Skip to main content
Top
Published in: Clinical Oral Investigations 3/2020

01-03-2020 | Cytokines | Original Article

Mapping of inflammatory biomarkers in the peri-implant crevicular fluid before and after the occlusal loading of narrow diameter implants

Authors: Raissa Micaella Marcello-Machado, Fernanda Faot, Alessandra Julie Schuster, Amália Machado Bielemann, Gustavo Giacomelli Nascimento, Altair Antoninha Del Bel Cury

Published in: Clinical Oral Investigations | Issue 3/2020

Login to get access

Abstract

Objective

To monitor the cytokine release patterns in the peri-implant crevicular fluid (PICF) and to investigate which factors affect the success rate of narrow diameter implants (NDI) during the first year.

Material and methods

Mandibular implant overdentures (IOD) retained by 2 NDI were installed in 16 clinically atrophic edentulous patients. The following parameters were monitored during the first year: (i) peri-implant health parameters (plaque index (PI), calculus presence (CP), gingival index (GI), probing depth (PD) and bleeding on probing (BoP); (ii) cytokine concentrations in the PICF (TNF-α, IL-1β, IL-6, IL-10); (iii) implant stability quotient (ISQ); (iv) marginal bone level (MBL) and bone level change (BLC); (v) implant success. The insertion torque, bone type, mandibular atrophy, time since edentulism, and smoking habits were also recorded. All data were analyzed using multivariable multilevel mixed-effects regression models.

Results

The variability in the TNF-α release patterns temporarily reduced at weeks (w) 8–12, while the IL-1β concentrations remained low until they peaked at w48 [p < 0.05; + 177.55 pg/μl (+ 96.13 − + 258.97)]. Conversely, IL-10 release decreased significantly at w48 [p < 0.05; − 456.24 pg/μl (− 644.41 − − 268.07)]. The PD and ISQ decreased significantly (p < 0.05) over the follow-up period, while the MBL was stable after w48 with a BLC of 0.12 ± 0.71 mm. The overall success rate was 81.3%, and was influenced by TNF-α, IL-1β, IL-10, PI, GI, PD, smoking, and time since edentulism.

Conclusion

Pro- and anti-inflammatory cytokine release was balanced during the first 24 weeks. The GI, smoking, and time since edentulism are the most important factors determining the implant success.

Clinical relevance

The study contributes to the understanding of the osseointegration process in a clinically atrophic population rehabilitated with IOD, and highlights the importance of monitoring clinical peri-implant health-related parameters, smoking habit, and time since edentulism to predict implant success rates.
Appendix
Available only for authorised users
Literature
1.
go back to reference Klein MO, Schiegnitz E, Al-Nawas B (2014) Systematic review on success of narrow-diameter dental implants. Int J Oral Maxillofac Implants 29 Suppl:43–54CrossRefPubMed Klein MO, Schiegnitz E, Al-Nawas B (2014) Systematic review on success of narrow-diameter dental implants. Int J Oral Maxillofac Implants 29 Suppl:43–54CrossRefPubMed
2.
go back to reference Al-Johany SS, Al Amri MD, Alsaeed S, Alalola B (2017) Dental implant length and diameter: a proposed classification scheme. J Prosthodont 26:252–260CrossRefPubMed Al-Johany SS, Al Amri MD, Alsaeed S, Alalola B (2017) Dental implant length and diameter: a proposed classification scheme. J Prosthodont 26:252–260CrossRefPubMed
3.
go back to reference Schiegnitz E, Al-Nawas B (2018) Narrow-diameter implants: a systematic review and meta-analysis. Clin Oral Implants Res 29:21–40CrossRefPubMed Schiegnitz E, Al-Nawas B (2018) Narrow-diameter implants: a systematic review and meta-analysis. Clin Oral Implants Res 29:21–40CrossRefPubMed
4.
go back to reference El-Sheikh AM, Shihabuddin OF, Ghoraba SMF (2012) Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study. Int J Dent 2012:285684PubMedPubMedCentral El-Sheikh AM, Shihabuddin OF, Ghoraba SMF (2012) Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study. Int J Dent 2012:285684PubMedPubMedCentral
5.
go back to reference Degidi M, Piattelli A, Carinci F (2008) Clinical outcome of narrow diameter implants: a retrospective study of 510 implants. J Periodontol 79:49–54CrossRefPubMed Degidi M, Piattelli A, Carinci F (2008) Clinical outcome of narrow diameter implants: a retrospective study of 510 implants. J Periodontol 79:49–54CrossRefPubMed
6.
go back to reference Allum SR, Tomlinson RA, Joshi R (2008) The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res 19:553–559CrossRefPubMed Allum SR, Tomlinson RA, Joshi R (2008) The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res 19:553–559CrossRefPubMed
7.
go back to reference Lee JH, Frias V, Lee KW, Wright RF (2005) Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 94:377–381CrossRefPubMed Lee JH, Frias V, Lee KW, Wright RF (2005) Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 94:377–381CrossRefPubMed
8.
go back to reference Bidra AS, Almas K (2013) Mini implants for definitive prosthodontic treatment: a systematic review. J Prosthet Dent 109:156–164CrossRefPubMed Bidra AS, Almas K (2013) Mini implants for definitive prosthodontic treatment: a systematic review. J Prosthet Dent 109:156–164CrossRefPubMed
9.
go back to reference Pan S, Dagenais M, Thomason JM, Awad M, Emami E, Kimoto S, Wollin SD, Feine JS (2010) Does mandibular edentulous bone height affect prosthetic treatment success? J Dent 38:899–907CrossRefPubMed Pan S, Dagenais M, Thomason JM, Awad M, Emami E, Kimoto S, Wollin SD, Feine JS (2010) Does mandibular edentulous bone height affect prosthetic treatment success? J Dent 38:899–907CrossRefPubMed
10.
go back to reference Marcello-Machado RM, Bielemann AM, Nascimento GG, Pinto LR, del Bel Cury AA, Faot F (2017) Masticatory function parameters in patients with varying degree of mandibular bone resorption. J Prosthodont Res 61:315–323CrossRefPubMed Marcello-Machado RM, Bielemann AM, Nascimento GG, Pinto LR, del Bel Cury AA, Faot F (2017) Masticatory function parameters in patients with varying degree of mandibular bone resorption. J Prosthodont Res 61:315–323CrossRefPubMed
11.
go back to reference Marcello-Machado RM, Faot F, Schuster AJ, Bielemann AM, Chagas Júnior OL, del Bel Cury AA (2017) How does mandibular bone atrophy influence the masticatory function, OHRQoL and satisfaction in overdenture wearers? Clinical results until 1-year post-loading. J Oral Rehabil 44:850–859CrossRefPubMed Marcello-Machado RM, Faot F, Schuster AJ, Bielemann AM, Chagas Júnior OL, del Bel Cury AA (2017) How does mandibular bone atrophy influence the masticatory function, OHRQoL and satisfaction in overdenture wearers? Clinical results until 1-year post-loading. J Oral Rehabil 44:850–859CrossRefPubMed
12.
go back to reference Buser D, von Arx T (2000) Surgical procedures in partially edentulous patients with ITI implants. Clin Oral Implants Res 11(Suppl 1):83–100CrossRefPubMed Buser D, von Arx T (2000) Surgical procedures in partially edentulous patients with ITI implants. Clin Oral Implants Res 11(Suppl 1):83–100CrossRefPubMed
13.
go back to reference Akça K, Cehreli MC, Iplikçioğlu H (2003) Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis. Clin Oral Implants Res 14:444–454CrossRefPubMed Akça K, Cehreli MC, Iplikçioğlu H (2003) Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis. Clin Oral Implants Res 14:444–454CrossRefPubMed
14.
go back to reference Albrektsson T, Johansson C (2001) Osteoinduction, osteoconduction and osseointegration. Eur Spine J 10(Suppl 2):S96–S101 Albrektsson T, Johansson C (2001) Osteoinduction, osteoconduction and osseointegration. Eur Spine J 10(Suppl 2):S96–S101
15.
go back to reference Trindade R, Albrektsson T, Wennerberg A (2015) Current concepts for the biological basis of dental implants: foreign body equilibrium and osseointegration dynamics. Oral Maxillofac Surg Clin North Am 27:175–183CrossRefPubMed Trindade R, Albrektsson T, Wennerberg A (2015) Current concepts for the biological basis of dental implants: foreign body equilibrium and osseointegration dynamics. Oral Maxillofac Surg Clin North Am 27:175–183CrossRefPubMed
16.
go back to reference Bielemann AM, Marcello-Machado RM, Del Bel Cury AA, Faot F (2018) Systematic review of wound healing biomarkers in peri-implant crevicular fluid during osseointegration. Arch Oral Biol 89:107–128CrossRefPubMed Bielemann AM, Marcello-Machado RM, Del Bel Cury AA, Faot F (2018) Systematic review of wound healing biomarkers in peri-implant crevicular fluid during osseointegration. Arch Oral Biol 89:107–128CrossRefPubMed
17.
go back to reference Bielemann AM, Marcello-Machado RM, Leite FRM, Martinho FC, Chagas-Júnior OL, Antoninha del Bel Cury A, Faot F (2018) Comparison between inflammation-related markers in peri-implant crevicular fluid and clinical parameters during osseointegration in edentulous jaws. Clin Oral Investig 22:531–543CrossRefPubMed Bielemann AM, Marcello-Machado RM, Leite FRM, Martinho FC, Chagas-Júnior OL, Antoninha del Bel Cury A, Faot F (2018) Comparison between inflammation-related markers in peri-implant crevicular fluid and clinical parameters during osseointegration in edentulous jaws. Clin Oral Investig 22:531–543CrossRefPubMed
18.
go back to reference Pivodovaa V, Frankovaa J, Ulrichovaa J (2011) Osteoblast and gingival fibroblast markers in dental implant studies. Biomed Pap 155:109–116CrossRef Pivodovaa V, Frankovaa J, Ulrichovaa J (2011) Osteoblast and gingival fibroblast markers in dental implant studies. Biomed Pap 155:109–116CrossRef
19.
go back to reference Liskmann S, Vihalemm T, Salum O et al (2005) Correlations between clinical parameters and interleukin-6 and interleukin-10 levels in saliva from totally edentulous patients with peri-implant disease. Int J Oral Maxillofac Implants 21:543–550 Liskmann S, Vihalemm T, Salum O et al (2005) Correlations between clinical parameters and interleukin-6 and interleukin-10 levels in saliva from totally edentulous patients with peri-implant disease. Int J Oral Maxillofac Implants 21:543–550
20.
go back to reference Bastuji-Garin S, Sbidian E, Gaudy-Marqueste C et al (2013) Impact of STROBE statement publication on quality of observational study reporting: interrupted time series versus before-after analysis. PLoS One 8:2–9CrossRef Bastuji-Garin S, Sbidian E, Gaudy-Marqueste C et al (2013) Impact of STROBE statement publication on quality of observational study reporting: interrupted time series versus before-after analysis. PLoS One 8:2–9CrossRef
21.
22.
go back to reference Molly L (2006) Bone density and primary stability in implant therapy. Clin Oral Implants Res 17(Suppl 2):124–135CrossRefPubMed Molly L (2006) Bone density and primary stability in implant therapy. Clin Oral Implants Res 17(Suppl 2):124–135CrossRefPubMed
23.
go back to reference Cawood JI, Howell RA (1988) A classification of the edentulous jaws. Int J Oral Maxillofac Surg 17:232–236CrossRefPubMed Cawood JI, Howell RA (1988) A classification of the edentulous jaws. Int J Oral Maxillofac Surg 17:232–236CrossRefPubMed
24.
go back to reference Mombelli A, van Oosten MA, Schurch E, Land NP (1987) The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 2:145–151CrossRefPubMed Mombelli A, van Oosten MA, Schurch E, Land NP (1987) The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 2:145–151CrossRefPubMed
25.
go back to reference Guljé F, Raghoebar GM, Ter Meulen JWP et al (2012) Mandibular overdentures supported by 6-mm dental implants: a 1-year prospective cohort study. Clin Implant Dent Relat Res 14:59–66CrossRef Guljé F, Raghoebar GM, Ter Meulen JWP et al (2012) Mandibular overdentures supported by 6-mm dental implants: a 1-year prospective cohort study. Clin Implant Dent Relat Res 14:59–66CrossRef
26.
go back to reference Marcello-Machado RM, Faot F, Schuster AJ, Bielemann AM, Chagas Júnior OL, del Bel Cury AA (2018) One-year clinical outcomes of locking taper Equator attachments retaining mandibular overdentures to narrow diameter implants. Clin Implant Dent Relat Res 20:483–492CrossRefPubMed Marcello-Machado RM, Faot F, Schuster AJ, Bielemann AM, Chagas Júnior OL, del Bel Cury AA (2018) One-year clinical outcomes of locking taper Equator attachments retaining mandibular overdentures to narrow diameter implants. Clin Implant Dent Relat Res 20:483–492CrossRefPubMed
27.
go back to reference Al-Nawas B, Brägger U, Meijer HJA et al (2012) A double-blind randomized controlled trial (RCT) of titanium-13Zirconium versus titanium grade IV small-diameter bone level implants in edentulous mandibles - results from a 1-year observation period. Clin Implant Dent Relat Res 14:896–904CrossRefPubMed Al-Nawas B, Brägger U, Meijer HJA et al (2012) A double-blind randomized controlled trial (RCT) of titanium-13Zirconium versus titanium grade IV small-diameter bone level implants in edentulous mandibles - results from a 1-year observation period. Clin Implant Dent Relat Res 14:896–904CrossRefPubMed
28.
go back to reference Quirynen M, Al-Nawas B, Meijer HJA et al (2015) Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controlled trial. Clin Oral Implants Res 26:831–840CrossRefPubMed Quirynen M, Al-Nawas B, Meijer HJA et al (2015) Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controlled trial. Clin Oral Implants Res 26:831–840CrossRefPubMed
29.
go back to reference Misch CE, Perel ML, Wang HL, Sammartino G, Galindo-Moreno P, Trisi P, Steigmann M, Rebaudi A, Palti A, Pikos MA, Schwartz-Arad D, Choukroun J, Gutierrez-Perez JL, Marenzi G, Valavanis DK (2008) Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference. Implant Dent 17:5–15CrossRefPubMed Misch CE, Perel ML, Wang HL, Sammartino G, Galindo-Moreno P, Trisi P, Steigmann M, Rebaudi A, Palti A, Pikos MA, Schwartz-Arad D, Choukroun J, Gutierrez-Perez JL, Marenzi G, Valavanis DK (2008) Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference. Implant Dent 17:5–15CrossRefPubMed
30.
go back to reference Graves DT, Cochran D (2003) The contribution of interleukin-1 and tumor necrosis factor to periodontal tissue destruction. J Periodontol 74:391–401CrossRefPubMed Graves DT, Cochran D (2003) The contribution of interleukin-1 and tumor necrosis factor to periodontal tissue destruction. J Periodontol 74:391–401CrossRefPubMed
31.
go back to reference Petković AB, Matić SM, Stamatović NV, Vojvodić DV, Todorović TM, Lazić ZR, Kozomara RJ (2010) Proinflammatory cytokines (IL-1beta and TNF-alpha) and chemokines (IL-8 and MIP-1alpha) as markers of peri-implant tissue condition. Int J Oral Maxillofac Surg 39:478–485CrossRefPubMed Petković AB, Matić SM, Stamatović NV, Vojvodić DV, Todorović TM, Lazić ZR, Kozomara RJ (2010) Proinflammatory cytokines (IL-1beta and TNF-alpha) and chemokines (IL-8 and MIP-1alpha) as markers of peri-implant tissue condition. Int J Oral Maxillofac Surg 39:478–485CrossRefPubMed
32.
go back to reference Wei L, Sun Y, Kong X-F, Zhang C, Yue T, Zhu Q, He DY, Jiang LD (2016) The effects of dopamine receptor 2 expression on B cells on bone metabolism and TNF-α levels in rheumatoid arthritis. BMC Musculoskelet Disord 17:352CrossRefPubMedPubMedCentral Wei L, Sun Y, Kong X-F, Zhang C, Yue T, Zhu Q, He DY, Jiang LD (2016) The effects of dopamine receptor 2 expression on B cells on bone metabolism and TNF-α levels in rheumatoid arthritis. BMC Musculoskelet Disord 17:352CrossRefPubMedPubMedCentral
33.
go back to reference Slotte C, Lennerås M, Göthberg C, Suska F, Zoric N, Thomsen P, Nannmark U (2012) Gene expression of inflammation and bone healing in peri-implant crevicular fluid after placement and loading of dental implants. A kinetic clinical pilot study using quantitative real-time PCR. Clin Implant Dent Relat Res 14:723–736CrossRefPubMed Slotte C, Lennerås M, Göthberg C, Suska F, Zoric N, Thomsen P, Nannmark U (2012) Gene expression of inflammation and bone healing in peri-implant crevicular fluid after placement and loading of dental implants. A kinetic clinical pilot study using quantitative real-time PCR. Clin Implant Dent Relat Res 14:723–736CrossRefPubMed
34.
go back to reference Emecen-Huja P, Eubank TD, Shapiro V, Yildiz V, Tatakis DN, Leblebicioglu B (2013) Peri-implant versus periodontal wound healing. J Clin Periodontol 40:816–824CrossRefPubMedPubMedCentral Emecen-Huja P, Eubank TD, Shapiro V, Yildiz V, Tatakis DN, Leblebicioglu B (2013) Peri-implant versus periodontal wound healing. J Clin Periodontol 40:816–824CrossRefPubMedPubMedCentral
35.
go back to reference Gurol C, Kazazoglu E, Dabakoglu B, Korachi M (2011) A comparative study of the role of cytokine polymorphisms interleukin-10 and tumor necrosis factor alpha in susceptibility to implant failure and chronic periodontitis. Int J Oral Maxillofac Implants 26:955–960PubMed Gurol C, Kazazoglu E, Dabakoglu B, Korachi M (2011) A comparative study of the role of cytokine polymorphisms interleukin-10 and tumor necrosis factor alpha in susceptibility to implant failure and chronic periodontitis. Int J Oral Maxillofac Implants 26:955–960PubMed
36.
go back to reference Faot F, Nascimento GG, Bielemann AM, Campão TD, Leite FRM, Quirynen M (2015) Can peri-implant crevicular fluid assist in the diagnosis of peri-implantitis? A systematic review and meta-analysis. J Periodontol 86:631–645CrossRefPubMed Faot F, Nascimento GG, Bielemann AM, Campão TD, Leite FRM, Quirynen M (2015) Can peri-implant crevicular fluid assist in the diagnosis of peri-implantitis? A systematic review and meta-analysis. J Periodontol 86:631–645CrossRefPubMed
37.
go back to reference Duarte PM, Serrão CR, Miranda TS, Zanatta LCS, Bastos MF, Faveri M, Figueiredo LC, Feres M (2016) Could cytokine levels in the peri-implant crevicular fluid be used to distinguish between healthy implants and implants with peri-implantitis? A systematic review. J Periodontal Res 51:689–698CrossRefPubMed Duarte PM, Serrão CR, Miranda TS, Zanatta LCS, Bastos MF, Faveri M, Figueiredo LC, Feres M (2016) Could cytokine levels in the peri-implant crevicular fluid be used to distinguish between healthy implants and implants with peri-implantitis? A systematic review. J Periodontal Res 51:689–698CrossRefPubMed
39.
go back to reference Khoury SB, Thomas L, Walters JD, Sheridan JF, Leblebicioglu B (2008) Early wound healing following one-stage dental implant placement with and without antibiotic prophylaxis: a pilot study. J Periodontol 79:1904–1912CrossRefPubMedPubMedCentral Khoury SB, Thomas L, Walters JD, Sheridan JF, Leblebicioglu B (2008) Early wound healing following one-stage dental implant placement with and without antibiotic prophylaxis: a pilot study. J Periodontol 79:1904–1912CrossRefPubMedPubMedCentral
40.
go back to reference Schierano G, Bassi F, Gassino G, Mareschi K, Bellone G, Preti G (2000) Cytokine production and bone remodeling in patients wearing overdentures on oral implants. J Dent Res 79:1675–1682CrossRefPubMed Schierano G, Bassi F, Gassino G, Mareschi K, Bellone G, Preti G (2000) Cytokine production and bone remodeling in patients wearing overdentures on oral implants. J Dent Res 79:1675–1682CrossRefPubMed
41.
go back to reference Jawa RS, Anillo S, Huntoon K, Baumann H, Kulaylat M (2011) Analytic review: interleukin-6 in surgery, trauma, and critical care: part I: basic science. J Intensive Care Med 26:3–12CrossRefPubMedPubMedCentral Jawa RS, Anillo S, Huntoon K, Baumann H, Kulaylat M (2011) Analytic review: interleukin-6 in surgery, trauma, and critical care: part I: basic science. J Intensive Care Med 26:3–12CrossRefPubMedPubMedCentral
42.
go back to reference Jawa RS, Anillo S, Huntoon K, Baumann H, Kulaylat M (2011) Interleukin-6 in surgery, trauma, and critical care part II: clinical implications. J Intensive Care Med 26:73–87CrossRefPubMedPubMedCentral Jawa RS, Anillo S, Huntoon K, Baumann H, Kulaylat M (2011) Interleukin-6 in surgery, trauma, and critical care part II: clinical implications. J Intensive Care Med 26:73–87CrossRefPubMedPubMedCentral
44.
go back to reference Davies JE (2003) Understanding peri-implant endosseous healing. J Dent Educ 67:932–949PubMed Davies JE (2003) Understanding peri-implant endosseous healing. J Dent Educ 67:932–949PubMed
45.
go back to reference Sayardoust S, Omar O, Norderyd O, Thomsen P (2017) Clinical, radiological, and gene expression analyses in smokers and non-smokers, part 2: RCT on the late healing phase of osseointegration. Clin Implant Dent Relat Res 19:901–915CrossRefPubMed Sayardoust S, Omar O, Norderyd O, Thomsen P (2017) Clinical, radiological, and gene expression analyses in smokers and non-smokers, part 2: RCT on the late healing phase of osseointegration. Clin Implant Dent Relat Res 19:901–915CrossRefPubMed
46.
go back to reference Sasaki H, Hou L, Belani A, Wang CY, Uchiyama T, Müller R, Stashenko P (2000) IL-10, but not IL-4, suppresses infection-stimulated bone resorption in vivo. J Immunol 165:3626–3630CrossRefPubMed Sasaki H, Hou L, Belani A, Wang CY, Uchiyama T, Müller R, Stashenko P (2000) IL-10, but not IL-4, suppresses infection-stimulated bone resorption in vivo. J Immunol 165:3626–3630CrossRefPubMed
47.
go back to reference Liu D, Yao S, Wise GE (2006) Effect of interleukin-10 on gene expression of osteoclastogenic regulatory molecules in the rat dental follicle. Eur J Oral Sci 114:42–49CrossRefPubMed Liu D, Yao S, Wise GE (2006) Effect of interleukin-10 on gene expression of osteoclastogenic regulatory molecules in the rat dental follicle. Eur J Oral Sci 114:42–49CrossRefPubMed
48.
go back to reference Schierano G, Bellone G, Cassarino E, Pagano M, Preti G, Emanuelli G (2003) Transforming growth factor-beta and interleukin 10 in oral implant sites in humans. J Dent Res 82:428–432CrossRefPubMed Schierano G, Bellone G, Cassarino E, Pagano M, Preti G, Emanuelli G (2003) Transforming growth factor-beta and interleukin 10 in oral implant sites in humans. J Dent Res 82:428–432CrossRefPubMed
49.
go back to reference Negri BM, Pimentel SP, Casati MZ, Cirano FR, Casarin RC, Ribeiro FV (2016) Impact of a chronic smoking habit on the osteo-immunoinflammatory mediators in the peri-implant fluid of clinically healthy dental implants. Arch Oral Biol 70:55–61CrossRefPubMed Negri BM, Pimentel SP, Casati MZ, Cirano FR, Casarin RC, Ribeiro FV (2016) Impact of a chronic smoking habit on the osteo-immunoinflammatory mediators in the peri-implant fluid of clinically healthy dental implants. Arch Oral Biol 70:55–61CrossRefPubMed
50.
go back to reference Sayardoust S, Omar O, Thomsen P (2017) Gene expression in peri-implant crevicular fluid of smokers and nonsmokers. 1. The early phase of osseointegration. Clin Implant Dent Relat Res 19:681–693CrossRefPubMed Sayardoust S, Omar O, Thomsen P (2017) Gene expression in peri-implant crevicular fluid of smokers and nonsmokers. 1. The early phase of osseointegration. Clin Implant Dent Relat Res 19:681–693CrossRefPubMed
51.
go back to reference Gokmenoglu C, Ozmeric N, Erguder I, Elgun S (2014) The effect of light-emitting diode photobiomodulation on implant stability and biochemical markers in peri-implant crevicular fluid. Photomed Laser Surg 32:138–145CrossRefPubMed Gokmenoglu C, Ozmeric N, Erguder I, Elgun S (2014) The effect of light-emitting diode photobiomodulation on implant stability and biochemical markers in peri-implant crevicular fluid. Photomed Laser Surg 32:138–145CrossRefPubMed
52.
go back to reference Salvi GE, Lang NP (2004) Diagnostic parameters for monitoring peri-implant conditions. Int J Oral Maxillofac Implants 19(Suppl):116–127PubMed Salvi GE, Lang NP (2004) Diagnostic parameters for monitoring peri-implant conditions. Int J Oral Maxillofac Implants 19(Suppl):116–127PubMed
53.
go back to reference Bouri A, Bissada N, Al-Zahrani MS et al (2008) Width of keratinized gingiva and the health status of the supporting tissues around dental implants. Int J Oral Maxillofac Implants 23:323–326PubMed Bouri A, Bissada N, Al-Zahrani MS et al (2008) Width of keratinized gingiva and the health status of the supporting tissues around dental implants. Int J Oral Maxillofac Implants 23:323–326PubMed
54.
go back to reference Lin G-H, Chan H-L, Wang H-L (2013) The significance of keratinized mucosa on implant health: a systematic review. J Periodontol 84:1755–1767CrossRefPubMed Lin G-H, Chan H-L, Wang H-L (2013) The significance of keratinized mucosa on implant health: a systematic review. J Periodontol 84:1755–1767CrossRefPubMed
55.
go back to reference Gobbato L, Avila-Ortiz G, Sohrabi K, Wang CW, Karimbux N (2013) The effect of keratinized mucosa width on peri-implant health: a systematic review. Int J Oral Maxillofac Implants 28:1536–1545CrossRefPubMed Gobbato L, Avila-Ortiz G, Sohrabi K, Wang CW, Karimbux N (2013) The effect of keratinized mucosa width on peri-implant health: a systematic review. Int J Oral Maxillofac Implants 28:1536–1545CrossRefPubMed
56.
go back to reference Souza AB, Tormena M, Matarazzo F, Araújo MG (2016) The influence of peri-implant keratinized mucosa on brushing discomfort and peri-implant tissue health. Clin Oral Implants Res 27:650–655CrossRefPubMed Souza AB, Tormena M, Matarazzo F, Araújo MG (2016) The influence of peri-implant keratinized mucosa on brushing discomfort and peri-implant tissue health. Clin Oral Implants Res 27:650–655CrossRefPubMed
57.
go back to reference Kissa J, El Kholti W, Laalou Y, El Farouki M (2017) Augmentation of keratinized gingiva around dental implants. J Stomatol Oral Maxillofac Surg 118:156–160CrossRefPubMed Kissa J, El Kholti W, Laalou Y, El Farouki M (2017) Augmentation of keratinized gingiva around dental implants. J Stomatol Oral Maxillofac Surg 118:156–160CrossRefPubMed
58.
go back to reference Marcello-Machado RM, Faot F, Schuster AJ, Nascimento GG, del Bel Cury AA (2018) Mini-implants and narrow diameter implants as mandibular overdenture retainers: a systematic review and meta-analysis of clinical and radiographic outcomes. J Oral Rehabil 45:161–183CrossRefPubMed Marcello-Machado RM, Faot F, Schuster AJ, Nascimento GG, del Bel Cury AA (2018) Mini-implants and narrow diameter implants as mandibular overdenture retainers: a systematic review and meta-analysis of clinical and radiographic outcomes. J Oral Rehabil 45:161–183CrossRefPubMed
Metadata
Title
Mapping of inflammatory biomarkers in the peri-implant crevicular fluid before and after the occlusal loading of narrow diameter implants
Authors
Raissa Micaella Marcello-Machado
Fernanda Faot
Alessandra Julie Schuster
Amália Machado Bielemann
Gustavo Giacomelli Nascimento
Altair Antoninha Del Bel Cury
Publication date
01-03-2020
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 3/2020
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-019-03010-y

Other articles of this Issue 3/2020

Clinical Oral Investigations 3/2020 Go to the issue