Skip to main content
Top
Published in: International Journal of Legal Medicine 5/2011

01-09-2011 | Original Article

Development and validation of I-DNA1: a 15-Loci multiplex system for identity testing

Authors: A. Odriozola, J. M. Aznar, D. Celorrio, M. L. Bravo, J. J. Builes, J. F. Val-Bernal, Marian M. de Pancorbo

Published in: International Journal of Legal Medicine | Issue 5/2011

Login to get access

Abstract

This paper presents a system for the multiplex amplification of 15 loci, known as I-DNA1, which combines mini and midiSTR technology, with amplicon sizes ranging from 49 to 297 bp. I-DNA1 analyses all the STR loci included in the CODIS and the Interpol Standard Set of loci, nine of the ten European core loci and seven of the eight German core loci, making it suitable for use in identifying humans. Moreover, its high sensitivity and the small size of its amplicons mean that I-DNA1 is potentially highly useful for analysing highly degraded and/or very small DNA samples.
Literature
1.
go back to reference Butler JM (2007) Short tandem repeat typing technologies used in human identity testing. Biotechniques 43(4):ii–vPubMedCrossRef Butler JM (2007) Short tandem repeat typing technologies used in human identity testing. Biotechniques 43(4):ii–vPubMedCrossRef
2.
go back to reference Martin PDSH, Schneider PM (2001) A brief history of the formation of DNA databases in forensic science within Europe. Forensic Sci Int 119:225–231PubMedCrossRef Martin PDSH, Schneider PM (2001) A brief history of the formation of DNA databases in forensic science within Europe. Forensic Sci Int 119:225–231PubMedCrossRef
3.
go back to reference LS AC (2004) International perspectives on forensic DNA databases. Forensic Sci Int 146(Suppl):S119–S121 LS AC (2004) International perspectives on forensic DNA databases. Forensic Sci Int 146(Suppl):S119–S121
4.
go back to reference C-R F (2004) Forensic DNA databases. Forensic Sci Int 146(Suppl):S143–S144 C-R F (2004) Forensic DNA databases. Forensic Sci Int 146(Suppl):S143–S144
5.
go back to reference Schlenk J, Seidl S, Braunschweiger G, Betz P, Lederer T (2004) Development of a 13-locus PCR multiplex system for paternity testing. Int J Legal Med 118(1):55–61PubMedCrossRef Schlenk J, Seidl S, Braunschweiger G, Betz P, Lederer T (2004) Development of a 13-locus PCR multiplex system for paternity testing. Int J Legal Med 118(1):55–61PubMedCrossRef
6.
go back to reference Cotton EA, Allsop RF, Guest JL, Frazier RR, Koumi P, Callow IP, Seager A, Sparkes RL (2000) Validation of the AMPFISTR SGM plus system for use in forensic casework. Forensic Sci Int 112(2–3):151–161PubMedCrossRef Cotton EA, Allsop RF, Guest JL, Frazier RR, Koumi P, Callow IP, Seager A, Sparkes RL (2000) Validation of the AMPFISTR SGM plus system for use in forensic casework. Forensic Sci Int 112(2–3):151–161PubMedCrossRef
7.
go back to reference Collins PJ, Hennessy LK, Leibelt CS, Roby RK, Reeder DJ, Foxall PA (2004) Developmental validation of a single-tube amplification of the 13 CODIS STR loci, D2S1338, D19S433, and amelogenin: the AmpFISTR Identifiler PCR Amplification Kit. J Forensic Sci 49(6):1265–1277PubMedCrossRef Collins PJ, Hennessy LK, Leibelt CS, Roby RK, Reeder DJ, Foxall PA (2004) Developmental validation of a single-tube amplification of the 13 CODIS STR loci, D2S1338, D19S433, and amelogenin: the AmpFISTR Identifiler PCR Amplification Kit. J Forensic Sci 49(6):1265–1277PubMedCrossRef
8.
go back to reference Krenke BE, Tereba A, Anderson SJ, Buel E, Culhane S, Finis CJ, Tomsey CS, Zachetti JM, Masibay A, Rabbach DR, Amiott EA, Sprecher CJ (2002) Validation of a 16-locus fluorescent multiplex system. J Forensic Sci 47(4):773–785PubMed Krenke BE, Tereba A, Anderson SJ, Buel E, Culhane S, Finis CJ, Tomsey CS, Zachetti JM, Masibay A, Rabbach DR, Amiott EA, Sprecher CJ (2002) Validation of a 16-locus fluorescent multiplex system. J Forensic Sci 47(4):773–785PubMed
9.
go back to reference Coticone SR, Oldroyd N, Philips H, Foxall P (2004) Development of the AmpFISTR SEfiler PCR amplification kit: a new multiplex containing the highly discriminating ACTBP2 (SE33) locus. Int J Legal Med 118(4):224–234PubMedCrossRef Coticone SR, Oldroyd N, Philips H, Foxall P (2004) Development of the AmpFISTR SEfiler PCR amplification kit: a new multiplex containing the highly discriminating ACTBP2 (SE33) locus. Int J Legal Med 118(4):224–234PubMedCrossRef
10.
go back to reference BJ HCR, Vallone PM (2009) A 26plex autosomal STR assay to aid human identity testing. J Forensic Sci 54(5):1008–1015CrossRef BJ HCR, Vallone PM (2009) A 26plex autosomal STR assay to aid human identity testing. J Forensic Sci 54(5):1008–1015CrossRef
11.
go back to reference Wallin JM, Buoncristiani MR, Lazaruk KD, Fildes N, Holt CL, Walsh PS (1998) TWGDAM validation of the AmpFISTR blue PCR amplification kit for forensic casework analysis. J Forensic Sci 43(4):854–870PubMed Wallin JM, Buoncristiani MR, Lazaruk KD, Fildes N, Holt CL, Walsh PS (1998) TWGDAM validation of the AmpFISTR blue PCR amplification kit for forensic casework analysis. J Forensic Sci 43(4):854–870PubMed
12.
go back to reference LaFountain MJ, Schwartz MB, Svete PA, Walkinshaw MA, Buel E (2001) TWGDAM validation of the AmpFISTR Profiler Plus and AmpFISTR COfiler STR multiplex systems using capillary electrophoresis. J Forensic Sci 46(5):1191–1198PubMed LaFountain MJ, Schwartz MB, Svete PA, Walkinshaw MA, Buel E (2001) TWGDAM validation of the AmpFISTR Profiler Plus and AmpFISTR COfiler STR multiplex systems using capillary electrophoresis. J Forensic Sci 46(5):1191–1198PubMed
13.
go back to reference Grubwieser P, Mühlmann R, Berger B, Niederstätter H, Pavlic M, Parson W (2006) A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA. Int J Legal Med 120(2):115–120PubMedCrossRef Grubwieser P, Mühlmann R, Berger B, Niederstätter H, Pavlic M, Parson W (2006) A new “miniSTR-multiplex” displaying reduced amplicon lengths for the analysis of degraded DNA. Int J Legal Med 120(2):115–120PubMedCrossRef
14.
go back to reference Müller K, Klein R, Miltner E, Wiegand P (2007) Q8–a short amplicon multiplex including the German DNA database systems. Forensic Sci Int Genet 1(2):205–207PubMedCrossRef Müller K, Klein R, Miltner E, Wiegand P (2007) Q8–a short amplicon multiplex including the German DNA database systems. Forensic Sci Int Genet 1(2):205–207PubMedCrossRef
15.
go back to reference Klaus Bender PMS (2006) Validation and casework testing of the BioPlex-11 for STR typing of telogen hair roots. Forensic Sci Int 161(1):52–59PubMedCrossRef Klaus Bender PMS (2006) Validation and casework testing of the BioPlex-11 for STR typing of telogen hair roots. Forensic Sci Int 161(1):52–59PubMedCrossRef
16.
go back to reference Mulero JJ, Chang CW, Lagace RE, Wang DY, Bas JL, McMahon TP, Hennessy LK (2008) Development and validation of the AmpFISTR MiniFiler PCR Amplification Kit: a MiniSTR multiplex for the analysis of degraded and/or PCR inhibited DNA. J Forensic Sci 53(4):838–852PubMedCrossRef Mulero JJ, Chang CW, Lagace RE, Wang DY, Bas JL, McMahon TP, Hennessy LK (2008) Development and validation of the AmpFISTR MiniFiler PCR Amplification Kit: a MiniSTR multiplex for the analysis of degraded and/or PCR inhibited DNA. J Forensic Sci 53(4):838–852PubMedCrossRef
17.
go back to reference Müller K, Klein R, Miltner E, Wiegand P (2007) Improved STR typing of telogen hair root and hair shaft DNA. Electrophoresis 28(16):2835–2842PubMedCrossRef Müller K, Klein R, Miltner E, Wiegand P (2007) Improved STR typing of telogen hair root and hair shaft DNA. Electrophoresis 28(16):2835–2842PubMedCrossRef
18.
go back to reference Butler JM, Shen Y, McCord BR (2003) The development of reduced size STR amplicons as tools for analysis of degraded DNA. J Forensic Sci 48(5):1054–1064PubMed Butler JM, Shen Y, McCord BR (2003) The development of reduced size STR amplicons as tools for analysis of degraded DNA. J Forensic Sci 48(5):1054–1064PubMed
19.
go back to reference Coble MD, Butler JM (2005) Characterization of new miniSTR loci to aid analysis of degraded DNA. J Forensic Sci 50(1):43–53PubMedCrossRef Coble MD, Butler JM (2005) Characterization of new miniSTR loci to aid analysis of degraded DNA. J Forensic Sci 50(1):43–53PubMedCrossRef
20.
go back to reference Wiegand P, Kleiber M (2001) Less is more–length reduction of STR amplicons using redesigned primers. Int J Legal Med 114(4–5):285–287PubMedCrossRef Wiegand P, Kleiber M (2001) Less is more–length reduction of STR amplicons using redesigned primers. Int J Legal Med 114(4–5):285–287PubMedCrossRef
21.
go back to reference Ellegren H (2004) Microsatellites: simple sequences with complex evolution. Nat Rev Genet 5(6):435–445PubMedCrossRef Ellegren H (2004) Microsatellites: simple sequences with complex evolution. Nat Rev Genet 5(6):435–445PubMedCrossRef
22.
go back to reference Miller SA, Dykes DD, Polesky HF (1988) A simple salting out procedure for extracting DNA from human nucleated cells. Nucl Acids Res 16:1215PubMedCrossRef Miller SA, Dykes DD, Polesky HF (1988) A simple salting out procedure for extracting DNA from human nucleated cells. Nucl Acids Res 16:1215PubMedCrossRef
23.
go back to reference Ruitberg CM, Reeder DJ, Butler JM (2001) STRBase: a short tandem repeat DNA database for the human identity testing community. Nucleic Acids Res 29(1):320–322PubMedCrossRef Ruitberg CM, Reeder DJ, Butler JM (2001) STRBase: a short tandem repeat DNA database for the human identity testing community. Nucleic Acids Res 29(1):320–322PubMedCrossRef
24.
go back to reference Brownstein MJ, Carpten JD, Smith JR (1996) Modulation of non-templated nucleotide addition by Taq DNA polymerase: primer modifications that facilitate genotyping. Biotechniques 20(6):1004–1006, 1008-1010PubMed Brownstein MJ, Carpten JD, Smith JR (1996) Modulation of non-templated nucleotide addition by Taq DNA polymerase: primer modifications that facilitate genotyping. Biotechniques 20(6):1004–1006, 1008-1010PubMed
25.
go back to reference Farrugia A, Keyser C, Ludes B (2010) Efficiency evaluation of a DNA extraction and purification protocol on archival formalin-fixed and paraffin-embedded tissue. Forensic Sci Int 194(1–3):e25–e28PubMedCrossRef Farrugia A, Keyser C, Ludes B (2010) Efficiency evaluation of a DNA extraction and purification protocol on archival formalin-fixed and paraffin-embedded tissue. Forensic Sci Int 194(1–3):e25–e28PubMedCrossRef
26.
go back to reference Tagliaro F, Pascali J, Fanigliulo A, Bortolotti F (2010) Recent advances in the application of CE to forensic sciences: a update over years 2007–2009. Electrophoresis 31(1):251–259PubMedCrossRef Tagliaro F, Pascali J, Fanigliulo A, Bortolotti F (2010) Recent advances in the application of CE to forensic sciences: a update over years 2007–2009. Electrophoresis 31(1):251–259PubMedCrossRef
27.
go back to reference Shinka T, Naroda T, Tamura T, Sasahara K, Nakahori Y (2001) A rapid and simple method for sex identification by heteroduplex analysis, using denaturing high-performance liquid chromatography (DHPLC). J Hum Genet 46(5):263–266PubMedCrossRef Shinka T, Naroda T, Tamura T, Sasahara K, Nakahori Y (2001) A rapid and simple method for sex identification by heteroduplex analysis, using denaturing high-performance liquid chromatography (DHPLC). J Hum Genet 46(5):263–266PubMedCrossRef
28.
go back to reference Devaney JM, Girard JE, Marino MA (2000) DNA microsatellite analysis using ion-pair reversed-phase high-performance liquid chromatography. Anal Chem 72(4):858–864PubMedCrossRef Devaney JM, Girard JE, Marino MA (2000) DNA microsatellite analysis using ion-pair reversed-phase high-performance liquid chromatography. Anal Chem 72(4):858–864PubMedCrossRef
29.
go back to reference Hill CR, Kline MC, Mulero JJ, Lagace RE, Chang CW, Hennessy LK, Butler JM (2007) Concordance study between the AmpFISTR MiniFiler PCR amplification kit and conventional STR typing kits. J Forensic Sci 52(4):870–873PubMedCrossRef Hill CR, Kline MC, Mulero JJ, Lagace RE, Chang CW, Hennessy LK, Butler JM (2007) Concordance study between the AmpFISTR MiniFiler PCR amplification kit and conventional STR typing kits. J Forensic Sci 52(4):870–873PubMedCrossRef
30.
go back to reference Budowle B, Aranda XG, Lagace RE, Hennessy LK, Planz JV, Rodriguez M, Eisenberg AJ (2008) Null allele sequence structure at the DYS448 locus and implications for profile interpretation. Int J Legal Med 122(5):421–427PubMedCrossRef Budowle B, Aranda XG, Lagace RE, Hennessy LK, Planz JV, Rodriguez M, Eisenberg AJ (2008) Null allele sequence structure at the DYS448 locus and implications for profile interpretation. Int J Legal Med 122(5):421–427PubMedCrossRef
31.
go back to reference Zhai XD, Xue XQ, Mo YN, Zhao GS, Ai HW, Ye Y, Wang Z, Hou YP (2010) False homozygosities at CSF1PO loci revealed by discrepancies between two kits in Chinese population. Int J Legal Med 124(5):457–458PubMedCrossRef Zhai XD, Xue XQ, Mo YN, Zhao GS, Ai HW, Ye Y, Wang Z, Hou YP (2010) False homozygosities at CSF1PO loci revealed by discrepancies between two kits in Chinese population. Int J Legal Med 124(5):457–458PubMedCrossRef
32.
go back to reference Budowle B, Eisenberg AJ, van Daal A (2009) Validity of low copy number typing and applications to forensic science. Croat Med J 50(3):207–217PubMedCrossRef Budowle B, Eisenberg AJ, van Daal A (2009) Validity of low copy number typing and applications to forensic science. Croat Med J 50(3):207–217PubMedCrossRef
33.
go back to reference Walsh PS, Fildes NJ, Reynolds R (1996) Sequence analysis and characterization of stutter products at the tetranucleotide repeat locus vWA. Nucleic Acids Res 24(14):2807–2812PubMedCrossRef Walsh PS, Fildes NJ, Reynolds R (1996) Sequence analysis and characterization of stutter products at the tetranucleotide repeat locus vWA. Nucleic Acids Res 24(14):2807–2812PubMedCrossRef
34.
go back to reference Sullivan KM, Mannucci A, Kimpton CP, Gill P (1993) A rapid and quantitative DNA sex test: fluorescence-based PCR analysis of X-Y homologous gene amelogenin. Biotechniques 15(4):636–638, 640–631 Sullivan KM, Mannucci A, Kimpton CP, Gill P (1993) A rapid and quantitative DNA sex test: fluorescence-based PCR analysis of X-Y homologous gene amelogenin. Biotechniques 15(4):636–638, 640–631
Metadata
Title
Development and validation of I-DNA1: a 15-Loci multiplex system for identity testing
Authors
A. Odriozola
J. M. Aznar
D. Celorrio
M. L. Bravo
J. J. Builes
J. F. Val-Bernal
Marian M. de Pancorbo
Publication date
01-09-2011
Publisher
Springer-Verlag
Published in
International Journal of Legal Medicine / Issue 5/2011
Print ISSN: 0937-9827
Electronic ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-010-0539-0

Other articles of this Issue 5/2011

International Journal of Legal Medicine 5/2011 Go to the issue