Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 11/2012

01-11-2012 | Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Does CT-Based Navigation Improve the Long-Term Survival in Ceramic-on-Ceramic THA?

Authors: Nobuhiko Sugano, MD, PhD, Masaki Takao, MD, PhD, Takashi Sakai, MD, PhD, Takashi Nishii, MD, PhD, Hidenobu Miki, MD, PhD

Published in: Clinical Orthopaedics and Related Research® | Issue 11/2012

Login to get access

Abstract

Background

Although navigated THA provides improved precision in implant positioning and alignment, it is unclear whether these translate into long-term implant survival.

Questions/Purposes

We compared survivorship, dislocation rate, and incidence of radiographic failures such as loosening and bearing breakage after THA with and without navigation at a minimum 10-year followup.

Methods

We retrospectively reviewed 46 patients (60 hips) and 97 patients (120 hips) receiving THA with or without a CT-based navigation system, respectively, using cementless THA ceramic-on-ceramic bearing couples. There were no differences in age, sex, diagnosis, height, weight, BMI, or preoperative clinical score between groups. We evaluated survivorship, mode of acetabular and femoral component fixation, osteolysis, and implant wear or breakage at a minimum followup of 10 years (average, 11 years; range, 10–13 years).

Results

Survival at 13 years was 100% with navigation and 95.6% (95% CI, 88.4%–98.4%) without navigation. With navigation, all cups were placed within a zone of 40° (range, 30°–50°) of radiographic inclination and 15° (range, 5°–15°) of radiographic anteversion; without navigation, 31 cups (26%) were placed outside this zone. Hips treated without navigation had a higher rate of dislocation (8%) than the navigated cases (0%). Revision was performed in four nonnavigated cases, all of which showed evidence of neck impingement on the ceramic liner. Moreover, seven other cases without navigation showed posterior neck erosion on radiographs. These 11 impingement-related mechanical complications correlated with cup malorientation, and the incidence of impingement-related complications was higher in nonnavigated cases.

Conclusions

Navigation reduced the rates of dislocation and impingement-related mechanical complications leading to revision in cementless THA using ceramic-on-ceramic bearing couples over a minimum 10-year followup.

Level of Evidence

Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop Relat Res. 2004;429:73–79.PubMedCrossRef Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop Relat Res. 2004;429:73–79.PubMedCrossRef
2.
go back to reference Berry DJ, von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2456–2463.PubMedCrossRef Berry DJ, von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg Am. 2005;87:2456–2463.PubMedCrossRef
3.
go back to reference Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988;70:337–346.PubMed Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988;70:337–346.PubMed
4.
go back to reference Callanan MC, Jarrett B, Bragdon CR, Zurakowski D, Rubash HE, Freiberg AA, Malchau H. The John Charnley Award. Risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res. 2011;469:319–329.PubMedCrossRef Callanan MC, Jarrett B, Bragdon CR, Zurakowski D, Rubash HE, Freiberg AA, Malchau H. The John Charnley Award. Risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res. 2011;469:319–329.PubMedCrossRef
5.
go back to reference DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T. The Otto Aufranc Award. Image-guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22.PubMedCrossRef DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T. The Otto Aufranc Award. Image-guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22.PubMedCrossRef
6.
go back to reference Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants: the femoral side. Clin Orthop Relat Res. 1990;261:63–81.PubMed Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants: the femoral side. Clin Orthop Relat Res. 1990;261:63–81.PubMed
7.
go back to reference Furmanski J, Anderson M, Bal S, Greenwald AS, Halley D, Penenberg B, Ries M, Pruitt L. Clinical fracture of cross-linked UHMWPE acetabular liners. Biomaterials. 2009;30:5572–5582.PubMedCrossRef Furmanski J, Anderson M, Bal S, Greenwald AS, Halley D, Penenberg B, Ries M, Pruitt L. Clinical fracture of cross-linked UHMWPE acetabular liners. Biomaterials. 2009;30:5572–5582.PubMedCrossRef
8.
go back to reference Haaker RG, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007;22:151–159.PubMedCrossRef Haaker RG, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007;22:151–159.PubMedCrossRef
9.
go back to reference Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br. 2006;88:163–167.PubMedCrossRef Kalteis T, Handel M, Bathis H, Perlick L, Tingart M, Grifka J. Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation? J Bone Joint Surg Br. 2006;88:163–167.PubMedCrossRef
10.
go back to reference Kwon MS, Kuskowski M, Mulhall KJ, Macaulay W, Brown TE, Saleh KJ. Does surgical approach affect total hip arthroplasty dislocation rates? Clin Orthop Relat Res. 2006;447:34–38.PubMedCrossRef Kwon MS, Kuskowski M, Mulhall KJ, Macaulay W, Brown TE, Saleh KJ. Does surgical approach affect total hip arthroplasty dislocation rates? Clin Orthop Relat Res. 2006;447:34–38.PubMedCrossRef
11.
go back to reference Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2008;90:1143–1151.PubMed Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2008;90:1143–1151.PubMed
12.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed
13.
go back to reference Merle d’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475. Merle d’Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954;36:451–475.
14.
go back to reference Miki H, Yamanashi W, Nishii T, Sato Y, Yoshikawa H, Sugano N. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty. 2007;22:946–952.PubMedCrossRef Miki H, Yamanashi W, Nishii T, Sato Y, Yoshikawa H, Sugano N. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty. 2007;22:946–952.PubMedCrossRef
15.
go back to reference Murphy SB, Ecker TM, Tannast M. THA performed using conventional and navigated tissue-preserving techniques. Clin Orthop Relat Res. 2006;453:160–167.PubMedCrossRef Murphy SB, Ecker TM, Tannast M. THA performed using conventional and navigated tissue-preserving techniques. Clin Orthop Relat Res. 2006;453:160–167.PubMedCrossRef
16.
go back to reference Najarian BC, Kilgore JE, Markel DC. Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. J Arthroplasty. 2009;24:15–21.PubMedCrossRef Najarian BC, Kilgore JE, Markel DC. Evaluation of component positioning in primary total hip arthroplasty using an imageless navigation device compared with traditional methods. J Arthroplasty. 2009;24:15–21.PubMedCrossRef
17.
go back to reference Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004;426:159–163.PubMedCrossRef Nogler M, Kessler O, Prassl A, Donnelly B, Streicher R, Sledge JB, Krismer M. Reduced variability of acetabular cup positioning with use of an imageless navigation system. Clin Orthop Relat Res. 2004;426:159–163.PubMedCrossRef
18.
go back to reference Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty: a prospective, randomized, controlled study. J Bone Joint Surg Am. 2007;89:494–499.PubMedCrossRef Parratte S, Argenson JN. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty: a prospective, randomized, controlled study. J Bone Joint Surg Am. 2007;89:494–499.PubMedCrossRef
19.
go back to reference Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty. 2005;20:427–435.PubMedCrossRef Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty. 2005;20:427–435.PubMedCrossRef
20.
go back to reference Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S. Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br. 2007;89:455–460.PubMedCrossRef Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S. Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br. 2007;89:455–460.PubMedCrossRef
21.
go back to reference Sugano N, Sasama T, Sato Y, Nakajima Y, Nishii T, Yonenobu K, Tamura S, Ochi T. Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg. 2001;6:195–203.PubMedCrossRef Sugano N, Sasama T, Sato Y, Nakajima Y, Nishii T, Yonenobu K, Tamura S, Ochi T. Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg. 2001;6:195–203.PubMedCrossRef
22.
go back to reference Wixson RL, MacDonald MA. Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty. 2005;20(suppl 3):51–56.PubMedCrossRef Wixson RL, MacDonald MA. Total hip arthroplasty through a minimal posterior approach using imageless computer-assisted hip navigation. J Arthroplasty. 2005;20(suppl 3):51–56.PubMedCrossRef
23.
go back to reference Wroblewski BM, Siney PD, Fleming PA. Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty. J Arthroplasty. 2009;24:10–14.PubMedCrossRef Wroblewski BM, Siney PD, Fleming PA. Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty. J Arthroplasty. 2009;24:10–14.PubMedCrossRef
24.
go back to reference Zicat B, Engh CA, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am. 1995;77:432–439.PubMed Zicat B, Engh CA, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am. 1995;77:432–439.PubMed
Metadata
Title
Does CT-Based Navigation Improve the Long-Term Survival in Ceramic-on-Ceramic THA?
Authors
Nobuhiko Sugano, MD, PhD
Masaki Takao, MD, PhD
Takashi Sakai, MD, PhD
Takashi Nishii, MD, PhD
Hidenobu Miki, MD, PhD
Publication date
01-11-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 11/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-012-2378-4

Other articles of this Issue 11/2012

Clinical Orthopaedics and Related Research® 11/2012 Go to the issue

Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Acetabular Distraction: An Alternative for Severe Defects with Chronic Pelvic Discontinuity?

Symposium: Papers Presented at the 2011 Meeting of the International Hip Society

Cup Press Fit in Uncemented THA Depends on Sex, Acetabular Shape, and Surgical Technique