Skip to main content
Top
Published in: BMC Cancer 1/2012

Open Access 01-12-2012 | Research article

Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis

Authors: Ying-Hua Yu, Wei Wei, Jian-Lun Liu

Published in: BMC Cancer | Issue 1/2012

Login to get access

Abstract

Background

Fine-needle aspiration biopsy (FNAB) of the breast is a minimally invasive yet maximally diagnostic method. However, the clinical use of FNAB has been questioned. The purpose of our study was to establish the overall value of FNAC in the diagnosis of breast lesions.

Methods

After a review and quality assessment of 46 studies, sensitivity, specificity and other measures of accuracy of FNAB for evaluating breast lesions were pooled using random-effects models. Summary receiver operating characteristic curves were used to summarize overall accuracy. The sensitivity and specificity for the studies data (included unsatisfactory samples) and underestimation rate of unsatisfactory samples were also calculated.

Results

The summary estimates for FNAB in diagnosis of breast carcinoma were as follows (unsatisfactory samples was temporarily exluded): sensitivity, 0.927 (95% confidence interval [CI], 0.921 to 0.933); specificity, 0.948 (95% CI, 0.943 to 0.952); positive likelihood ratio, 25.72 (95% CI, 17.35 to 28.13); negative likelihood ratio, 0.08 (95% CI, 0.06 to 0.11); diagnostic odds ratio, 429.73 (95% CI, 241.75 to 763.87); The pooled sensitivity and specificity for 11 studies, which reported unsatisfactory samples (unsatisfactory samples was considered to be positive in this classification) were 0.920 (95% CI, 0.906 to 0.933) and 0.768 (95% CI, 0.751 to 0.784) respectively. The pooled proportion of unsatisfactory samples that were subsequently upgraded to various grade cancers was 27.5% (95% CI, 0.221 to 0.296).

Conclusions

FNAB is an accurate biopsy for evaluating breast malignancy if rigorous criteria are used. With regard to unsatisfactory samples, futher invasive procedures are required in order to minimize the chance of a missed diagnosis of breast cancer.
Appendix
Available only for authorised users
Literature
1.
go back to reference Gupta RK, Naran S, Buchanan A, Fauck R, Simpson J: Fine-needle aspiration cytology of breast: its impact on surgical practice with an emphasis on the diagnosis of breast abnormalities in young women. Diagn Cytopathol. 1988, 4: 206-209. 10.1002/dc.2840040306.CrossRefPubMed Gupta RK, Naran S, Buchanan A, Fauck R, Simpson J: Fine-needle aspiration cytology of breast: its impact on surgical practice with an emphasis on the diagnosis of breast abnormalities in young women. Diagn Cytopathol. 1988, 4: 206-209. 10.1002/dc.2840040306.CrossRefPubMed
2.
go back to reference Dowlatshahi K, Jokich PM, Schmidt R, Bibbo M, Dawson PJ: Cytologic diagnosis of occult breast lesions using stereotactic needle aspiration: a preliminary report. Arch Surg. 1987, 122: 1343-1346. 10.1001/archsurg.1987.01400230131023.CrossRefPubMed Dowlatshahi K, Jokich PM, Schmidt R, Bibbo M, Dawson PJ: Cytologic diagnosis of occult breast lesions using stereotactic needle aspiration: a preliminary report. Arch Surg. 1987, 122: 1343-1346. 10.1001/archsurg.1987.01400230131023.CrossRefPubMed
3.
go back to reference Evans WP, Cade SH: Needle localization and fine-needle aspiration biopsy of nonpalpable breast lesions with use of standard and stereotactic equipment. Radiology. 1989, 173: 53-56.CrossRefPubMed Evans WP, Cade SH: Needle localization and fine-needle aspiration biopsy of nonpalpable breast lesions with use of standard and stereotactic equipment. Radiology. 1989, 173: 53-56.CrossRefPubMed
4.
go back to reference Sterrett G, Oliver D, Trayne J, Ingram D, Sherner H: Stereotactic fine-needle aspiration biopsy (SFNB) of breast: preliminary results in Perth with the TRC Mammotest machine--cytological aspects. Pathology. 1991, 23: 302-310. 10.3109/00313029109063593.CrossRefPubMed Sterrett G, Oliver D, Trayne J, Ingram D, Sherner H: Stereotactic fine-needle aspiration biopsy (SFNB) of breast: preliminary results in Perth with the TRC Mammotest machine--cytological aspects. Pathology. 1991, 23: 302-310. 10.3109/00313029109063593.CrossRefPubMed
5.
go back to reference Azavedo E, Svane G, Auer G: Stereotactic fine-needle biopsy in 2594 mammographically detected nonpalpable lesions. Lancet. 1989, 1: 1033-1035.CrossRefPubMed Azavedo E, Svane G, Auer G: Stereotactic fine-needle biopsy in 2594 mammographically detected nonpalpable lesions. Lancet. 1989, 1: 1033-1035.CrossRefPubMed
6.
go back to reference Evans WP, Cade SH: Needle localization and fine-needle aspiration biopsy of nonpalpable breast lesions with use of standard and stereotactic equipment. Radiology. 1989, 173: 53-56.CrossRefPubMed Evans WP, Cade SH: Needle localization and fine-needle aspiration biopsy of nonpalpable breast lesions with use of standard and stereotactic equipment. Radiology. 1989, 173: 53-56.CrossRefPubMed
7.
go back to reference Jay H, Monica M, Marce L, Samuel H: Disease of the Breast. Philadelphia: Lippincott-Raven. 1996, Ch. 5: Jay H, Monica M, Marce L, Samuel H: Disease of the Breast. Philadelphia: Lippincott-Raven. 1996, Ch. 5:
8.
go back to reference Jackson VP, Reynolds HE: Stereotactic needle-core biopsy and fine-needle aspiration cytologic evaluation of nonpalpable breast lesions. Radiology. 1991, 181: 633-634.CrossRefPubMed Jackson VP, Reynolds HE: Stereotactic needle-core biopsy and fine-needle aspiration cytologic evaluation of nonpalpable breast lesions. Radiology. 1991, 181: 633-634.CrossRefPubMed
9.
go back to reference Whiting PF, Weswood ME, Rutjes AWS, Reitsma JB, Bossuyt PNM, Kleijnen J: Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies. BMC Medical Research Methodology. 2006, 6: 9-10.1186/1471-2288-6-9.CrossRefPubMedPubMedCentral Whiting PF, Weswood ME, Rutjes AWS, Reitsma JB, Bossuyt PNM, Kleijnen J: Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies. BMC Medical Research Methodology. 2006, 6: 9-10.1186/1471-2288-6-9.CrossRefPubMedPubMedCentral
10.
go back to reference Deville WL, Buntinx F, Bouter LM, Montori VM, Vet HCW, Windt DAWM, Bezemer PD: Conducting systematic reviews of diagnostic studies: didactic guidelines. BMC Med Res Methodol. 2002, 2: 9-10.1186/1471-2288-2-9.CrossRefPubMedPubMedCentral Deville WL, Buntinx F, Bouter LM, Montori VM, Vet HCW, Windt DAWM, Bezemer PD: Conducting systematic reviews of diagnostic studies: didactic guidelines. BMC Med Res Methodol. 2002, 2: 9-10.1186/1471-2288-2-9.CrossRefPubMedPubMedCentral
11.
go back to reference Kanchanabat B, Kanchanapitak P, Thanapongsathorn W, Manomaiphiboon A: Fine-needle aspiration cytology for diagnosis and management of palpable breast mass. Aust NZ J Surg. 2000, 70: 791-794. 10.1046/j.1440-1622.2000.01975.x.CrossRef Kanchanabat B, Kanchanapitak P, Thanapongsathorn W, Manomaiphiboon A: Fine-needle aspiration cytology for diagnosis and management of palpable breast mass. Aust NZ J Surg. 2000, 70: 791-794. 10.1046/j.1440-1622.2000.01975.x.CrossRef
12.
go back to reference Pisano ED, Fajardo LL, Caudry DJ, Sneige N, Frable WJ, Berg WA, Tocino I, Schnitt SJ, Connolly JL, Gatsonis CA, McNeil BJ: Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V. Radiology. 2001, 219: 785-792.CrossRefPubMed Pisano ED, Fajardo LL, Caudry DJ, Sneige N, Frable WJ, Berg WA, Tocino I, Schnitt SJ, Connolly JL, Gatsonis CA, McNeil BJ: Fine-Needle Aspiration Biopsy of Nonpalpable Breast Lesions in a Multicenter Clinical Trial: Results from the Radiologic Diagnostic Oncology Group V. Radiology. 2001, 219: 785-792.CrossRefPubMed
13.
go back to reference Moses LE, Shapiro D, Littenberg B: Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med. 1993, 12: 1293-1316.CrossRefPubMed Moses LE, Shapiro D, Littenberg B: Combining independent studies of a diagnostic test into a summary ROC curve: data-analytic approaches and some additional considerations. Stat Med. 1993, 12: 1293-1316.CrossRefPubMed
14.
go back to reference Lau J, Ioannidis JP, Balk EM, Milch C, Terrin N, Chew PW, Salem D: Diagnosing acute cardiac ischemia in the emergency department: a systematic review of the accuracy and clinical effect of current technologies. Ann Emerg Med. 2001, 37: 453-460. 10.1067/mem.2001.114903.CrossRefPubMed Lau J, Ioannidis JP, Balk EM, Milch C, Terrin N, Chew PW, Salem D: Diagnosing acute cardiac ischemia in the emergency department: a systematic review of the accuracy and clinical effect of current technologies. Ann Emerg Med. 2001, 37: 453-460. 10.1067/mem.2001.114903.CrossRefPubMed
15.
go back to reference Irwig L, Tosteson AN, Gatsonis C, Lau J, Colditz G, Chalmers TC, Mosteller F: Guidelines for meta-analyses evaluating diagnostic tests. Ann Intern Med. 1994, 120: 667-676.CrossRefPubMed Irwig L, Tosteson AN, Gatsonis C, Lau J, Colditz G, Chalmers TC, Mosteller F: Guidelines for meta-analyses evaluating diagnostic tests. Ann Intern Med. 1994, 120: 667-676.CrossRefPubMed
16.
go back to reference Suzuki S, Moro-oka T, Choudhry NK: The conditional relative odds ratio provided less biased results for comparing diagnostic test accuracy in meta-analyses. J Clin Epidemiol. 2004, 57: 461-469. 10.1016/j.jclinepi.2003.09.017.CrossRefPubMed Suzuki S, Moro-oka T, Choudhry NK: The conditional relative odds ratio provided less biased results for comparing diagnostic test accuracy in meta-analyses. J Clin Epidemiol. 2004, 57: 461-469. 10.1016/j.jclinepi.2003.09.017.CrossRefPubMed
17.
go back to reference Westwood ME, Whiting PF, Kleijnen J: How does study quality affect the results of a diagnostic meta-analysis?. BMC Med Res Methodol. 2005, 8: 20-CrossRef Westwood ME, Whiting PF, Kleijnen J: How does study quality affect the results of a diagnostic meta-analysis?. BMC Med Res Methodol. 2005, 8: 20-CrossRef
18.
go back to reference Egger M, Davey Smith G, Schneider M, Minder C: Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997, 315: 629-634. 10.1136/bmj.315.7109.629.CrossRefPubMedPubMedCentral Egger M, Davey Smith G, Schneider M, Minder C: Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997, 315: 629-634. 10.1136/bmj.315.7109.629.CrossRefPubMedPubMedCentral
19.
go back to reference Mezzelani A, Alasio L, Bartoli C, Bonoral MG, Pierotti MA, Rilke F, Pilotti S: c-erbB2/neu gene and chromosome 17 analysis in breast cancer by FISH on archival cytological fine-needle aspirates. British Journal of Cancer. 1999, 80: 519-525. 10.1038/sj.bjc.6690387.CrossRefPubMedPubMedCentral Mezzelani A, Alasio L, Bartoli C, Bonoral MG, Pierotti MA, Rilke F, Pilotti S: c-erbB2/neu gene and chromosome 17 analysis in breast cancer by FISH on archival cytological fine-needle aspirates. British Journal of Cancer. 1999, 80: 519-525. 10.1038/sj.bjc.6690387.CrossRefPubMedPubMedCentral
20.
go back to reference Bofin AM, Ytterhus B, Hagmar BM: TOP2A and HER-2 gene amplification in fine needle aspirates from breast carcinomas. Cytopathology. 2003, 14: 314-319. 10.1046/j.0956-5507.2003.00088.x.CrossRefPubMed Bofin AM, Ytterhus B, Hagmar BM: TOP2A and HER-2 gene amplification in fine needle aspirates from breast carcinomas. Cytopathology. 2003, 14: 314-319. 10.1046/j.0956-5507.2003.00088.x.CrossRefPubMed
21.
go back to reference Somani A, Hwang JSG, Chaiwun B, Tse GMK, Liu PCWUI, Tan PH: Fine needle aspiration cytology in young women with breast cancer: diagnostic difficulties. Pathology. 2008, 40 (4): 359-364. 10.1080/00313020802035881.CrossRefPubMed Somani A, Hwang JSG, Chaiwun B, Tse GMK, Liu PCWUI, Tan PH: Fine needle aspiration cytology in young women with breast cancer: diagnostic difficulties. Pathology. 2008, 40 (4): 359-364. 10.1080/00313020802035881.CrossRefPubMed
22.
go back to reference Gazic B, Pizem J, Bracko M, Cufer T, Borstnar S, Pohar-Marinsek Z, Us-Krasovec M: S-phase fraction determined on fine needle aspirates is an independent prognostic factor in breast cancer - a multivariate study of 770 patients. Cytopathology. 2008, 19: 294-302. 10.1111/j.1365-2303.2007.00528.x.CrossRefPubMed Gazic B, Pizem J, Bracko M, Cufer T, Borstnar S, Pohar-Marinsek Z, Us-Krasovec M: S-phase fraction determined on fine needle aspirates is an independent prognostic factor in breast cancer - a multivariate study of 770 patients. Cytopathology. 2008, 19: 294-302. 10.1111/j.1365-2303.2007.00528.x.CrossRefPubMed
23.
go back to reference Kelten C, Akbulut M, Zekioglu O, Kapkac M, Erhan Y, Ozdemir N: Signet ring cells in fine needle aspiration cytology of breast carcinomas: review of the cytological findings in ten cases identified by histology. Cytopathology. 2009, 20: 321-327. 10.1111/j.1365-2303.2008.00630.x.CrossRefPubMed Kelten C, Akbulut M, Zekioglu O, Kapkac M, Erhan Y, Ozdemir N: Signet ring cells in fine needle aspiration cytology of breast carcinomas: review of the cytological findings in ten cases identified by histology. Cytopathology. 2009, 20: 321-327. 10.1111/j.1365-2303.2008.00630.x.CrossRefPubMed
24.
go back to reference Zhang BL, Chang LX: Comparison Between Serum Cancer Antigen 15. 3 Diagnosing Mammary Cancer and Fine Needle Aspination Cytology Diagnosing Mammary Cancer. J PMT. 2006, 13: 1235-1236. Zhang BL, Chang LX: Comparison Between Serum Cancer Antigen 15. 3 Diagnosing Mammary Cancer and Fine Needle Aspination Cytology Diagnosing Mammary Cancer. J PMT. 2006, 13: 1235-1236.
25.
go back to reference Sun YF, Xu JH, Ye K, Xu ST: The value of preoperative diagnosis based on fine - needle aspiration cytology for breast cancer. Hebei Medicine. 2010, 16 (3): 300-302. Sun YF, Xu JH, Ye K, Xu ST: The value of preoperative diagnosis based on fine - needle aspiration cytology for breast cancer. Hebei Medicine. 2010, 16 (3): 300-302.
26.
go back to reference Jin WH, Li RY, Cui CA, Piao DM, Shen ZS: Diagnostic value of fine needle aspiration biopsy telomerase activity in breast neoplasm. CHIN J CANCER PREV TREAT. 2004, 11 (5): 485-487. Jin WH, Li RY, Cui CA, Piao DM, Shen ZS: Diagnostic value of fine needle aspiration biopsy telomerase activity in breast neoplasm. CHIN J CANCER PREV TREAT. 2004, 11 (5): 485-487.
27.
go back to reference Sapino A, Cassoni P, Zanon E, Fraire F, Croce S, Coluccia C, Donadio M, Bussolati G: Ultrasonographically-guided fine-needle aspiration of axillary lymph nodes: role in breast cancer management. British Journal of Cancer. 2003, 88: 702-706. 10.1038/sj.bjc.6600744.CrossRefPubMedPubMedCentral Sapino A, Cassoni P, Zanon E, Fraire F, Croce S, Coluccia C, Donadio M, Bussolati G: Ultrasonographically-guided fine-needle aspiration of axillary lymph nodes: role in breast cancer management. British Journal of Cancer. 2003, 88: 702-706. 10.1038/sj.bjc.6600744.CrossRefPubMedPubMedCentral
28.
go back to reference Jain A, Haisfield-Wolfe ME, Lange J, Ahuja N, Khouri N, Tsangaris T, Zhang Z, Balch C, Jacobs LK: The Role of Ultrasound-Guided Fine-Needle Aspiration of Axillary Nodes in the Staging of Breast Cancer. Annals of Surgical Oncology. 2002, 15 (2): 462-471.CrossRef Jain A, Haisfield-Wolfe ME, Lange J, Ahuja N, Khouri N, Tsangaris T, Zhang Z, Balch C, Jacobs LK: The Role of Ultrasound-Guided Fine-Needle Aspiration of Axillary Nodes in the Staging of Breast Cancer. Annals of Surgical Oncology. 2002, 15 (2): 462-471.CrossRef
29.
go back to reference Kooistra B, Wauters C, Strobbe L: Indeterminate Breast Fine-Needle Aspiration: Repeat Aspiration or Core Needle Biopsy?. Ann Surg Oncol. 2009, 16: 281-284. 10.1245/s10434-008-0246-y.CrossRefPubMed Kooistra B, Wauters C, Strobbe L: Indeterminate Breast Fine-Needle Aspiration: Repeat Aspiration or Core Needle Biopsy?. Ann Surg Oncol. 2009, 16: 281-284. 10.1245/s10434-008-0246-y.CrossRefPubMed
30.
go back to reference Jeronimo G, Monteiro P, Henrique R, Dinis-Ribeiro M, Costa I, Costa VL, Filipe L, Carvalho A, Hoque MO, Pais I, Leal C, Teixeira MR, Sidransky D: Quantitative hypermethylation of a small panel of genes augments the diagnostic accuracy in fine-needle aspirate washings of breast lesions. Breast Cancer Res Treat. 2008, 109: 27-34. 10.1007/s10549-007-9620-x.CrossRefPubMed Jeronimo G, Monteiro P, Henrique R, Dinis-Ribeiro M, Costa I, Costa VL, Filipe L, Carvalho A, Hoque MO, Pais I, Leal C, Teixeira MR, Sidransky D: Quantitative hypermethylation of a small panel of genes augments the diagnostic accuracy in fine-needle aspirate washings of breast lesions. Breast Cancer Res Treat. 2008, 109: 27-34. 10.1007/s10549-007-9620-x.CrossRefPubMed
31.
go back to reference Sauer T, Young K, Thoresen SS: Fine needle aspiration cytology in the work-up of mammographic and ultrasonographic finding in breast cancer screening: an attempt at differentiating in situ and invasive carcinoma. Cytopathology. 2002, 13: 101-110. 10.1046/j.1365-2303.2002.00372.x.CrossRefPubMed Sauer T, Young K, Thoresen SS: Fine needle aspiration cytology in the work-up of mammographic and ultrasonographic finding in breast cancer screening: an attempt at differentiating in situ and invasive carcinoma. Cytopathology. 2002, 13: 101-110. 10.1046/j.1365-2303.2002.00372.x.CrossRefPubMed
32.
go back to reference Sauer T, Myrvold K, L¢mo J, Anderssen KY, Skaane P: Fine-needle aspiration cytology in nonpalpable mammographic abnormalities in breast cancer screening: results from the breast cancer screening programme in Oslo 1996-2001. The Breast. 2003, 12: 314-319. 10.1016/S0960-9776(03)00102-4.CrossRefPubMed Sauer T, Myrvold K, L¢mo J, Anderssen KY, Skaane P: Fine-needle aspiration cytology in nonpalpable mammographic abnormalities in breast cancer screening: results from the breast cancer screening programme in Oslo 1996-2001. The Breast. 2003, 12: 314-319. 10.1016/S0960-9776(03)00102-4.CrossRefPubMed
33.
go back to reference Walker SR: A randomized controlled trial comparing a 21 G needle with a 23 G needle for fine needle aspiration of breast lumps. J R Coll Surg Edink. 1998, 43: 322-332. Walker SR: A randomized controlled trial comparing a 21 G needle with a 23 G needle for fine needle aspiration of breast lumps. J R Coll Surg Edink. 1998, 43: 322-332.
34.
go back to reference Lumachi F, Marzola MC, Zucchetta P, Polistina F, Cagnato P, Favia G, Bui F: Breast Cancer Detection With 99m-Tc-Sestamibi Scintigraphy, Mammography, and Fine-Needle Aspiration Cytology: Comparative Study in 64 Surgically Treated Patients. Annals of Surgical Oncology. 1999, 6 (6): 568-571. 10.1007/s10434-999-0568-4.CrossRefPubMed Lumachi F, Marzola MC, Zucchetta P, Polistina F, Cagnato P, Favia G, Bui F: Breast Cancer Detection With 99m-Tc-Sestamibi Scintigraphy, Mammography, and Fine-Needle Aspiration Cytology: Comparative Study in 64 Surgically Treated Patients. Annals of Surgical Oncology. 1999, 6 (6): 568-571. 10.1007/s10434-999-0568-4.CrossRefPubMed
35.
go back to reference Farshid G, Downey P, Gill PG, Pieterse S: Assessment of 1183 screen-detected, category 3B, circumscribed masses by cytology and core biopsy with long-term follow up data. British Journal of Cancer. 2008, 98: 1182-1190. 10.1038/sj.bjc.6604296.CrossRefPubMedPubMedCentral Farshid G, Downey P, Gill PG, Pieterse S: Assessment of 1183 screen-detected, category 3B, circumscribed masses by cytology and core biopsy with long-term follow up data. British Journal of Cancer. 2008, 98: 1182-1190. 10.1038/sj.bjc.6604296.CrossRefPubMedPubMedCentral
36.
go back to reference Dennison G, Anand R, Makar SH, Pain JA: A Prospective Study of the Use of Fine-Needle Aspiration Cytology and Core Biopsy in the Diagnosis of Breast Cancer. The Breast Journal. 2003, 9 (4): 491-493.CrossRefPubMed Dennison G, Anand R, Makar SH, Pain JA: A Prospective Study of the Use of Fine-Needle Aspiration Cytology and Core Biopsy in the Diagnosis of Breast Cancer. The Breast Journal. 2003, 9 (4): 491-493.CrossRefPubMed
37.
go back to reference Gent HJ, Sprenger E, Doulatshahl K: Stereotaxic needle localization and cytological diagnosis of occult breast lesions. Ann Surg. 1986, 204 (5): 580-584. 10.1097/00000658-198611000-00012.CrossRefPubMedPubMedCentral Gent HJ, Sprenger E, Doulatshahl K: Stereotaxic needle localization and cytological diagnosis of occult breast lesions. Ann Surg. 1986, 204 (5): 580-584. 10.1097/00000658-198611000-00012.CrossRefPubMedPubMedCentral
38.
go back to reference Wanebo HJ, Feldman PS, Wilhelm MC, Covell JL, Binns RL: Fine needle aspiration cytology in lieu of oper biopsy in management of primary breast cancer. Ann Surg. 1984, 199 (5): 570-579.CrossRef Wanebo HJ, Feldman PS, Wilhelm MC, Covell JL, Binns RL: Fine needle aspiration cytology in lieu of oper biopsy in management of primary breast cancer. Ann Surg. 1984, 199 (5): 570-579.CrossRef
39.
go back to reference Apesteguia L, Pina L, Inchusta M, Mellado M, Franque T, Miguel DC, Lopez-Cousillas A, Reparaz B: Nonpalpable, well-defined, probably benign breast nodule: management by fine-needle aspiration biopsy and long-interval follow-up mammography. Eur. Radiol. 1997, 7: 1235-1239. 10.1007/s003300050282.CrossRefPubMed Apesteguia L, Pina L, Inchusta M, Mellado M, Franque T, Miguel DC, Lopez-Cousillas A, Reparaz B: Nonpalpable, well-defined, probably benign breast nodule: management by fine-needle aspiration biopsy and long-interval follow-up mammography. Eur. Radiol. 1997, 7: 1235-1239. 10.1007/s003300050282.CrossRefPubMed
40.
go back to reference Manheimer LH, Rywlin AM: Fine needle aspiration cytology. Southern medical journal. 1977, 70 (8): 293-295.CrossRef Manheimer LH, Rywlin AM: Fine needle aspiration cytology. Southern medical journal. 1977, 70 (8): 293-295.CrossRef
41.
go back to reference Jan M, Mattoo JA, Salroo NA, Ahangar S: Triple assessment in the diagnosis of breast cancer in Kashmir. Indian J Surg. 2010, 72: 97-103. 10.1007/s12262-010-0030-7.CrossRefPubMedPubMedCentral Jan M, Mattoo JA, Salroo NA, Ahangar S: Triple assessment in the diagnosis of breast cancer in Kashmir. Indian J Surg. 2010, 72: 97-103. 10.1007/s12262-010-0030-7.CrossRefPubMedPubMedCentral
42.
go back to reference Drew PJ, Turnbull LW, Chatterjee S, Read J, Carleton PJ, Fox JN, Monson JRT, Kerin MJ: Prospective Comparison of Standard Triple Assessment and Dynamic Magnetic Resonance Imaging of the Breast for the Evaluation of Symptomatic Breast Lesions. Annals of surgery. 1999, 230 (5): 680-685. 10.1097/00000658-199911000-00010.CrossRefPubMedPubMedCentral Drew PJ, Turnbull LW, Chatterjee S, Read J, Carleton PJ, Fox JN, Monson JRT, Kerin MJ: Prospective Comparison of Standard Triple Assessment and Dynamic Magnetic Resonance Imaging of the Breast for the Evaluation of Symptomatic Breast Lesions. Annals of surgery. 1999, 230 (5): 680-685. 10.1097/00000658-199911000-00010.CrossRefPubMedPubMedCentral
43.
go back to reference Masood S, Frykberg ER, Mclellan GL, Bullard JB: Application of estrogen receptor immunocytochemical assay to aspirates from mammographically guided fine needle biopsy of nonpalpable breast lesions. Southern medical journal. 1991, 84 (7): 857-861. 10.1097/00007611-199107000-00009.CrossRefPubMed Masood S, Frykberg ER, Mclellan GL, Bullard JB: Application of estrogen receptor immunocytochemical assay to aspirates from mammographically guided fine needle biopsy of nonpalpable breast lesions. Southern medical journal. 1991, 84 (7): 857-861. 10.1097/00007611-199107000-00009.CrossRefPubMed
44.
go back to reference Ishikawa T, Hamaguchi Y, Tanabe M, Momiyama N, Chishima T, Nakatani Y, Nozawa A, Sasaki T, Kitamura H, Shimada H: False-Positive and False-Negative Cases of Fine-Needle Aspiration Cytology for Palpable Breast Lesions. Breast Cancer. 2007, 14 (4): 388-392. 10.2325/jbcs.14.388.CrossRefPubMed Ishikawa T, Hamaguchi Y, Tanabe M, Momiyama N, Chishima T, Nakatani Y, Nozawa A, Sasaki T, Kitamura H, Shimada H: False-Positive and False-Negative Cases of Fine-Needle Aspiration Cytology for Palpable Breast Lesions. Breast Cancer. 2007, 14 (4): 388-392. 10.2325/jbcs.14.388.CrossRefPubMed
45.
go back to reference Crotch-Harvey MA, Loughran CF: Combined stereotactic wide-core needle biopsy and fine-needle aspiration cytology in the assessment of impalpable mammographic abnormalities detected in a breast-screening programme. The Breast. 1996, 5: 48-49. 10.1016/S0960-9776(96)90049-1.CrossRef Crotch-Harvey MA, Loughran CF: Combined stereotactic wide-core needle biopsy and fine-needle aspiration cytology in the assessment of impalpable mammographic abnormalities detected in a breast-screening programme. The Breast. 1996, 5: 48-49. 10.1016/S0960-9776(96)90049-1.CrossRef
46.
go back to reference Leifland K, Lagersted U, Svane G: Comparison of stereotactic fine needle aspiration cytology and core needle biopsy in 522 non-palpable breast lesions. Acta Radiologica. 2003, 44: 387-391.CrossRefPubMed Leifland K, Lagersted U, Svane G: Comparison of stereotactic fine needle aspiration cytology and core needle biopsy in 522 non-palpable breast lesions. Acta Radiologica. 2003, 44: 387-391.CrossRefPubMed
47.
go back to reference Okamoto H, Ogawara T, Inoue S, Kobayashi K, Sekikawa T, Matsumoto Y: Clinical Management of Nonpalpable or Small Breast Masses by Fine-Needle Aspiration Biopsy (FNAB) Under Ultrasound Guidance. Journal of Surgical Oncology. 1998, 67: 246-250. 10.1002/(SICI)1096-9098(199804)67:4<246::AID-JSO7>3.0.CO;2-8.CrossRefPubMed Okamoto H, Ogawara T, Inoue S, Kobayashi K, Sekikawa T, Matsumoto Y: Clinical Management of Nonpalpable or Small Breast Masses by Fine-Needle Aspiration Biopsy (FNAB) Under Ultrasound Guidance. Journal of Surgical Oncology. 1998, 67: 246-250. 10.1002/(SICI)1096-9098(199804)67:4<246::AID-JSO7>3.0.CO;2-8.CrossRefPubMed
48.
go back to reference Rubin M, Horiuchi K, Joy N, Haun W, Read R, Ratzer E, Fenoglio M, Colorado D: Use of Fine Needle Aspiration for Solid Breast Lesions Is Accurate and Cost-Effective. The American journal of surgery. 1997, 7: 694-698.CrossRef Rubin M, Horiuchi K, Joy N, Haun W, Read R, Ratzer E, Fenoglio M, Colorado D: Use of Fine Needle Aspiration for Solid Breast Lesions Is Accurate and Cost-Effective. The American journal of surgery. 1997, 7: 694-698.CrossRef
49.
go back to reference Li JG: The value of CA15-3 and Fine-needle aspiration about the diagnosis of breast cancer. J of Radioimmunology. 2008, 21 (2): 190-191. Li JG: The value of CA15-3 and Fine-needle aspiration about the diagnosis of breast cancer. J of Radioimmunology. 2008, 21 (2): 190-191.
50.
go back to reference Wang DJ: The value of the Fine-needle aspiration about the diagnosis and treatment of breast neoplasms (D). Fu Jian: Fujian Medical University. 2010 Wang DJ: The value of the Fine-needle aspiration about the diagnosis and treatment of breast neoplasms (D). Fu Jian: Fujian Medical University. 2010
51.
go back to reference Yang HY, Bao L: Value of fine needle aspiration cytology in the diagnosis of breast cancer. Maternal and Child Health in China. 2000, 25: 1995-1996. Yang HY, Bao L: Value of fine needle aspiration cytology in the diagnosis of breast cancer. Maternal and Child Health in China. 2000, 25: 1995-1996.
52.
go back to reference Liu CJ: Cytological diagnosis of breast cancer by fine needle aspiration:experience of 688 cases. Medicine Theory and Practice. 2000, 13: 436-437. Liu CJ: Cytological diagnosis of breast cancer by fine needle aspiration:experience of 688 cases. Medicine Theory and Practice. 2000, 13: 436-437.
53.
go back to reference Zhao QW, Zhan Y, Yu XM, Guo QH: Value of fine needle a spiration biopsy in cytological diagnosis of breaet cancer. Journal of Xinxiang Medical College. 2009, 26 (5): 481-483. Zhao QW, Zhan Y, Yu XM, Guo QH: Value of fine needle a spiration biopsy in cytological diagnosis of breaet cancer. Journal of Xinxiang Medical College. 2009, 26 (5): 481-483.
54.
go back to reference Zhan PY, Ye EBLT: The Cytology Result Analysis of Thin needle Puncture to 126 Cases Mammry Tumour. JPMT. 2007, 14: 435-436. Zhan PY, Ye EBLT: The Cytology Result Analysis of Thin needle Puncture to 126 Cases Mammry Tumour. JPMT. 2007, 14: 435-436.
55.
go back to reference Gao L, Zhang MH, Zhu MH: Histopathology and fine needle aspiratory cytology of 281 cases of breast mass: a comparison analysis. Acad J Sec Mil Med Univ. 2005, 26: 825-826. Gao L, Zhang MH, Zhu MH: Histopathology and fine needle aspiratory cytology of 281 cases of breast mass: a comparison analysis. Acad J Sec Mil Med Univ. 2005, 26: 825-826.
56.
go back to reference Lu B, Chen BX, Sun FX, Yan YJ, Wang LD: The value of ultrasound-guided fine needle aspiratory with continuous negative pressure in diagnosis of breast disease. Chin J of Clinical Rational Drug Use. 2010, 3: 106-107. Lu B, Chen BX, Sun FX, Yan YJ, Wang LD: The value of ultrasound-guided fine needle aspiratory with continuous negative pressure in diagnosis of breast disease. Chin J of Clinical Rational Drug Use. 2010, 3: 106-107.
57.
go back to reference Liu QH, Hong J, Liu Y, Xu M: Application of Fine needle Aspiration Biopsy Under Ultrasonic Guidance in the Diagnosis of Breast Lesions. Journal of Mathematical Medicine. 2010, 23: 216-217. Liu QH, Hong J, Liu Y, Xu M: Application of Fine needle Aspiration Biopsy Under Ultrasonic Guidance in the Diagnosis of Breast Lesions. Journal of Mathematical Medicine. 2010, 23: 216-217.
58.
go back to reference Zhang YA, Li JS, Ji ZL, Tang WH: Combined use of fine needle aspiration cytology and full field digital mammography in preoperative assessment of breast masses. Chinese-German Journal of Clinical Oncology. 2008, 7: 473-476. 10.1007/s10330-008-0063-6.CrossRef Zhang YA, Li JS, Ji ZL, Tang WH: Combined use of fine needle aspiration cytology and full field digital mammography in preoperative assessment of breast masses. Chinese-German Journal of Clinical Oncology. 2008, 7: 473-476. 10.1007/s10330-008-0063-6.CrossRef
59.
go back to reference Zhang YN, You CZ, Li JS, Chen WD, Fan X, Hu HL, Zheng KE, Liu WH, Hao YY, He J, Tang WH: The diagnostic value of digital mammography, ultrasonography and fine needle aspiration biopsy in breast cancer. ModernMedical Journal. 2006, 34 (6): 392-394. Zhang YN, You CZ, Li JS, Chen WD, Fan X, Hu HL, Zheng KE, Liu WH, Hao YY, He J, Tang WH: The diagnostic value of digital mammography, ultrasonography and fine needle aspiration biopsy in breast cancer. ModernMedical Journal. 2006, 34 (6): 392-394.
60.
go back to reference Tang SS, Qian WZ, Yao ZX, Nan WK, Tu TX, Lu YS, Zhang WY: Cytological diagnosis of breast disease by fine needle aspiration: experience of 464 cases. Si Chuan Medical Journal. 1987, 8 (5): 278-279. Tang SS, Qian WZ, Yao ZX, Nan WK, Tu TX, Lu YS, Zhang WY: Cytological diagnosis of breast disease by fine needle aspiration: experience of 464 cases. Si Chuan Medical Journal. 1987, 8 (5): 278-279.
61.
go back to reference Wang H, Zhou Q, Zhang L, Pan YC, Pan WS: The value of stereotactic-guided fine needle aspiratory in diagnosis of breast disease. Diagnostic Pathology Journal. 1995, 2 (5): 29-31. Wang H, Zhou Q, Zhang L, Pan YC, Pan WS: The value of stereotactic-guided fine needle aspiratory in diagnosis of breast disease. Diagnostic Pathology Journal. 1995, 2 (5): 29-31.
62.
go back to reference Ma JZ, Gan J, Wu D, Li N, Zhang JJ: Value of Fine needle aspiration in the diagnosis of breast mass. Journal of Qi qi ha er Medical College. 2010, 13: 1903- Ma JZ, Gan J, Wu D, Li N, Zhang JJ: Value of Fine needle aspiration in the diagnosis of breast mass. Journal of Qi qi ha er Medical College. 2010, 13: 1903-
63.
go back to reference Wang Y, Li J: Results analysis of 610 mammary gland tumors by using thin needle puncture cytolog. Modern medical and health Journal. 2010, 26 (7): 1004-1005. Wang Y, Li J: Results analysis of 610 mammary gland tumors by using thin needle puncture cytolog. Modern medical and health Journal. 2010, 26 (7): 1004-1005.
64.
go back to reference Wang HF: Cytologic examination of breast mass with fine needle aspiration technique in 1024 cases. Oncology Supplement. 1981, 139-140. Wang HF: Cytologic examination of breast mass with fine needle aspiration technique in 1024 cases. Oncology Supplement. 1981, 139-140.
65.
go back to reference Wei LW, Han GX, Liu JB, Wei LM, Dong SY, Wang QB: The clinical value of fine needle aspiration cytologic diagnosis for breast masses. Journal of Tai Shan Medical College. 2007, 28: 41-43. Wei LW, Han GX, Liu JB, Wei LM, Dong SY, Wang QB: The clinical value of fine needle aspiration cytologic diagnosis for breast masses. Journal of Tai Shan Medical College. 2007, 28: 41-43.
66.
go back to reference Tao GH, Liu ZF, Liu HM, Liu YQ, He AL, Guan TY: A Study of Fine Needle Aspiration Cytologic Diagnosis for Breast Masses. Henan Journal of oncology. 2004, 17: 350-351. Tao GH, Liu ZF, Liu HM, Liu YQ, He AL, Guan TY: A Study of Fine Needle Aspiration Cytologic Diagnosis for Breast Masses. Henan Journal of oncology. 2004, 17: 350-351.
67.
go back to reference Wang PL, Hui JJ: A Study of 311 cases of physical examination combined with fine needle aspiration in the diagnosis of breast lumps. Journal of Practical Medical Techniques. 2005, 12: 1679-1680. Wang PL, Hui JJ: A Study of 311 cases of physical examination combined with fine needle aspiration in the diagnosis of breast lumps. Journal of Practical Medical Techniques. 2005, 12: 1679-1680.
68.
go back to reference Chen TJ: A study of pathologic diagnosis of fine needle aspiration cytology in breast masses. China Prac Med. 2010, 5: 15-116. 10.1186/1749-8546-5-15.CrossRef Chen TJ: A study of pathologic diagnosis of fine needle aspiration cytology in breast masses. China Prac Med. 2010, 5: 15-116. 10.1186/1749-8546-5-15.CrossRef
69.
go back to reference Zeng H, Wang Y: The value of fine needle aspiration cytology in the diagnosis of breast mass. Gui Zhou Medical Journal. 1999, 23: 260-261. Zeng H, Wang Y: The value of fine needle aspiration cytology in the diagnosis of breast mass. Gui Zhou Medical Journal. 1999, 23: 260-261.
70.
go back to reference Jia ZG, Pan RQ: Analysis of 100 cases of fine needle aspiration cytology in the diagnosis of breast mass. Practical Surgery Journal. 1986, 6: 583-584. Jia ZG, Pan RQ: Analysis of 100 cases of fine needle aspiration cytology in the diagnosis of breast mass. Practical Surgery Journal. 1986, 6: 583-584.
71.
go back to reference Ma LA, Yang HY: Value of fine needle aspiration cytology in the diagnosis of breast mass. Maternal and Child Health in China. 2010, 25: 2147-2148. Ma LA, Yang HY: Value of fine needle aspiration cytology in the diagnosis of breast mass. Maternal and Child Health in China. 2010, 25: 2147-2148.
72.
go back to reference Huang YJ, Shu QJ: The role of fine needle aspiration cytology in the diagnosis of breast lesions. Oncology Journal. 2003, 9: 120-121. Huang YJ, Shu QJ: The role of fine needle aspiration cytology in the diagnosis of breast lesions. Oncology Journal. 2003, 9: 120-121.
73.
go back to reference Zhang GX, Yong DY: Cytological diagnosis of breast tumor by fine needle aspiration:experience of 64 cases. Journal of Shan Xi College of Traditional Chinese Medicine. 1996, 19: 19- Zhang GX, Yong DY: Cytological diagnosis of breast tumor by fine needle aspiration:experience of 64 cases. Journal of Shan Xi College of Traditional Chinese Medicine. 1996, 19: 19-
74.
go back to reference Yu KQ, Yang WQ, Yang JM: The role of fine needle aspiration cytology in the diagnosis of breast tumor. Shandong Medical Journal. 2006, 46: 70-71. Yu KQ, Yang WQ, Yang JM: The role of fine needle aspiration cytology in the diagnosis of breast tumor. Shandong Medical Journal. 2006, 46: 70-71.
75.
go back to reference Jiang Y, Wang Q, Wang GY, Zhou LM, Lin TJ: The research of fine needle aspiration cytology in the diagnosis of breast tumor. Guang Zhou Medical Journal. 2008, 39: 44-45. Jiang Y, Wang Q, Wang GY, Zhou LM, Lin TJ: The research of fine needle aspiration cytology in the diagnosis of breast tumor. Guang Zhou Medical Journal. 2008, 39: 44-45.
76.
go back to reference Whiting P, Rutjes AW, Reitsma JB, Bossuyt PMM, Kleijnen J: The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003, 3: 25-10.1186/1471-2288-3-25.CrossRefPubMedPubMedCentral Whiting P, Rutjes AW, Reitsma JB, Bossuyt PMM, Kleijnen J: The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003, 3: 25-10.1186/1471-2288-3-25.CrossRefPubMedPubMedCentral
77.
go back to reference Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuy PMM: The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol. 2003, 56: 1129-1135. 10.1016/S0895-4356(03)00177-X.CrossRefPubMed Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuy PMM: The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol. 2003, 56: 1129-1135. 10.1016/S0895-4356(03)00177-X.CrossRefPubMed
78.
go back to reference Deeks JJ: Systematic reviews of evaluations of diagnostic and screening tests. Systematic reviews in health care: meta-analysis in context. Edited by: Egger M, Smith GD, Altman DG. 2001, London, UK: BMJ Publishing Group, 248-282.CrossRef Deeks JJ: Systematic reviews of evaluations of diagnostic and screening tests. Systematic reviews in health care: meta-analysis in context. Edited by: Egger M, Smith GD, Altman DG. 2001, London, UK: BMJ Publishing Group, 248-282.CrossRef
79.
go back to reference Jaeschke R, Guyatt G, Lijmer J: Diagnostic tests. Users' guides to the medical literature: a manual for evidence-based clinical practice. Edited by: Guyatt G, Rennie D. 2002, Chicago, IL: AMA Press, 121-140. Jaeschke R, Guyatt G, Lijmer J: Diagnostic tests. Users' guides to the medical literature: a manual for evidence-based clinical practice. Edited by: Guyatt G, Rennie D. 2002, Chicago, IL: AMA Press, 121-140.
80.
go back to reference Lee HC, Ooi PJLL, Poh WT, Wong CY: Impact of inadequate fine-needle aspiration cytology on outcome of patients with papable breast lesions. Aust NZ J Surg. 2000, 70: 656-659. 10.1046/j.1440-1622.2000.01920.x.CrossRef Lee HC, Ooi PJLL, Poh WT, Wong CY: Impact of inadequate fine-needle aspiration cytology on outcome of patients with papable breast lesions. Aust NZ J Surg. 2000, 70: 656-659. 10.1046/j.1440-1622.2000.01920.x.CrossRef
81.
go back to reference Petitti DB: Approaches to heterogeneity in meta-analysis. Stat Med. 2001, 20: 3625-3633. 10.1002/sim.1091.CrossRefPubMed Petitti DB: Approaches to heterogeneity in meta-analysis. Stat Med. 2001, 20: 3625-3633. 10.1002/sim.1091.CrossRefPubMed
Metadata
Title
Diagnostic value of fine-needle aspiration biopsy for breast mass: a systematic review and meta-analysis
Authors
Ying-Hua Yu
Wei Wei
Jian-Lun Liu
Publication date
01-12-2012
Publisher
BioMed Central
Published in
BMC Cancer / Issue 1/2012
Electronic ISSN: 1471-2407
DOI
https://doi.org/10.1186/1471-2407-12-41

Other articles of this Issue 1/2012

BMC Cancer 1/2012 Go to the issue
Webinar | 19-02-2024 | 17:30 (CET)

Keynote webinar | Spotlight on antibody–drug conjugates in cancer

Antibody–drug conjugates (ADCs) are novel agents that have shown promise across multiple tumor types. Explore the current landscape of ADCs in breast and lung cancer with our experts, and gain insights into the mechanism of action, key clinical trials data, existing challenges, and future directions.

Dr. Véronique Diéras
Prof. Fabrice Barlesi
Developed by: Springer Medicine