Abstract

Purpose

The purpose is to evaluate the interdevice and interobserver agreements between the SL SCAN-1 (a FD-OCT integrated into a common slit lamp) and a standard stand-alone FD-OCT device (the Cirrus) with regard to the presence or absence of signs of leakage in the retina in patients with exudative AMD and treated with anti-VEGF.

Methods

Fifty-six patients, known to have exudative AMD and under treatment with anti-VEGF agents, were included. During a regular follow-up, OCT scans were made with the Cirrus (macular-cube pattern) and the SL SCAN-1 (radial-scan pattern). All scans were graded by two medical retina specialists for signs of intraretinal cysts, subretinal fluid accumulation, and thickening of the neurosensory retina. Presence of signs of leakage was concluded if one or more of the three signs were present.

Results

In 91 % of the patients, the observers made identical conclusions for both devices of the presence of signs of leakage, resulting in an interdevice Kappa coefficient of 0.87. For the scans with disagreement about the presence or absence of signs of leakage, positive and negative conclusions were equally distributed between both devices, and differences were restricted to more subtle signs of leakage.

Conclusion

The interdevice Kappa coefficient of 0.87 shows a high agreement between the SL SCAN-1 and the Cirrus in grading signs of leakage in exudative AMD. OCT images play a pivotal role in the diagnosis and management of exudative diseases like AMD, and the SL SCAN-1 provides a very efficient approach to these patients with the integration of the FD-OCT device into a common slit lamp.
Literature
1.
go back to reference Stehouwer M, Verbraak FD, de Vries H, Kok PH, van Leeuwen TG (2010) Fourier Domain Optical Coherence Tomography integrated into a slit lamp; a novel technique combining anterior and posterior segment OCT. Eye (Lond) 24:980–984CrossRef Stehouwer M, Verbraak FD, de Vries H, Kok PH, van Leeuwen TG (2010) Fourier Domain Optical Coherence Tomography integrated into a slit lamp; a novel technique combining anterior and posterior segment OCT. Eye (Lond) 24:980–984CrossRef
2.
go back to reference Stehouwer M, Tan SH, van Leeuwen TG, Verbraak FD (2014) Senile retinoschisis versus retinal detachment, the additional value of peripheral retinal OCT scans (SL SCAN-1, Topcon). Acta Ophthalmol 92(3):221–7PubMedCrossRef Stehouwer M, Tan SH, van Leeuwen TG, Verbraak FD (2014) Senile retinoschisis versus retinal detachment, the additional value of peripheral retinal OCT scans (SL SCAN-1, Topcon). Acta Ophthalmol 92(3):221–7PubMedCrossRef
4.
go back to reference Giani A, Cigada M, Esmaili DD, Salvetti P, Luccarelli S, Marziani E, Luiselli C, Sabella P, Cereda M, Eandi C, Staurenghi G (2010) Artifacts in automatic retinal segmentation using different optical coherence tomography instruments. Retina 30:607–616PubMedCrossRef Giani A, Cigada M, Esmaili DD, Salvetti P, Luccarelli S, Marziani E, Luiselli C, Sabella P, Cereda M, Eandi C, Staurenghi G (2010) Artifacts in automatic retinal segmentation using different optical coherence tomography instruments. Retina 30:607–616PubMedCrossRef
5.
go back to reference Song Y, Lee BR, Shin YW, Lee YJ (2012) Overcoming segmentation errors in measurements of macular thickness made by spectral-domain optical coherence tomography. Retina 32:569–580PubMedCrossRef Song Y, Lee BR, Shin YW, Lee YJ (2012) Overcoming segmentation errors in measurements of macular thickness made by spectral-domain optical coherence tomography. Retina 32:569–580PubMedCrossRef
6.
go back to reference Sayanagi K, Sharma S, Kaiser PK (2009) Comparison of retinal thickness measurements between three-dimensional and radial scans on spectral-domain optical coherence tomography. Am J Ophthalmol 148:431–438PubMedCrossRef Sayanagi K, Sharma S, Kaiser PK (2009) Comparison of retinal thickness measurements between three-dimensional and radial scans on spectral-domain optical coherence tomography. Am J Ophthalmol 148:431–438PubMedCrossRef
7.
go back to reference Cukras C, Wang YD, Meyerle CB, Forooghian F, Chew EY, Wong WT (2010) Optical coherence tomography-based decision making in exudative age-related macular degeneration: comparison of time- vs spectral-domain devices. Eye (Lond) 24:775–783CrossRef Cukras C, Wang YD, Meyerle CB, Forooghian F, Chew EY, Wong WT (2010) Optical coherence tomography-based decision making in exudative age-related macular degeneration: comparison of time- vs spectral-domain devices. Eye (Lond) 24:775–783CrossRef
8.
go back to reference Knecht PB, Kordic H, Kurz-Levin M, Sturm V, Menke MN (2013) Inter-observer agreement for spectral- and time-domain optical coherence tomography image grading: a prospective study. Int Ophthalmol 33:47–52PubMedCrossRef Knecht PB, Kordic H, Kurz-Levin M, Sturm V, Menke MN (2013) Inter-observer agreement for spectral- and time-domain optical coherence tomography image grading: a prospective study. Int Ophthalmol 33:47–52PubMedCrossRef
9.
go back to reference Patel PJ, Browning AC, Chen FK, Da CL, Tufail A (2009) Interobserver agreement for the detection of optical coherence tomography features of neovascular age-related macular degeneration. Invest Ophthalmol Vis Sci 50:5405–5410PubMedCrossRef Patel PJ, Browning AC, Chen FK, Da CL, Tufail A (2009) Interobserver agreement for the detection of optical coherence tomography features of neovascular age-related macular degeneration. Invest Ophthalmol Vis Sci 50:5405–5410PubMedCrossRef
Metadata
Title
Detecting signs of retinal leakage in exudative AMD using Cirrus OCT versus SL SCAN-1, a novel integrated FD-OCT into a common slit lamp
Authors
M. Stehouwer
F. D. Verbraak
R. O. Schlingemann
T. G. van Leeuwen
Publication date
01-01-2016
Publisher
Springer Berlin Heidelberg
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 1/2016
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-015-2997-z

Other articles of this Issue 1/2016

Graefe's Archive for Clinical and Experimental Ophthalmology 1/2016 Go to the issue