Abstract

Background

The outcomes for volar locking plate (VLP) and external fixation (EF) in distal radius fracture cases remain controversial. The current study of randomized controlled trials (RCTs) aimed to assess VLP and EF, which might benefit distal radius fracture cases.

Methods

RCTs comparing VLP and EF in distal radius fracture cases, until 18 March 2020, were systematically reviewed and summarized. The functional and radiographic outcomes, together with complications, for distal radius fracture cases, were evaluated.

Results

In total, 12 studies comprising 1205 distal radius fracture cases were included. The VLP group had observed lower disability in the arm shoulder and hand score (DASH) at 3rd, 6th, and 12th -month post-operation, with the mean differences (MDs) of − 10.43 (95 % CI = − 15.77 to − 5.08, P < 0.01), − 3.48 (95 % CI = − 6.37 to − 0.59, P = 0.02), and − 4.13 (95 % CI = − 6.94 to − 1.33, P < 0.01), respectively. The VLP group also had lower visual analog scale scores (VAS) compared to the EF group, with MDs of − 0.10 (95 % CI = − 0.18 to − 0.03, P < 0.01) for the former at 6th -month post-operation. Also, the EF group exhibited better grip strength than that in the VLP group, with MD of 12.48 (95 % CI = 7.00–17.95, P < 0.01) at the 3rd month and 4.54 (95 % CI = 0.31–8.76, P = 0.04) at 6th month. No significant differences in radiographic outcomes were observed between the VLP and EF groups (P > 0.05). The VLP group had a lower complication rate than that in the EF group.

Conclusions

VLP had a lower DASH score and VAS score but with lower grip strength. No significant differences in radiographic outcomes were observed. VLP had a lower complication rate than that of EF.
Appendix
Available only for authorised users
Literature
1.
go back to reference Singer BR, McLauchlan GJ, Robinson CM, Christie J: Epidemiology of fractures in 15,000 adults: the influence of age and gender. J Bone Joint Surg Br 1998, 80(2):243–248.PubMedCrossRef Singer BR, McLauchlan GJ, Robinson CM, Christie J: Epidemiology of fractures in 15,000 adults: the influence of age and gender. J Bone Joint Surg Br 1998, 80(2):243–248.PubMedCrossRef
2.
go back to reference Paksima N, Panchal A, Posner MA, Green SM, Mehiman CT, Hiebert R: A meta-analysis of the literature on distal radius fractures: review of 615 articles. Bull Hosp Jt Dis 2004, 62(1–2):40–46.PubMed Paksima N, Panchal A, Posner MA, Green SM, Mehiman CT, Hiebert R: A meta-analysis of the literature on distal radius fractures: review of 615 articles. Bull Hosp Jt Dis 2004, 62(1–2):40–46.PubMed
3.
go back to reference Kawaguchi S, Sawada K, Nabeta Y, Hayakawa M, Aoki M: Recurrent dorsal angulation of the distal radius fracture during dynamic external fixation. J Hand Surg Am 1998, 23(5):920–925.PubMedCrossRef Kawaguchi S, Sawada K, Nabeta Y, Hayakawa M, Aoki M: Recurrent dorsal angulation of the distal radius fracture during dynamic external fixation. J Hand Surg Am 1998, 23(5):920–925.PubMedCrossRef
4.
go back to reference Wolf JC, Weil WM, Hanel DP, Trumble TE: A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures. J Hand Surg Am 2006, 31(10):1578–1586.PubMedCrossRef Wolf JC, Weil WM, Hanel DP, Trumble TE: A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures. J Hand Surg Am 2006, 31(10):1578–1586.PubMedCrossRef
5.
go back to reference Orbay JL, Fernandez DL: Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 2002, 27(2):205–215.PubMedCrossRef Orbay JL, Fernandez DL: Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am 2002, 27(2):205–215.PubMedCrossRef
6.
go back to reference Downing ND, Karantana A: A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 2008, 90(10):1271–1275.PubMedCrossRef Downing ND, Karantana A: A revolution in the management of fractures of the distal radius? J Bone Joint Surg Br 2008, 90(10):1271–1275.PubMedCrossRef
7.
go back to reference Abramo A, Kopylov P, Geijer M, Tägil M: Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients. Acta Orthop 2009, 80(4):478–485.PubMedPubMedCentralCrossRef Abramo A, Kopylov P, Geijer M, Tägil M: Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients. Acta Orthop 2009, 80(4):478–485.PubMedPubMedCentralCrossRef
8.
go back to reference Kandemir U, Matityahu A, Desai R, Puttlitz C: Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study. J Orthop Trauma 2008, 22(9):605–610.PubMedCrossRef Kandemir U, Matityahu A, Desai R, Puttlitz C: Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study. J Orthop Trauma 2008, 22(9):605–610.PubMedCrossRef
9.
go back to reference Cooper EO, Segalman KA, Parks BG, Sharma KM, Nguyen A: Biomechanical stability of a volar locking-screw plate versus fragment-specific fixation in a distal radius fracture model. Am J Orthop (Belle Mead NJ) 2007, 36(4):E46–49. Cooper EO, Segalman KA, Parks BG, Sharma KM, Nguyen A: Biomechanical stability of a volar locking-screw plate versus fragment-specific fixation in a distal radius fracture model. Am J Orthop (Belle Mead NJ) 2007, 36(4):E46–49.
10.
go back to reference Wilcke MK, Abbaszadegan H, Adolphson PY: Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop 2011, 82(1):76–81.PubMedPubMedCentralCrossRef Wilcke MK, Abbaszadegan H, Adolphson PY: Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop 2011, 82(1):76–81.PubMedPubMedCentralCrossRef
11.
go back to reference Jeudy J, Steiger V, Boyer P, Cronier P, Bizot P, Massin P: Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation ‘versus’ locked volar plating. Injury 2012, 43(2):174–179.PubMedCrossRef Jeudy J, Steiger V, Boyer P, Cronier P, Bizot P, Massin P: Treatment of complex fractures of the distal radius: a prospective randomised comparison of external fixation ‘versus’ locked volar plating. Injury 2012, 43(2):174–179.PubMedCrossRef
12.
go back to reference Walenkamp MM, Bentohami A, Beerekamp MS, Peters RW, van der Heiden R, Goslings JC, Schep NW: Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis. Strategies in trauma and limb reconstruction 2013, 8(2):67–75.PubMedPubMedCentralCrossRef Walenkamp MM, Bentohami A, Beerekamp MS, Peters RW, van der Heiden R, Goslings JC, Schep NW: Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis. Strategies in trauma and limb reconstruction 2013, 8(2):67–75.PubMedPubMedCentralCrossRef
13.
go back to reference Li-hai Z, Ya-nan W, Zhi M, Li-cheng Z, Hong-da L, Huan Y, Xiao-xie L, Pei-fu T: Volar locking plate versus external fixation for the treatment of unstable distal radial fractures: a meta-analysis of randomized controlled trials. J Surg Res 2015, 193(1):324–333.PubMedCrossRef Li-hai Z, Ya-nan W, Zhi M, Li-cheng Z, Hong-da L, Huan Y, Xiao-xie L, Pei-fu T: Volar locking plate versus external fixation for the treatment of unstable distal radial fractures: a meta-analysis of randomized controlled trials. J Surg Res 2015, 193(1):324–333.PubMedCrossRef
14.
go back to reference Shukla R, Jain RK, Sharma NK, Kumar R: External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes. J Orthop Traumatol 2014, 15(4):265–270.PubMedPubMedCentralCrossRef Shukla R, Jain RK, Sharma NK, Kumar R: External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes. J Orthop Traumatol 2014, 15(4):265–270.PubMedPubMedCentralCrossRef
15.
go back to reference Roh YH, Lee BK, Baek JR, Noh JH, Gong HS, Baek GH: A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. J Hand Surg Am 2015, 40(1):34–41.PubMedCrossRef Roh YH, Lee BK, Baek JR, Noh JH, Gong HS, Baek GH: A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures. J Hand Surg Am 2015, 40(1):34–41.PubMedCrossRef
16.
go back to reference Mellstrand Navarro C, Ahrengart L, Törnqvist H, Ponzer S: Volar Locking Plate or External Fixation With Optional Addition of K-Wires for Dorsally Displaced Distal Radius Fractures: A Randomized Controlled Study. J Orthop Trauma 2016, 30(4):217–224.PubMedCrossRef Mellstrand Navarro C, Ahrengart L, Törnqvist H, Ponzer S: Volar Locking Plate or External Fixation With Optional Addition of K-Wires for Dorsally Displaced Distal Radius Fractures: A Randomized Controlled Study. J Orthop Trauma 2016, 30(4):217–224.PubMedCrossRef
17.
go back to reference Hammer OL, Clementsen S, Hast J, Šaltytė Benth J, Madsen JE, Randsborg PH: Volar Locking Plates Versus Augmented External Fixation of Intra-Articular Distal Radial Fractures: Functional Results from a Randomized Controlled Trial. J Bone Joint Surg Am 2019, 101(4):311–321.PubMedCrossRef Hammer OL, Clementsen S, Hast J, Šaltytė Benth J, Madsen JE, Randsborg PH: Volar Locking Plates Versus Augmented External Fixation of Intra-Articular Distal Radial Fractures: Functional Results from a Randomized Controlled Trial. J Bone Joint Surg Am 2019, 101(4):311–321.PubMedCrossRef
18.
go back to reference Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D: The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 2009, 339:b2700.PubMedPubMedCentralCrossRef Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, Clarke M, Devereaux PJ, Kleijnen J, Moher D: The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 2009, 339:b2700.PubMedPubMedCentralCrossRef
19.
go back to reference Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA et al.: The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 2011, 343:d5928.PubMedPubMedCentralCrossRef Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA et al.: The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials. BMJ 2011, 343:d5928.PubMedPubMedCentralCrossRef
20.
go back to reference Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ: Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 1996, 17(1):1–12.PubMedCrossRef Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ: Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 1996, 17(1):1–12.PubMedCrossRef
21.
go back to reference SD S: Statistical Evidence in Medical Trials: What Do the Data Really Tell Us. Oxford University Press 2006. SD S: Statistical Evidence in Medical Trials: What Do the Data Really Tell Us. Oxford University Press 2006.
23.
go back to reference Begg CB, Mazumdar M: Operating characteristics of a rank correlation test for publication bias. Biometrics 1994, 50(4):1088–1101.PubMedCrossRef Begg CB, Mazumdar M: Operating characteristics of a rank correlation test for publication bias. Biometrics 1994, 50(4):1088–1101.PubMedCrossRef
24.
go back to reference Seagroatt V,., Stratton I,. Bias in meta-analysis detected by a simple, graphical test. Test had 10 % false positive rate. Bmj British Medical Journal 1997, 316(7129):469–471. Seagroatt V,., Stratton I,. Bias in meta-analysis detected by a simple, graphical test. Test had 10 % false positive rate. Bmj British Medical Journal 1997, 316(7129):469–471.
25.
go back to reference Egol K, Walsh M, Tejwani N, McLaurin T, Wynn C, Paksima N: Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial. J Bone Joint Surg Br 2008, 90(9):1214–1221.PubMedCrossRef Egol K, Walsh M, Tejwani N, McLaurin T, Wynn C, Paksima N: Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial. J Bone Joint Surg Br 2008, 90(9):1214–1221.PubMedCrossRef
26.
go back to reference Wei DH, Raizman NM, Bottino CJ, Jobin CM, Strauch RJ, Rosenwasser MP: Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial. J Bone Joint Surg Am 2009, 91(7):1568–1577.PubMedCrossRef Wei DH, Raizman NM, Bottino CJ, Jobin CM, Strauch RJ, Rosenwasser MP: Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial. J Bone Joint Surg Am 2009, 91(7):1568–1577.PubMedCrossRef
27.
go back to reference Gradl G, Gradl G, Wendt M, Mittlmeier T, Kundt G, Jupiter JB: Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius. Arch Orthop Trauma Surg 2013, 133(5):595–602.PubMedCrossRef Gradl G, Gradl G, Wendt M, Mittlmeier T, Kundt G, Jupiter JB: Non-bridging external fixation employing multiplanar K-wires versus volar locked plating for dorsally displaced fractures of the distal radius. Arch Orthop Trauma Surg 2013, 133(5):595–602.PubMedCrossRef
28.
go back to reference Williksen JH, Frihagen F, Hellund JC, Kvernmo HD, Husby T: Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study. J Hand Surg Am 2013, 38(8):1469–1476.PubMedCrossRef Williksen JH, Frihagen F, Hellund JC, Kvernmo HD, Husby T: Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study. J Hand Surg Am 2013, 38(8):1469–1476.PubMedCrossRef
29.
go back to reference Karantana A, Downing ND, Forward DP, Hatton M, Taylor AM, Scammell BE, Moran CG, Davis TR: Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial. J Bone Joint Surg Am 2013, 95(19):1737–1744.PubMedCrossRef Karantana A, Downing ND, Forward DP, Hatton M, Taylor AM, Scammell BE, Moran CG, Davis TR: Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial. J Bone Joint Surg Am 2013, 95(19):1737–1744.PubMedCrossRef
30.
go back to reference Chung KC, Malay S, Shauver MJ, Kim HM: Assessment of Distal Radius Fracture Complications Among Adults 60 Years or Older: A Secondary Analysis of the WRIST Randomized Clinical Trial. JAMA network open 2019, 2(1):e187053.PubMedPubMedCentralCrossRef Chung KC, Malay S, Shauver MJ, Kim HM: Assessment of Distal Radius Fracture Complications Among Adults 60 Years or Older: A Secondary Analysis of the WRIST Randomized Clinical Trial. JAMA network open 2019, 2(1):e187053.PubMedPubMedCentralCrossRef
31.
go back to reference Gouk CJC, Bindra RR, Tarrant DJ, Thomas MJE: Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis. J Hand Surg Eur Vol 2018, 43(9):954–960.PubMedCrossRef Gouk CJC, Bindra RR, Tarrant DJ, Thomas MJE: Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis. J Hand Surg Eur Vol 2018, 43(9):954–960.PubMedCrossRef
32.
go back to reference Fu Q, Zhu L, Yang P, Chen A: Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials. Indian J Orthop 2018, 52(6):602–610.PubMedPubMedCentralCrossRef Fu Q, Zhu L, Yang P, Chen A: Volar Locking Plate versus External Fixation for Distal Radius Fractures: A Meta-analysis of Randomized Controlled Trials. Indian J Orthop 2018, 52(6):602–610.PubMedPubMedCentralCrossRef
33.
go back to reference Diaz-Garcia RJ, Oda T, Shauver MJ, Chung KC: A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly. J Hand Surg Am 2011, 36(5):824–835 e822.PubMedPubMedCentralCrossRef Diaz-Garcia RJ, Oda T, Shauver MJ, Chung KC: A systematic review of outcomes and complications of treating unstable distal radius fractures in the elderly. J Hand Surg Am 2011, 36(5):824–835 e822.PubMedPubMedCentralCrossRef
34.
go back to reference Landgren M, Jerrhag D, Tagil M, Kopylov P, Geijer M, Abramo A: External or internal fixation in the treatment of non-reducible distal radial fractures? Acta Orthop 2011, 82(5):610–613.PubMedPubMedCentralCrossRef Landgren M, Jerrhag D, Tagil M, Kopylov P, Geijer M, Abramo A: External or internal fixation in the treatment of non-reducible distal radial fractures? Acta Orthop 2011, 82(5):610–613.PubMedPubMedCentralCrossRef
35.
go back to reference Williksen JH, Husby T, Hellund JC, Kvernmo HD, Rosales C, Frihagen F: External Fixation and Adjuvant Pins Versus Volar Locking Plate Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study With a 5-Year Follow-Up. J Hand Surg Am 2015, 40(7):1333–1340.PubMedCrossRef Williksen JH, Husby T, Hellund JC, Kvernmo HD, Rosales C, Frihagen F: External Fixation and Adjuvant Pins Versus Volar Locking Plate Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study With a 5-Year Follow-Up. J Hand Surg Am 2015, 40(7):1333–1340.PubMedCrossRef
36.
go back to reference Kara A, Celik H, Oc Y, Uzun M, Erdil M, Tetik C: Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates. Acta Orthop Traumatol Turc 2016, 50(6):665–669.PubMedPubMedCentralCrossRef Kara A, Celik H, Oc Y, Uzun M, Erdil M, Tetik C: Flexor tendon complications in comminuted distal radius fractures treated with anatomic volar rim locking plates. Acta Orthop Traumatol Turc 2016, 50(6):665–669.PubMedPubMedCentralCrossRef
37.
go back to reference Brogan DM, Richard MJ, Ruch D, Kakar S: Management of Severely Comminuted Distal Radius Fractures. J Hand Surg Am 2015, 40(9):1905–1914.PubMedCrossRef Brogan DM, Richard MJ, Ruch D, Kakar S: Management of Severely Comminuted Distal Radius Fractures. J Hand Surg Am 2015, 40(9):1905–1914.PubMedCrossRef
38.
go back to reference Duprat A, Diaz J, Vernet P, Gouzou S, Facca S, Igeta Y, Liverneaux P: Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization. J Wrist Surg 2018, 7(3):237–242.PubMedPubMedCentralCrossRef Duprat A, Diaz J, Vernet P, Gouzou S, Facca S, Igeta Y, Liverneaux P: Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization. J Wrist Surg 2018, 7(3):237–242.PubMedPubMedCentralCrossRef
Metadata
Title
Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials
Authors
Qi Gou
Xiong Xiong
Dan Cao
Yuanliang He
Xu Li
Publication date
01-12-2021
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2021
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-021-04312-7

Other articles of this Issue 1/2021

BMC Musculoskeletal Disorders 1/2021 Go to the issue