Skip to main content
Top
Published in: BMC Oral Health 1/2019

Open Access 01-12-2019 | Research article

Deviations in palatal region between indirect and direct digital models: an in vivo study

Authors: Yang Zhongpeng, Xu Tianmin, Jiang Ruoping

Published in: BMC Oral Health | Issue 1/2019

Login to get access

Abstract

Background

Studies focusing on accuracy of intraoral digital models in the palatal region are scarce. The present study aimed to investigate the influence of different scanning sequences on palatal trueness and to assess deviation and distribution character of trueness in palate.

Methods

Overall, 35 participants accepted three types of procedures to acquire upper digital models. Indirect models digitalised from plaster models were considered as the reference. Two direct digital models were acquired using TRIOS 3 POD intraoral scanners, namely Groups Tr1 and Tr2, wherein intraoral scanning differed in terms of palatal scanning sequences. Based on a modified dental-level superimposition method, 3D measurements of trueness in palate and palatal vault region (PVR) for palatal stable regional superimposition in Groups Tr1 and Tr2, respectively, were performed. Absolute deviations were measured for trueness, while signed deviations were analysed for shape distortion. Colour-coded maps were used for quantitative analysis of deviation distribution pattern. Paired t test was used to analyse differences in palatal trueness between different scanning sequences. One-way repeated-measures analysis of variance and Bonferroni test were used to compare trueness measurements among different superimposition methods. Intraclass correlation coefficient (ICC) was used to verify reproducibility of the proposed method.

Results

Palatal trueness in Group Tr1 (118.59 ± 37.67 μm) was slightly less accurate than that (108.25 ± 33.83 μm) in Group Tr2 (p = 0.012 < 0.05). Trueness of PVR in Groups Tr1 (127.35 ± 54.11 μm) and Tr2 (118.17 ± 49.52 μm) did not differ significantly (p = 0.149). Moreover, no significant difference was noted in distortion of the palatal region and PVR in Groups Tr1 and Tr2 (p = 0.582 and 0.615, respectively). A similar pattern of palatal trueness was noted in a majority of participants (22/35). For 3D palatal trueness measurement, there were different applications for different superimposition methods. ICC for the proposed method was > 0.90.

Conclusions

Scanning sequences can affect palatal trueness. Palatal scanning should be initiated at the palatal side of the posterior teeth where the initial scan begins. For 3D PVR superimposition, distal boundary of the selected region should be adjusted mesially whilst referring to intraoral digital models.

Trial registration

The trial has been registered (registration No: R000039467, Trial ID: UMIN000034617, date of registration: 2018/10/24‘retrospectively registered’).
Literature
2.
go back to reference Ender A, Mehl A. Full arch scans: conventional versus digital impressions--an in-vitro study. Int J Comput Dent. 2011;14(1):11–21.PubMed Ender A, Mehl A. Full arch scans: conventional versus digital impressions--an in-vitro study. Int J Comput Dent. 2011;14(1):11–21.PubMed
3.
go back to reference Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent. 2013;109(2):121–8.CrossRef Ender A, Mehl A. Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent. 2013;109(2):121–8.CrossRef
4.
go back to reference Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent. 2016;115(3):313–20.CrossRef Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent. 2016;115(3):313–20.CrossRef
5.
go back to reference Treesh JC, Liacouras PC, Taft RM, et al. Complete-arch accuracy of intraoral scanners. J Prosthet Dent. 2018;120(3):382–8.CrossRef Treesh JC, Liacouras PC, Taft RM, et al. Complete-arch accuracy of intraoral scanners. J Prosthet Dent. 2018;120(3):382–8.CrossRef
6.
go back to reference Park JM. Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form. J Adv Prosthodont. 2016;8(5):354–62.CrossRef Park JM. Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form. J Adv Prosthodont. 2016;8(5):354–62.CrossRef
8.
go back to reference Flügge TV, Schlager S, Nelson K, et al. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop. 2013;144(3):471–8.CrossRef Flügge TV, Schlager S, Nelson K, et al. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop. 2013;144(3):471–8.CrossRef
9.
go back to reference Su TS, Sun J. Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: an in-vitro study. J Prosthodont Res. 2015;59(4):236–42.CrossRef Su TS, Sun J. Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: an in-vitro study. J Prosthodont Res. 2015;59(4):236–42.CrossRef
11.
go back to reference Ender A, Mehl A. Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent. 2013;16(1):11–21.PubMed Ender A, Mehl A. Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent. 2013;16(1):11–21.PubMed
15.
go back to reference Güth JF, Keul C, Stimmelmayr M, et al. Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig. 2013;17(4):1201–8.CrossRef Güth JF, Keul C, Stimmelmayr M, et al. Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig. 2013;17(4):1201–8.CrossRef
16.
go back to reference Kattadiyil MT, Mursic Z, Alrumaih H, et al. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent. 2014;112(3):444–8.CrossRef Kattadiyil MT, Mursic Z, Alrumaih H, et al. Intraoral scanning of hard and soft tissues for partial removable dental prosthesis fabrication. J Prosthet Dent. 2014;112(3):444–8.CrossRef
17.
go back to reference Londono J, Abreu A, Baker PS, et al. Fabrication of a definitive obturator from a 3D cast with achairside digital scanner for a patient with severe gag reflex: a clinical report. J Prosthet Dent. 2015;114(5):735–8.CrossRef Londono J, Abreu A, Baker PS, et al. Fabrication of a definitive obturator from a 3D cast with achairside digital scanner for a patient with severe gag reflex: a clinical report. J Prosthet Dent. 2015;114(5):735–8.CrossRef
18.
go back to reference Al MN, Jones Q, Eggbeer D, et al. Fabrication of a resin appliance with alloy components using digital technology without an analog impression. Am J Orthod Dentofacial Orthop. 2015;148(5):862–7.CrossRef Al MN, Jones Q, Eggbeer D, et al. Fabrication of a resin appliance with alloy components using digital technology without an analog impression. Am J Orthod Dentofacial Orthop. 2015;148(5):862–7.CrossRef
19.
go back to reference Graf S, Cornelis MA, Hauber GG, et al. Computer-aided design and manufacture of hyrax devices: can we really go digital? Am J Orthod Dentofacial Orthop. 2017;152(6):870–4.CrossRef Graf S, Cornelis MA, Hauber GG, et al. Computer-aided design and manufacture of hyrax devices: can we really go digital? Am J Orthod Dentofacial Orthop. 2017;152(6):870–4.CrossRef
20.
go back to reference Taneva ED, Johnson A, Viana G, et al. 3D evaluation of palatal rugae for human identification using digital study models. J Forensic Dent Sci. 2015;7(3):244–52.CrossRef Taneva ED, Johnson A, Viana G, et al. 3D evaluation of palatal rugae for human identification using digital study models. J Forensic Dent Sci. 2015;7(3):244–52.CrossRef
21.
go back to reference Chen WR, Chang YC, Best CT, et al. Super-imposing maxillary and palatal locations for electroarticulometry: a SIMPLE method. J Acoust Soc Am. 2015;138(2):161–6.CrossRef Chen WR, Chang YC, Best CT, et al. Super-imposing maxillary and palatal locations for electroarticulometry: a SIMPLE method. J Acoust Soc Am. 2015;138(2):161–6.CrossRef
22.
go back to reference Lione R, Franchi L, Huanca Ghislanzoni LT, et al. Palatal surface and volume in mouth-breathing subjects evaluated with three-dimensional analysis of digital dental casts-a controlled study. Eur J Orthod. 2015;37(1):101–4.CrossRef Lione R, Franchi L, Huanca Ghislanzoni LT, et al. Palatal surface and volume in mouth-breathing subjects evaluated with three-dimensional analysis of digital dental casts-a controlled study. Eur J Orthod. 2015;37(1):101–4.CrossRef
23.
go back to reference Choi DS, Jeong YM, Jang I, et al. Accuracy and reliability of palatal superimposition of three-dimensional digital models. Angle Orthod. 2010;80(4):497–503.PubMed Choi DS, Jeong YM, Jang I, et al. Accuracy and reliability of palatal superimposition of three-dimensional digital models. Angle Orthod. 2010;80(4):497–503.PubMed
24.
go back to reference Choi JI, Cha BK, Jostbrinkmann PG, et al. Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear. Korean J Orthod. 2012;42(5):235–41.CrossRef Choi JI, Cha BK, Jostbrinkmann PG, et al. Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear. Korean J Orthod. 2012;42(5):235–41.CrossRef
25.
go back to reference Chen G, Chen S, Zhang XY, et al. Stable region for maxillary dental cast superimposition in adults, studied with the aid of stable miniscrews. Orthod Craniofac Res. 2011;14(2):70–9.CrossRef Chen G, Chen S, Zhang XY, et al. Stable region for maxillary dental cast superimposition in adults, studied with the aid of stable miniscrews. Orthod Craniofac Res. 2011;14(2):70–9.CrossRef
26.
go back to reference Deferm JT, Schreurs R, Baan F, et al. Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning. Clin Oral Investig. 2018;22(3):1303–9.CrossRef Deferm JT, Schreurs R, Baan F, et al. Validation of 3D documentation of palatal soft tissue shape, color, and irregularity with intraoral scanning. Clin Oral Investig. 2018;22(3):1303–9.CrossRef
27.
go back to reference Martin CB, Chalmers EV, Mcintyre GT, et al. Orthodontic scanners: what's available? Br J Orthod. 2015;42(2):136–43.CrossRef Martin CB, Chalmers EV, Mcintyre GT, et al. Orthodontic scanners: what's available? Br J Orthod. 2015;42(2):136–43.CrossRef
28.
go back to reference Pavoni C, Paoloni V, Ghislanzoni LTH, et al. Geometric morphometric analysis of the palatal morphology in children with impacted incisors: a three-dimensional evaluation. Angle Orthod. 2017;87(3):404–8.CrossRef Pavoni C, Paoloni V, Ghislanzoni LTH, et al. Geometric morphometric analysis of the palatal morphology in children with impacted incisors: a three-dimensional evaluation. Angle Orthod. 2017;87(3):404–8.CrossRef
29.
go back to reference Yan-Yan NI, Zhang JX. How to determine permissible error δ value properly when computing sample sizes in hypothesis tests. J Evid Based Med. 2011;11(6):370–4. Yan-Yan NI, Zhang JX. How to determine permissible error δ value properly when computing sample sizes in hypothesis tests. J Evid Based Med. 2011;11(6):370–4.
30.
go back to reference Wesemann C, Muallah J, Mah J, et al. Accuracy and efficiency of full-arch digitalization and 3D printing: a comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing. Quintessence Int. 2017;48(1):41–50.PubMed Wesemann C, Muallah J, Mah J, et al. Accuracy and efficiency of full-arch digitalization and 3D printing: a comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing. Quintessence Int. 2017;48(1):41–50.PubMed
31.
go back to reference De WO, Rangel FA, Fudalej PS, et al. Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts. Am J Orthod Dentofac Orthop. 2014;146(3):328–36.CrossRef De WO, Rangel FA, Fudalej PS, et al. Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts. Am J Orthod Dentofac Orthop. 2014;146(3):328–36.CrossRef
32.
go back to reference Majid Z, Chong AK, Setan H. Important considerations for craniofacial mapping using laser scanners. Photogramm Rec. 2007;22(120):1–19.CrossRef Majid Z, Chong AK, Setan H. Important considerations for craniofacial mapping using laser scanners. Photogramm Rec. 2007;22(120):1–19.CrossRef
33.
go back to reference Miller L, Morris DO, Berry E. Visualizing three-dimensional facial soft tissue changes following orthognathic surgery. Eur J Orthod. 2007;29(1):14–20.CrossRef Miller L, Morris DO, Berry E. Visualizing three-dimensional facial soft tissue changes following orthognathic surgery. Eur J Orthod. 2007;29(1):14–20.CrossRef
34.
go back to reference Koo TK, Li MY. A guideline of selecting and reporting Intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155–63.CrossRef Koo TK, Li MY. A guideline of selecting and reporting Intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155–63.CrossRef
35.
go back to reference Ikuta S, Renata C, Rubira-Bullen F, et al. Position of the greater palatine foramen: an anatomical study through cone beam computed tomography images. Surg Radiol Anat. 2013;35(9):837–42.CrossRef Ikuta S, Renata C, Rubira-Bullen F, et al. Position of the greater palatine foramen: an anatomical study through cone beam computed tomography images. Surg Radiol Anat. 2013;35(9):837–42.CrossRef
Metadata
Title
Deviations in palatal region between indirect and direct digital models: an in vivo study
Authors
Yang Zhongpeng
Xu Tianmin
Jiang Ruoping
Publication date
01-12-2019
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2019
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-019-0751-3

Other articles of this Issue 1/2019

BMC Oral Health 1/2019 Go to the issue