Skip to main content
Top
Published in: European Radiology 10/2018

01-10-2018 | Musculoskeletal

Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis

Authors: Chong Hyun Suh, Seong Jong Yun, Wook Jin, Sun Hwa Lee, So Young Park, Chang-Woo Ryu

Published in: European Radiology | Issue 10/2018

Login to get access

Abstract

Objectives

The aim of this systematic review and meta-analysis was to assess the sensitivity and specificity of dual-energy CT (DECT) for the detection of bone marrow oedema (BME).

Methods

An electronic search of the PubMed and EMBASE databases was conducted. Bivariate modelling and hierarchical summary receiver-operating characteristic modelling were performed to evaluate the overall diagnostic performance of DECT for BME. Subgroup analysis was performed according to the assessment type (qualitative vs. quantitative) and anatomical location (spine vs. appendicular skeleton). Meta-regression analyses were performed according to the subject, study, and DECT characteristics.

Results

Twelve eligible studies (1901 lesions, 450 patients) were included. DECT exhibited a pooled sensitivity of 0.85 [95% confidence interval (CI): 0.78–0.90] and a pooled specificity of 0.97 (95% CI: 0.92–0.98) for BME detection. In addition, the diagnostic performance of qualitative assessment (sensitivity, 0.85; specificity, 0.97) was higher than that of quantitative assessment (sensitivity, 0.84; specificity, 0.88) of DECT findings. The diagnostic performance of DECT for the spine (sensitivity, 0.84; specificity, 0.98) and appendicular skeleton (sensitivity, 0.84; specificity, 0.93) were excellent. According to meta-regression analysis, the use of a tin filter, ≥ 2 image planes, and a slice thickness < 1 mm tended to exhibit higher sensitivity and hyperacute stage BME (< 24 h) tended to exhibit lower sensitivity.

Conclusions

These findings indicate that DECT has excellent sensitivity and specificity for BME detection. Qualitative assessment of DECT findings obtained using a tin filter, ≥ 2 image planes, and a 0.5-1-mm slice thickness in the acute stage BME (≥24 h) is recommended for more sensitive diagnosis.

Key Points

• Overall, DECT is useful for the detection of BME (sensitivity, 85%; specificity-97%).
• Qualitative assessment (sensitivity-85%; specificity-97%) is more accurate than quantitative assessment (sensitivity-84%; specificity-88%).
• DECT showed excellent diagnostic performance for both the spine/appendicular skeleton (sensitivity-84%/84%; specificity-98%/93%).
Appendix
Available only for authorised users
Literature
1.
go back to reference Boks SS, Vroegindeweij D, Koes BW, Hunink MG, Bierma-Zeinstra SM (2006) Follow-up of occult bone lesions detected at MR imaging: systematic review. Radiology 238:853–862CrossRef Boks SS, Vroegindeweij D, Koes BW, Hunink MG, Bierma-Zeinstra SM (2006) Follow-up of occult bone lesions detected at MR imaging: systematic review. Radiology 238:853–862CrossRef
2.
go back to reference Carberry GA, Pooler BD, Binkley N, Lauder TB, Bruce RJ, Pickhardt PJ (2013) Unreported vertebral body compression fractures at abdominal multidetector CT. Radiology 268:120–126CrossRef Carberry GA, Pooler BD, Binkley N, Lauder TB, Bruce RJ, Pickhardt PJ (2013) Unreported vertebral body compression fractures at abdominal multidetector CT. Radiology 268:120–126CrossRef
3.
go back to reference Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C et al (2006) Occult scaphoid fractures: comparison of multidetector CT and MR imaging--initial experience. Radiology 240:169–176CrossRef Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C et al (2006) Occult scaphoid fractures: comparison of multidetector CT and MR imaging--initial experience. Radiology 240:169–176CrossRef
4.
go back to reference Geijer M, Dunker D, Collin D, Gothlin JH (2012) Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture. Acta Radiol 53:197–202CrossRef Geijer M, Dunker D, Collin D, Gothlin JH (2012) Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture. Acta Radiol 53:197–202CrossRef
5.
go back to reference Mandalia V, Fogg AJ, Chari R, Murray J, Beale A, Henson JH (2005) Bone bruising of the knee. Clin Radiol 60:627–636CrossRef Mandalia V, Fogg AJ, Chari R, Murray J, Beale A, Henson JH (2005) Bone bruising of the knee. Clin Radiol 60:627–636CrossRef
6.
go back to reference Pache G, Krauss B, Strohm P et al (2010) Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study. Radiology 256:617–624CrossRef Pache G, Krauss B, Strohm P et al (2010) Dual-energy CT virtual noncalcium technique: detecting posttraumatic bone marrow lesions--feasibility study. Radiology 256:617–624CrossRef
7.
go back to reference Diekhoff T, Hermann KG, Pumberger M, Hamm B, Putzier M, Fuchs M (2017) Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: a prospective feasibility study on a single- source volume CT scanner. Eur J Radiol 87:59–65CrossRef Diekhoff T, Hermann KG, Pumberger M, Hamm B, Putzier M, Fuchs M (2017) Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: a prospective feasibility study on a single- source volume CT scanner. Eur J Radiol 87:59–65CrossRef
8.
go back to reference Diekhoff T, Scheel M, Hermann S, Mews J, Hamm B, Hermann KA (2017) Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout. Skeletal Radiol 46:185–190CrossRef Diekhoff T, Scheel M, Hermann S, Mews J, Hamm B, Hermann KA (2017) Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout. Skeletal Radiol 46:185–190CrossRef
9.
go back to reference Guggenberger R, Gnannt R, Hodler J et al (2012) Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging. Radiology 264:164–173CrossRef Guggenberger R, Gnannt R, Hodler J et al (2012) Diagnostic performance of dual-energy CT for the detection of traumatic bone marrow lesions in the ankle: comparison with MR imaging. Radiology 264:164–173CrossRef
10.
go back to reference Kellock TT, Nicolaou S, Kim SSY et al (2017) Detection of bone marrow edema in nondisplaced hip fractures: utility of a virtual noncalcium dual-energy CT application. Radiology 284:798–805CrossRef Kellock TT, Nicolaou S, Kim SSY et al (2017) Detection of bone marrow edema in nondisplaced hip fractures: utility of a virtual noncalcium dual-energy CT application. Radiology 284:798–805CrossRef
11.
go back to reference Wang CK, Tsai JM, Chuang MT, Wang MT, Huang KY, Lin RM (2013) Bone marrow edema in vertebral compression fractures: detection with dual-energy CT. Radiology 269:525–533CrossRef Wang CK, Tsai JM, Chuang MT, Wang MT, Huang KY, Lin RM (2013) Bone marrow edema in vertebral compression fractures: detection with dual-energy CT. Radiology 269:525–533CrossRef
12.
go back to reference Liberati A, Altman DG, Tetzlaff J et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 6:e1000100CrossRef Liberati A, Altman DG, Tetzlaff J et al (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 6:e1000100CrossRef
13.
go back to reference Whiting PF, Rutjes AW, Westwood ME et al (2011) QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 155:529–536CrossRef Whiting PF, Rutjes AW, Westwood ME et al (2011) QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 155:529–536CrossRef
14.
go back to reference Kim KW, Lee J, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part I. General guidance and tips. Korean J Radiol 16:1175–1187CrossRef Kim KW, Lee J, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part I. General guidance and tips. Korean J Radiol 16:1175–1187CrossRef
15.
go back to reference Lee J, Kim KW, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part II. Statistical methods of meta-analysis. Korean J Radiol 16:1188–1196CrossRef Lee J, Kim KW, Choi SH, Huh J, Park SH (2015) Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: a practical review for clinical researchers-part II. Statistical methods of meta-analysis. Korean J Radiol 16:1188–1196CrossRef
16.
go back to reference Suh CH, Park SH (2016) Successful publication of systematic review and meta-analysis of studies evaluating diagnostic test accuracy. Korean J Radiol 17:5–6CrossRef Suh CH, Park SH (2016) Successful publication of systematic review and meta-analysis of studies evaluating diagnostic test accuracy. Korean J Radiol 17:5–6CrossRef
18.
go back to reference Deville WL, Buntinx F, Bouter LM et al (2002) Conducting systematic reviews of diagnostic studies: didactic guidelines. BMC Med Res Methodol 2:9CrossRef Deville WL, Buntinx F, Bouter LM et al (2002) Conducting systematic reviews of diagnostic studies: didactic guidelines. BMC Med Res Methodol 2:9CrossRef
19.
go back to reference Deeks JJ, Macaskill P, Irwig L (2005) The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 58:882–893CrossRef Deeks JJ, Macaskill P, Irwig L (2005) The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 58:882–893CrossRef
20.
go back to reference Ai S, Qu M, Glazebrook KN et al (2014) Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting. Skeletal Radiol 43:1289–1295CrossRef Ai S, Qu M, Glazebrook KN et al (2014) Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting. Skeletal Radiol 43:1289–1295CrossRef
21.
go back to reference Dareez NM, Dahlslett KH, Engesland E, Lindland ES (2017) Scaphoid fracture: bone marrow edema detected with dual-energy CT virtual non-calcium images and confirmed with MRI. Skeletal Radiol 46:1753–1756CrossRef Dareez NM, Dahlslett KH, Engesland E, Lindland ES (2017) Scaphoid fracture: bone marrow edema detected with dual-energy CT virtual non-calcium images and confirmed with MRI. Skeletal Radiol 46:1753–1756CrossRef
22.
go back to reference Pache G, Bulla S, Baumann T et al (2012) Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique. Acad Radiol 19:1539–1545CrossRef Pache G, Bulla S, Baumann T et al (2012) Dose reduction does not affect detection of bone marrow lesions with dual-energy CT virtual noncalcium technique. Acad Radiol 19:1539–1545CrossRef
23.
go back to reference Biondi M, Vanzi E, De Otto G et al (2016) Water/cortical bone decomposition: a new approach in dual energy CT imaging for bone marrow oedema detection. A feasibility study. Phys Med 32:1712–1716CrossRef Biondi M, Vanzi E, De Otto G et al (2016) Water/cortical bone decomposition: a new approach in dual energy CT imaging for bone marrow oedema detection. A feasibility study. Phys Med 32:1712–1716CrossRef
24.
go back to reference Bierry G, Venkatasamy A, Kremer S, Dosch JC, Dietemann JL (2014) Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI. Skeletal Radiol 43:485–492CrossRef Bierry G, Venkatasamy A, Kremer S, Dosch JC, Dietemann JL (2014) Dual-energy CT in vertebral compression fractures: performance of visual and quantitative analysis for bone marrow edema demonstration with comparison to MRI. Skeletal Radiol 43:485–492CrossRef
25.
go back to reference Cao JX, Wang YM, Kong XQ, Yang C, Wang P (2015) Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images. Eur J Radiol 84:1109–1115CrossRef Cao JX, Wang YM, Kong XQ, Yang C, Wang P (2015) Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images. Eur J Radiol 84:1109–1115CrossRef
26.
go back to reference Karaca L, Yuceler Z, Kantarci M et al (2016) The feasibility of dual-energy CT in differentiation of vertebral compression fractures. Br J Radiol 89:20150300CrossRef Karaca L, Yuceler Z, Kantarci M et al (2016) The feasibility of dual-energy CT in differentiation of vertebral compression fractures. Br J Radiol 89:20150300CrossRef
27.
go back to reference Kaup M, Wichmann JL, Scholtz JE et al (2016) Dual-energy CT-based display of bone marrow edema in osteoporotic vertebral compression fractures: impact on diagnostic accuracy of radiologists with varying levels of experience in correlation to MR imaging. Radiology 280:510–519CrossRef Kaup M, Wichmann JL, Scholtz JE et al (2016) Dual-energy CT-based display of bone marrow edema in osteoporotic vertebral compression fractures: impact on diagnostic accuracy of radiologists with varying levels of experience in correlation to MR imaging. Radiology 280:510–519CrossRef
28.
go back to reference Na D, Hong SJ, Yoon MA et al (2016) Spinal bone bruise: can computed tomography (CT) enable accurate diagnosis? Acad Radiol 23:1376–1383CrossRef Na D, Hong SJ, Yoon MA et al (2016) Spinal bone bruise: can computed tomography (CT) enable accurate diagnosis? Acad Radiol 23:1376–1383CrossRef
29.
go back to reference Petritsch B, Kosmala A, Weng AM et al (2017) Vertebral compression fractures: third-generation dual-energy CT for detection of bone marrow edema at visual and quantitative analyses. Radiology 284:161–168CrossRef Petritsch B, Kosmala A, Weng AM et al (2017) Vertebral compression fractures: third-generation dual-energy CT for detection of bone marrow edema at visual and quantitative analyses. Radiology 284:161–168CrossRef
30.
go back to reference Reddy T, McLaughlin PD, Mallinson PI et al (2015) Detection of occult, undisplaced hip fractures with a dual-energy CT algorithm targeted to detection of bone marrow edema. Emerg Radiol 22:25–29CrossRef Reddy T, McLaughlin PD, Mallinson PI et al (2015) Detection of occult, undisplaced hip fractures with a dual-energy CT algorithm targeted to detection of bone marrow edema. Emerg Radiol 22:25–29CrossRef
31.
go back to reference Van Abbema JK, Van der Schaaf A, Kristanto W, Groen JM, Greuter MJ (2012) Feasibility and accuracy of tissue characterization with dual source computed tomography. Phys Med 28:25–32CrossRef Van Abbema JK, Van der Schaaf A, Kristanto W, Groen JM, Greuter MJ (2012) Feasibility and accuracy of tissue characterization with dual source computed tomography. Phys Med 28:25–32CrossRef
32.
go back to reference Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517CrossRef Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517CrossRef
33.
go back to reference Mallinson PI, Coupal TM, McLaughlin PD, Nicolaou S, Munk PL, Ouellette HA (2016) Dual-energy CT for the musculoskeletal system. Radiology 281:690–707CrossRef Mallinson PI, Coupal TM, McLaughlin PD, Nicolaou S, Munk PL, Ouellette HA (2016) Dual-energy CT for the musculoskeletal system. Radiology 281:690–707CrossRef
34.
go back to reference Nicolaou S, Liang T, Murphy DT, Korzan JR, Ouellette H, Munk P (2012) Dual-energy CT: a promising new technique for assessment of the musculoskeletal system. AJR Am J Roentgenol 199:S78–S86CrossRef Nicolaou S, Liang T, Murphy DT, Korzan JR, Ouellette H, Munk P (2012) Dual-energy CT: a promising new technique for assessment of the musculoskeletal system. AJR Am J Roentgenol 199:S78–S86CrossRef
35.
go back to reference Yang P, Wu G, Chang X (2018) Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: a meta-analysis. Eur J Radiol 99:124–129CrossRef Yang P, Wu G, Chang X (2018) Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: a meta-analysis. Eur J Radiol 99:124–129CrossRef
36.
go back to reference McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653CrossRef McCollough CH, Leng S, Yu L, Fletcher JG (2015) Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology 276:637–653CrossRef
37.
go back to reference Primak AN, Giraldo JC, Eusemann CD et al (2010) Dual-source dual-energy CT with additional tin filtration: dose and image quality evaluation in phantoms and in vivo. AJR Am J Roentgenol 195:1164–1174CrossRef Primak AN, Giraldo JC, Eusemann CD et al (2010) Dual-source dual-energy CT with additional tin filtration: dose and image quality evaluation in phantoms and in vivo. AJR Am J Roentgenol 195:1164–1174CrossRef
38.
go back to reference Li M, Qu Y, Song B (2017) Meta-analysis of dual-energy computed tomography virtual non-calcium imaging to detect bone marrow edema. Eur J Radiol 95:124–129CrossRef Li M, Qu Y, Song B (2017) Meta-analysis of dual-energy computed tomography virtual non-calcium imaging to detect bone marrow edema. Eur J Radiol 95:124–129CrossRef
39.
go back to reference Mandalia V, Henson JH (2008) Traumatic bone bruising--a review article. Eur J Radiol 67:54–61CrossRef Mandalia V, Henson JH (2008) Traumatic bone bruising--a review article. Eur J Radiol 67:54–61CrossRef
40.
go back to reference Bao S, Guo N (2017) The value of dual-energy CT noncalcium technique in the diagnosis of bone bruises. J Med Imaging 2 Bao S, Guo N (2017) The value of dual-energy CT noncalcium technique in the diagnosis of bone bruises. J Med Imaging 2
41.
go back to reference Huang W, Xu Y, Lu D et al (2015) Vertebral bone marrow edema assessed by dual-source CT noncalcium imaging. J Med Imaging 3 Huang W, Xu Y, Lu D et al (2015) Vertebral bone marrow edema assessed by dual-source CT noncalcium imaging. J Med Imaging 3
42.
go back to reference Tu N, Wen Z, Li J (2016) Study on assessment of bone marrow lesions by dual-energy computed tomography. Chin Imaging J Integr Tradit West Med 14 Tu N, Wen Z, Li J (2016) Study on assessment of bone marrow lesions by dual-energy computed tomography. Chin Imaging J Integr Tradit West Med 14
43.
go back to reference Omoumi P, Verdun FR, Becce F (2015) Optimization of radiation dose and image quality in musculoskeletal CT: emphasis on iterative reconstruction techniques (part 2). Semin Musculoskelet Radiol 19:422–430CrossRef Omoumi P, Verdun FR, Becce F (2015) Optimization of radiation dose and image quality in musculoskeletal CT: emphasis on iterative reconstruction techniques (part 2). Semin Musculoskelet Radiol 19:422–430CrossRef
Metadata
Title
Diagnostic performance of dual-energy CT for the detection of bone marrow oedema: a systematic review and meta-analysis
Authors
Chong Hyun Suh
Seong Jong Yun
Wook Jin
Sun Hwa Lee
So Young Park
Chang-Woo Ryu
Publication date
01-10-2018
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 10/2018
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5411-5

Other articles of this Issue 10/2018

European Radiology 10/2018 Go to the issue