Published in: European Archives of Oto-Rhino-Laryngology 12/2013

01-11-2013 | Miscellaneous

Cross-contamination and cross-infection risk of otoscope heads

Authors: Hakan Korkmaz, Yeliz Çetinkol, Mukadder Korkmaz

Published in: European Archives of Oto-Rhino-Laryngology | Issue 12/2013

Login to get access

Abstract

Adequate disinfection level of the medical equipments should be maintained to prevent cross-contamination between patients. Otoscope specula are usually cleaned and disinfected appropriately after each use by disinfectant solutions. However, since otoscope heads are electrical instruments with irregular inner surface they may still harbor pathogenic microorganisms. According to manufacturers’ instructions, otoscope heads can be cleaned externally with a damp cloth and they can be disinfected with aldehydes, tensides, and alcohols. Instrument heads should not be placed in liquids. Alcohols cannot be used on glass surfaces. How often an otoscope head must be cleaned to limit contamination is not well established. This study aimed to determine whether the otoscope heads harbor pathogenic microorganisms or not. A total of 53 otoscope heads were included in the study. Swab samples were obtained from the inner parts of the otoscope heads. For bacteriological examination, cotton swabs were inoculated onto 5 % sheep blood agar, chocolate agar, and eosine methylene blue agar plates. For fungal evaluation, cotton swabs were inoculated onto Sabouraud dextrose agars. Cultured microorganisms were evaluated macroscopically and microscopically. Of the 53 otoscope heads, 22 were found to be contaminated with bacteria and/or fungi. Eleven of them were colonized by one organism, 11 were colonized by more than one organism. Only one Pseudomonas species isolated as gram-negative microorganism. Gram-positive microorganisms were isolated from the remaining 19 samples. Staphylococcus species were the most common bacteria isolated. The most common fungal isolates were Aspergillus species. Two cultures were positive with Candida albicans. The results show that decontamination of the otoscope heads is usually ignored. However, they can harbor considerable amount of pathogenic microorganisms. The probability of contamination and the risk of cross-infection is high if they are used by otolaryngologists. In order to prevent cross-contamination between patients, guidelines indicating appropriate methods and frequency of cleaning and disinfection of otoscope heads needed to be described.
Literature
1.
go back to reference Spaulding EH (1968) Chemical disinfection of medical and surgical materials. In: Lawrence CA, Block SS (eds) Disinfection sterilisation and preservation. Lea and Febiger, Philadelphia, pp 517–531 Spaulding EH (1968) Chemical disinfection of medical and surgical materials. In: Lawrence CA, Block SS (eds) Disinfection sterilisation and preservation. Lea and Febiger, Philadelphia, pp 517–531
2.
go back to reference Clinical and Laboratory Standards Institute (CLSI) (2011) Performance standards for antimicrobial susceptibility testing; twenty first informational supplement. M100-S21. CLSI, Wayne Clinical and Laboratory Standards Institute (CLSI) (2011) Performance standards for antimicrobial susceptibility testing; twenty first informational supplement. M100-S21. CLSI, Wayne
3.
go back to reference Winn WC Jr, Allen SD, Janda WM et al (2006) Laboratory approach to the diagnosis of fungal infections. In: Koneman’s Color Atlas and Textbook of Diagnostic Microbiology 6th edn. Lippincott Williams, Philadelphia, pp 1156–1166 Winn WC Jr, Allen SD, Janda WM et al (2006) Laboratory approach to the diagnosis of fungal infections. In: Koneman’s Color Atlas and Textbook of Diagnostic Microbiology 6th edn. Lippincott Williams, Philadelphia, pp 1156–1166
4.
go back to reference Winn WC Jr, Allen SD, Janda WM et al (2006) Hyaline molds and hyalohyphomycosis. In: Koneman’s Color Atlas and Textbook of Diagnostic Microbiology, 6th edn. Lippincott Williams, Philadelphia, pp 1172–1187 Winn WC Jr, Allen SD, Janda WM et al (2006) Hyaline molds and hyalohyphomycosis. In: Koneman’s Color Atlas and Textbook of Diagnostic Microbiology, 6th edn. Lippincott Williams, Philadelphia, pp 1172–1187
5.
go back to reference Martinez JA, Ruthazer R, Hansjosten K, Barefoot L, Snydman DR (2003) Role of environmental contamination as a risk factor for acquisition of vancomycin-resistant enterococci in patients treated in a medical intensive care unit. Arch Intern Med 163:1905–1912PubMedCrossRef Martinez JA, Ruthazer R, Hansjosten K, Barefoot L, Snydman DR (2003) Role of environmental contamination as a risk factor for acquisition of vancomycin-resistant enterococci in patients treated in a medical intensive care unit. Arch Intern Med 163:1905–1912PubMedCrossRef
6.
go back to reference Falk PS, Winnike J, Woodmansee C, Desai M, Mayhall CG (2000) Outbreak of vancomycin-resistant enterococci in a burn unit. Infect Control Hosp Epidemiol 21:575–582PubMedCrossRef Falk PS, Winnike J, Woodmansee C, Desai M, Mayhall CG (2000) Outbreak of vancomycin-resistant enterococci in a burn unit. Infect Control Hosp Epidemiol 21:575–582PubMedCrossRef
7.
go back to reference Schabrun S, Chipchase L (2006) Healthcare equipment as a source of nosocomial infection: a systematic review. J Hosp Infect 63(3):239–245PubMedCrossRef Schabrun S, Chipchase L (2006) Healthcare equipment as a source of nosocomial infection: a systematic review. J Hosp Infect 63(3):239–245PubMedCrossRef
8.
go back to reference Bronowicki JP, Venard V, Botte C et al (1997) Patient-to-patient transmission of hepatitis C virus during colonoscopy. N Engl J Med 337:237–240PubMedCrossRef Bronowicki JP, Venard V, Botte C et al (1997) Patient-to-patient transmission of hepatitis C virus during colonoscopy. N Engl J Med 337:237–240PubMedCrossRef
9.
go back to reference Birnie GG, Quigley EM, Clements GB, Follet EA, Watkinson G (1983) Endoscopic transmission of hepatitis B virus. Gut 24:171–174PubMedCrossRef Birnie GG, Quigley EM, Clements GB, Follet EA, Watkinson G (1983) Endoscopic transmission of hepatitis B virus. Gut 24:171–174PubMedCrossRef
10.
go back to reference Frommeyer L, Bihl P, Schmidt-Wilcke HA (1991) Iatrogenic Candida infection in pancreatic pseudocycst. Z Gastroenterol 29:392–394PubMed Frommeyer L, Bihl P, Schmidt-Wilcke HA (1991) Iatrogenic Candida infection in pancreatic pseudocycst. Z Gastroenterol 29:392–394PubMed
11.
go back to reference Singh S, Singh N, Kochbar R, Mehta SK, Talwar P (1989) Contamination of an endoscope due to Trichosporon beigelii. J Hosp Infect 14:49–53PubMedCrossRef Singh S, Singh N, Kochbar R, Mehta SK, Talwar P (1989) Contamination of an endoscope due to Trichosporon beigelii. J Hosp Infect 14:49–53PubMedCrossRef
12.
go back to reference Lo Passo C, Pernice I, Celeste A, Perdichizzi G, Todaro-Luck F (2001) Transmission of Trichosporon asahii oesophagitis by a contaminated endoscope. Mycoses 44:13–21PubMedCrossRef Lo Passo C, Pernice I, Celeste A, Perdichizzi G, Todaro-Luck F (2001) Transmission of Trichosporon asahii oesophagitis by a contaminated endoscope. Mycoses 44:13–21PubMedCrossRef
Metadata
Title
Cross-contamination and cross-infection risk of otoscope heads
Authors
Hakan Korkmaz
Yeliz Çetinkol
Mukadder Korkmaz
Publication date
01-11-2013
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 12/2013
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-013-2539-4

Other articles of this Issue 12/2013

European Archives of Oto-Rhino-Laryngology 12/2013 Go to the issue