Skip to main content
Top
Published in: Neuroradiology 8/2016

01-08-2016 | Diagnostic Neuroradiology

Diagnostic performance of CT and MRI on the detection of symptomatic intracranial dural arteriovenous fistula: a meta-analysis with indirect comparison

Authors: Yen-Heng Lin, Hsien-Ho Lin, Hon-Man Liu, Chung-Wei Lee, Ya-Fang Chen

Published in: Neuroradiology | Issue 8/2016

Login to get access

Abstract

Introduction

This study aims to review the diagnostic performance of computed tomography (CT) and magnetic resonance imaging (MRI) in symptomatic dural arteriovenous fistula (DAVF).

Methods

EMBASE, PubMed, and Cochrane Library were searched until April 2015 for studies which compared CT, MRI, or both with angiography for the detection of DAVF. The diagnostic performances of MRI and CT were indirectly compared using modality as a covariate in the analysis.

Results

Thirteen studies met our inclusion criteria. MRI had a sensitivity of 0.90 (95 % confidence interval (CI) = 0.83–0.94) and specificity of 0.94 (95 % CI = 0.90–0.96). CT had a sensitivity of 0.80 (95 % CI = 0.62–0.90) and specificity of 0.87 (95 % CI = 0.74–0.94). MRI showed better diagnostic performance than CT (p = 0.02). Contrast medium use and time-resolved MR angiography did not improve MRI diagnostic performance (p = 0.31 and 0.44, respectively).

Conclusion

Both CT and MRI had good diagnostic performance. MRI was better than CT on the detection of symptomatic intracranial dural arteriovenous fistula in the indirect comparison.
Appendix
Available only for authorised users
Literature
2.
5.
6.
go back to reference Tsai LK, Jeng JS, Wang HJ, Yip PK, Liu HM (2004) Diagnosis of intracranial dural arteriovenous fistulas by carotid duplex sonography. J Ultrasound Med : Off J Am Inst Ultrasound Med 23(6):785–791 Tsai LK, Jeng JS, Wang HJ, Yip PK, Liu HM (2004) Diagnosis of intracranial dural arteriovenous fistulas by carotid duplex sonography. J Ultrasound Med : Off J Am Inst Ultrasound Med 23(6):785–791
7.
go back to reference Tsai LK, Liu HM, Lu CJ, Jeng JS, Yip PK (2005) Carotid duplex sonography in the follow-up of intracranial dural arteriovenous fistulae. AJNR Am J Neuroradiol 26(3):625–629. doi:10.1159/000118374 PubMed Tsai LK, Liu HM, Lu CJ, Jeng JS, Yip PK (2005) Carotid duplex sonography in the follow-up of intracranial dural arteriovenous fistulae. AJNR Am J Neuroradiol 26(3):625–629. doi:10.​1159/​000118374 PubMed
12.
go back to reference Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JPA, Clarke M, Devereaux PJ, Kleijnen J, Moher D (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700. doi:10.1136/bmj.b2700 Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JPA, Clarke M, Devereaux PJ, Kleijnen J, Moher D (2009) The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 339:b2700. doi:10.​1136/​bmj.​b2700
15.
go back to reference Dietz RR, Davis WL, Harnsberger HR, Jacobs JM, Blatter DD (1994) MR imaging and MR angiography in the evaluation of pulsatile tinnitus. AJNR Am J Neuroradiol 15(5):879–889PubMed Dietz RR, Davis WL, Harnsberger HR, Jacobs JM, Blatter DD (1994) MR imaging and MR angiography in the evaluation of pulsatile tinnitus. AJNR Am J Neuroradiol 15(5):879–889PubMed
16.
go back to reference Hirai T, Korogi Y, Hamatake S, Ikushima I, Sugahara T, Sigematsu Y, Higashida Y, Takahashi M (1998) Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: comparison with contrast-enhanced CT and spin-echo MR. Am J Neuroradiol 19(2):253–259PubMed Hirai T, Korogi Y, Hamatake S, Ikushima I, Sugahara T, Sigematsu Y, Higashida Y, Takahashi M (1998) Three-dimensional FISP imaging in the evaluation of carotid cavernous fistula: comparison with contrast-enhanced CT and spin-echo MR. Am J Neuroradiol 19(2):253–259PubMed
17.
go back to reference Noguchi K, Melhem ER, Kanazawa T, Kubo M, Kuwayama N, Seto H (2004) Intracranial dural arteriovenous fistulas: evaluation with combined 3D time-of-flight MR angiography and MR DIGITAL SUBTRACTION ANGIOGRAPHY. Am J Roentgenol 182(1):183–190. doi:10.2214/ajr.182.1.1820183 CrossRef Noguchi K, Melhem ER, Kanazawa T, Kubo M, Kuwayama N, Seto H (2004) Intracranial dural arteriovenous fistulas: evaluation with combined 3D time-of-flight MR angiography and MR DIGITAL SUBTRACTION ANGIOGRAPHY. Am J Roentgenol 182(1):183–190. doi:10.​2214/​ajr.​182.​1.​1820183 CrossRef
18.
go back to reference Farb RI, Agid R, Willinsky RA, Johnstone DM, Terbrugge KG (2009) Cranial dural arteriovenous fistula: diagnosis and classification with time-resolved MR angiography at 3T. AJNR Am J Neuroradiol 30(8):1546–1551. doi:10.3174/ajnr.A1646 CrossRefPubMed Farb RI, Agid R, Willinsky RA, Johnstone DM, Terbrugge KG (2009) Cranial dural arteriovenous fistula: diagnosis and classification with time-resolved MR angiography at 3T. AJNR Am J Neuroradiol 30(8):1546–1551. doi:10.​3174/​ajnr.​A1646 CrossRefPubMed
19.
20.
21.
go back to reference Shweel M, Hamdy B (2013) Diagnostic utility of magnetic resonance imaging and magnetic resonance angiography in the radiological evaluation of pulsatile tinnitus. Am J Otolaryngol - Head Neck Med Surg 34(6):710–717. doi:10.1016/j.amjoto.2013.08.001 Shweel M, Hamdy B (2013) Diagnostic utility of magnetic resonance imaging and magnetic resonance angiography in the radiological evaluation of pulsatile tinnitus. Am J Otolaryngol - Head Neck Med Surg 34(6):710–717. doi:10.​1016/​j.​amjoto.​2013.​08.​001
22.
go back to reference Kim E, Kim JH, Choi BS, Jung C, Lee DH (2014) MRI and MR angiography findings to differentiate jugular venous reflux from cavernous dural arteriovenous fistula. Am J Roentgenol 202(4):839–846CrossRef Kim E, Kim JH, Choi BS, Jung C, Lee DH (2014) MRI and MR angiography findings to differentiate jugular venous reflux from cavernous dural arteriovenous fistula. Am J Roentgenol 202(4):839–846CrossRef
23.
go back to reference Deuschl C, Goricke S, Gramsch C, Ozkan N, Lehnerdt G, Kastrup O, Ringelstein A, Wanke I, Forsting M, Schlamann M (2015) Value of DSA in the diagnostic workup of pulsatile tinnitus. PLoS ONE 10(2):e0117814. doi:10.1371/journal.pone.0117814 Deuschl C, Goricke S, Gramsch C, Ozkan N, Lehnerdt G, Kastrup O, Ringelstein A, Wanke I, Forsting M, Schlamann M (2015) Value of DSA in the diagnostic workup of pulsatile tinnitus. PLoS ONE 10(2):e0117814. doi:10.​1371/​journal.​pone.​0117814
25.
go back to reference Narvid J, Do HM, Blevins NH, Fischbein NJ (2011) CT angiography as a screening tool for dural arteriovenous fistula in patients with pulsatile tinnitus: feasibility and test characteristics. AJNR Am J Neuroradiol 32(3):446–453. doi:10.3174/ajnr.A2328 CrossRefPubMed Narvid J, Do HM, Blevins NH, Fischbein NJ (2011) CT angiography as a screening tool for dural arteriovenous fistula in patients with pulsatile tinnitus: feasibility and test characteristics. AJNR Am J Neuroradiol 32(3):446–453. doi:10.​3174/​ajnr.​A2328 CrossRefPubMed
26.
go back to reference Zhao PF, Pamier A, Xian JF, Liang XH, Yan F, Du W, Lu H, Wang ZC (2013) Role of computed tomographic angiography in the evaluations of dural arteriovenous fistulas with pulsatile tinnitus as initial symptom. Zhonghua Yi Xue Za Zhi 93(33):2622–2626PubMed Zhao PF, Pamier A, Xian JF, Liang XH, Yan F, Du W, Lu H, Wang ZC (2013) Role of computed tomographic angiography in the evaluations of dural arteriovenous fistulas with pulsatile tinnitus as initial symptom. Zhonghua Yi Xue Za Zhi 93(33):2622–2626PubMed
27.
go back to reference Jang J, Schmitt P, Kim BY, Choi HS, Jung SL, Ahn KJ, Kim I, Paek M, Kim BS (2014) Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of dural arteriovenous fistula. Neuroradiology 56(4):305–314. doi:10.1007/s00234-014-1336-0 CrossRefPubMed Jang J, Schmitt P, Kim BY, Choi HS, Jung SL, Ahn KJ, Kim I, Paek M, Kim BS (2014) Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of dural arteriovenous fistula. Neuroradiology 56(4):305–314. doi:10.​1007/​s00234-014-1336-0 CrossRefPubMed
28.
go back to reference Josephson CB, White PM, Krishan A, Al-Shahi Salman R (2014) Computed tomography angiography or magnetic resonance angiography for detection of intracranial vascular malformations in patients with intracerebral haemorrhage. Cochrane Database Syst Rev 9:Cd009372. doi:10.1002/14651858.CD009372.pub2 PubMed Josephson CB, White PM, Krishan A, Al-Shahi Salman R (2014) Computed tomography angiography or magnetic resonance angiography for detection of intracranial vascular malformations in patients with intracerebral haemorrhage. Cochrane Database Syst Rev 9:Cd009372. doi:10.​1002/​14651858.​CD009372.​pub2 PubMed
29.
go back to reference Kobayashi A, Al-Shahi Salman R (2014) Prognosis and treatment of intracranial dural arteriovenous fistulae: a systematic review and meta-analysis. Int J Stroke : Off J Int Stroke Soc 9(6):670–677. doi:10.1111/ijs.12337 CrossRef Kobayashi A, Al-Shahi Salman R (2014) Prognosis and treatment of intracranial dural arteriovenous fistulae: a systematic review and meta-analysis. Int J Stroke : Off J Int Stroke Soc 9(6):670–677. doi:10.​1111/​ijs.​12337 CrossRef
30.
go back to reference Ma J, Li H, You C, Huang S, Ma L, Ieong C (2012) Accuracy of computed tomography angiography in detecting the underlying vascular abnormalities for spontaneous intracerebral hemorrhage: a comparative study and meta-analysis. Neurol India 60(3):299–303. doi:10.4103/0028-3886.98515 CrossRefPubMed Ma J, Li H, You C, Huang S, Ma L, Ieong C (2012) Accuracy of computed tomography angiography in detecting the underlying vascular abnormalities for spontaneous intracerebral hemorrhage: a comparative study and meta-analysis. Neurol India 60(3):299–303. doi:10.​4103/​0028-3886.​98515 CrossRefPubMed
33.
go back to reference Aggarwal R, Lloyd S (2012) Pulsatile tinnitus. Otorhinolaryngologist 5(1):7–14 Aggarwal R, Lloyd S (2012) Pulsatile tinnitus. Otorhinolaryngologist 5(1):7–14
Metadata
Title
Diagnostic performance of CT and MRI on the detection of symptomatic intracranial dural arteriovenous fistula: a meta-analysis with indirect comparison
Authors
Yen-Heng Lin
Hsien-Ho Lin
Hon-Man Liu
Chung-Wei Lee
Ya-Fang Chen
Publication date
01-08-2016
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 8/2016
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-016-1696-8

Other articles of this Issue 8/2016

Neuroradiology 8/2016 Go to the issue