Skip to main content
Top
Published in: La radiologia medica 8/2018

01-08-2018 | MAGNETIC RESONANCE IMAGING

Diagnostic performance of shoulder magnetic resonance arthrography for labral tears having surgery as reference: comparison of high-resolution isotropic 3D sequence (THRIVE) with standard protocol

Authors: Sun Hwa Lee, Seong Jong Yun, Youngno Yoon

Published in: La radiologia medica | Issue 8/2018

Login to get access

Abstract

Purpose

To compare the diagnostic performance of T1 high-resolution isotropic volume excitation (THRIVE) sequence with that of a standard protocol for direct shoulder magnetic resonance arthrography (MRA) for the diagnosis of superior labral anterior-to-posterior (SLAP) and Bankart lesions, using arthroscopy findings as a reference standard.

Materials and methods

We retrospectively studied 84 patients who underwent direct shoulder 3T MRA using THRIVE and two-dimensional three-plane proton-density fat-suppressed (2D-PD-FS) sequences. One reviewer evaluated the contrast-to-noise ratio (CNR) as a quantitative image quality. Other two reviewers independently evaluated the subjective image noise, image sharpness, and radiologic diagnosis as qualitative image quality. Arthroscopic surgical findings were considered the reference standard. Wilcoxon rank sum, Chi-square/Fisher’s exact, and DeLong’s tests, as well as intraclass correlation coefficients (ICCs) were used to evaluate differences between THRIVE and 2D-PD-FS images.

Results

THRIVE images had significantly higher CNR (p < 0.001), and subjective ratings of image noise (p = 0.009) and sharpness (p = 0.039) than 2D-PD-FS images (p < 0.001). THRIVE images had similar (p ≥ 0.18) diagnostic performance (sensitivity, 93.0–97.2%; specificity, 95.8–100%; accuracy, 95.2–97.6%) for the diagnosis of SLAP and Bankart lesions with excellent agreement (ICC = 0.898–0.942) when compared to 2D-PD-FS images (sensitivity, 86.1–91.7%; specificity, 93.8–95.8%; accuracy, 90.5–92.9%; agreement, ICC = 0.782–0.858). The scan time was reduced by 69% for THRIVE sequence compared to 2D-PD-FS sequence (2 min 40 s vs. 8 min 40 s).

Conclusion

The THRIVE sequence may be helpful in the diagnosis of SLAP and Bankart lesions, and may be routinely used during direct shoulder 3T MRA.
Literature
1.
go back to reference Sebro R, Oliveira A, Palmer WE (2014) MR arthrography of the shoulder: technical update and clinical applications. Semin Musculoskelet Radiol 18:352–364CrossRefPubMed Sebro R, Oliveira A, Palmer WE (2014) MR arthrography of the shoulder: technical update and clinical applications. Semin Musculoskelet Radiol 18:352–364CrossRefPubMed
3.
go back to reference Ng AW, Hung EH, Griffith JF, Tong CS (2013) Cho CC (2013) comparison of ultrasound versus fluoroscopic guided rotator cuff interval approach for MR arthrography. Clin Imaging 37:548–5534CrossRefPubMed Ng AW, Hung EH, Griffith JF, Tong CS (2013) Cho CC (2013) comparison of ultrasound versus fluoroscopic guided rotator cuff interval approach for MR arthrography. Clin Imaging 37:548–5534CrossRefPubMed
4.
go back to reference Lee YH, Choi YR, Kim S, Song HT, Suh JS (2013) Intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist: comparison of isovolumetric 3D-THRIVE sequence MR arthrography and conventional MR image at 3 T. Magn Reson Imaging 31:221–226CrossRefPubMed Lee YH, Choi YR, Kim S, Song HT, Suh JS (2013) Intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist: comparison of isovolumetric 3D-THRIVE sequence MR arthrography and conventional MR image at 3 T. Magn Reson Imaging 31:221–226CrossRefPubMed
5.
go back to reference Hussain SM (2008) UNMC advances 3.0T abdominal imaging. Field Strength Issue 35:8–13 Hussain SM (2008) UNMC advances 3.0T abdominal imaging. Field Strength Issue 35:8–13
6.
go back to reference Wieslander SB, Rappeport ED, Lausten GS, Thomsen HS (1998) Multiplanar reconstruction in MR imaging of the knee. Comparison with standard sagittal and coronal images. Acta Radiol 39:116–119PubMed Wieslander SB, Rappeport ED, Lausten GS, Thomsen HS (1998) Multiplanar reconstruction in MR imaging of the knee. Comparison with standard sagittal and coronal images. Acta Radiol 39:116–119PubMed
7.
go back to reference Kijowski R, Davis KW, Woods MA et al (2009) Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging—diagnostic performance compared with that of conventional MR imaging at 3.0 T. Radiology 252:486–495CrossRefPubMed Kijowski R, Davis KW, Woods MA et al (2009) Knee joint: comprehensive assessment with 3D isotropic resolution fast spin-echo MR imaging—diagnostic performance compared with that of conventional MR imaging at 3.0 T. Radiology 252:486–495CrossRefPubMed
8.
go back to reference Jung JY, Jee WH, Park MY, Lee SY, Kim JM (2012) Meniscal tear configurations: categorization with 3D isotropic turbo spin-echo MRI compared with conventional MRI at 3 T. Am J Roentgenol 198:W173–W180CrossRef Jung JY, Jee WH, Park MY, Lee SY, Kim JM (2012) Meniscal tear configurations: categorization with 3D isotropic turbo spin-echo MRI compared with conventional MRI at 3 T. Am J Roentgenol 198:W173–W180CrossRef
9.
go back to reference Wagner SC, Schweitzer ME, Weishaupt D (2001) Temporal behavior of intraarticular gadolinium. J Comput Assist Tomogr 25:661–670CrossRefPubMed Wagner SC, Schweitzer ME, Weishaupt D (2001) Temporal behavior of intraarticular gadolinium. J Comput Assist Tomogr 25:661–670CrossRefPubMed
10.
go back to reference Kopka L, Funke M, Fischer U, Keating D, Oestmann J, Grabbe E (1994) MR arthrography of the shoulder with gadopentetate dimeglumine: influence of concentration, iodinated contrast material, and time on signal intensity. Am J Roentgenol 163:621–623CrossRef Kopka L, Funke M, Fischer U, Keating D, Oestmann J, Grabbe E (1994) MR arthrography of the shoulder with gadopentetate dimeglumine: influence of concentration, iodinated contrast material, and time on signal intensity. Am J Roentgenol 163:621–623CrossRef
11.
go back to reference Snyder SJ, Karzel RP, Del Pizzo W, Ferkel RD, Friedman MJ (1990) SLAP lesions of the shoulder. Arthroscopy 6:274–279CrossRefPubMed Snyder SJ, Karzel RP, Del Pizzo W, Ferkel RD, Friedman MJ (1990) SLAP lesions of the shoulder. Arthroscopy 6:274–279CrossRefPubMed
13.
go back to reference DeLong ER, DeLong DM, Clarke-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837–845CrossRefPubMed DeLong ER, DeLong DM, Clarke-Pearson DL (1988) Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44:837–845CrossRefPubMed
14.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
15.
go back to reference Kim MS, Park CS, Lee EJ et al (2010) Magnetic resonance colonography: comparison between T1 high resolution isotropic volume excitation (THRIVE) and balanced fast field echo (bFFE) using an air enema or water gadolinium enema. Clin Radiol 65:319–324CrossRefPubMed Kim MS, Park CS, Lee EJ et al (2010) Magnetic resonance colonography: comparison between T1 high resolution isotropic volume excitation (THRIVE) and balanced fast field echo (bFFE) using an air enema or water gadolinium enema. Clin Radiol 65:319–324CrossRefPubMed
16.
go back to reference Foti G, Avanzi P, Mantovani W et al (2017) MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences. Radiol Med 122:353–360CrossRefPubMed Foti G, Avanzi P, Mantovani W et al (2017) MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences. Radiol Med 122:353–360CrossRefPubMed
17.
go back to reference Jung JY, Jee WH, Park MY, Lee SY, Kim YS (2013) SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences. Eur Radiol 23:487–495CrossRefPubMed Jung JY, Jee WH, Park MY, Lee SY, Kim YS (2013) SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences. Eur Radiol 23:487–495CrossRefPubMed
18.
go back to reference Jung JY, Yoon YC, Choi SH, Kwon JW, Yoo J, Choe BK (2009) Three-dimensional isotropic shoulder MR arthrography: comparison with two-dimensional MR arthrography for the diagnosis of labral lesions at 3.0 T. Radiology 250:498–505CrossRefPubMed Jung JY, Yoon YC, Choi SH, Kwon JW, Yoo J, Choe BK (2009) Three-dimensional isotropic shoulder MR arthrography: comparison with two-dimensional MR arthrography for the diagnosis of labral lesions at 3.0 T. Radiology 250:498–505CrossRefPubMed
19.
go back to reference Lee JH, Yoon YC, Jee S, Kwon JW, Cha JG, Yoo JC (2014) Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears. Korean J Radiol 15:771–780CrossRefPubMedPubMedCentral Lee JH, Yoon YC, Jee S, Kwon JW, Cha JG, Yoo JC (2014) Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears. Korean J Radiol 15:771–780CrossRefPubMedPubMedCentral
20.
go back to reference Lee YH, Kim AH, Suh JS (2014) Magnetic resonance visualization of surgical classification of rotator cuff tear: comparison with three-dimensional shoulder magnetic resonance arthrography at 3.0 T. Clin Imaging 38:858–863CrossRefPubMed Lee YH, Kim AH, Suh JS (2014) Magnetic resonance visualization of surgical classification of rotator cuff tear: comparison with three-dimensional shoulder magnetic resonance arthrography at 3.0 T. Clin Imaging 38:858–863CrossRefPubMed
21.
go back to reference Oh DK, Yoon YC, Kwon JW et al (2009) Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: a prospective study. Am J Roentgenol 192:473–479CrossRef Oh DK, Yoon YC, Kwon JW et al (2009) Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: a prospective study. Am J Roentgenol 192:473–479CrossRef
22.
go back to reference Park HJ, Lee SY, Rho MH, Kwon HJ, Kim MS, Chung EC (2015) The usefulness of the three-dimensional enhanced T1 high-resolution isotropic volume excitation MR in the evaluation of shoulder pathology: comparison with two-dimensional enhanced T1 fat saturation MR. Br J Radiol 88:20140830CrossRefPubMedPubMedCentral Park HJ, Lee SY, Rho MH, Kwon HJ, Kim MS, Chung EC (2015) The usefulness of the three-dimensional enhanced T1 high-resolution isotropic volume excitation MR in the evaluation of shoulder pathology: comparison with two-dimensional enhanced T1 fat saturation MR. Br J Radiol 88:20140830CrossRefPubMedPubMedCentral
23.
go back to reference Park SY, Lee IS, Park SK, Cheon SJ, Ahn JM, Song JW (2014) Comparison of three-dimensional isotropic and conventional MR arthrography with respect to the diagnosis of rotator cuff and labral lesions: focus on isotropic fat-suppressed proton density and VIBE sequences. Clin Radiol 69:e173–e182CrossRefPubMed Park SY, Lee IS, Park SK, Cheon SJ, Ahn JM, Song JW (2014) Comparison of three-dimensional isotropic and conventional MR arthrography with respect to the diagnosis of rotator cuff and labral lesions: focus on isotropic fat-suppressed proton density and VIBE sequences. Clin Radiol 69:e173–e182CrossRefPubMed
24.
go back to reference Jung JY, Jee WH, Park MY, Lee SY, Kim YS (2012) Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences. Skeletal Radiol 41:1401–1410CrossRefPubMed Jung JY, Jee WH, Park MY, Lee SY, Kim YS (2012) Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences. Skeletal Radiol 41:1401–1410CrossRefPubMed
25.
go back to reference Park HJ, Lee SY, Kim MS et al (2015) Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR. Br J Radiol 88:20140147CrossRefPubMedPubMedCentral Park HJ, Lee SY, Kim MS et al (2015) Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR. Br J Radiol 88:20140147CrossRefPubMedPubMedCentral
26.
go back to reference Dietrich TJ, Zanetti M, Saupe N, Pfirrmann CW, Fucentese SF, Hodler J (2010) Articular cartilage and labral lesions of the glenohumeral joint: diagnostic performance of 3D water-excitation true FISP MR arthrography. Skeletal Radiol 39:473–480CrossRefPubMed Dietrich TJ, Zanetti M, Saupe N, Pfirrmann CW, Fucentese SF, Hodler J (2010) Articular cartilage and labral lesions of the glenohumeral joint: diagnostic performance of 3D water-excitation true FISP MR arthrography. Skeletal Radiol 39:473–480CrossRefPubMed
27.
go back to reference Magee T (2007) Can isotropic fast gradient echo imaging be substituted for conventional T1 weighted sequences in shoulder MR arthrography at 3 Tesla? J Magn Reson Imaging 26:118–122CrossRefPubMed Magee T (2007) Can isotropic fast gradient echo imaging be substituted for conventional T1 weighted sequences in shoulder MR arthrography at 3 Tesla? J Magn Reson Imaging 26:118–122CrossRefPubMed
28.
go back to reference Lee MJ, Motamedi K, Chow K, Seeger LL (2008) Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum. Skeletal Radiol 37:19–25CrossRefPubMed Lee MJ, Motamedi K, Chow K, Seeger LL (2008) Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum. Skeletal Radiol 37:19–25CrossRefPubMed
29.
go back to reference Gottsegen CJ, Merkle AN, Bencardino JT, Gyftopoulos S (2017) Advanced MRI techniques of the shoulder joint: current applications in clinical practice. Am J Roentgenol 209:544–551CrossRef Gottsegen CJ, Merkle AN, Bencardino JT, Gyftopoulos S (2017) Advanced MRI techniques of the shoulder joint: current applications in clinical practice. Am J Roentgenol 209:544–551CrossRef
30.
go back to reference Rastogi AK, Davis KW, Ross A, Rosas HG (2016) Fundamentals of joint injection. Am J Roentgenol 207:484–494CrossRef Rastogi AK, Davis KW, Ross A, Rosas HG (2016) Fundamentals of joint injection. Am J Roentgenol 207:484–494CrossRef
31.
go back to reference Fox MG, Petrey WB, Alford B, Huynh BH, Patrie JT, Anderson MW (2012) Shoulder MR arthrography: intraarticular anesthetic reduces periprocedural pain and major motion artifacts but does not decrease imaging time. Radiology 262:576–583CrossRefPubMed Fox MG, Petrey WB, Alford B, Huynh BH, Patrie JT, Anderson MW (2012) Shoulder MR arthrography: intraarticular anesthetic reduces periprocedural pain and major motion artifacts but does not decrease imaging time. Radiology 262:576–583CrossRefPubMed
32.
go back to reference Lee SH, Lee YH, Song HT, Suh JS (2017) Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing. Magn Reson Imaging 42:152–157CrossRefPubMed Lee SH, Lee YH, Song HT, Suh JS (2017) Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing. Magn Reson Imaging 42:152–157CrossRefPubMed
33.
go back to reference Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRefPubMed Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRefPubMed
34.
go back to reference Ugas MA, Huynh BH, Fox MG, Patrie JT, Gaskin CM (2014) MR arthrography: impact of steroids, local anesthetics, and iodinated contrast material on gadolinium signal intensity in phantoms at 1.5 and 3.0 T. Radiology 272:475–483CrossRefPubMed Ugas MA, Huynh BH, Fox MG, Patrie JT, Gaskin CM (2014) MR arthrography: impact of steroids, local anesthetics, and iodinated contrast material on gadolinium signal intensity in phantoms at 1.5 and 3.0 T. Radiology 272:475–483CrossRefPubMed
35.
go back to reference Messina C, Banfi G, Aliprandi A (2016) Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now. Eur Radiol 26:1221–1225CrossRefPubMed Messina C, Banfi G, Aliprandi A (2016) Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now. Eur Radiol 26:1221–1225CrossRefPubMed
37.
go back to reference Messina C, Banfi G, Orlandi D et al (2016) Ultrasound-guided interventional procedures around the shoulder. Br J Radiol 89:20150372CrossRefPubMed Messina C, Banfi G, Orlandi D et al (2016) Ultrasound-guided interventional procedures around the shoulder. Br J Radiol 89:20150372CrossRefPubMed
Metadata
Title
Diagnostic performance of shoulder magnetic resonance arthrography for labral tears having surgery as reference: comparison of high-resolution isotropic 3D sequence (THRIVE) with standard protocol
Authors
Sun Hwa Lee
Seong Jong Yun
Youngno Yoon
Publication date
01-08-2018
Publisher
Springer Milan
Published in
La radiologia medica / Issue 8/2018
Print ISSN: 0033-8362
Electronic ISSN: 1826-6983
DOI
https://doi.org/10.1007/s11547-018-0879-2

Other articles of this Issue 8/2018

La radiologia medica 8/2018 Go to the issue