Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2022

Open Access 01-12-2022 | Distal Radius Fracture | Research

Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study

Authors: Yin-Ming Huang, Chun-Yu Chen, Kai-Cheng Lin, Yih-Wen Tarng, Ching-Yi Liao, Wei-Ning Chang

Published in: BMC Musculoskeletal Disorders | Issue 1/2022

Login to get access

Abstract

Introduction

The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants.

Materials and methods

A retrospective study was conducted, all patients who received a Synthes 2.4 mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10 mm of the lunate fossa’s joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded.

Results

Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4 mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (P = 0.016) and grip strengths (P = 0.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (P = 0.006).

Conclusions

Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius’s volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4 mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures.
Literature
1.
go back to reference Mehrzad R, Kim DC. Complication rate comparing variable angle distal locking plate to fixed angle plate fixation of distal radius fractures. Ann Plast Surg. 2016;77(6):623–5.CrossRef Mehrzad R, Kim DC. Complication rate comparing variable angle distal locking plate to fixed angle plate fixation of distal radius fractures. Ann Plast Surg. 2016;77(6):623–5.CrossRef
2.
go back to reference Knežević J, Kodvanj J, Čukelj F, Pamuković F, Pavić A. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture. Injury. 2017;48(Suppl 5):S41–s6.CrossRef Knežević J, Kodvanj J, Čukelj F, Pamuković F, Pavić A. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture. Injury. 2017;48(Suppl 5):S41–s6.CrossRef
3.
go back to reference Heidgerd R, Morgan J, Schentrup D. Evaluation of functional outcomes for adult patients after distal radius fracture treated with volar plate fixation versus nonsurgical care. J Trauma Nurs. 2019;26(1):59–64.CrossRef Heidgerd R, Morgan J, Schentrup D. Evaluation of functional outcomes for adult patients after distal radius fracture treated with volar plate fixation versus nonsurgical care. J Trauma Nurs. 2019;26(1):59–64.CrossRef
4.
go back to reference Hintringer W, Rosenauer R, Pezzei C, Quadlbauer S, Jurkowitsch J, Keuchel T, et al. Biomechanical considerations on a CT-based treatment-oriented classification in radius fractures. Arch Orthop Trauma Surg. 2020;140(5):595–609.CrossRef Hintringer W, Rosenauer R, Pezzei C, Quadlbauer S, Jurkowitsch J, Keuchel T, et al. Biomechanical considerations on a CT-based treatment-oriented classification in radius fractures. Arch Orthop Trauma Surg. 2020;140(5):595–609.CrossRef
5.
go back to reference Leixnering M, Rosenauer R, Pezzei C, Jurkowitsch J, Beer T, Keuchel T, et al. Indications, surgical approach, reduction, and stabilization techniques of distal radius fractures. Arch Orthop Trauma Surg. 2020;140(5):611–21.CrossRef Leixnering M, Rosenauer R, Pezzei C, Jurkowitsch J, Beer T, Keuchel T, et al. Indications, surgical approach, reduction, and stabilization techniques of distal radius fractures. Arch Orthop Trauma Surg. 2020;140(5):611–21.CrossRef
6.
go back to reference Limthongthang R, Bachoura A, Jacoby SM, Osterman AL. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg Am. 2014;39(5):852–60.CrossRef Limthongthang R, Bachoura A, Jacoby SM, Osterman AL. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg Am. 2014;39(5):852–60.CrossRef
7.
go back to reference Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5(2):103–12.CrossRef Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5(2):103–12.CrossRef
8.
go back to reference Quadlbauer S, Pezzei C, Jurkowitsch J, Kolmayr B, Keuchel T, Simon D, et al. Early rehabilitation of distal radius fractures stabilized by volar locking plate: a prospective randomized pilot study. J Wrist Surg. 2017;6(2):102–12.PubMed Quadlbauer S, Pezzei C, Jurkowitsch J, Kolmayr B, Keuchel T, Simon D, et al. Early rehabilitation of distal radius fractures stabilized by volar locking plate: a prospective randomized pilot study. J Wrist Surg. 2017;6(2):102–12.PubMed
9.
go back to reference Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Schättin S, et al. Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year. Arch Orthop Trauma Surg. 2020;140(6):843–52.CrossRef Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Schättin S, et al. Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year. Arch Orthop Trauma Surg. 2020;140(6):843–52.CrossRef
10.
go back to reference Rosenauer R, Pezzei C, Quadlbauer S, Keuchel T, Jurkowitsch J, Hausner T, et al. Complications after operatively treated distal radius fractures. Arch Orthop Trauma Surg. 2020;140(5):665–73.CrossRef Rosenauer R, Pezzei C, Quadlbauer S, Keuchel T, Jurkowitsch J, Hausner T, et al. Complications after operatively treated distal radius fractures. Arch Orthop Trauma Surg. 2020;140(5):665–73.CrossRef
11.
go back to reference Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Schättin S, et al. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Trauma Surg. 2018;138(12):1773–82.CrossRef Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Schättin S, et al. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Trauma Surg. 2018;138(12):1773–82.CrossRef
12.
go back to reference Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011;93(4):328–35.CrossRef Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011;93(4):328–35.CrossRef
13.
go back to reference Cook A, Baldwin P, Fowler JR. Incidence of flexor Pollicis longus complications following volar locking plate fixation of distal radius fractures. Hand (N Y). 2020;15(5):692–7.CrossRef Cook A, Baldwin P, Fowler JR. Incidence of flexor Pollicis longus complications following volar locking plate fixation of distal radius fractures. Hand (N Y). 2020;15(5):692–7.CrossRef
14.
go back to reference Bergsma M, Brown K, Doornberg J, Sierevelt I, Jaarsma R, Jadav B. Distal radius volar plate design and volar prominence to the watershed line in clinical practice: comparison of Soong grading of 2 common plates in 400 patients. J Hand Surg Am. 2019;44(10):853–9.CrossRef Bergsma M, Brown K, Doornberg J, Sierevelt I, Jaarsma R, Jadav B. Distal radius volar plate design and volar prominence to the watershed line in clinical practice: comparison of Soong grading of 2 common plates in 400 patients. J Hand Surg Am. 2019;44(10):853–9.CrossRef
15.
go back to reference Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am. 2013;38(6):1091–6.CrossRef Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am. 2013;38(6):1091–6.CrossRef
16.
go back to reference Vosbikian MM, Ketonis C, Huang R, Ilyas AM. Optimal positioning for volar plate fixation of a distal radius fracture: determining the distal dorsal cortical distance. Orthop Clin North Am. 2016;47(1):235–44.CrossRef Vosbikian MM, Ketonis C, Huang R, Ilyas AM. Optimal positioning for volar plate fixation of a distal radius fracture: determining the distal dorsal cortical distance. Orthop Clin North Am. 2016;47(1):235–44.CrossRef
17.
go back to reference Yamak K, Karahan HG, Karatan B, Kayalı C, Altay T. Evaluation of flexor Pollicis longus tendon rupture after treatment of distal radius fracture with the volar plate. J Wrist Surg. 2020;9(3):219–24.CrossRef Yamak K, Karahan HG, Karatan B, Kayalı C, Altay T. Evaluation of flexor Pollicis longus tendon rupture after treatment of distal radius fracture with the volar plate. J Wrist Surg. 2020;9(3):219–24.CrossRef
18.
go back to reference Spiteri M, Ng W, Matthews J, Power D. Functional outcome of fixation of complex intra-articular distal radius fractures with a variable-angle distal radius volar rim plate. J Hand Microsurg. 2017;9(1):11–6.CrossRef Spiteri M, Ng W, Matthews J, Power D. Functional outcome of fixation of complex intra-articular distal radius fractures with a variable-angle distal radius volar rim plate. J Hand Microsurg. 2017;9(1):11–6.CrossRef
19.
go back to reference Schlickum L, Quadlbauer S, Pezzei C, Stöphasius E, Hausner T, Leixnering M. Three-dimensional kinematics of the flexor pollicis longus tendon in relation to the position of the FPL plate and distal radius width. Arch Orthop Trauma Surg. 2019;139(2):269–79.CrossRef Schlickum L, Quadlbauer S, Pezzei C, Stöphasius E, Hausner T, Leixnering M. Three-dimensional kinematics of the flexor pollicis longus tendon in relation to the position of the FPL plate and distal radius width. Arch Orthop Trauma Surg. 2019;139(2):269–79.CrossRef
20.
go back to reference Palola V, Ponkilainen V, Huttunen T, Launonen A, Mattila VM. Incidence for volar locking plate removal following distal radius fracture surgery. Arch Orthop Trauma Surg. 2021;141(8):1297–302.CrossRef Palola V, Ponkilainen V, Huttunen T, Launonen A, Mattila VM. Incidence for volar locking plate removal following distal radius fracture surgery. Arch Orthop Trauma Surg. 2021;141(8):1297–302.CrossRef
21.
go back to reference Varghese VD, Smitham P, Howell S, Edwards S, Rickman M. POWIFF-Prospective study of wrist internal fixation of fracture: a protocol for a single Centre, superiority, randomised controlled trial to study the efficacy of the VRP (2.0) distal radius plate (Austofix) versus the VA-LCP (Depuy-Synthes) for distal radius fractures. BMC Musculoskelet Disord. 2018;19(1):131.CrossRef Varghese VD, Smitham P, Howell S, Edwards S, Rickman M. POWIFF-Prospective study of wrist internal fixation of fracture: a protocol for a single Centre, superiority, randomised controlled trial to study the efficacy of the VRP (2.0) distal radius plate (Austofix) versus the VA-LCP (Depuy-Synthes) for distal radius fractures. BMC Musculoskelet Disord. 2018;19(1):131.CrossRef
22.
go back to reference Guzzini M, Lanzetti RM, Lupariello D, Morelli F, Princi G, Perugia D, et al. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. Injury. 2017;48(6):1249–52.CrossRef Guzzini M, Lanzetti RM, Lupariello D, Morelli F, Princi G, Perugia D, et al. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. Injury. 2017;48(6):1249–52.CrossRef
23.
go back to reference Landgren M, Abramo A, Geijer M, Kopylov P, Tägil M. Fragment-specific fixation versus volar locking plates in primarily nonreducible or secondarily Redisplaced distal radius fractures: a randomized controlled study. J Hand Surg Am. 2017;42(3):156–65.e1.CrossRef Landgren M, Abramo A, Geijer M, Kopylov P, Tägil M. Fragment-specific fixation versus volar locking plates in primarily nonreducible or secondarily Redisplaced distal radius fractures: a randomized controlled study. J Hand Surg Am. 2017;42(3):156–65.e1.CrossRef
24.
go back to reference Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005;21(3):347–54.CrossRef Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005;21(3):347–54.CrossRef
25.
go back to reference David L. Nelson JO, Randy Bindra. Anatomy of the Volar Distal Radius 2008. David L. Nelson JO, Randy Bindra. Anatomy of the Volar Distal Radius 2008.
26.
go back to reference Bergsma M, Doornberg JN, Hendrickx L, Hayat B, Kerkhoffs G, Jhadav B, et al. Interpretations of the term "watershed line" used as reference for volar plating. J Wrist Surg. 2020;9(3):268–74.CrossRef Bergsma M, Doornberg JN, Hendrickx L, Hayat B, Kerkhoffs G, Jhadav B, et al. Interpretations of the term "watershed line" used as reference for volar plating. J Wrist Surg. 2020;9(3):268–74.CrossRef
27.
go back to reference Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27(1):1–6.CrossRef Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27(1):1–6.CrossRef
28.
go back to reference Casaletto JA, Machin D, Leung R, Brown DJ. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009;34(4):471–4.CrossRef Casaletto JA, Machin D, Leung R, Brown DJ. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009;34(4):471–4.CrossRef
29.
go back to reference White BD, Nydick JA, Karsky D, Williams BD, Hess AV, Stone JD. Incidence and clinical outcomes of tendon rupture following distal radius fracture. J Hand Surg Am. 2012;37(10):2035–40.CrossRef White BD, Nydick JA, Karsky D, Williams BD, Hess AV, Stone JD. Incidence and clinical outcomes of tendon rupture following distal radius fracture. J Hand Surg Am. 2012;37(10):2035–40.CrossRef
32.
go back to reference Buzzell JE, Weikert DR, Watson JT, Lee DH. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am. 2008;33(7):1144–52.CrossRef Buzzell JE, Weikert DR, Watson JT, Lee DH. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am. 2008;33(7):1144–52.CrossRef
33.
go back to reference Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14(4):227–34.CrossRef Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14(4):227–34.CrossRef
Metadata
Title
Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study
Authors
Yin-Ming Huang
Chun-Yu Chen
Kai-Cheng Lin
Yih-Wen Tarng
Ching-Yi Liao
Wei-Ning Chang
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2022
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/s12891-021-04984-1

Other articles of this Issue 1/2022

BMC Musculoskeletal Disorders 1/2022 Go to the issue