Skip to main content
Top
Published in: Current Dermatology Reports 1/2017

01-03-2017 | Hospital- based Dermatology (D Kroshinsky, Section Editor)

Contact Dermatitis in the Hospitalized Patient

Authors: Ilka Arun Netravali, Sarina B. Elmariah

Published in: Current Dermatology Reports | Issue 1/2017

Login to get access

Abstract

Purpose of Review

The purpose of this study is to review the pathophysiology, clinical presentation, and management strategies for irritant and allergic contact dermatitis (CD) in hospitalized patients.

Recent Findings

Contact dermatitis accounts for 10% of inpatient dermatology consult cases. This high frequency of CD arises because hospitalized patients are exposed to numerous irritants and common allergens as part of diagnostic and therapeutic procedures. Common triggers include antibiotics, antiseptics, anesthetics, latex, and rubber additives. Hypersensitivity to metals and other materials in cardiac and orthopedic implants has also been reported, and an association between CD and implant failure has been proposed.

Summary

Recognition of CD and identification of the causative agent require a detailed clinical and exposure history, physical exam, and a high degree of clinical suspicion. Timely diagnosis and management are crucial, as they enable symptom relief and improvement in quality of life, and may also positively impact overall health outcomes by reducing associated systemic morbidity.
Literature
1.
go back to reference Galimberti F, et al. Dermatology consultations significantly contribute quality to care of hospitalized patients: a prospective study of dermatology inpatient consults at a tertiary care center. Int J Dermatol. 2016;55(10):e547–51.PubMedCrossRef Galimberti F, et al. Dermatology consultations significantly contribute quality to care of hospitalized patients: a prospective study of dermatology inpatient consults at a tertiary care center. Int J Dermatol. 2016;55(10):e547–51.PubMedCrossRef
2.
go back to reference Storan ER, et al. Pediatric hospital dermatology: experience with inpatient and consult services at the Mayo Clinic. Pediatr Dermatol. 2013;30(4):433–7.PubMedCrossRef Storan ER, et al. Pediatric hospital dermatology: experience with inpatient and consult services at the Mayo Clinic. Pediatr Dermatol. 2013;30(4):433–7.PubMedCrossRef
3.
go back to reference Divkovic M, et al. Hapten-protein binding: from theory to practical application in the in vitro prediction of skin sensitization. Contact Dermatitis. 2005;53(4):189–200.PubMedCrossRef Divkovic M, et al. Hapten-protein binding: from theory to practical application in the in vitro prediction of skin sensitization. Contact Dermatitis. 2005;53(4):189–200.PubMedCrossRef
4.
go back to reference Mowad CM, et al. Allergic contact dermatitis: patient diagnosis and evaluation. J Am Acad Dermatol. 2016;74(6):1029–40.PubMedCrossRef Mowad CM, et al. Allergic contact dermatitis: patient diagnosis and evaluation. J Am Acad Dermatol. 2016;74(6):1029–40.PubMedCrossRef
5.
go back to reference Trautmann A, et al. The differential fate of cadherins during T-cell-induced keratinocyte apoptosis leads to spongiosis in eczematous dermatitis. J Invest Dermatol. 2001;117(4):927–34.PubMedCrossRef Trautmann A, et al. The differential fate of cadherins during T-cell-induced keratinocyte apoptosis leads to spongiosis in eczematous dermatitis. J Invest Dermatol. 2001;117(4):927–34.PubMedCrossRef
6.
go back to reference Widman TJ, Oostman H, Storrs FJ. Allergic contact dermatitis from medical adhesive bandages in patients who report having a reaction to medical bandages. Dermatitis. 2008;19(1):32–7.PubMed Widman TJ, Oostman H, Storrs FJ. Allergic contact dermatitis from medical adhesive bandages in patients who report having a reaction to medical bandages. Dermatitis. 2008;19(1):32–7.PubMed
7.
8.
go back to reference Hivnor CM, Hudkins ML. Allergic contact dermatitis after postsurgical repair with 2-octylcyanoacrylate. Arch Dermatol. 2008;144(6):814–5.PubMedCrossRef Hivnor CM, Hudkins ML. Allergic contact dermatitis after postsurgical repair with 2-octylcyanoacrylate. Arch Dermatol. 2008;144(6):814–5.PubMedCrossRef
9.
go back to reference Connolly M, Buckley DA. Contact dermatitis from propylene glycol in ECG electrodes, complicated by medicament allergy. Contact Dermatitis. 2004;50(1):42.PubMedCrossRef Connolly M, Buckley DA. Contact dermatitis from propylene glycol in ECG electrodes, complicated by medicament allergy. Contact Dermatitis. 2004;50(1):42.PubMedCrossRef
10.
go back to reference Ozkaya E, Kavlak Bozkurt P. Allergic contact dermatitis caused by self-adhesive electrocardiography electrodes: a rare case with concomitant roles of nickel and acrylates. Contact Dermatitis. 2014;70(2):121–3.PubMedCrossRef Ozkaya E, Kavlak Bozkurt P. Allergic contact dermatitis caused by self-adhesive electrocardiography electrodes: a rare case with concomitant roles of nickel and acrylates. Contact Dermatitis. 2014;70(2):121–3.PubMedCrossRef
11.
go back to reference Marks Jr JG, Rainey MA. Cutaneous reactions to surgical preparations and dressings. Contact Dermatitis. 1984;10(1):1–5.PubMedCrossRef Marks Jr JG, Rainey MA. Cutaneous reactions to surgical preparations and dressings. Contact Dermatitis. 1984;10(1):1–5.PubMedCrossRef
12.
go back to reference Green CM, Holden CR, Gawkrodger DJ. Contact allergy to topical medicaments becomes more common with advancing age: an age-stratified study. Contact Dermatitis. 2007;56(4):229–31.PubMedCrossRef Green CM, Holden CR, Gawkrodger DJ. Contact allergy to topical medicaments becomes more common with advancing age: an age-stratified study. Contact Dermatitis. 2007;56(4):229–31.PubMedCrossRef
13.
go back to reference Menezes de Padua CA, et al. Contact allergy to neomycin sulfate: results of a multifactorial analysis. Pharmacoepidemiol Drug Saf. 2005;14(10):725–33.PubMedCrossRef Menezes de Padua CA, et al. Contact allergy to neomycin sulfate: results of a multifactorial analysis. Pharmacoepidemiol Drug Saf. 2005;14(10):725–33.PubMedCrossRef
14.
go back to reference Gehrig KA, Warshaw EM. Allergic contact dermatitis to topical antibiotics: epidemiology, responsible allergens, and management. J Am Acad Dermatol. 2008;58(1):1–21.PubMedCrossRef Gehrig KA, Warshaw EM. Allergic contact dermatitis to topical antibiotics: epidemiology, responsible allergens, and management. J Am Acad Dermatol. 2008;58(1):1–21.PubMedCrossRef
15.
16.
go back to reference Lerman SJ. Letter: why not use topical penicillin? Pediatrics. 1976;58(2):302.PubMed Lerman SJ. Letter: why not use topical penicillin? Pediatrics. 1976;58(2):302.PubMed
17.
go back to reference Andre MC, et al. Systemic contact allergy to penicillin after prick and intradermal tests. Ann Allergy Asthma Immunol. 2011;106(2):174–5.PubMedCrossRef Andre MC, et al. Systemic contact allergy to penicillin after prick and intradermal tests. Ann Allergy Asthma Immunol. 2011;106(2):174–5.PubMedCrossRef
18.
go back to reference Rietschel RL, Fowler JF, Fisher AA. Topical antimicrobials. Fisher’s contact dermatitis. Hamilton, Ontario: BC Decker; 2008. Rietschel RL, Fowler JF, Fisher AA. Topical antimicrobials. Fisher’s contact dermatitis. Hamilton, Ontario: BC Decker; 2008.
19.
go back to reference Trookman NS, Rizer RL, Weber T. Irritation and allergy patch test analysis of topical treatments commonly used in wound care: evaluation on normal and compromised skin. J Am Acad Dermatol. 2011;64(3 Suppl):S16–22.PubMedCrossRef Trookman NS, Rizer RL, Weber T. Irritation and allergy patch test analysis of topical treatments commonly used in wound care: evaluation on normal and compromised skin. J Am Acad Dermatol. 2011;64(3 Suppl):S16–22.PubMedCrossRef
20.
go back to reference Pratt MD, et al. North American Contact Dermatitis Group patch-test results, 2001-2002 study period. Dermatitis. 2004;15(4):176–83.PubMed Pratt MD, et al. North American Contact Dermatitis Group patch-test results, 2001-2002 study period. Dermatitis. 2004;15(4):176–83.PubMed
21.
go back to reference Goh CL. Contact sensitivity to topical antimicrobials. (II). Sensitizing potentials of some topical antimicrobials. Contact Dermatitis. 1989;21(3):166–71.PubMedCrossRef Goh CL. Contact sensitivity to topical antimicrobials. (II). Sensitizing potentials of some topical antimicrobials. Contact Dermatitis. 1989;21(3):166–71.PubMedCrossRef
22.
go back to reference Guin JD, Phillips D. Erythroderma from systemic contact dermatitis: a complication of systemic gentamicin in a patient with contact allergy to neomycin. Cutis. 1989;43(6):564–7.PubMed Guin JD, Phillips D. Erythroderma from systemic contact dermatitis: a complication of systemic gentamicin in a patient with contact allergy to neomycin. Cutis. 1989;43(6):564–7.PubMed
23.
go back to reference Marks Jr JG, et al. North American Contact Dermatitis Group patch-test results, 1996-1998. Arch Dermatol. 2000;136(2):272–3.PubMedCrossRef Marks Jr JG, et al. North American Contact Dermatitis Group patch-test results, 1996-1998. Arch Dermatol. 2000;136(2):272–3.PubMedCrossRef
24.
go back to reference Marks Jr JG, et al. North American Contact Dermatitis Group patch-test results, 1998 to 2000. Am J Contact Dermat. 2003;14(2):59–62.PubMedCrossRef Marks Jr JG, et al. North American Contact Dermatitis Group patch-test results, 1998 to 2000. Am J Contact Dermat. 2003;14(2):59–62.PubMedCrossRef
25.
go back to reference Gette MT, Marks Jr JG, Maloney ME. Frequency of postoperative allergic contact dermatitis to topical antibiotics. Arch Dermatol. 1992;128(3):365–7.PubMedCrossRef Gette MT, Marks Jr JG, Maloney ME. Frequency of postoperative allergic contact dermatitis to topical antibiotics. Arch Dermatol. 1992;128(3):365–7.PubMedCrossRef
26.
go back to reference Alfalah M, et al. Contact allergy to polymyxin B among patients referred for patch testing. Dermatitis. 2016;27(3):119–22.PubMedCrossRef Alfalah M, et al. Contact allergy to polymyxin B among patients referred for patch testing. Dermatitis. 2016;27(3):119–22.PubMedCrossRef
27.
go back to reference Zaki I, Shall L, Dalziel KL. Bacitracin: a significant sensitizer in leg ulcer patients? Contact Dermatitis. 1994;31(2):92–4.PubMedCrossRef Zaki I, Shall L, Dalziel KL. Bacitracin: a significant sensitizer in leg ulcer patients? Contact Dermatitis. 1994;31(2):92–4.PubMedCrossRef
28.
go back to reference Draelos ZD, Rizer RL, Trookman NS. A comparison of postprocedural wound care treatments: do antibiotic-based ointments improve outcomes? J Am Acad Dermatol. 2011;64(3 Suppl):S23–9.PubMedCrossRef Draelos ZD, Rizer RL, Trookman NS. A comparison of postprocedural wound care treatments: do antibiotic-based ointments improve outcomes? J Am Acad Dermatol. 2011;64(3 Suppl):S23–9.PubMedCrossRef
29.
go back to reference • Lachapelle JM. A comparison of the irritant and allergenic properties of antiseptics. Eur J Dermatol. 2014;24(1):3–9. This study provides a review of the irritant and allergenic properties of current and frequently used antiseptic therapies, including a summary of their mechanisms of action and the most current safety data available to date. PubMed • Lachapelle JM. A comparison of the irritant and allergenic properties of antiseptics. Eur J Dermatol. 2014;24(1):3–9. This study provides a review of the irritant and allergenic properties of current and frequently used antiseptic therapies, including a summary of their mechanisms of action and the most current safety data available to date. PubMed
30.
go back to reference Hannuksela M, Salo H. The repeated open application test (ROAT). Contact Dermatitis. 1986;14(4):221–7.PubMedCrossRef Hannuksela M, Salo H. The repeated open application test (ROAT). Contact Dermatitis. 1986;14(4):221–7.PubMedCrossRef
31.
go back to reference Cheng CE, Kroshinsky D. Iatrogenic skin injury in hospitalized patients. Clin Dermatol. 2011;29(6):622–32.PubMedCrossRef Cheng CE, Kroshinsky D. Iatrogenic skin injury in hospitalized patients. Clin Dermatol. 2011;29(6):622–32.PubMedCrossRef
32.
go back to reference Iijima S, Kuramochi M. Investigation of irritant skin reaction by 10% povidone-iodine solution after surgery. Dermatology. 2002;204(Suppl 1):103–8.PubMedCrossRef Iijima S, Kuramochi M. Investigation of irritant skin reaction by 10% povidone-iodine solution after surgery. Dermatology. 2002;204(Suppl 1):103–8.PubMedCrossRef
33.
go back to reference Liippo J, Kousa P, Lammintausta K. The relevance of chlorhexidine contact allergy. Contact Dermatitis. 2011;64(4):229–34.PubMedCrossRef Liippo J, Kousa P, Lammintausta K. The relevance of chlorhexidine contact allergy. Contact Dermatitis. 2011;64(4):229–34.PubMedCrossRef
34.
go back to reference Perrenoud D, et al. Frequency of sensitization to 13 common preservatives in Switzerland. Swiss Contact Dermatitis Research Group. Contact Dermatitis. 1994;30(5):276–9.PubMedCrossRef Perrenoud D, et al. Frequency of sensitization to 13 common preservatives in Switzerland. Swiss Contact Dermatitis Research Group. Contact Dermatitis. 1994;30(5):276–9.PubMedCrossRef
35.
go back to reference Mailhol C, et al. Prevalence and risk factors for allergic contact dermatitis to topical treatment in atopic dermatitis: a study in 641 children. Allergy. 2009;64(5):801–6.PubMedCrossRef Mailhol C, et al. Prevalence and risk factors for allergic contact dermatitis to topical treatment in atopic dermatitis: a study in 641 children. Allergy. 2009;64(5):801–6.PubMedCrossRef
36.
go back to reference Weitz NA, et al. Chlorhexidine gluconate-impregnated central access catheter dressings as a cause of erosive contact dermatitis: a report of 7 cases. JAMA Dermatol. 2013;149(2):195–9.PubMedCrossRef Weitz NA, et al. Chlorhexidine gluconate-impregnated central access catheter dressings as a cause of erosive contact dermatitis: a report of 7 cases. JAMA Dermatol. 2013;149(2):195–9.PubMedCrossRef
37.
38.
go back to reference Garcia AA, et al. Allergic contact dermatitis to silver in a patient treated with silver sulphadiazine after a burn. J Eur Acad Dermatol Venereol. 2016;30(2):365–6.PubMedCrossRef Garcia AA, et al. Allergic contact dermatitis to silver in a patient treated with silver sulphadiazine after a burn. J Eur Acad Dermatol Venereol. 2016;30(2):365–6.PubMedCrossRef
39.
go back to reference McKenna SR, et al. Serious silver sulphadiazine and mafenide acetate dermatitis. Burns. 1995;21(4):310–2.PubMedCrossRef McKenna SR, et al. Serious silver sulphadiazine and mafenide acetate dermatitis. Burns. 1995;21(4):310–2.PubMedCrossRef
40.
go back to reference Fraser-Moodie A. Sensitivity to silver in a patient treated with silver sulphadiazine (Flamazine). Burns. 1992;18(1):74–5.PubMedCrossRef Fraser-Moodie A. Sensitivity to silver in a patient treated with silver sulphadiazine (Flamazine). Burns. 1992;18(1):74–5.PubMedCrossRef
41.
go back to reference To D, Kossintseva I, de Gannes G. Lidocaine contact allergy is becoming more prevalent. Dermatol Surg. 2014;40(12):1367–72.PubMedCrossRef To D, Kossintseva I, de Gannes G. Lidocaine contact allergy is becoming more prevalent. Dermatol Surg. 2014;40(12):1367–72.PubMedCrossRef
42.
go back to reference Kluger N, et al. Acute bullous irritant contact dermatitis caused by EMLA(R) cream. Contact Dermatitis. 2011;65(3):181–3.PubMedCrossRef Kluger N, et al. Acute bullous irritant contact dermatitis caused by EMLA(R) cream. Contact Dermatitis. 2011;65(3):181–3.PubMedCrossRef
43.
go back to reference Yuen WY, et al. Bullous allergic contact dermatitis to lidocaine. Contact Dermatitis. 2009;61(5):300–1.PubMedCrossRef Yuen WY, et al. Bullous allergic contact dermatitis to lidocaine. Contact Dermatitis. 2009;61(5):300–1.PubMedCrossRef
44.
go back to reference Melamed J, Beaucher WN. Delayed-type hypersensitivity (type IV) reactions in dental anesthesia. Allergy Asthma Proc. 2007;28(4):477–9.PubMedCrossRef Melamed J, Beaucher WN. Delayed-type hypersensitivity (type IV) reactions in dental anesthesia. Allergy Asthma Proc. 2007;28(4):477–9.PubMedCrossRef
45.
go back to reference Brinca A, Cabral R, Goncalo M. Contact allergy to local anaesthetics—value of patch testing with a caine mix in the baseline series. Contact Dermatitis. 2013;68(3):156–62.PubMedCrossRef Brinca A, Cabral R, Goncalo M. Contact allergy to local anaesthetics—value of patch testing with a caine mix in the baseline series. Contact Dermatitis. 2013;68(3):156–62.PubMedCrossRef
46.
go back to reference Warshaw EM, et al. North American Contact Dermatitis Group patch test results: 2009 to 2010. Dermatitis. 2013;24(2):50–9.PubMedCrossRef Warshaw EM, et al. North American Contact Dermatitis Group patch test results: 2009 to 2010. Dermatitis. 2013;24(2):50–9.PubMedCrossRef
47.
go back to reference Amado A, Sood A, Taylor JS. Contact allergy to lidocaine: a report of sixteen cases. Dermatitis. 2007;18(4):215–20.PubMedCrossRef Amado A, Sood A, Taylor JS. Contact allergy to lidocaine: a report of sixteen cases. Dermatitis. 2007;18(4):215–20.PubMedCrossRef
48.
go back to reference Fisher AA. Reactions to injectable local anesthetics. Part IV: reactions to sulfites in local anesthetics. Cutis. 1989;44(4):283–4.PubMed Fisher AA. Reactions to injectable local anesthetics. Part IV: reactions to sulfites in local anesthetics. Cutis. 1989;44(4):283–4.PubMed
49.
go back to reference Dooms-Goossens A, et al. Local anesthetic intolerance due to metabisulfite. Contact Dermatitis. 1989;20(2):124–6.PubMedCrossRef Dooms-Goossens A, et al. Local anesthetic intolerance due to metabisulfite. Contact Dermatitis. 1989;20(2):124–6.PubMedCrossRef
51.
go back to reference Raap U, et al. Allergic contact dermatitis to acid blue 158 in suture material. Contact Dermatitis. 2008;59(3):192–3.PubMedCrossRef Raap U, et al. Allergic contact dermatitis to acid blue 158 in suture material. Contact Dermatitis. 2008;59(3):192–3.PubMedCrossRef
52.
go back to reference Della Torre F, Della Torre E, Di Berardino F. Side effects from polydioxanone. Eur Ann Allergy Clin Immunol. 2005;37(2):47–8.PubMed Della Torre F, Della Torre E, Di Berardino F. Side effects from polydioxanone. Eur Ann Allergy Clin Immunol. 2005;37(2):47–8.PubMed
53.
go back to reference Dagregorio G, Guillet G. Allergic suture material contact dermatitis induced by ethylene oxide. Allergy. 2004;59(11):1239.PubMedCrossRef Dagregorio G, Guillet G. Allergic suture material contact dermatitis induced by ethylene oxide. Allergy. 2004;59(11):1239.PubMedCrossRef
54.
go back to reference Klein CE, Gall H. Type IV allergy to amide-type local anesthetics. Contact Dermatitis. 1991;25(1):45–8.PubMedCrossRef Klein CE, Gall H. Type IV allergy to amide-type local anesthetics. Contact Dermatitis. 1991;25(1):45–8.PubMedCrossRef
55.
go back to reference Curley RK, Macfarlane AW, King CM. Contact sensitivity to the amide anesthetics lidocaine, prilocaine, and mepivacaine. Case report and review of the literature. Arch Dermatol. 1986;122(8):924–6.PubMedCrossRef Curley RK, Macfarlane AW, King CM. Contact sensitivity to the amide anesthetics lidocaine, prilocaine, and mepivacaine. Case report and review of the literature. Arch Dermatol. 1986;122(8):924–6.PubMedCrossRef
56.
go back to reference Jussi L, Lammintausta K. Sources of sensitization, cross-reactions, and occupational sensitization to topical anaesthetics among general dermatology patients. Contact Dermatitis. 2009;60(3):150–4.PubMedCrossRef Jussi L, Lammintausta K. Sources of sensitization, cross-reactions, and occupational sensitization to topical anaesthetics among general dermatology patients. Contact Dermatitis. 2009;60(3):150–4.PubMedCrossRef
57.
go back to reference Ramirez P, et al. Allergic contact dermatitis from antihemorrhoidal ointments: concomitant sensitization to both amide and ester local anesthetics. Dermatitis. 2010;21(3):176–7.PubMed Ramirez P, et al. Allergic contact dermatitis from antihemorrhoidal ointments: concomitant sensitization to both amide and ester local anesthetics. Dermatitis. 2010;21(3):176–7.PubMed
58.
go back to reference • Burkhart C, Schloemer J, Zirwas M. Differentiation of latex allergy from irritant contact dermatitis. Cutis. 2015;96(6):369-71–401. This study provides an indepth discussion of the three primary mechanisms by which individuals develop adverse reactions to latex-containing products, including irritant reactions as well as immediate and delayed-type hypersensitivity reactions. • Burkhart C, Schloemer J, Zirwas M. Differentiation of latex allergy from irritant contact dermatitis. Cutis. 2015;96(6):369-71–401. This study provides an indepth discussion of the three primary mechanisms by which individuals develop adverse reactions to latex-containing products, including irritant reactions as well as immediate and delayed-type hypersensitivity reactions.
60.
go back to reference Higgins CL, et al. Occupational skin disease among Australian healthcare workers: a retrospective analysis from an occupational dermatology clinic, 1993-2014. Contact Dermatitis. 2016;75(4):213–22.PubMedCrossRef Higgins CL, et al. Occupational skin disease among Australian healthcare workers: a retrospective analysis from an occupational dermatology clinic, 1993-2014. Contact Dermatitis. 2016;75(4):213–22.PubMedCrossRef
61.
go back to reference Wu M, McIntosh J, Liu J. Current prevalence rate of latex allergy: why it remains a problem? J Occup Health. 2016;58(2):138–44.PubMedCrossRef Wu M, McIntosh J, Liu J. Current prevalence rate of latex allergy: why it remains a problem? J Occup Health. 2016;58(2):138–44.PubMedCrossRef
63.
go back to reference Hepner DL, Castells MC. Anaphylaxis during the perioperative period. Anesth Analg. 2003;97(5):1381–95.PubMedCrossRef Hepner DL, Castells MC. Anaphylaxis during the perioperative period. Anesth Analg. 2003;97(5):1381–95.PubMedCrossRef
64.
go back to reference Kwittken PL, et al. Latex hypersensitivity in children: clinical presentation and detection of latex-specific immunoglobulin E. Pediatrics. 1995;95(5):693–9.PubMed Kwittken PL, et al. Latex hypersensitivity in children: clinical presentation and detection of latex-specific immunoglobulin E. Pediatrics. 1995;95(5):693–9.PubMed
65.
go back to reference Nettis E, et al. Type I allergy to natural rubber latex and type IV allergy to rubber chemicals in health care workers with glove-related skin symptoms. Clin Exp Allergy. 2002;32(3):441–7.PubMedCrossRef Nettis E, et al. Type I allergy to natural rubber latex and type IV allergy to rubber chemicals in health care workers with glove-related skin symptoms. Clin Exp Allergy. 2002;32(3):441–7.PubMedCrossRef
66.
go back to reference Warburton KL, et al. ESSCA results with the baseline series, 2009-2012: rubber allergens. Contact Dermatitis. 2015;73(5):305–12.PubMedCrossRef Warburton KL, et al. ESSCA results with the baseline series, 2009-2012: rubber allergens. Contact Dermatitis. 2015;73(5):305–12.PubMedCrossRef
67.
go back to reference Mitchell KA, et al. Demographic, clinical, and quality of life variables related to embarrassment in veterans living with an intestinal stoma. J Wound Ostomy Continence Nurs. 2007;34(5):524–32.PubMedCrossRef Mitchell KA, et al. Demographic, clinical, and quality of life variables related to embarrassment in veterans living with an intestinal stoma. J Wound Ostomy Continence Nurs. 2007;34(5):524–32.PubMedCrossRef
68.
go back to reference Lyon CC, et al. Peristomal dermatoses: a novel indication for topical steroid lotions. J Am Acad Dermatol. 2000;43(4):679–82.PubMedCrossRef Lyon CC, et al. Peristomal dermatoses: a novel indication for topical steroid lotions. J Am Acad Dermatol. 2000;43(4):679–82.PubMedCrossRef
69.
go back to reference Burch J, Sica J. Common peristomal skin problems and potential treatment options. Br J Nurs. 2008;17(17):S4–6. S8 passimPubMedCrossRef Burch J, Sica J. Common peristomal skin problems and potential treatment options. Br J Nurs. 2008;17(17):S4–6. S8 passimPubMedCrossRef
70.
go back to reference Hellman J, Lago CP. Dermatologic complications in colostomy and ileostomy patients. Int J Dermatol. 1990;29(2):129–33.PubMedCrossRef Hellman J, Lago CP. Dermatologic complications in colostomy and ileostomy patients. Int J Dermatol. 1990;29(2):129–33.PubMedCrossRef
71.
go back to reference Lyon CC, et al. The spectrum of skin disorders in abdominal stoma patients. Br J Dermatol. 2000;143(6):1248–60.PubMedCrossRef Lyon CC, et al. The spectrum of skin disorders in abdominal stoma patients. Br J Dermatol. 2000;143(6):1248–60.PubMedCrossRef
72.
go back to reference Rolstad BS, Erwin-Toth PL. Peristomal skin complications: prevention and management. Ostomy Wound Manage. 2004;50(9):68–77.PubMed Rolstad BS, Erwin-Toth PL. Peristomal skin complications: prevention and management. Ostomy Wound Manage. 2004;50(9):68–77.PubMed
73.
go back to reference Mann RJ, Stewart E, Peachey RD. Sensitivity to urostomy pouch plastic. Contact Dermatitis. 1983;9(1):80–1.PubMedCrossRef Mann RJ, Stewart E, Peachey RD. Sensitivity to urostomy pouch plastic. Contact Dermatitis. 1983;9(1):80–1.PubMedCrossRef
74.
go back to reference Fregert S, Meding B, Trulsson L. Demonstration of epoxy resin in stoma pouch plastic. Contact Dermatitis. 1984;10(2):106.PubMedCrossRef Fregert S, Meding B, Trulsson L. Demonstration of epoxy resin in stoma pouch plastic. Contact Dermatitis. 1984;10(2):106.PubMedCrossRef
75.
go back to reference Beck MH, et al. Allergic contact dermatitis to epoxy resin in ostomy bags. Br J Surg. 1985;72(3):202–3.PubMedCrossRef Beck MH, et al. Allergic contact dermatitis to epoxy resin in ostomy bags. Br J Surg. 1985;72(3):202–3.PubMedCrossRef
76.
go back to reference Camarasa JM, Alomar A. Contact dermatitis from a Karaya seal ring. Contact Dermatitis. 1980;6(2):139–40.PubMedCrossRef Camarasa JM, Alomar A. Contact dermatitis from a Karaya seal ring. Contact Dermatitis. 1980;6(2):139–40.PubMedCrossRef
77.
go back to reference Scalf LA, Fowler Jr JF. Peristomal allergic contact dermatitis due to Gantrez in Stomahesive paste. J Am Acad Dermatol. 2000;42(2 Pt 2):355–6.PubMedCrossRef Scalf LA, Fowler Jr JF. Peristomal allergic contact dermatitis due to Gantrez in Stomahesive paste. J Am Acad Dermatol. 2000;42(2 Pt 2):355–6.PubMedCrossRef
78.
go back to reference Martin JA, Hughes TM, Stone NM. Peristomal allergic contact dermatitis—case report and review of the literature. Contact Dermatitis. 2005;52(5):273–5.PubMedCrossRef Martin JA, Hughes TM, Stone NM. Peristomal allergic contact dermatitis—case report and review of the literature. Contact Dermatitis. 2005;52(5):273–5.PubMedCrossRef
79.
go back to reference Davids MG, Hodgson GA, Evans E. Contact dermatitis from an ostomy deodorant. Contact Dermatitis. 1978;4(1):11–3.PubMedCrossRef Davids MG, Hodgson GA, Evans E. Contact dermatitis from an ostomy deodorant. Contact Dermatitis. 1978;4(1):11–3.PubMedCrossRef
80.
go back to reference Lazarov A, Trattner A. Allergic contact dermatitis from the adhesive remover wipe of stoma bags. Contact Dermatitis. 1998;39(1):48–9.PubMedCrossRef Lazarov A, Trattner A. Allergic contact dermatitis from the adhesive remover wipe of stoma bags. Contact Dermatitis. 1998;39(1):48–9.PubMedCrossRef
81.
go back to reference Fernandez-Redondo V, et al. Allergic contact dermatitis from local anaesthetic on peristomal skin. Contact Dermatitis. 2001;45(6):358.PubMedCrossRef Fernandez-Redondo V, et al. Allergic contact dermatitis from local anaesthetic on peristomal skin. Contact Dermatitis. 2001;45(6):358.PubMedCrossRef
82.
go back to reference Nybaek H, et al. Skin problems in ostomy patients: a case-control study of risk factors. Acta Derm Venereol. 2009;89(1):64–7.PubMedCrossRef Nybaek H, et al. Skin problems in ostomy patients: a case-control study of risk factors. Acta Derm Venereol. 2009;89(1):64–7.PubMedCrossRef
83.
go back to reference Smith AJ, Lyon CC, Hart CA. Multidisciplinary care of skin problems in stoma patients. Br J Nurs. 2002;11(5):324–30.PubMedCrossRef Smith AJ, Lyon CC, Hart CA. Multidisciplinary care of skin problems in stoma patients. Br J Nurs. 2002;11(5):324–30.PubMedCrossRef
84.
go back to reference • Aquino M, Mucci T. Systemic contact dermatitis and allergy to biomedical devices. Curr Allergy Asthma Rep. 2013;13(5):518–27. This review provides an extensive discussion of the many causes of systemic contact dermatitis with an indepth focus on metal allergies including a summary of the existing literature discussing reactions to implanted cardiac, orthopedic, gynecologic, and dental devices. PubMedCrossRef • Aquino M, Mucci T. Systemic contact dermatitis and allergy to biomedical devices. Curr Allergy Asthma Rep. 2013;13(5):518–27. This review provides an extensive discussion of the many causes of systemic contact dermatitis with an indepth focus on metal allergies including a summary of the existing literature discussing reactions to implanted cardiac, orthopedic, gynecologic, and dental devices. PubMedCrossRef
85.
go back to reference Dorr LD, et al. Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty. Clin Orthop Relat Res. 1990;261:82–95. Dorr LD, et al. Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty. Clin Orthop Relat Res. 1990;261:82–95.
86.
go back to reference Jacobs JJ, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am. 1998;80(10):1447–58.PubMedCrossRef Jacobs JJ, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am. 1998;80(10):1447–58.PubMedCrossRef
87.
go back to reference Honari G, et al. Hypersensitivity reactions associated with endovascular devices. Contact Dermatitis. 2008;59(1):7–22.PubMedCrossRef Honari G, et al. Hypersensitivity reactions associated with endovascular devices. Contact Dermatitis. 2008;59(1):7–22.PubMedCrossRef
88.
go back to reference Iijima R, et al. The impact of metallic allergy on stent implantation: metal allergy and recurrence of in-stent restenosis. Int J Cardiol. 2005;104(3):319–25.PubMedCrossRef Iijima R, et al. The impact of metallic allergy on stent implantation: metal allergy and recurrence of in-stent restenosis. Int J Cardiol. 2005;104(3):319–25.PubMedCrossRef
89.
go back to reference Koster R, et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet. 2000;356(9245):1895–7.PubMedCrossRef Koster R, et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet. 2000;356(9245):1895–7.PubMedCrossRef
90.
go back to reference Norgaz T, et al. Is there a link between nickel allergy and coronary stent restenosis? Tohoku J Exp Med. 2005;206(3):243–6.PubMedCrossRef Norgaz T, et al. Is there a link between nickel allergy and coronary stent restenosis? Tohoku J Exp Med. 2005;206(3):243–6.PubMedCrossRef
91.
go back to reference Saito T, et al. Metal allergic reaction in chronic refractory in-stent restenosis. Cardiovasc Revasc Med. 2009;10(1):17–22.PubMedCrossRef Saito T, et al. Metal allergic reaction in chronic refractory in-stent restenosis. Cardiovasc Revasc Med. 2009;10(1):17–22.PubMedCrossRef
92.
go back to reference Svedman C, et al. Contact allergy to gold in patients with gold-plated intracoronary stents. Contact Dermatitis. 2005;52(4):192–6.PubMedCrossRef Svedman C, et al. Contact allergy to gold in patients with gold-plated intracoronary stents. Contact Dermatitis. 2005;52(4):192–6.PubMedCrossRef
93.
go back to reference Ekqvist S, et al. High frequency of contact allergy to gold in patients with endovascular coronary stents. Br J Dermatol. 2007;157(4):730–8.PubMedCrossRef Ekqvist S, et al. High frequency of contact allergy to gold in patients with endovascular coronary stents. Br J Dermatol. 2007;157(4):730–8.PubMedCrossRef
94.
go back to reference Ishii K, et al. Pacemaker contact dermatitis: the effective use of a polytetrafluoroethylene sheet. Pacing Clin Electrophysiol. 2006;29(11):1299–302.PubMedCrossRef Ishii K, et al. Pacemaker contact dermatitis: the effective use of a polytetrafluoroethylene sheet. Pacing Clin Electrophysiol. 2006;29(11):1299–302.PubMedCrossRef
95.
go back to reference Oprea ML, et al. Allergy to pacemaker silicone compounds: recognition and surgical management. Ann Thorac Surg. 2009;87(4):1275–7.PubMedCrossRef Oprea ML, et al. Allergy to pacemaker silicone compounds: recognition and surgical management. Ann Thorac Surg. 2009;87(4):1275–7.PubMedCrossRef
96.
go back to reference Raque C, Goldschmidt H. Dermatitis associated with an implanted cardiac pacemaker. Arch Dermatol. 1970;102(6):646–9.PubMedCrossRef Raque C, Goldschmidt H. Dermatitis associated with an implanted cardiac pacemaker. Arch Dermatol. 1970;102(6):646–9.PubMedCrossRef
97.
go back to reference Williams SN, Wolford ML, Bercovitz A. Hospitalization for total knee replacement among inpatients aged 45 and over: United States. NCHS Data Brief. 2000-2010;2015(210):1–8. Williams SN, Wolford ML, Bercovitz A. Hospitalization for total knee replacement among inpatients aged 45 and over: United States. NCHS Data Brief. 2000-2010;2015(210):1–8.
98.
go back to reference Wolford ML, Palso K, Bercovitz A. Hospitalization for total hip replacement among inpatients aged 45 and over: United States. NCHS Data Brief. 2000-2010;2015(186):1–8. Wolford ML, Palso K, Bercovitz A. Hospitalization for total hip replacement among inpatients aged 45 and over: United States. NCHS Data Brief. 2000-2010;2015(186):1–8.
99.
go back to reference Kurtz S, et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780–5.PubMed Kurtz S, et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89(4):780–5.PubMed
100.
go back to reference Thyssen JP, et al. Hypersensitivity reactions from metallic implants: a future challenge that needs to be addressed. Br J Dermatol. 2010;162(2):235–6.PubMedCrossRef Thyssen JP, et al. Hypersensitivity reactions from metallic implants: a future challenge that needs to be addressed. Br J Dermatol. 2010;162(2):235–6.PubMedCrossRef
102.
go back to reference Tilsley DA, Rotstein H. Sensitivity caused by internal exposure to nickel, chrome and cobalt. Contact Dermatitis. 1980;6(3):175–8.PubMedCrossRef Tilsley DA, Rotstein H. Sensitivity caused by internal exposure to nickel, chrome and cobalt. Contact Dermatitis. 1980;6(3):175–8.PubMedCrossRef
103.
go back to reference Stroup DF, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA. 2000;283(15):2008–12.PubMedCrossRef Stroup DF, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA. 2000;283(15):2008–12.PubMedCrossRef
104.
go back to reference Granchi D, et al. Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater. 2006;77(2):257–64.PubMedCrossRef Granchi D, et al. Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res B Appl Biomater. 2006;77(2):257–64.PubMedCrossRef
105.
go back to reference Bahmer FA, Lesch H. Density of Langerhans’ cells in ATPase stained epidermal sheet preparations from stasis dermatitis skin of the lower leg. Acta Derm Venereol. 1987;67(4):301–4.PubMed Bahmer FA, Lesch H. Density of Langerhans’ cells in ATPase stained epidermal sheet preparations from stasis dermatitis skin of the lower leg. Acta Derm Venereol. 1987;67(4):301–4.PubMed
106.
go back to reference Prakash AV, Davis MD. Contact dermatitis in older adults: a review of the literature. Am J Clin Dermatol. 2010;11(6):373–81.PubMedCrossRef Prakash AV, Davis MD. Contact dermatitis in older adults: a review of the literature. Am J Clin Dermatol. 2010;11(6):373–81.PubMedCrossRef
107.
go back to reference Scott HJ, Coleridge Smith PD, Scurr JH. Histological study of white blood cells and their association with lipodermatosclerosis and venous ulceration. Br J Surg. 1991;78(2):210–1.PubMedCrossRef Scott HJ, Coleridge Smith PD, Scurr JH. Histological study of white blood cells and their association with lipodermatosclerosis and venous ulceration. Br J Surg. 1991;78(2):210–1.PubMedCrossRef
108.
go back to reference Barbaud A, et al. Contact allergy in chronic leg ulcers: results of a multicentre study carried out in 423 patients and proposal for an updated series of patch tests. Contact Dermatitis. 2009;60(5):279–87.PubMedCrossRef Barbaud A, et al. Contact allergy in chronic leg ulcers: results of a multicentre study carried out in 423 patients and proposal for an updated series of patch tests. Contact Dermatitis. 2009;60(5):279–87.PubMedCrossRef
109.
go back to reference Jankicevic J, et al. Contact sensitivity in patients with venous leg ulcers in Serbia: comparison with contact dermatitis patients and relationship to ulcer duration. Contact Dermatitis. 2008;58(1):32–6.PubMed Jankicevic J, et al. Contact sensitivity in patients with venous leg ulcers in Serbia: comparison with contact dermatitis patients and relationship to ulcer duration. Contact Dermatitis. 2008;58(1):32–6.PubMed
110.
go back to reference Machet L, et al. A high prevalence of sensitization still persists in leg ulcer patients: a retrospective series of 106 patients tested between 2001 and 2002 and a meta-analysis of 1975-2003 data. Br J Dermatol. 2004;150(5):929–35.PubMedCrossRef Machet L, et al. A high prevalence of sensitization still persists in leg ulcer patients: a retrospective series of 106 patients tested between 2001 and 2002 and a meta-analysis of 1975-2003 data. Br J Dermatol. 2004;150(5):929–35.PubMedCrossRef
111.
go back to reference Lim KS, et al. Contact sensitization in patients with chronic venous leg ulcers in Singapore. Contact Dermatitis. 2007;56(2):94–8.PubMedCrossRef Lim KS, et al. Contact sensitization in patients with chronic venous leg ulcers in Singapore. Contact Dermatitis. 2007;56(2):94–8.PubMedCrossRef
112.
go back to reference Tavadia S, et al. Allergic contact dermatitis in venous leg ulcer patients. Contact Dermatitis. 2003;48(5):261–5.PubMedCrossRef Tavadia S, et al. Allergic contact dermatitis in venous leg ulcer patients. Contact Dermatitis. 2003;48(5):261–5.PubMedCrossRef
113.
go back to reference Lindemayr H, Drobil M. Eczema of the lower leg and contact allergy. Hautarzt. 1985;36(4):227–31.PubMed Lindemayr H, Drobil M. Eczema of the lower leg and contact allergy. Hautarzt. 1985;36(4):227–31.PubMed
114.
go back to reference Wilkinson SM, English JS. Hydrocortisone sensitivity: clinical features of fifty-nine cases. J Am Acad Dermatol. 1992;27(5 Pt 1):683–7.PubMedCrossRef Wilkinson SM, English JS. Hydrocortisone sensitivity: clinical features of fifty-nine cases. J Am Acad Dermatol. 1992;27(5 Pt 1):683–7.PubMedCrossRef
115.
go back to reference Smart V, et al. Contact allergens in persons with leg ulcers: a Canadian study in contact sensitization. Int J Low Extrem Wounds. 2008;7(3):120–5.PubMedCrossRef Smart V, et al. Contact allergens in persons with leg ulcers: a Canadian study in contact sensitization. Int J Low Extrem Wounds. 2008;7(3):120–5.PubMedCrossRef
116.
go back to reference Sasseville D, Tennstedt D, Lachapelle JM. Allergic contact dermatitis from hydrocolloid dressings. Am J Contact Dermat. 1997;8(4):236–8.PubMed Sasseville D, Tennstedt D, Lachapelle JM. Allergic contact dermatitis from hydrocolloid dressings. Am J Contact Dermat. 1997;8(4):236–8.PubMed
117.
go back to reference Siegel DM. Contact sensitivity and recalcitrant wounds. Ostomy Wound Manage. 2000;46(1A Suppl):65S–74S. quiz 75S-76SPubMed Siegel DM. Contact sensitivity and recalcitrant wounds. Ostomy Wound Manage. 2000;46(1A Suppl):65S–74S. quiz 75S-76SPubMed
118.
go back to reference Shai A, Halevy S. Direct triggers for ulceration in patients with venous insufficiency. Int J Dermatol. 2005;44(12):1006–9.PubMedCrossRef Shai A, Halevy S. Direct triggers for ulceration in patients with venous insufficiency. Int J Dermatol. 2005;44(12):1006–9.PubMedCrossRef
119.
go back to reference Smith HR, Basketter DA, McFadden JP. Irritant dermatitis, irritancy and its role in allergic contact dermatitis. Clin Exp Dermatol. 2002;27(2):138–46.PubMedCrossRef Smith HR, Basketter DA, McFadden JP. Irritant dermatitis, irritancy and its role in allergic contact dermatitis. Clin Exp Dermatol. 2002;27(2):138–46.PubMedCrossRef
Metadata
Title
Contact Dermatitis in the Hospitalized Patient
Authors
Ilka Arun Netravali
Sarina B. Elmariah
Publication date
01-03-2017
Publisher
Springer US
Published in
Current Dermatology Reports / Issue 1/2017
Electronic ISSN: 2162-4933
DOI
https://doi.org/10.1007/s13671-017-0165-x

Other articles of this Issue 1/2017

Current Dermatology Reports 1/2017 Go to the issue

Psoriasis (J Wu, Section Editor)

Update on Ustekinumab for Psoriasis

Hospital-based Dermatology (D Kroshinsky, Section Editor)

Hair and Nail Manifestations of Systemic Disease

Atopic Dermatitis (T Bieber, Section Editor)

Comorbidities of Atopic Dermatitis: Beyond Rhinitis and Asthma

Cutaneous Drug Reactions (J Brieva, Section Editor)

Topical JAK Inhibitors for the Treatment of Alopecia Areata and Vitiligo