Abstract

Background

The precise influence of plate position on clinical outcomes in the context of volar fixed-angle plating for distal radius fractures is not fully understood. This article aims to investigate the influence of plate position on clinical results, and functional outcomes in patients treated with volar fixed plating for distal radius fractures.

Methods

A total of 58 patients with 64 distal radius fractures were included in the study. Patient demographics, fracture characteristics, surgical details, and radiographic data were collected. Post-operative AP and Lat views of all patients taken on the first day after surgery were evaluated. Volar Tilt, Radial Inclination and Radial Height measurements were used as reduction criteria. In the follow-up, the patients were called for their last control, flexion and extension angles of the wrist and Mayo Wrist Scores, the distance of the plate to the joint line and the angle between the plate and the radial shaft were measured and recorded.

Results

A total of 64 distal radius fractures, with a mean age of 46.9 years, and the mean follow-up period 24.9 months were included in this study. There was a significant relationship between the Radial Inclination and Plate-Shaft Angle variables and the Mayo Wrist Score at a 99% confidence interval. Additionally, a relationship was observed between the Radial Height variable and the Mayo Score at a 90% confidence interval. A significant positive association was observed between radial inclination and achieving a Good-to-Excellent Mayo score (OR = 1.28, 95% CI [1.08–1.51], p = 0.004). Plate distance to joint line demonstrated a marginally significant positive association with a Good-to-Excellent Mayo score (OR = 1.31, 95% CI [0.97–1.77], p = 0.077). Univariate analysis revealed a significant negative association between plate-shaft angle and achieving a Good-to-Excellent Mayo score (OR = 0.71, 95% CI [0.52–0.99], p = 0.045). This negative association remained statistically significant in the multivariate analysis (p = 0.016).

Conclusion

Radial inclination, plate distance to joint line, and angle between plate and radius shaft were identified as significant factors associated with improved Mayo Wrist Scores.
Literature
2.
go back to reference Rozental TD, et al. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation: a prospective randomized trial. JBJS. 2009;91(8):1837–46.CrossRef Rozental TD, et al. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation: a prospective randomized trial. JBJS. 2009;91(8):1837–46.CrossRef
4.
go back to reference Ochen Y, et al. Operative vs nonoperative treatment of distal radius fractures in adults: a systematic review and meta-analysis. JAMA Netw open. 2020;3(4):e203497–203497.CrossRefPubMedPubMedCentral Ochen Y, et al. Operative vs nonoperative treatment of distal radius fractures in adults: a systematic review and meta-analysis. JAMA Netw open. 2020;3(4):e203497–203497.CrossRefPubMedPubMedCentral
5.
go back to reference Ruch DS, Papadonikolakis A. Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg. 2006;31(1):9–16.CrossRef Ruch DS, Papadonikolakis A. Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg. 2006;31(1):9–16.CrossRef
7.
go back to reference Grewal R, MacDermid JC. The risk of adverse outcomes in extra-articular distal radius fractures is increased with malalignment in patients of all ages but mitigated in older patients. J Hand Surg. 2007;32(7):962–70.CrossRef Grewal R, MacDermid JC. The risk of adverse outcomes in extra-articular distal radius fractures is increased with malalignment in patients of all ages but mitigated in older patients. J Hand Surg. 2007;32(7):962–70.CrossRef
8.
go back to reference Jensen J, et al. Distal radius fractures and radiographic assessment: a systematic review of measurement accuracy. Acta Radiol. 2019;60(11):1482–9.CrossRefPubMed Jensen J, et al. Distal radius fractures and radiographic assessment: a systematic review of measurement accuracy. Acta Radiol. 2019;60(11):1482–9.CrossRefPubMed
9.
go back to reference Anzarut A, et al. Radiologic and patient-reported functional outcomes in an elderly cohort with conservatively treated distal radius fractures. J Hand Surg. 2004;29(6):1121–7.CrossRef Anzarut A, et al. Radiologic and patient-reported functional outcomes in an elderly cohort with conservatively treated distal radius fractures. J Hand Surg. 2004;29(6):1121–7.CrossRef
10.
go back to reference Wurtzel CNW, et al. Effects of volar tilt, wrist extension, and plate position on contact between flexor pollicis longus tendon and volar plate. J Hand Surg. 2017;42(12):996–1001.CrossRef Wurtzel CNW, et al. Effects of volar tilt, wrist extension, and plate position on contact between flexor pollicis longus tendon and volar plate. J Hand Surg. 2017;42(12):996–1001.CrossRef
11.
go back to reference Mulders MA, et al. Association between radiological and patient-reported outcome in adults with a displaced distal radius fracture: a systematic review and meta-analysis. J Hand Surg. 2018;43(8):710–9. e5.CrossRef Mulders MA, et al. Association between radiological and patient-reported outcome in adults with a displaced distal radius fracture: a systematic review and meta-analysis. J Hand Surg. 2018;43(8):710–9. e5.CrossRef
12.
go back to reference Drobetz H, et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg. 2006;31(4):615. e1-615. e9.CrossRef Drobetz H, et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction—a biomechanic study in a cadaveric model. J Hand Surg. 2006;31(4):615. e1-615. e9.CrossRef
13.
go back to reference Tanaka Y, et al. Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg. 2011;36(11):1790–7.CrossRef Tanaka Y, et al. Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg. 2011;36(11):1790–7.CrossRef
14.
15.
go back to reference Ali M, et al. Association between distal radial fracture malunion and patient-reported activity limitations: a long-term follow-up. JBJS. 2018;100(8):633–9.CrossRef Ali M, et al. Association between distal radial fracture malunion and patient-reported activity limitations: a long-term follow-up. JBJS. 2018;100(8):633–9.CrossRef
16.
go back to reference Chen NC, Jesse B. Jupiter. Management of distal radial fractures. J Bone Joint Surg Am. 2007;89:2051–62.CrossRefPubMed Chen NC, Jesse B. Jupiter. Management of distal radial fractures. J Bone Joint Surg Am. 2007;89:2051–62.CrossRefPubMed
17.
go back to reference Chung KC, et al. Treatment of unstable distal radial fractures with the volar locking plating system. JBJS. 2006;88(12):2687–94.CrossRef Chung KC, et al. Treatment of unstable distal radial fractures with the volar locking plating system. JBJS. 2006;88(12):2687–94.CrossRef
18.
go back to reference Bales JG, Stern PJ. Treatment strategies of distal radius fractures. Hand Clin. 2012;28(2):177–84.CrossRefPubMed Bales JG, Stern PJ. Treatment strategies of distal radius fractures. Hand Clin. 2012;28(2):177–84.CrossRefPubMed
19.
go back to reference Hakimi M, et al. Functional results and complications following locking palmar plating on the distal radius: a retrospective study. J Hand Surg (European Volume). 2010;35(4):283–8.CrossRef Hakimi M, et al. Functional results and complications following locking palmar plating on the distal radius: a retrospective study. J Hand Surg (European Volume). 2010;35(4):283–8.CrossRef
20.
go back to reference Alter TH, et al. Complications of volar plating of distal radius fractures: a systematic review. J Wrist Surg. 2019;8(03):255–62.CrossRefPubMed Alter TH, et al. Complications of volar plating of distal radius fractures: a systematic review. J Wrist Surg. 2019;8(03):255–62.CrossRefPubMed
21.
go back to reference DeGeorge BR, et al. Incidence of complications following volar locking plate fixation of distal radius fractures: an analysis of 647 cases. Plast Reconstr Surg. 2020;145(4):969–76.CrossRefPubMed DeGeorge BR, et al. Incidence of complications following volar locking plate fixation of distal radius fractures: an analysis of 647 cases. Plast Reconstr Surg. 2020;145(4):969–76.CrossRefPubMed
22.
go back to reference Soong M, et al. Volar locking plate implant prominence and flexor tendon rupture. JBJS. 2011;93(4):328–35.CrossRef Soong M, et al. Volar locking plate implant prominence and flexor tendon rupture. JBJS. 2011;93(4):328–35.CrossRef
23.
go back to reference Sochol KM, et al. Optimizing Volar Tilt Restoration and Plate Position in Distal Radius fractures. The Journal of Hand Surgery; 2022. Sochol KM, et al. Optimizing Volar Tilt Restoration and Plate Position in Distal Radius fractures. The Journal of Hand Surgery; 2022.
24.
go back to reference Imatani J, et al. An anatomical study of the watershed line on the Volar, distal aspect of the radius: implications for plate placement and avoidance of tendon ruptures. J Hand Surg. 2012;37(8):1550–4.CrossRef Imatani J, et al. An anatomical study of the watershed line on the Volar, distal aspect of the radius: implications for plate placement and avoidance of tendon ruptures. J Hand Surg. 2012;37(8):1550–4.CrossRef
25.
go back to reference Bergsma M, et al. The watershed line of the distal radius: cadaveric and imaging study of anatomical landmarks. J Wrist Surg. 2020;9(01):044–51.CrossRef Bergsma M, et al. The watershed line of the distal radius: cadaveric and imaging study of anatomical landmarks. J Wrist Surg. 2020;9(01):044–51.CrossRef
26.
go back to reference Orbay JL, Touhami A. Current concepts in Volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Research®. 2006;445:58–67.CrossRef Orbay JL, Touhami A. Current concepts in Volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Research®. 2006;445:58–67.CrossRef
27.
go back to reference Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg. 2008;33(2):164–7.CrossRef Cross AW, Schmidt CC. Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg. 2008;33(2):164–7.CrossRef
28.
go back to reference Selvan DR, et al. The role of fracture reduction and plate position in the aetiology of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand. 2015;10(3):497–502.CrossRefPubMedPubMedCentral Selvan DR, et al. The role of fracture reduction and plate position in the aetiology of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand. 2015;10(3):497–502.CrossRefPubMedPubMedCentral
29.
go back to reference RiKli DA, Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function: a preliminary report of 20 cases. J Bone Joint Surg Br Volume. 1996;78(4):588–92.CrossRef RiKli DA, Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function: a preliminary report of 20 cases. J Bone Joint Surg Br Volume. 1996;78(4):588–92.CrossRef
30.
go back to reference Rikli DA, et al. Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results. J Hand Surg. 2007;32(1):67–75.CrossRef Rikli DA, et al. Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results. J Hand Surg. 2007;32(1):67–75.CrossRef
31.
go back to reference Rhee PC, Medoff RJ, Shin AY. Complex distal radius fractures: an anatomic algorithm for surgical management. JAAOS-Journal Am Acad Orthop Surg. 2017;25(2):77–88.CrossRef Rhee PC, Medoff RJ, Shin AY. Complex distal radius fractures: an anatomic algorithm for surgical management. JAAOS-Journal Am Acad Orthop Surg. 2017;25(2):77–88.CrossRef
32.
go back to reference Jenkins N, Mintowt-Czyz W. Mal-union and dysfunction in Colles’ fracture. J Hand Surg. 1988;13(3):291–3. Jenkins N, Mintowt-Czyz W. Mal-union and dysfunction in Colles’ fracture. J Hand Surg. 1988;13(3):291–3.
33.
Metadata
Title
Volar fixed plating of distal radius fractures: optimizing plate position for enhanced clinical outcomes
Authors
Abdulsamet Emet
Enejd Veizi
Yavuz Karaman
Erkan Akgun
Tolga Tolunay
Ahmet Firat
Publication date
01-12-2024
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2024
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-024-07415-z

Other articles of this Issue 1/2024

BMC Musculoskeletal Disorders 1/2024 Go to the issue