Contrast-enhanced ultrasound: a new method for TIPS follow-up

Authors: Capucine Micol, Julien Marsot, Nawele Boublay, Frank Pilleul, Yves Berthezene, Agnès Rode

Published in: Abdominal Radiology | Issue 2/2012

Login to get access

Abstract

Purpose

To determine the diagnostic value of contrast-enhanced ultrasound (CEUS) for the detection of TIPS (transjugular intrahepatic portosystemic shunt) complications.

Materials and method

67 cirrhotic patients who underwent TIPS between 2001 and 2008 were retrospectively reviewed. Sixty-two vascular examinations in 37 patients for suspicion of TIPS dysfunction based on the clinical or radiological criteria were analyzed and compared with the 62 related Doppler and CEUS examinations obtained previously. Abnormal CEUS was defined as poor opacification of the prosthesis compared to the native portal vein, stent stenosis, hepatic vein stenosis, and occlusion of the stent.

Results

Among the 62 vascular examinations, 56 were considered as pathologic, including: 20 occlusions, 25 stent stenoses, 9 hepatic vein stenoses, 1 arterial-TIPS fistula, and 1 strong flow stealing through a voluminous paraumbilical vein associated with a patent shunt. 50 were exactly correlated with a previous CEUS examination, including 20/20 occlusions (100%), 23/25 stent stenoses (91%), 5/9 hepatic vein stenoses (56%), 1/1 fistula (100%), and 1/1 strong flow stealing (100%). Two CEUS and 14 Doppler examinations were false negative.

Conclusion

CEUS allows direct visualization of intra-prosthetic flow, with a qualitative and anatomic study, in addition to the Doppler examination. This is a new, simple, and effective technique for TIPS follow-up.
Literature
1.
go back to reference Richter GM, Noeldge G, Palmaz JC, et al. (1990) Transjugular intrahepatic portacaval stent shunt: preliminary clinical results. Radiology 174:1027–1030PubMed Richter GM, Noeldge G, Palmaz JC, et al. (1990) Transjugular intrahepatic portacaval stent shunt: preliminary clinical results. Radiology 174:1027–1030PubMed
2.
go back to reference Boyer TD (2008) Transjugular intrahepatic portosystemic shunt in the management of complications of portal hypertension. Curr Gastroenterol Rep 10:30–35PubMedCrossRef Boyer TD (2008) Transjugular intrahepatic portosystemic shunt in the management of complications of portal hypertension. Curr Gastroenterol Rep 10:30–35PubMedCrossRef
3.
go back to reference Bilbao JI, Quiroga J, Herrero JI, Benito A (2002) Transjugular intrahepatic portosystemic shunt (TIPS): current status and future possibilities. Cardiovasc Interv Radiol 25:251–269CrossRef Bilbao JI, Quiroga J, Herrero JI, Benito A (2002) Transjugular intrahepatic portosystemic shunt (TIPS): current status and future possibilities. Cardiovasc Interv Radiol 25:251–269CrossRef
4.
go back to reference Rossle M, Deibert P, Haag K, et al. (1997) Randomised trial of transjugular-intrahepatic-portosystemic shunt versus endoscopy plus propranolol for prevention of variceal rebleeding. Lancet 349:1043–1049PubMedCrossRef Rossle M, Deibert P, Haag K, et al. (1997) Randomised trial of transjugular-intrahepatic-portosystemic shunt versus endoscopy plus propranolol for prevention of variceal rebleeding. Lancet 349:1043–1049PubMedCrossRef
5.
go back to reference Ochs A, Rossle M, Haag K, et al. (1995) The transjugular intrahepatic portosystemic stent-shunt procedure for refractory ascites. N Engl J Med 332:1192–1197PubMedCrossRef Ochs A, Rossle M, Haag K, et al. (1995) The transjugular intrahepatic portosystemic stent-shunt procedure for refractory ascites. N Engl J Med 332:1192–1197PubMedCrossRef
6.
go back to reference Cura M, Cura A, Suri R, et al. (2008) Causes of TIPS dysfunction. AJR Am J Roentgenol 191:1751–1757PubMedCrossRef Cura M, Cura A, Suri R, et al. (2008) Causes of TIPS dysfunction. AJR Am J Roentgenol 191:1751–1757PubMedCrossRef
7.
go back to reference Ducoin H, El-Khoury J, Rousseau H, et al. (1997) Histopathologic analysis of transjugular intrahepatic portosystemic shunts. Hepatology 25:1064–1069PubMedCrossRef Ducoin H, El-Khoury J, Rousseau H, et al. (1997) Histopathologic analysis of transjugular intrahepatic portosystemic shunts. Hepatology 25:1064–1069PubMedCrossRef
8.
go back to reference Latimer J, Bawa SM, Rees CJ, et al. (1998) Patency and reintervention rates during routine TIPSS surveillance. Cardiovasc Interv Radiol 21:234–239CrossRef Latimer J, Bawa SM, Rees CJ, et al. (1998) Patency and reintervention rates during routine TIPSS surveillance. Cardiovasc Interv Radiol 21:234–239CrossRef
9.
go back to reference Stanley AJ, Jalan R, Forrest EH, et al. (1996) Longterm follow up of transjugular intrahepatic portosystemic stent shunt (TIPSS) for the treatment of portal hypertension: results in 130 patients. Gut 39:479–485PubMedCrossRef Stanley AJ, Jalan R, Forrest EH, et al. (1996) Longterm follow up of transjugular intrahepatic portosystemic stent shunt (TIPSS) for the treatment of portal hypertension: results in 130 patients. Gut 39:479–485PubMedCrossRef
10.
go back to reference Benito A, Bilbao J, Hernandez T, et al. (2004) Doppler ultrasound for TIPS: does it work? Abdom Imaging 29:45–52PubMedCrossRef Benito A, Bilbao J, Hernandez T, et al. (2004) Doppler ultrasound for TIPS: does it work? Abdom Imaging 29:45–52PubMedCrossRef
11.
go back to reference Chong WK, Malisch TA, Mazer MJ, et al. (1993) Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity. Radiology 189:789–793PubMed Chong WK, Malisch TA, Mazer MJ, et al. (1993) Transjugular intrahepatic portosystemic shunt: US assessment with maximum flow velocity. Radiology 189:789–793PubMed
12.
go back to reference Longo JM, Bilbao JI, Rousseau HP, et al. (1993) Transjugular intrahepatic portosystemic shunt: evaluation with Doppler sonography. Radiology 186:529–534PubMed Longo JM, Bilbao JI, Rousseau HP, et al. (1993) Transjugular intrahepatic portosystemic shunt: evaluation with Doppler sonography. Radiology 186:529–534PubMed
13.
go back to reference Lafortune M, Martinet JP, Denys A, et al. (1995) Short- and long-term hemodynamic effects of transjugular intrahepatic portosystemic shunts: a Doppler/manometric correlative study. AJR Am J Roentgenol 164:997–1002PubMed Lafortune M, Martinet JP, Denys A, et al. (1995) Short- and long-term hemodynamic effects of transjugular intrahepatic portosystemic shunts: a Doppler/manometric correlative study. AJR Am J Roentgenol 164:997–1002PubMed
14.
go back to reference Foshager MC, Ferral H, Nazarian GK, et al. (1995) Duplex sonography after transjugular intrahepatic portosystemic shunts (TIPS): normal hemodynamic findings and efficacy in predicting shunt patency and stenosis. AJR Am J Roentgenol 165:1–7PubMed Foshager MC, Ferral H, Nazarian GK, et al. (1995) Duplex sonography after transjugular intrahepatic portosystemic shunts (TIPS): normal hemodynamic findings and efficacy in predicting shunt patency and stenosis. AJR Am J Roentgenol 165:1–7PubMed
15.
go back to reference Dodd GD, 3rd, Zajko AB, Orons PD et al. (1995) Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography. AJR Am J Roentgenol 164:1119–1124 Dodd GD, 3rd, Zajko AB, Orons PD et al. (1995) Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography. AJR Am J Roentgenol 164:1119–1124
16.
go back to reference Feldstein VA, Patel MD, LaBerge JM (1996) Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses. Radiology 201:141–147PubMed Feldstein VA, Patel MD, LaBerge JM (1996) Transjugular intrahepatic portosystemic shunts: accuracy of Doppler US in determination of patency and detection of stenoses. Radiology 201:141–147PubMed
17.
go back to reference Kanterman RY, Darcy MD, Middleton WD, et al. (1997) Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction. AJR Am J Roentgenol 168:467–472PubMed Kanterman RY, Darcy MD, Middleton WD, et al. (1997) Doppler sonography findings associated with transjugular intrahepatic portosystemic shunt malfunction. AJR Am J Roentgenol 168:467–472PubMed
18.
go back to reference Owens CA, Bartolone C, Warner DL, et al. (1998) The inaccuracy of duplex ultrasonography in predicting patency of transjugular intrahepatic portosystemic shunts. Gastroenterology 114:975–980PubMedCrossRef Owens CA, Bartolone C, Warner DL, et al. (1998) The inaccuracy of duplex ultrasonography in predicting patency of transjugular intrahepatic portosystemic shunts. Gastroenterology 114:975–980PubMedCrossRef
19.
go back to reference Owens CA (1998) Ultrasound surveillance of tips-why bother? Gastroenterology 114:1433–1434CrossRef Owens CA (1998) Ultrasound surveillance of tips-why bother? Gastroenterology 114:1433–1434CrossRef
20.
go back to reference Zizka J, Elias P, Krajina A, et al. (2000) Value of Doppler sonography in revealing transjugular intrahepatic portosystemic shunt malfunction: a 5-year experience in 216 patients. AJR Am J Roentgenol 175:141–148PubMed Zizka J, Elias P, Krajina A, et al. (2000) Value of Doppler sonography in revealing transjugular intrahepatic portosystemic shunt malfunction: a 5-year experience in 216 patients. AJR Am J Roentgenol 175:141–148PubMed
21.
go back to reference Carrafiello G (2006) Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Interv Radiol 29:969–974CrossRef Carrafiello G (2006) Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience. Cardiovasc Interv Radiol 29:969–974CrossRef
22.
go back to reference Clevert D-A (2007) Imaging of aortic abnormalities with contrast-enhanced ultrasound. A pictorial comparison with CT. Eur Radiol 17:2991–3000PubMedCrossRef Clevert D-A (2007) Imaging of aortic abnormalities with contrast-enhanced ultrasound. A pictorial comparison with CT. Eur Radiol 17:2991–3000PubMedCrossRef
23.
go back to reference Bilbao JI, Elorz M, Vivas I, et al. (2004) Transjugular intrahepatic portosystemic shunt (TIPS) in the treatment of venous symptomatic chronic portal thrombosis in non-cirrhotic patients. Cardiovasc Interv Radiol 27:474–480CrossRef Bilbao JI, Elorz M, Vivas I, et al. (2004) Transjugular intrahepatic portosystemic shunt (TIPS) in the treatment of venous symptomatic chronic portal thrombosis in non-cirrhotic patients. Cardiovasc Interv Radiol 27:474–480CrossRef
24.
go back to reference Lencioni R (2002) Tissue harmonic and contrast-specific imaging: back to gray scale in ultrasound. Eur Radiol 12:151–165PubMedCrossRef Lencioni R (2002) Tissue harmonic and contrast-specific imaging: back to gray scale in ultrasound. Eur Radiol 12:151–165PubMedCrossRef
25.
go back to reference Lau CT, Scott M, Stavropoulos SW, et al. (2005) Dacron-covered stent-grafts in transjugular intrahepatic portosystemic shunts: initial experience. Radiology 236:725–729PubMedCrossRef Lau CT, Scott M, Stavropoulos SW, et al. (2005) Dacron-covered stent-grafts in transjugular intrahepatic portosystemic shunts: initial experience. Radiology 236:725–729PubMedCrossRef
26.
go back to reference Foshager MC, Ferral H, Finlay DE, et al. (1994) Color Doppler sonography of transjugular intrahepatic portosystemic shunts (TIPS). AJR Am J Roentgenol 163:105–111PubMed Foshager MC, Ferral H, Finlay DE, et al. (1994) Color Doppler sonography of transjugular intrahepatic portosystemic shunts (TIPS). AJR Am J Roentgenol 163:105–111PubMed
27.
go back to reference Uggowitzer MM, Kugler C, Machan L, et al. (1998) Value of echo-enhanced Doppler sonography in evaluation of transjugular intrahepatic portosystemic shunts. AJR Am J Roentgenol 170:1041–1046PubMed Uggowitzer MM, Kugler C, Machan L, et al. (1998) Value of echo-enhanced Doppler sonography in evaluation of transjugular intrahepatic portosystemic shunts. AJR Am J Roentgenol 170:1041–1046PubMed
28.
go back to reference Furst G, Malms J, Heyer T, et al. (1998) Transjugular intrahepatic portosystemic shunts: improved evaluation with echo-enhanced color Doppler sonography, power Doppler sonography, and spectral duplex sonography. AJR Am J Roentgenol 170:1047–1054PubMed Furst G, Malms J, Heyer T, et al. (1998) Transjugular intrahepatic portosystemic shunts: improved evaluation with echo-enhanced color Doppler sonography, power Doppler sonography, and spectral duplex sonography. AJR Am J Roentgenol 170:1047–1054PubMed
29.
go back to reference Phillips P, Gardner E (2004) Contrast-agent detection and quantification. Eur Radiol 14(suppl 8):P4–P10PubMed Phillips P, Gardner E (2004) Contrast-agent detection and quantification. Eur Radiol 14(suppl 8):P4–P10PubMed
30.
go back to reference Martegani A, Aiani L, Borghi C (2004) The use of contrast-enhanced ultrasound in large vessels. Eur Radiol 14(suppl 8):P73–P86PubMed Martegani A, Aiani L, Borghi C (2004) The use of contrast-enhanced ultrasound in large vessels. Eur Radiol 14(suppl 8):P73–P86PubMed
Metadata
Title
Contrast-enhanced ultrasound: a new method for TIPS follow-up
Authors
Capucine Micol
Julien Marsot
Nawele Boublay
Frank Pilleul
Yves Berthezene
Agnès Rode
Publication date
01-04-2012
Publisher
Springer-Verlag
Published in
Abdominal Radiology / Issue 2/2012
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-011-9763-4

Other articles of this Issue 2/2012

Abdominal Radiology 2/2012 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine