Skip to main content
Top
Published in: Neuroradiology 11/2015

01-11-2015 | Diagnostic Neuroradiology

Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

Authors: K. I. Jo, S. R. Kim, J. H. Choi, K. H. Kim, P. Jeon

Published in: Neuroradiology | Issue 11/2015

Login to get access

Abstract

Introduction

Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution.

Methods

A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm3/s (n = 3) and 0.2 cm3/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries.

Results

Flow velocities changed −15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm3/s contrast infusion protocol was better for evaluating the stent and host artery.

Conclusion

Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow.
Literature
1.
go back to reference Clarencon F, Piotin M, Pistocchi S, Babic D, Blanc R (2012) Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms. Neuroradiology 54:1121–1125CrossRefPubMed Clarencon F, Piotin M, Pistocchi S, Babic D, Blanc R (2012) Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms. Neuroradiology 54:1121–1125CrossRefPubMed
2.
go back to reference Hosokawa S, Kawai N, Sato M, Minamiguchi H, Nakai M, Nishioku T, Sonomura T, Matsumoto H, Masuo O, Itakura T (2012) Optimal contrast material concentration for distinguishing among carotid artery lumen, carotid stent, and neck in cone-beam computed tomography during carotid angiography: basic and clinical studies. Jpn J Radiol 30:358–364CrossRefPubMed Hosokawa S, Kawai N, Sato M, Minamiguchi H, Nakai M, Nishioku T, Sonomura T, Matsumoto H, Masuo O, Itakura T (2012) Optimal contrast material concentration for distinguishing among carotid artery lumen, carotid stent, and neck in cone-beam computed tomography during carotid angiography: basic and clinical studies. Jpn J Radiol 30:358–364CrossRefPubMed
3.
go back to reference Patel NV, Gounis MJ, Wakhloo AK, Noordhoek N, Blijd J, Babic D, Takhtani D, Lee SK, Norbash A (2011) Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application. AJNR Am J Neuroradiol 32:137–144PubMed Patel NV, Gounis MJ, Wakhloo AK, Noordhoek N, Blijd J, Babic D, Takhtani D, Lee SK, Norbash A (2011) Contrast-enhanced angiographic cone-beam CT of cerebrovascular stents: experimental optimization and clinical application. AJNR Am J Neuroradiol 32:137–144PubMed
4.
go back to reference Stidd DA, Theessen H, Deng Y, Li Y, Scholz B, Rohkohl C, Jhaveri MD, Moftakhar R, Chen M, Lopes DK (2014) Evaluation of a metal artifacts reduction algorithm applied to postinterventional flat panel detector CT imaging. AJNR Am J Neuroradiol 35:2164–2169CrossRefPubMed Stidd DA, Theessen H, Deng Y, Li Y, Scholz B, Rohkohl C, Jhaveri MD, Moftakhar R, Chen M, Lopes DK (2014) Evaluation of a metal artifacts reduction algorithm applied to postinterventional flat panel detector CT imaging. AJNR Am J Neuroradiol 35:2164–2169CrossRefPubMed
5.
go back to reference Caroff J, Mihalea C, Neki H, Ruijters D, Ikka L, Benachour N, Moret J, Spelle L (2014) Role of C-arm VasoCT in the use of endovascular WEB flow disruption in intracranial aneurysm treatment. AJNR Am J Neuroradiol 35:1353–1357CrossRefPubMed Caroff J, Mihalea C, Neki H, Ruijters D, Ikka L, Benachour N, Moret J, Spelle L (2014) Role of C-arm VasoCT in the use of endovascular WEB flow disruption in intracranial aneurysm treatment. AJNR Am J Neuroradiol 35:1353–1357CrossRefPubMed
6.
go back to reference ElSankari S, Baledent O, van Pesch V, Sindic C, de Broqueville Q, Duprez T (2013) Concomitant analysis of arterial, venous, and CSF flows using phase-contrast MRI: a quantitative comparison between MS patients and healthy controls. J Cereb Blood Flow Metab 33:1314–1321PubMedCentralCrossRefPubMed ElSankari S, Baledent O, van Pesch V, Sindic C, de Broqueville Q, Duprez T (2013) Concomitant analysis of arterial, venous, and CSF flows using phase-contrast MRI: a quantitative comparison between MS patients and healthy controls. J Cereb Blood Flow Metab 33:1314–1321PubMedCentralCrossRefPubMed
7.
go back to reference Radvany MG, Ehtiati T, Huang J, Mahesh M, Gailloud P (2012) Aortic arch injection with C-arm cone beam CT for radiosurgery treatment planning of cerebral arteriovenous malformations: technical note. J Neurointerv Surg 4:e28CrossRefPubMed Radvany MG, Ehtiati T, Huang J, Mahesh M, Gailloud P (2012) Aortic arch injection with C-arm cone beam CT for radiosurgery treatment planning of cerebral arteriovenous malformations: technical note. J Neurointerv Surg 4:e28CrossRefPubMed
8.
go back to reference Pereira VM, Ouared R, Brina O, Bonnefous O, Satwiaski J, Aerts H, Ruijters D, van Nijnatten F, Perren F, Bijlenga P, Schaller K, Lovblad KO (2014) Quantification of internal carotid artery flow with digital subtraction angiography: validation of an optical flow approach with Doppler ultrasound. AJNR Am J Neuroradiol 35:156–163CrossRefPubMed Pereira VM, Ouared R, Brina O, Bonnefous O, Satwiaski J, Aerts H, Ruijters D, van Nijnatten F, Perren F, Bijlenga P, Schaller K, Lovblad KO (2014) Quantification of internal carotid artery flow with digital subtraction angiography: validation of an optical flow approach with Doppler ultrasound. AJNR Am J Neuroradiol 35:156–163CrossRefPubMed
9.
go back to reference Scheel P, Ruge C, Petruch UR, Schoning M (2000) Color duplex measurement of cerebral blood flow volume in healthy adults. Stroke 31:147–150CrossRefPubMed Scheel P, Ruge C, Petruch UR, Schoning M (2000) Color duplex measurement of cerebral blood flow volume in healthy adults. Stroke 31:147–150CrossRefPubMed
10.
go back to reference Dahl A, Russell D, Rootwelt K, Nyberg-Hansen R, Kerty E (1995) Cerebral vasoreactivity assessed with transcranial Doppler and regional cerebral blood flow measurements. Dose, serum concentration, and time course of the response to acetazolamide. Stroke 26:2302–2306CrossRefPubMed Dahl A, Russell D, Rootwelt K, Nyberg-Hansen R, Kerty E (1995) Cerebral vasoreactivity assessed with transcranial Doppler and regional cerebral blood flow measurements. Dose, serum concentration, and time course of the response to acetazolamide. Stroke 26:2302–2306CrossRefPubMed
11.
go back to reference Krejza J, Mariak Z, Babikian VL (2001) Importance of angle correction in the measurement of blood flow velocity with transcranial Doppler sonography. AJNR Am J Neuroradiol 22:1743–1747PubMed Krejza J, Mariak Z, Babikian VL (2001) Importance of angle correction in the measurement of blood flow velocity with transcranial Doppler sonography. AJNR Am J Neuroradiol 22:1743–1747PubMed
12.
go back to reference Manno EM, Gress DR, Schwamm LH, Diringer MN, Ogilvy CS (1998) Effects of induced hypertension on transcranial Doppler ultrasound velocities in patients after subarachnoid hemorrhage. Stroke 29:422–428CrossRefPubMed Manno EM, Gress DR, Schwamm LH, Diringer MN, Ogilvy CS (1998) Effects of induced hypertension on transcranial Doppler ultrasound velocities in patients after subarachnoid hemorrhage. Stroke 29:422–428CrossRefPubMed
13.
go back to reference Uematsu S, Yang A, Preziosi TJ, Kouba R, Toung TJ (1983) Measurement of carotid blood flow in man and its clinical application. Stroke 14:256–266CrossRefPubMed Uematsu S, Yang A, Preziosi TJ, Kouba R, Toung TJ (1983) Measurement of carotid blood flow in man and its clinical application. Stroke 14:256–266CrossRefPubMed
Metadata
Title
Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium
Authors
K. I. Jo
S. R. Kim
J. H. Choi
K. H. Kim
P. Jeon
Publication date
01-11-2015
Publisher
Springer Berlin Heidelberg
Published in
Neuroradiology / Issue 11/2015
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-015-1570-0

Other articles of this Issue 11/2015

Neuroradiology 11/2015 Go to the issue