Abstract

To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (< 0.05). The 3DVR-CT movie accurately provides essential information about the renal vascular anatomy before laparoscopic donor nephrectomy.
Literature
1.
go back to reference Ratner LE, Ciseck LJ, Moore RG, Cigarroa FG, Kaufman HS, Kavoussi LR (1995) Laparoscopic live donor nephrectomy. Transplantation 60:1047–1049PubMed Ratner LE, Ciseck LJ, Moore RG, Cigarroa FG, Kaufman HS, Kavoussi LR (1995) Laparoscopic live donor nephrectomy. Transplantation 60:1047–1049PubMed
2.
go back to reference Coll DM, Uzzo RG, Herts BR, Davros WJ, Wirth SL, Novick AC (1999) 3-dimensional volume rendered computerized tomography for preoperative evaluation and intraoperative treatment of patients undergoing nephron sparing surgery. J Urol 161:1097–1102. doi:10.1016/S0022-5347(01)61599-4 CrossRefPubMed Coll DM, Uzzo RG, Herts BR, Davros WJ, Wirth SL, Novick AC (1999) 3-dimensional volume rendered computerized tomography for preoperative evaluation and intraoperative treatment of patients undergoing nephron sparing surgery. J Urol 161:1097–1102. doi:10.​1016/​S0022-5347(01)61599-4 CrossRefPubMed
6.
go back to reference Kawamoto S, Montgomery RA, Lawler LP, Horton KM, Fishman EK (2003) AJR Am J Roentgenol 180:1633–1638PubMed Kawamoto S, Montgomery RA, Lawler LP, Horton KM, Fishman EK (2003) AJR Am J Roentgenol 180:1633–1638PubMed
7.
go back to reference Scatarige JC, Horton KM, Ratner LE, Fishman EK (2001) Left adrenal vein localization by 3D real-time volume-rendering CTA before laparoscopic nephrectomy in living renal donors. Abdom Imaging 26:553–556. doi:10.1007/s002610000205 CrossRefPubMed Scatarige JC, Horton KM, Ratner LE, Fishman EK (2001) Left adrenal vein localization by 3D real-time volume-rendering CTA before laparoscopic nephrectomy in living renal donors. Abdom Imaging 26:553–556. doi:10.​1007/​s002610000205 CrossRefPubMed
12.
go back to reference Bhatti AA, Chugtai A, Haslam P, Talbot D, Rix DA, Soomro NA (2005) Prospective study comparing three-dimensional computed tomography and magnetic resonance imaging for evaluating the renal vascular anatomy in potential living renal donors. BJU Int 96:1105–1108. doi:10.1111/j.1464-410X.2005.05809.x CrossRefPubMed Bhatti AA, Chugtai A, Haslam P, Talbot D, Rix DA, Soomro NA (2005) Prospective study comparing three-dimensional computed tomography and magnetic resonance imaging for evaluating the renal vascular anatomy in potential living renal donors. BJU Int 96:1105–1108. doi:10.​1111/​j.​1464-410X.​2005.​05809.​x CrossRefPubMed
13.
Metadata
Title
Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy
Authors
Shingo Yamamoto
Masao Tanooka
Kumiko Ando
Toshiko Yamano
Reiichi Ishikura
Michio Nojima
Shozo Hirota
Hiroki Shima
Publication date
01-12-2009
Publisher
Springer Netherlands
Published in
International Urology and Nephrology / Issue 4/2009
Print ISSN: 0301-1623
Electronic ISSN: 1573-2584
DOI
https://doi.org/10.1007/s11255-009-9535-z

Other articles of this Issue 4/2009

International Urology and Nephrology 4/2009 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine