Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 7/2014

01-10-2014 | Original Article

Custom-fit total knee arthroplasty: our initial experience with 30 knees

Authors: Enrico Bonicoli, Lorenzo Andreani, Paolo Parchi, Nicola Piolanti, Michele Lisanti

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 7/2014

Login to get access

Abstract

We report our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 30 TKAs from December 2010 to September 2012. Customized blocks were generated for each of the knees using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 30 days, long-leg radiographs were obtained to evaluate the coronal alignment. Twenty-six of the 30 knees had a mechanical axis restored to within 3° of neutral. We conclude that this technology can be safely used in most of the cases of osteoarthritis.
Literature
1.
go back to reference Watanabe H, Akizuki S, Takizawa T (2004) Survival analysis of a cementless, cruciate-retaining total knee arthroplasty. Clinical and radiographic assessment 10–13 years after surgery. J Bone Jt Surg Br 86:824–882CrossRef Watanabe H, Akizuki S, Takizawa T (2004) Survival analysis of a cementless, cruciate-retaining total knee arthroplasty. Clinical and radiographic assessment 10–13 years after surgery. J Bone Jt Surg Br 86:824–882CrossRef
2.
go back to reference Wright RJ, Sledge CB, Poss R, Ewald FC, Walsh ME, Lingard EA (2004) Patient-reported outcome and survivorship after kinemax total arthroplasty. J Bone Jt Surg Am 86A:2464–2470 Wright RJ, Sledge CB, Poss R, Ewald FC, Walsh ME, Lingard EA (2004) Patient-reported outcome and survivorship after kinemax total arthroplasty. J Bone Jt Surg Am 86A:2464–2470
3.
go back to reference Garg A, Walker PS (1990) Prediction of total knee motion using a three-dimensional computer-graphics model. J Biomech 23:45PubMedCrossRef Garg A, Walker PS (1990) Prediction of total knee motion using a three-dimensional computer-graphics model. J Biomech 23:45PubMedCrossRef
4.
go back to reference Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Jt Br 73:709 Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Jt Br 73:709
5.
go back to reference Mahaluxmivala J, Bankes MJ, Nicolai P et al (2009) The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplast 24:560CrossRef Mahaluxmivala J, Bankes MJ, Nicolai P et al (2009) The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplast 24:560CrossRef
6.
go back to reference Kalairajah Y, Cossey AJ, Verrall GM et al (2006) Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Jt Surg Br 88:198CrossRef Kalairajah Y, Cossey AJ, Verrall GM et al (2006) Are systemic emboli reduced in computer-assisted knee surgery? A prospective, randomised, clinical trial. J Bone Jt Surg Br 88:198CrossRef
7.
go back to reference Jerosch J, Peuker E, Philipps B et al (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc 10:194PubMedCrossRef Jerosch J, Peuker E, Philipps B et al (2002) Interindividual reproducibility in perioperative rotational alignment of femoral components in knee prosthetic surgery using the transepicondylar axis. Knee Surg Sports Traumatol Arthrosc 10:194PubMedCrossRef
8.
go back to reference Bohannon Mason J, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22(8):1097–1106CrossRef Bohannon Mason J, Fehring TK, Estok R, Banel D, Fahrbach K (2007) Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplast 22(8):1097–1106CrossRef
9.
go back to reference Lombardi AV Jr, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31:927PubMedCrossRef Lombardi AV Jr, Berend KR, Adams JB (2008) Patient-specific approach in total knee arthroplasty. Orthopedics 31:927PubMedCrossRef
10.
go back to reference Mahaluxmivala J, Bankes MJ, Nicolai P et al (2001) The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplast 16(5):635–640CrossRef Mahaluxmivala J, Bankes MJ, Nicolai P et al (2001) The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties. J Arthroplast 16(5):635–640CrossRef
11.
go back to reference Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53PubMedCentralPubMedCrossRef Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) Is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53PubMedCentralPubMedCrossRef
12.
go back to reference Parrate S, Trousdale R, Berry DJ, Pagnano MW (2008) Reproducing the mechanical axis did not improve the 15-year survival of 398 modern TKA. Scientific presentation, AAOS, Annual meeting, San Francisco, CA Parrate S, Trousdale R, Berry DJ, Pagnano MW (2008) Reproducing the mechanical axis did not improve the 15-year survival of 398 modern TKA. Scientific presentation, AAOS, Annual meeting, San Francisco, CA
13.
go back to reference Matzolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89(2):236–243CrossRef Matzolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Jt Surg Am 89(2):236–243CrossRef
14.
go back to reference Conteduca F, Iorio R, Mazza D, Caperna L Bolle G, Argento G, Ferretti A (2012) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc, June. doi:10.1007/s00167-012-2098-z Conteduca F, Iorio R, Mazza D, Caperna L Bolle G, Argento G, Ferretti A (2012) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc, June. doi:10.​1007/​s00167-012-2098-z
Metadata
Title
Custom-fit total knee arthroplasty: our initial experience with 30 knees
Authors
Enrico Bonicoli
Lorenzo Andreani
Paolo Parchi
Nicola Piolanti
Michele Lisanti
Publication date
01-10-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 7/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1304-0

Other articles of this Issue 7/2014

European Journal of Orthopaedic Surgery & Traumatology 7/2014 Go to the issue