nadrowitz R, Feyerabend T (2001) Backscatter dose from metallic materials due to obliquely incident high-energy photon beams. Med Phys 28:959–965CrossRefPubMed
13.
go back to reference Beyzadeoglu M, Dirican B, Oysul K, et al. (2006) Evaluation of scatter dose of dental titanium implants exposed to photon beams of different energies and irradiation angles in head and neck radiotherapy. Dentomaxillofacial Radiol 35:14–17. doi:10.1259/dmfr/28125805 CrossRef Beyzadeoglu M, Dirican B, Oysul K, et al. (2006) Evaluation of scatter dose of dental titanium implants exposed to photon beams of different energies and irradiation angles in head and neck radiotherapy. Dentomaxillofacial Radiol 35:14–17. doi:10.​1259/​dmfr/​28125805 CrossRef
15.
go back to reference Spirydovich S, Papiez L, Langer M, et al. (2006) High density dental materials and radiotherapy planning: comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements. Radiother Oncol 81:309–314. doi:10.1016/j.radonc.2006.10.010 CrossRefPubMed Spirydovich S, Papiez L, Langer M, et al. (2006) High density dental materials and radiotherapy planning: comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements. Radiother Oncol 81:309–314. doi:10.​1016/​j.​radonc.​2006.​10.​010 CrossRefPubMed
17.
go back to reference Thilmann C, Adamietz IA, Ramm U, et al. (1996) In vivo dose increase in the presence of dental alloys during 60Co-gamma-ray therapy of the oral cavity. Med Dosim Off J Am Assoc Med Dosim 21:149–154 Thilmann C, Adamietz IA, Ramm U, et al. (1996) In vivo dose increase in the presence of dental alloys during 60Co-gamma-ray therapy of the oral cavity. Med Dosim Off J Am Assoc Med Dosim 21:149–154
18.
go back to reference Chin DWH, Treister N, Friedland B, et al. (2009) Effect of dental restorations and prostheses on radiotherapy dose distribution: a Monte Carlo study. J Appl Clin Med Phys 10 Chin DWH, Treister N, Friedland B, et al. (2009) Effect of dental restorations and prostheses on radiotherapy dose distribution: a Monte Carlo study. J Appl Clin Med Phys 10
20.
22.
go back to reference Das IJ, Kahn FM (1989) Backscatter dose perturbation at high atomic number interfaces in megavoltage photon beams. Med Phys 16:367–375CrossRefPubMed Das IJ, Kahn FM (1989) Backscatter dose perturbation at high atomic number interfaces in megavoltage photon beams. Med Phys 16:367–375CrossRefPubMed
23.
Metadata
Title
Dosimetric verification of dental stent efficacy in head and neck radiation therapy using modern radiation therapy techniques: quality of life and treatment compliance implications
Authors
Eric Allan
Lanchun Lu
Hooman Hamedani
Virginia Diavolitsis
Aashish Bhatt
John Grecula
Jessica Wobb
Tiffany Kessling
Meade Van Putten
Dukagjin Blakaj
Publication date
01-12-2016
Publisher
Springer Berlin Heidelberg
Published in
Journal of Radiation Oncology / Issue 4/2016
Print ISSN: 1948-7894
Electronic ISSN: 1948-7908
DOI
https://doi.org/10.1007/s13566-016-0268-1

Other articles of this Issue 4/2016

Journal of Radiation Oncology 4/2016 Go to the issue
Webinar | 19-02-2024 | 17:30 (CET)

Keynote webinar | Spotlight on antibody–drug conjugates in cancer

Antibody–drug conjugates (ADCs) are novel agents that have shown promise across multiple tumor types. Explore the current landscape of ADCs in breast and lung cancer with our experts, and gain insights into the mechanism of action, key clinical trials data, existing challenges, and future directions.

Dr. Véronique Diéras
Prof. Fabrice Barlesi
Developed by: Springer Medicine