Skip to main content
Top
Published in: BMC Medicine 1/2022

01-12-2022 | COVID-19 Vaccination | Research article

Detection of SARS-CoV-2 infection in the general population by three prevailing rapid antigen tests: cross-sectional diagnostic accuracy study

Authors: Roderick P. Venekamp, Irene K. Veldhuijzen, Karel G. M. Moons, Wouter van den Bijllaardt, Suzan D. Pas, Esther B. Lodder, Richard Molenkamp, Zsofi Igloi, Constantijn Wijers, Claudy Oliveira dos Santos, Sylvia B. Debast, Marjan J. Bruins, Khaled Polad, Carla R. S. Nagel-Imming, Wanda G. H. Han, Janneke H. H. M. van de Wijgert, Susan van den Hof, Ewoud Schuit

Published in: BMC Medicine | Issue 1/2022

Login to get access

Abstract

Background

Rapid antigen diagnostic tests (Ag-RDTs) are the most widely used point-of-care tests for detecting SARS-CoV-2 infection. Since the accuracy may have altered by changes in SARS-CoV-2 epidemiology, indications for testing, sampling and testing procedures, and roll-out of COVID-19 vaccination, we evaluated the performance of three prevailing SARS-CoV-2 Ag-RDTs.

Methods

In this cross-sectional study, we consecutively enrolled individuals aged >16 years presenting for SARS-CoV-2 testing at three Dutch public health service COVID-19 test sites. In the first phase, participants underwent either BD-Veritor System (Becton Dickinson), PanBio (Abbott), or SD-Biosensor (Roche Diagnostics) testing with routine sampling procedures. In a subsequent phase, participants underwent SD-Biosensor testing with a less invasive sampling method (combined oropharyngeal-nasal [OP-N] swab). Diagnostic accuracies were assessed against molecular testing.

Results

Six thousand nine hundred fifty-five of 7005 participants (99%) with results from both an Ag-RDT and a molecular reference test were analysed. SARS-CoV-2 prevalence and overall sensitivities were 13% (188/1441) and 69% (129/188, 95% CI 62–75) for BD-Veritor, 8% (173/2056) and 69% (119/173, 61–76) for PanBio, and 12% (215/1769) and 74% (160/215, 68–80) for SD-Biosensor with routine sampling and 10% (164/1689) and 75% (123/164, 68–81) for SD-Biosensor with OP-N sampling. In those symptomatic or asymptomatic at sampling, sensitivities were 72–83% and 54–56%, respectively. Above a viral load cut-off (≥5.2 log10 SARS-CoV-2 E-gene copies/mL), sensitivities were 86% (125/146, 79–91) for BD-Veritor, 89% (108/121, 82–94) for PanBio, and 88% (160/182, 82–92) for SD-Biosensor with routine sampling and 84% (118/141, 77–89) with OP-N sampling. Specificities were >99% for all tests in most analyses. Sixty-one per cent of false-negative Ag-RDT participants returned for testing within 14 days (median: 3 days, interquartile range 3) of whom 90% tested positive.

Conclusions

Overall sensitivities of three SARS-CoV-2 Ag-RDTs were 69–75%, increasing to ≥86% above a viral load cut-off. The decreased sensitivity among asymptomatic participants and high positivity rate during follow-up in false-negative Ag-RDT participants emphasise the need for education of the public about the importance of re-testing after an initial negative Ag-RDT should symptoms develop. For SD-Biosensor, the diagnostic accuracy with OP-N and deep nasopharyngeal sampling was similar; adopting the more convenient sampling method might reduce the threshold for professional testing.
Appendix
Available only for authorised users
Literature
1.
go back to reference WHO. Recommendations for national SARS-CoV-2 testing strategies and diagnostic capacities: interim guidance 25 June 2021. Geneva: WHO; 2021. p. 1–16. WHO. Recommendations for national SARS-CoV-2 testing strategies and diagnostic capacities: interim guidance 25 June 2021. Geneva: WHO; 2021. p. 1–16.
3.
go back to reference WHO. Antigen-detection in the diagnosis of SARS-CoV-2 infection: interim guidance 6 October 2021. Geneva: WHO; 2021. p. 1–20. WHO. Antigen-detection in the diagnosis of SARS-CoV-2 infection: interim guidance 6 October 2021. Geneva: WHO; 2021. p. 1–20.
23.
go back to reference Marks M, Millat-Martinez P, Ouchi D, et al. Transmission of COVID-19 in 282 clusters in Catalonia, Spain: a cohort study. Lancet Infect Dis. 2021;21(5):629–38.CrossRefPubMedPubMedCentral Marks M, Millat-Martinez P, Ouchi D, et al. Transmission of COVID-19 in 282 clusters in Catalonia, Spain: a cohort study. Lancet Infect Dis. 2021;21(5):629–38.CrossRefPubMedPubMedCentral
24.
Metadata
Title
Detection of SARS-CoV-2 infection in the general population by three prevailing rapid antigen tests: cross-sectional diagnostic accuracy study
Authors
Roderick P. Venekamp
Irene K. Veldhuijzen
Karel G. M. Moons
Wouter van den Bijllaardt
Suzan D. Pas
Esther B. Lodder
Richard Molenkamp
Zsofi Igloi
Constantijn Wijers
Claudy Oliveira dos Santos
Sylvia B. Debast
Marjan J. Bruins
Khaled Polad
Carla R. S. Nagel-Imming
Wanda G. H. Han
Janneke H. H. M. van de Wijgert
Susan van den Hof
Ewoud Schuit
Publication date
01-12-2022
Publisher
BioMed Central
Published in
BMC Medicine / Issue 1/2022
Electronic ISSN: 1741-7015
DOI
https://doi.org/10.1186/s12916-022-02300-9

Other articles of this Issue 1/2022

BMC Medicine 1/2022 Go to the issue