Abstract

Background

Patient-reported outcome measures (PROMs) are an important resource for clinicians wishing to provide high-quality, patient-centered care. Finding PROMs to use in a pediatric clinical practice that are reliable, age appropriate, succinct, and not redundant is challenging.

Questions/Purposes

We sought to determine the degree of correlation between two pediatric PROMs, the Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS) and the PROMIS Pediatric Mobility (PROMIS PM) instrument, when administered at patients’ initial visit. We hypothesized that there would be a positive correlation between the two questionnaires because of their focus on physical function.

Methods

We conducted a retrospective cross-sectional review of 294 pediatric patients (mean age, 13.7 years) with localized lower-extremity joint pathologies at our high-volume urban pediatric sports practice. The patients had been asked to complete both PROMs on a computerized platform.

Results

We found a positive and statistically significant—albeit modest—correlation between the scores obtained on the HSS Pedi-FABS and the PROMIS PM. Neither instrument significantly correlated with patient age, nor were floor and ceiling effects observed.

Conclusion

The study shows that although both PROM instruments provide valuable information about pediatric physical function, they are not redundant because they measure slightly different constructs. Future studies should further investigate the correlation between these questionnaires in specific subpopulations of pediatric patients with lower-extremity pathology.
Literature
1.
go back to reference Amtmann D, Bamer A, Cook K, Harniss M, Johnson K. Adapting PROMIS physical function items for users of assistive technology. Disabil Health J. 2010;3(2):E9.CrossRef Amtmann D, Bamer A, Cook K, Harniss M, Johnson K. Adapting PROMIS physical function items for users of assistive technology. Disabil Health J. 2010;3(2):E9.CrossRef
2.
go back to reference Anthony CA, Glass NA, Hancock K, Bollier M, Wolf BR, Hettrich CM. Performance of PROMIS instruments in patients with shoulder instability. Am J Sports Med. 2017;45(2):449–453.CrossRef Anthony CA, Glass NA, Hancock K, Bollier M, Wolf BR, Hettrich CM. Performance of PROMIS instruments in patients with shoulder instability. Am J Sports Med. 2017;45(2):449–453.CrossRef
3.
4.
go back to reference Brook EM, GK, Higgins LD, Matzkin EG. Implementing patient-reported outcome measures in your practice: pearls and pitfalls. Am J Orthop. 2017;46(6):273–278.PubMed Brook EM, GK, Higgins LD, Matzkin EG. Implementing patient-reported outcome measures in your practice: pearls and pitfalls. Am J Orthop. 2017;46(6):273–278.PubMed
5.
go back to reference Dewitt EM, Stucky BD, Thissen D. Construction of the eight-item patient-reported outcomes measurement information system pediatric physical function scales: built using item response theory. J Clin Epidemiol. 2011;64(7):794–804.CrossRef Dewitt EM, Stucky BD, Thissen D. Construction of the eight-item patient-reported outcomes measurement information system pediatric physical function scales: built using item response theory. J Clin Epidemiol. 2011;64(7):794–804.CrossRef
6.
go back to reference Edelen MO, Reeve BB. Applying item response theory (IRT) modeling to questionnaire development, evaluation, and refinement. Qual Life Res. 2007;16 Suppl 1:5–18.CrossRef Edelen MO, Reeve BB. Applying item response theory (IRT) modeling to questionnaire development, evaluation, and refinement. Qual Life Res. 2007;16 Suppl 1:5–18.CrossRef
7.
go back to reference Fabricant PD, Robles A, Downey-Zayas T, et al. Development and validation of a pediatric sports activity rating scale: the Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS). Am J Sports Med. 2013;41(10):2421–2429. Fabricant PD, Robles A, Downey-Zayas T, et al. Development and validation of a pediatric sports activity rating scale: the Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS). Am J Sports Med. 2013;41(10):2421–2429.
8.
go back to reference Fabricant PD, Robles A, McLaren SH, Marx RG, Widmann RF, Green DW. Hospital for Special Surgery Pediatric Functional Activity Brief Scale predicts physical fitness testing performance. Clin Orthop Relat Res. 2014;472(5):1610–1616.CrossRef Fabricant PD, Robles A, McLaren SH, Marx RG, Widmann RF, Green DW. Hospital for Special Surgery Pediatric Functional Activity Brief Scale predicts physical fitness testing performance. Clin Orthop Relat Res. 2014;472(5):1610–1616.CrossRef
9.
go back to reference Fabricant PD, Suryavanshi JR, Calcei JG, Marx RG, Widmann RF, Green DW. The Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS): normative data. Am J Sports Med. 2018;46(5):1228–1234.CrossRef Fabricant PD, Suryavanshi JR, Calcei JG, Marx RG, Widmann RF, Green DW. The Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS): normative data. Am J Sports Med. 2018;46(5):1228–1234.CrossRef
11.
go back to reference Gagnier JJ. Patient reported outcomes in orthopaedics. J Orthop Res. 2017;35(10):2098–2108.CrossRef Gagnier JJ. Patient reported outcomes in orthopaedics. J Orthop Res. 2017;35(10):2098–2108.CrossRef
13.
go back to reference Irwin DE, Gross HE, Stucky BD. Development of six PROMIS pediatrics proxy-report item banks. Health Qual Life Outcomes. 2012;10:22.CrossRef Irwin DE, Gross HE, Stucky BD. Development of six PROMIS pediatrics proxy-report item banks. Health Qual Life Outcomes. 2012;10:22.CrossRef
15.
go back to reference Lim CR, Harris K, Dawson J, Beard DJ, Fitzpatrick R, Price AJ. Floor and ceiling effects in the OHS: an analysis of the NHS PROMs data set. BMJ Open. 2015;5(7):e007765. Lim CR, Harris K, Dawson J, Beard DJ, Fitzpatrick R, Price AJ. Floor and ceiling effects in the OHS: an analysis of the NHS PROMs data set. BMJ Open. 2015;5(7):e007765.
16.
go back to reference Makhni EC, Meldau JE, Blanchett J, et al. Correlation of PROMIS Physical Function, Pain Interference, and Depression in Pediatric and Adolescent Patients in the ambulatory sports medicine clinic. Orthop J Sports Med. 2019;7(6):2325967119851100.CrossRef Makhni EC, Meldau JE, Blanchett J, et al. Correlation of PROMIS Physical Function, Pain Interference, and Depression in Pediatric and Adolescent Patients in the ambulatory sports medicine clinic. Orthop J Sports Med. 2019;7(6):2325967119851100.CrossRef
18.
go back to reference Owen RJ, Khan AZ, McAnany SJ, Peters C, Zebala LP. PROMIS correlation with NDI and VAS measurements of physical function and pain in surgical patients with cervical disc herniations and radiculopathy. J Neurosurg Spine. 2019;1–6. [Epub ahead of print]. https://doi.org/10.3171/2019.4.SPINE18422. Owen RJ, Khan AZ, McAnany SJ, Peters C, Zebala LP. PROMIS correlation with NDI and VAS measurements of physical function and pain in surgical patients with cervical disc herniations and radiculopathy. J Neurosurg Spine. 2019;1–6. [Epub ahead of print]. https://​doi.​org/​10.​3171/​2019.​4.​SPINE18422.
19.
go back to reference Owen RJ, Zebala LP, Peters C, McAnany S. PROMIS Physical Function Correlation With NDI and mJOA in the surgical cervical myelopathy patient population. Spine (Phila Pa 1976). 2018;43(8):550–555. Owen RJ, Zebala LP, Peters C, McAnany S. PROMIS Physical Function Correlation With NDI and mJOA in the surgical cervical myelopathy patient population. Spine (Phila Pa 1976). 2018;43(8):550–555.
22.
go back to reference Quinn H, Thissen D, Liu Y. Using item response theory to enrich and expand the PROMIS pediatric self report banks. Health Qual Life Outcomes 2014;12:160.CrossRef Quinn H, Thissen D, Liu Y. Using item response theory to enrich and expand the PROMIS pediatric self report banks. Health Qual Life Outcomes 2014;12:160.CrossRef
23.
go back to reference Rodday AM, Graham RJ, Weidner RA, Rothrock NE, Dewalt DA, Parsons SK. Leveraging pediatric PROMIS item banks to assess physical functioning in children at risk for severe functional loss. J Patient Rep Outcomes. 2017;1(1):10.CrossRef Rodday AM, Graham RJ, Weidner RA, Rothrock NE, Dewalt DA, Parsons SK. Leveraging pediatric PROMIS item banks to assess physical functioning in children at risk for severe functional loss. J Patient Rep Outcomes. 2017;1(1):10.CrossRef
24.
go back to reference Waljee JF, Carlozzi N, Franzblau LE, Zhong L, Chung KC. Applying the Patient-Reported Outcomes Measurement Information System to assess upper extremity function among children with congenital hand differences. Plast Reconstr Surg. 2015;136(2):200e–207e.CrossRef Waljee JF, Carlozzi N, Franzblau LE, Zhong L, Chung KC. Applying the Patient-Reported Outcomes Measurement Information System to assess upper extremity function among children with congenital hand differences. Plast Reconstr Surg. 2015;136(2):200e–207e.CrossRef
25.
go back to reference Weldring T, Smith SM. Patient-reported outcomes (PROs) and patient-reported outcome measures (PROMs). Health Serv Insights. 2013;6:61–68.PubMedPubMedCentral Weldring T, Smith SM. Patient-reported outcomes (PROs) and patient-reported outcome measures (PROMs). Health Serv Insights. 2013;6:61–68.PubMedPubMedCentral
Metadata
Title
Correlation Between the PROMIS Pediatric Mobility Instrument and the Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS)
Authors
Joshua Adjei, BA
Jonathan M. Schachne, BA
Daniel W. Green, MD, MS, FACS, FAAP
Peter D. Fabricant, MD, MPH
Publication date
01-12-2020
Publisher
Springer US
Published in
HSS Journal ® / Issue Special Issue 2/2020
Print ISSN: 1556-3316
Electronic ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-019-09726-7

Other articles of this Special Issue 2/2020

HSS Journal ® 2/2020 Go to the issue