Abstract

Dorsally angulated malunions of the distal radius have historically been corrected with an opening wedge osteotomy fixed with a dorsal plate. Volar locking plates may facilitate a less morbid approach to corrective osteotomies of the wrist. Eight consecutive patients with an average age of 40 years (range, 15–52 years) underwent correction of a distal radius deformity through a volar approach. Clinical follow-up averaged 17.4 months (range, 7–41 months). Preoperative radiographs revealed an average of 24° of dorsal tilt in patients with dorsal deformity. Postoperatively, their average measurement was <3° of volar tilt. Patients were initially ulnar-positive with an average of 4 mm ulnar-positive variance (range, 2–7 mm). This corrected to less than 1 mm postoperatively. Postoperative disabilities of the arm, shoulder, and hand (DASH), SF-12, and Mayo Wrist scores averaged 10.8, 40.5, and 82.5, respectively. There were no nonunions, and no plates required removal. Distal radius deformity can be effectively addressed through a volar approach with the use of a locking plate.
Literature
1.
go back to reference Adams BD. Effects of radial deformity on distal radioulnar joint mechanics. J Hand Surg (Am) 1993;18(3):492–8. Adams BD. Effects of radial deformity on distal radioulnar joint mechanics. J Hand Surg (Am) 1993;18(3):492–8.
2.
go back to reference Bacorn RW, Kurtzke JF. Colles’ fracture; a study of two thousand cases from the New York State Workmen’s Compensation Board. J Bone Jt Surg Am 1953;35-A(3):643–58. Bacorn RW, Kurtzke JF. Colles’ fracture; a study of two thousand cases from the New York State Workmen’s Compensation Board. J Bone Jt Surg Am 1953;35-A(3):643–58.
3.
go back to reference Bushnell BD, Bynum DK. Malunion of the distal radius. J Am Acad Orthop Surg 2007;15(1):27–40.PubMed Bushnell BD, Bynum DK. Malunion of the distal radius. J Am Acad Orthop Surg 2007;15(1):27–40.PubMed
4.
go back to reference Carter PR, Frederick HA, Laseter GF. Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 fractures. J Hand Surg (Am) 1998;23(2):300–7.CrossRef Carter PR, Frederick HA, Laseter GF. Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: a multicenter study of 73 fractures. J Hand Surg (Am) 1998;23(2):300–7.CrossRef
5.
go back to reference Cohen MS, Turner TM, Urban RM. Effects of implant material and plate design on tendon function and morphology. Clin Orthop Relat Res 2006;445:81–90.PubMed Cohen MS, Turner TM, Urban RM. Effects of implant material and plate design on tendon function and morphology. Clin Orthop Relat Res 2006;445:81–90.PubMed
6.
go back to reference Crisco JJ, Moore DC, Marai GE, Laidlaw DH, Akelman E, Weiss AP, Wolfe SW. Effects of distal radius malunion on distal radioulnar joint mechanics—an in vivo study. J Orthop Res 2007;25(4):547–55.PubMedCrossRef Crisco JJ, Moore DC, Marai GE, Laidlaw DH, Akelman E, Weiss AP, Wolfe SW. Effects of distal radius malunion on distal radioulnar joint mechanics—an in vivo study. J Orthop Res 2007;25(4):547–55.PubMedCrossRef
7.
go back to reference Fernandez DL. Radial osteotomy and Bowers arthroplasty for malunited fractures of the distal end of the radius. J Bone Jt Surg Am 1988;70(10):1538–51. Fernandez DL. Radial osteotomy and Bowers arthroplasty for malunited fractures of the distal end of the radius. J Bone Jt Surg Am 1988;70(10):1538–51.
8.
go back to reference Fernandez DL. Malunion of the distal radius: current approach to management. Instr Course Lect 1993;42:99–113.PubMed Fernandez DL. Malunion of the distal radius: current approach to management. Instr Course Lect 1993;42:99–113.PubMed
9.
go back to reference Fernandez DL. Reconstructive procedures for malunion and traumatic arthritis. Orthop Clin North Am 1993;24(2):341–63.PubMed Fernandez DL. Reconstructive procedures for malunion and traumatic arthritis. Orthop Clin North Am 1993;24(2):341–63.PubMed
10.
go back to reference Graham TJ. Surgical correction of malunited fractures of the distal radius. J Am Acad Orthop Surg 1997;5(5):270–81.PubMed Graham TJ. Surgical correction of malunited fractures of the distal radius. J Am Acad Orthop Surg 1997;5(5):270–81.PubMed
11.
go back to reference Hirahara H, Neale PG, Lin YT, Cooney WP, An KN. Kinematic and torque-related effects of dorsally angulated distal radius fractures and the distal radial ulnar joint. J Hand Surg (Am) 2003;28(4):614–21.CrossRef Hirahara H, Neale PG, Lin YT, Cooney WP, An KN. Kinematic and torque-related effects of dorsally angulated distal radius fractures and the distal radial ulnar joint. J Hand Surg (Am) 2003;28(4):614–21.CrossRef
12.
go back to reference Jansen JC, Adams BD. Long-term outcome of nonsurgically treated patients with wrist pain and a normal arthrogram. J Hand Surg (Am) 2002;27(1):26–30. Jansen JC, Adams BD. Long-term outcome of nonsurgically treated patients with wrist pain and a normal arthrogram. J Hand Surg (Am) 2002;27(1):26–30.
13.
go back to reference Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg (Am) 2006;31(7):1061–7.CrossRef Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg (Am) 2006;31(7):1061–7.CrossRef
14.
go back to reference Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg (Am) 1998;23(4):737–41.CrossRef Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg (Am) 1998;23(4):737–41.CrossRef
15.
go back to reference Keller M, Steiger R. Open reduction and internal fixation of distal radius extension fractures in women over 60 years of age with the dorsal radius plate (pi-plate). Handchir Mikrochir Plast Chir 2006;38(2):82–9.PubMedCrossRef Keller M, Steiger R. Open reduction and internal fixation of distal radius extension fractures in women over 60 years of age with the dorsal radius plate (pi-plate). Handchir Mikrochir Plast Chir 2006;38(2):82–9.PubMedCrossRef
16.
go back to reference Kihara H, Short WH, Werner FW, Fortino MD, Palmer AK. The stabilizing mechanism of the distal radioulnar joint during pronation and supination. J Hand Surg (Am) 1995;20(6):930–6.CrossRef Kihara H, Short WH, Werner FW, Fortino MD, Palmer AK. The stabilizing mechanism of the distal radioulnar joint during pronation and supination. J Hand Surg (Am) 1995;20(6):930–6.CrossRef
17.
go back to reference Kihara H, Palmer AK, Werner FW, Short WH, Fortino MD. The effect of dorsally angulated distal radius fractures on distal radioulnar joint congruency and forearm rotation. J Hand Surg (Am) 1996;21(1):40–7.CrossRef Kihara H, Palmer AK, Werner FW, Short WH, Fortino MD. The effect of dorsally angulated distal radius fractures on distal radioulnar joint congruency and forearm rotation. J Hand Surg (Am) 1996;21(1):40–7.CrossRef
18.
go back to reference Koh S, Morris RP, Patterson RM, Kearney JP, Buford WL Jr, Viegas SF. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg (Am) 2006;31(5):771–9.CrossRef Koh S, Morris RP, Patterson RM, Kearney JP, Buford WL Jr, Viegas SF. Volar fixation for dorsally angulated extra-articular fractures of the distal radius: a biomechanical study. J Hand Surg (Am) 2006;31(5):771–9.CrossRef
19.
go back to reference Ladd AL, Huene DS. Reconstructive osteotomy for malunion of the distal radius. Clin Orthop Relat Res 1996;(327):158–71.PubMedCrossRef Ladd AL, Huene DS. Reconstructive osteotomy for malunion of the distal radius. Clin Orthop Relat Res 1996;(327):158–71.PubMedCrossRef
20.
go back to reference Malone KJ, Magnell TD, Freeman DC, Boyer MI, Placzek JD. Surgical correction of dorsally angulated distal radius malunions with fixed angle volar plating: a case series. J Hand Surg (Am) 2006;31(3):366–72.CrossRef Malone KJ, Magnell TD, Freeman DC, Boyer MI, Placzek JD. Surgical correction of dorsally angulated distal radius malunions with fixed angle volar plating: a case series. J Hand Surg (Am) 2006;31(3):366–72.CrossRef
21.
go back to reference Markolf KL, Lamey D, Yang S, Meals R, Hotchkiss R. Radioulnar load-sharing in the forearm. A study in cadavera. J Bone Jt Surg Am 1998;80(6):879–88. Markolf KL, Lamey D, Yang S, Meals R, Hotchkiss R. Radioulnar load-sharing in the forearm. A study in cadavera. J Bone Jt Surg Am 1998;80(6):879–88.
22.
go back to reference McKay SD, MacDermid JC, Roth JH, Richards RS. Assessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg (Am) 2001;26(5):916–22.CrossRef McKay SD, MacDermid JC, Roth JH, Richards RS. Assessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg (Am) 2001;26(5):916–22.CrossRef
23.
go back to reference Miyake T, Hashizume H, Inoue H, Shi Q, Nagayama N. Malunited Colles’ fracture. Analysis of stress distribution. J Hand Surg (Br) 1994;19(6):737–42. Miyake T, Hashizume H, Inoue H, Shi Q, Nagayama N. Malunited Colles’ fracture. Analysis of stress distribution. J Hand Surg (Br) 1994;19(6):737–42.
24.
go back to reference Nazzal A, Lozano-Calderon S, Jupiter JB, Rosenzweig JS, Randolph MA, Lee SG. A histologic analysis of the effects of stainless steel and titanium implants adjacent to tendons: an experimental rabbit study. J Hand Surg (Am) 2006;31(7):1123–30.CrossRef Nazzal A, Lozano-Calderon S, Jupiter JB, Rosenzweig JS, Randolph MA, Lee SG. A histologic analysis of the effects of stainless steel and titanium implants adjacent to tendons: an experimental rabbit study. J Hand Surg (Am) 2006;31(7):1123–30.CrossRef
25.
26.
go back to reference Orbay JL, Badia A, Indriago IR, Infante A, Khouri RK, Gonzalez E, Fernandez DL. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg 2001;5(4):204–11.PubMedCrossRef Orbay JL, Badia A, Indriago IR, Infante A, Khouri RK, Gonzalez E, Fernandez DL. The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Up Extrem Surg 2001;5(4):204–11.PubMedCrossRef
27.
go back to reference Park MJ, Cooney WP III, Hahn ME, Looi KP, An KN. The effects of dorsally angulated distal radius fractures on carpal kinematics. J Hand Surg (Am) 2002;27(2):223–32.CrossRef Park MJ, Cooney WP III, Hahn ME, Looi KP, An KN. The effects of dorsally angulated distal radius fractures on carpal kinematics. J Hand Surg (Am) 2002;27(2):223–32.CrossRef
28.
go back to reference Pogue DJ, Viegas SF, Patterson RM, Peterson PD, Jenkins DK, Sweo TD, Hokanson JA. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg (Am) 1990;15(5):721–7.CrossRef Pogue DJ, Viegas SF, Patterson RM, Peterson PD, Jenkins DK, Sweo TD, Hokanson JA. Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg (Am) 1990;15(5):721–7.CrossRef
29.
go back to reference Porter M, Stockley I. Fractures of the distal radius. Intermediate and end results in relation to radiologic parameters. Clin Orthop Relat Res 1987;(220):241–52. Porter M, Stockley I. Fractures of the distal radius. Intermediate and end results in relation to radiologic parameters. Clin Orthop Relat Res 1987;(220):241–52.
30.
go back to reference Prommersberger KJ, Lanz U. Biomechanical aspects of malunited distal radius fracture. A review of the literature. Handchir Mikrochir Plast Chir 1999;31(4):221–6.PubMedCrossRef Prommersberger KJ, Lanz U. Biomechanical aspects of malunited distal radius fracture. A review of the literature. Handchir Mikrochir Plast Chir 1999;31(4):221–6.PubMedCrossRef
31.
go back to reference Prommersberger KJ, Lanz UB. Corrective osteotomy of the distal radius through volar approach. Tech Hand Up Extrem Surg 2004;8(2):70–7.PubMedCrossRef Prommersberger KJ, Lanz UB. Corrective osteotomy of the distal radius through volar approach. Tech Hand Up Extrem Surg 2004;8(2):70–7.PubMedCrossRef
32.
go back to reference Prommersberger KJ, Moossavi S, Lanz U. Results of corrective osteotomy of malunited extension fractures of the radius at the usual site. Handchir Mikrochir Plast Chir 1999;31(4):234–40.PubMedCrossRef Prommersberger KJ, Moossavi S, Lanz U. Results of corrective osteotomy of malunited extension fractures of the radius at the usual site. Handchir Mikrochir Plast Chir 1999;31(4):234–40.PubMedCrossRef
33.
go back to reference Prommersberger KJ, Froehner SC, Schmitt RR, Lanz UB. Rotational deformity in malunited fractures of the distal radius. J Hand Surg (Am) 2004;29(1):110–5.CrossRef Prommersberger KJ, Froehner SC, Schmitt RR, Lanz UB. Rotational deformity in malunited fractures of the distal radius. J Hand Surg (Am) 2004;29(1):110–5.CrossRef
34.
go back to reference Sanchez T, Jakubietz M, Jakubietz R, Mayer J, Beutel FK, Grunert J. Complications after Pi Plate osteosynthesis. Plast Reconstr Surg 2004;116(1):153–8.CrossRef Sanchez T, Jakubietz M, Jakubietz R, Mayer J, Beutel FK, Grunert J. Complications after Pi Plate osteosynthesis. Plast Reconstr Surg 2004;116(1):153–8.CrossRef
35.
go back to reference Sato S. Load transmission through the wrist joint: a biomechanical study comparing the normal and pathological wrist. Nippon Seikei Geka Gakkai Zasshi 1995;69(7):470–83. Sato S. Load transmission through the wrist joint: a biomechanical study comparing the normal and pathological wrist. Nippon Seikei Geka Gakkai Zasshi 1995;69(7):470–83.
36.
go back to reference Sauerbier M, Kluge S, Bickert B, Germann G. Subjective and objective outcomes after total wrist arthrodesis in patients with radiocarpal arthrosis or Kienbock’s disease. Chir Main 2000;19(4):223–31.PubMedCrossRef Sauerbier M, Kluge S, Bickert B, Germann G. Subjective and objective outcomes after total wrist arthrodesis in patients with radiocarpal arthrosis or Kienbock’s disease. Chir Main 2000;19(4):223–31.PubMedCrossRef
37.
go back to reference Schnur DP, Chang B. Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation. Ann Plast Surg 2000;44(5):564–6.PubMedCrossRef Schnur DP, Chang B. Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation. Ann Plast Surg 2000;44(5):564–6.PubMedCrossRef
38.
go back to reference Schroven I, De Smet L, Zachee B, Steenwerckx A, Fabry G. Radial osteotomy and Sauve–Kapandji procedure for deformities of the distal radius. Acta Orthop Belg 1995;61(1):1–5.PubMed Schroven I, De Smet L, Zachee B, Steenwerckx A, Fabry G. Radial osteotomy and Sauve–Kapandji procedure for deformities of the distal radius. Acta Orthop Belg 1995;61(1):1–5.PubMed
39.
go back to reference Sharpe F, Stevanovic M. Extra-articular distal radial fracture malunion. Hand Clin 2005;21(3):469–87.PubMedCrossRef Sharpe F, Stevanovic M. Extra-articular distal radial fracture malunion. Hand Clin 2005;21(3):469–87.PubMedCrossRef
40.
go back to reference Shea K, Fernandez DL, Jupiter JB, Martin C Jr. Corrective osteotomy for malunited, volarly displaced fractures of the distal end of the radius. J Bone Jt Surg Am 1997;79(12):1816–26. Shea K, Fernandez DL, Jupiter JB, Martin C Jr. Corrective osteotomy for malunited, volarly displaced fractures of the distal end of the radius. J Bone Jt Surg Am 1997;79(12):1816–26.
41.
go back to reference Simic PM, Robison J, Gardner MJ, Gelberman RH, Weiland AJ, Boyer MI. Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. J Hand Surg (Am) 2006;31(3):382–6.CrossRef Simic PM, Robison J, Gardner MJ, Gelberman RH, Weiland AJ, Boyer MI. Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. J Hand Surg (Am) 2006;31(3):382–6.CrossRef
42.
go back to reference Smith DW, Henry MH. Volar fixed-angle plating of the distal radius. J Am Acad Orthop Surg 2005;13(1):28–36.PubMed Smith DW, Henry MH. Volar fixed-angle plating of the distal radius. J Am Acad Orthop Surg 2005;13(1):28–36.PubMed
43.
go back to reference Suckel A, Spies S, Munst P. Dorsal (AO/ASIF) pi-Plate osteosynthesis in the treatment of distal intraarticular radius fractures. J Hand Surg (Br) 2006;31(6):673–9. Suckel A, Spies S, Munst P. Dorsal (AO/ASIF) pi-Plate osteosynthesis in the treatment of distal intraarticular radius fractures. J Hand Surg (Br) 2006;31(6):673–9.
44.
go back to reference Szabo RM. Extra-articular fractures of the distal radius. Orthop Clin North Am 1993 24(2):229–37.PubMed Szabo RM. Extra-articular fractures of the distal radius. Orthop Clin North Am 1993 24(2):229–37.PubMed
45.
go back to reference Szabo RM, Hotchkiss RN, Slater RR Jr. The use of frozen-allograft radial head replacement for treatment of established symptomatic proximal translation of the radius: preliminary experience in five cases. J Hand Surg (Am) 1997;22(2):269–78.CrossRef Szabo RM, Hotchkiss RN, Slater RR Jr. The use of frozen-allograft radial head replacement for treatment of established symptomatic proximal translation of the radius: preliminary experience in five cases. J Hand Surg (Am) 1997;22(2):269–78.CrossRef
46.
go back to reference Taleisnik J, Watson HK. Midcarpal instability caused by malunited fractures of the distal radius. J Hand Surg (Am) 1984;9(3):350–7. Taleisnik J, Watson HK. Midcarpal instability caused by malunited fractures of the distal radius. J Hand Surg (Am) 1984;9(3):350–7.
47.
go back to reference Thivaios GC, McKee MD. Sliding osteotomy for deformity correction following malunion of volarly displaced distal radial fractures. J Orthop Trauma 2003;17(5):326–33.PubMedCrossRef Thivaios GC, McKee MD. Sliding osteotomy for deformity correction following malunion of volarly displaced distal radial fractures. J Orthop Trauma 2003;17(5):326–33.PubMedCrossRef
48.
go back to reference Tomaino MM. The importance of the pronated grip X-ray view in evaluating ulnar variance. J Hand Surg (Am) 2000;25(2):352–7.CrossRef Tomaino MM. The importance of the pronated grip X-ray view in evaluating ulnar variance. J Hand Surg (Am) 2000;25(2):352–7.CrossRef
49.
go back to reference Van Cauwelaert de Wyels J, De Smet L. Corrective osteotomy for malunion of the distal radius in young and middle-aged patients: an outcome study. Chir Main 2003;22(2):84–9.PubMedCrossRef Van Cauwelaert de Wyels J, De Smet L. Corrective osteotomy for malunion of the distal radius in young and middle-aged patients: an outcome study. Chir Main 2003;22(2):84–9.PubMedCrossRef
50.
go back to reference Van Schoonhoven J, Lanz U. Salvage operations and their differential indication for the distal radioulnar joint. Orthopade 2004;33(6):704–14.PubMedCrossRef Van Schoonhoven J, Lanz U. Salvage operations and their differential indication for the distal radioulnar joint. Orthopade 2004;33(6):704–14.PubMedCrossRef
51.
go back to reference Voche P, Merle M, Dautel G. Non-articular malunions of the distal radius: evaluation and techniques of correction. Rev Chir Orthop Repar Appar Mot 2001;87(3):263–75. Voche P, Merle M, Dautel G. Non-articular malunions of the distal radius: evaluation and techniques of correction. Rev Chir Orthop Repar Appar Mot 2001;87(3):263–75.
52.
go back to reference Wada T, Tsuji H, Iba K, Aoki M, Yamashita T. Simultaneous radial closing wedge and ulnar shortening osteotomy for distal radius malunion. Tech Hand Up Extrem Surg 2004;9(4):188–94.CrossRef Wada T, Tsuji H, Iba K, Aoki M, Yamashita T. Simultaneous radial closing wedge and ulnar shortening osteotomy for distal radius malunion. Tech Hand Up Extrem Surg 2004;9(4):188–94.CrossRef
53.
go back to reference Watson HK, Castle TH Jr. Trapezoidal osteotomy of the distal radius for unacceptable articular angulation after Colles’ fracture. J Hand Surg (Am) 1988;13(6):837–43. Watson HK, Castle TH Jr. Trapezoidal osteotomy of the distal radius for unacceptable articular angulation after Colles’ fracture. J Hand Surg (Am) 1988;13(6):837–43.
54.
go back to reference Werner FW, Glisson RR, Murphy DJ, Palmer AK. Force transmission through the distal radioulnar carpal joint: effect of ulnar lengthening and shortening. Handchir Mikrochir Plast Chir 1986;18(5):304–8.PubMed Werner FW, Glisson RR, Murphy DJ, Palmer AK. Force transmission through the distal radioulnar carpal joint: effect of ulnar lengthening and shortening. Handchir Mikrochir Plast Chir 1986;18(5):304–8.PubMed
55.
go back to reference Werner FW, Palmer AK, Fortino MD, Short WH. Force transmission through the distal ulna: effect of ulnar variance, lunate fossa angulation, and radial and palmar tilt of the distal radius. J Hand Surg (Am) 1992;17(3):423–8.CrossRef Werner FW, Palmer AK, Fortino MD, Short WH. Force transmission through the distal ulna: effect of ulnar variance, lunate fossa angulation, and radial and palmar tilt of the distal radius. J Hand Surg (Am) 1992;17(3):423–8.CrossRef
56.
go back to reference Yeh GL, Beredjiklian PK, Katz MA, Steinberg DR, Bozentka DJ. Effects of forearm rotation on the clinical evaluation of ulnar variance. J Hand Surg (Am) 2001;26(6):1042–6.CrossRef Yeh GL, Beredjiklian PK, Katz MA, Steinberg DR, Bozentka DJ. Effects of forearm rotation on the clinical evaluation of ulnar variance. J Hand Surg (Am) 2001;26(6):1042–6.CrossRef
Metadata
Title
Corrective Osteotomy for Deformity of the Distal Radius Using a Volar Locking Plate
Authors
Brett Peterson
Varun Gajendran
Robert M. Szabo
Publication date
01-03-2008
Publisher
Springer-Verlag
Published in
HAND / Issue 1/2008
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-007-9066-y

Other articles of this Issue 1/2008

HAND 1/2008 Go to the issue