Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | Computer Aided Design | Research

Occlusal contact and clearance of posterior implant-supported single crowns designed by two different methods: a self-controlled study

Authors: Mingzhu He, Tingting Pu, Qian Ding, Yao Sun, Pengfei Wang, Yuchun Sun, Lei Zhang

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

Precise occlusal design of implant-supported fixed prostheses is difficult to achieve by the conventional wax-up method, often requiring chairside adjustments. The computer-aided design (CAD) method is promising. This study aims to compare the occlusal contacts and clearance of posterior implant-supported single crowns designed by the CAD and conventional methods.

Methods

Sample size calculation indicated fourteen samples per group. Two sets of type-IV plaster casts with a single implant analog inserted in the posterior teeth region were mounted as master casts in a mechanical articulator in maximal intercuspal position (MIP). Seven working cast sets were obtained from each master cast by a closed tray technique, and mounted in MIP. Two implant-supported single crowns were designed with an occlusal clearance to achieve light occlusal contact in each working cast set by CAD and conventional method, separately. For the CAD group, the crown was designed in digital models obtained by scanning the working casts. For the conventional group, wax-up of the crown was prepared on the working casts and scanned to generate a STL file. In the working and master casts, mean and minimum occlusal clearances in the designed occlusal contact area of the both finished prostheses were calculated using the occlusal clearance (OC) and occlusal record (OR) method. The prostheses’ occlusion was evaluated in master casts.

Results

For the evaluation in the working casts, both design methods had similar mean occlusal clearances by the OC method (195.4 ± 43.8 vs. 179.8 ± 41.8 μm; P = 0.300), while CAD group resulted in a significantly larger minimum occlusal clearance in the designed occlusal contact area (139.5 ± 52.3 vs. 99.8 ± 43.8 μm; P = 0.043). Both design methods had similar mean and minimum occlusal clearances by the OR method (P > 0.05). For the evaluation in the master casts, both design techniques had similar mean and minimum occlusal clearances, number and distribution of occlusal contacts, and lateral interference ratios (P > 0.05).

Conclusion

Occlusal contact and clearance of posterior implant-supported single crowns designed by the CAD method can be at least as good as those designed by the conventional wax-up method.
Literature
1.
go back to reference Graves CV, Harrel SK, Rossmann JA, Kerns D, Gonzalez JA, Kontogiorgos ED, et al. The role of occlusion in the dental implant and peri-implant condition: a review. Open Dent J. 2016;10(1):594–601.CrossRefPubMedPubMedCentral Graves CV, Harrel SK, Rossmann JA, Kerns D, Gonzalez JA, Kontogiorgos ED, et al. The role of occlusion in the dental implant and peri-implant condition: a review. Open Dent J. 2016;10(1):594–601.CrossRefPubMedPubMedCentral
2.
go back to reference Kim Y, Oh TJ, Misch CE, Wang H-L. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res. 2005;16(1):26–35.CrossRefPubMed Kim Y, Oh TJ, Misch CE, Wang H-L. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res. 2005;16(1):26–35.CrossRefPubMed
3.
go back to reference Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implants Res. 2012;23Suppl 6:22–38.CrossRef Pjetursson BE, Thoma D, Jung R, Zwahlen M, Zembic A. A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5 years. Clin Oral Implants Res. 2012;23Suppl 6:22–38.CrossRef
4.
go back to reference Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res. 2008;19(2):119–30.CrossRefPubMed Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP. A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res. 2008;19(2):119–30.CrossRefPubMed
5.
go back to reference Kollmuss M, Kist S, Goeke JE, Hickel R, Huth KC. Comparison of chairside and laboratory CAD/CAM to conventional produced all-ceramic crowns regarding morphology, occlusion, and aesthetics. Clin Oral Investig. 2016;20(4):791–7.CrossRefPubMed Kollmuss M, Kist S, Goeke JE, Hickel R, Huth KC. Comparison of chairside and laboratory CAD/CAM to conventional produced all-ceramic crowns regarding morphology, occlusion, and aesthetics. Clin Oral Investig. 2016;20(4):791–7.CrossRefPubMed
6.
go back to reference Muric A, Gokcen Röhlig B, Ongul D, Evlioglu G. Comparing the precision of reproducibility of computer-aided occlusal design to conventional methods. J Prosthodont Res. 2019;63(1):110–4.CrossRefPubMed Muric A, Gokcen Röhlig B, Ongul D, Evlioglu G. Comparing the precision of reproducibility of computer-aided occlusal design to conventional methods. J Prosthodont Res. 2019;63(1):110–4.CrossRefPubMed
7.
go back to reference Zhang R, Sun Y, Liu Y-S, Ding Q, Zhang L, Xie Q-F. Occlusal Assessment of Zirconia Crowns designed with the Digital Articulator and traditional methods. Int J Prosthodont. 2021;34(1):13–20.CrossRefPubMed Zhang R, Sun Y, Liu Y-S, Ding Q, Zhang L, Xie Q-F. Occlusal Assessment of Zirconia Crowns designed with the Digital Articulator and traditional methods. Int J Prosthodont. 2021;34(1):13–20.CrossRefPubMed
8.
go back to reference Arslan Y, Karakoca Nemli S, Bankoğlu Güngör M, Tamam E, Yılmaz H. Evaluation of biogeneric design techniques with CEREC CAD/CAM system. J Adv Prosthodont. 2015;7(6):431–6.CrossRefPubMedPubMedCentral Arslan Y, Karakoca Nemli S, Bankoğlu Güngör M, Tamam E, Yılmaz H. Evaluation of biogeneric design techniques with CEREC CAD/CAM system. J Adv Prosthodont. 2015;7(6):431–6.CrossRefPubMedPubMedCentral
9.
go back to reference Lewis MB, Klineberg I. Prosthodontic considerations designed to optimize outcomes for single-tooth implants. A review of the literature. Aust Dent J. 2011;56(2):181–92.CrossRefPubMed Lewis MB, Klineberg I. Prosthodontic considerations designed to optimize outcomes for single-tooth implants. A review of the literature. Aust Dent J. 2011;56(2):181–92.CrossRefPubMed
10.
go back to reference Davies SJ. Occlusal considerations in implantology: good occlusal practice in implantology. Dent Update. 2010;37(9):610–20.CrossRefPubMed Davies SJ. Occlusal considerations in implantology: good occlusal practice in implantology. Dent Update. 2010;37(9):610–20.CrossRefPubMed
11.
go back to reference Rilo B. José Luis da Silva, Maria Jesús Mora. Guidelines for occlusion strategy in implant-borne prostheses. A review. Int Dent J. 2011;58(3):139–45.CrossRef Rilo B. José Luis da Silva, Maria Jesús Mora. Guidelines for occlusion strategy in implant-borne prostheses. A review. Int Dent J. 2011;58(3):139–45.CrossRef
12.
go back to reference Iwauchi Y, Tanaka S, Kamimura-Sugimura E, Baba K. Clinical evaluation of the precision of interocclusal registration by using digital and conventional techniques. J Prosthet Dent. 2022;128(4):611–7.CrossRefPubMed Iwauchi Y, Tanaka S, Kamimura-Sugimura E, Baba K. Clinical evaluation of the precision of interocclusal registration by using digital and conventional techniques. J Prosthet Dent. 2022;128(4):611–7.CrossRefPubMed
13.
go back to reference He M, Ding Q, Li L, Yang G, Zhao Y, Sun Y, et al. The Accuracy of transferring casts in maximal intercuspal position to a virtual articulator. J Prosthodont. 2022;31(4):326–32.CrossRefPubMed He M, Ding Q, Li L, Yang G, Zhao Y, Sun Y, et al. The Accuracy of transferring casts in maximal intercuspal position to a virtual articulator. J Prosthodont. 2022;31(4):326–32.CrossRefPubMed
14.
go back to reference Ghodsi S, Rasaeipour S. Revising average condylar inclinations using Electronic Pantograph Assessment: a cross-sectional study. Dent Hypotheses. 2018;9(4):84–9.CrossRef Ghodsi S, Rasaeipour S. Revising average condylar inclinations using Electronic Pantograph Assessment: a cross-sectional study. Dent Hypotheses. 2018;9(4):84–9.CrossRef
15.
go back to reference UNE-EN. ISO 12836 – 2015,Dentistry - Digitizing devices for CAD/CAM systems for indirect dental restorations - Test methods for assessing accuracy (ISO 12836:2015). UNE-EN. ISO 12836 – 2015,Dentistry - Digitizing devices for CAD/CAM systems for indirect dental restorations - Test methods for assessing accuracy (ISO 12836:2015).
16.
go back to reference Buda M, Bratos M, Sorensen JA. Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts. J Prosthet Dent. 2018;120(6):913–8.CrossRefPubMed Buda M, Bratos M, Sorensen JA. Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts. J Prosthet Dent. 2018;120(6):913–8.CrossRefPubMed
17.
go back to reference Lee SJ, Betensky RA, Gianneschi GE, Gallucci GO. Accuracy of digital versus conventional implant impressions. Clin Oral Implants Res. 2015;26(6):715–9.CrossRefPubMed Lee SJ, Betensky RA, Gianneschi GE, Gallucci GO. Accuracy of digital versus conventional implant impressions. Clin Oral Implants Res. 2015;26(6):715–9.CrossRefPubMed
18.
go back to reference Peters MC, Delong R, Pintado MR, Pallesen U, Qvist V, Douglas WH. Comparison of two measurement techniques for clinical wear. J Dent. 1999;27(7):479–85.CrossRefPubMed Peters MC, Delong R, Pintado MR, Pallesen U, Qvist V, Douglas WH. Comparison of two measurement techniques for clinical wear. J Dent. 1999;27(7):479–85.CrossRefPubMed
19.
go back to reference Ohkuma K, Kameda T, Terada K. Five-axis laser milling system that realizes more accurate zirconia CAD/CAM crowns by direct milling from fully sintered blocks. Dent Mater J. 2019;38(1):52–60.CrossRefPubMed Ohkuma K, Kameda T, Terada K. Five-axis laser milling system that realizes more accurate zirconia CAD/CAM crowns by direct milling from fully sintered blocks. Dent Mater J. 2019;38(1):52–60.CrossRefPubMed
20.
go back to reference Wiley MG, Windeler AS, Barghi N, Duke SE. The vertical dimensional change resulting from polishing or glazing porcelain. J Prosthet Dent. 1989;62(1):32–4.CrossRefPubMed Wiley MG, Windeler AS, Barghi N, Duke SE. The vertical dimensional change resulting from polishing or glazing porcelain. J Prosthet Dent. 1989;62(1):32–4.CrossRefPubMed
21.
go back to reference Mehl C, Harder S, Steiner M, Vollrath O, Kern M. Influence of cement film thickness on the retention of implant-retained crowns. J Prosthodont. 2013;22(8):618–25.CrossRefPubMed Mehl C, Harder S, Steiner M, Vollrath O, Kern M. Influence of cement film thickness on the retention of implant-retained crowns. J Prosthodont. 2013;22(8):618–25.CrossRefPubMed
22.
go back to reference Rudolph H, Salmen H, Moldan M, Kuhn K, Sichwardt V, Wöstmann B, et al. Accuracy of intraoral and extraoral digital data acquisition for dental restorations. J Appl Oral Sci. 2016;24(1):85–94.CrossRefPubMedPubMedCentral Rudolph H, Salmen H, Moldan M, Kuhn K, Sichwardt V, Wöstmann B, et al. Accuracy of intraoral and extraoral digital data acquisition for dental restorations. J Appl Oral Sci. 2016;24(1):85–94.CrossRefPubMedPubMedCentral
23.
go back to reference Guo D, Pan S, Mühlemann S, Zhou Y, E Jung R. The migration of neighboring and antagonist teeth three months after implant placement in healed single tooth-missing sites. Clin Oral Implants Res. 2021;32(2):233–41.CrossRefPubMed Guo D, Pan S, Mühlemann S, Zhou Y, E Jung R. The migration of neighboring and antagonist teeth three months after implant placement in healed single tooth-missing sites. Clin Oral Implants Res. 2021;32(2):233–41.CrossRefPubMed
24.
go back to reference Mehl A. A new concept for the integration of dynamic occlusion in the digital construction process. Int J Comput Dent. 2012;15(2):109–23.PubMed Mehl A. A new concept for the integration of dynamic occlusion in the digital construction process. Int J Comput Dent. 2012;15(2):109–23.PubMed
25.
go back to reference Farias-Neto A, Dias AH, de Miranda BF, de Oliveira AR. Face-bow transfer in prosthodontics: a systematic review of the literature. J Oral Rehabil. 2013;40(9):686–92.CrossRefPubMed Farias-Neto A, Dias AH, de Miranda BF, de Oliveira AR. Face-bow transfer in prosthodontics: a systematic review of the literature. J Oral Rehabil. 2013;40(9):686–92.CrossRefPubMed
26.
go back to reference Yohn K. The face bow is irrelevant for making prostheses and planning orthognathic surgery. J Am Dent Assoc. 2016;147(6):421–6.CrossRefPubMed Yohn K. The face bow is irrelevant for making prostheses and planning orthognathic surgery. J Am Dent Assoc. 2016;147(6):421–6.CrossRefPubMed
27.
go back to reference Zhang R, Sun Y, Liu Y, Ding Q, Zhang L, Xie Q. Occlusal Assessment of Zirconia Crowns designed with the Digital Articulator and traditional methods. Int J Prosthodont. 2021;34(1):13–20.CrossRefPubMed Zhang R, Sun Y, Liu Y, Ding Q, Zhang L, Xie Q. Occlusal Assessment of Zirconia Crowns designed with the Digital Articulator and traditional methods. Int J Prosthodont. 2021;34(1):13–20.CrossRefPubMed
28.
go back to reference Cicciù M, Fiorillo L, D’Amico C, Gambino D, Amantia EM, Laino L et al. 3D Digital Impression Systems Compared with Traditional Techniques in Dentistry: A Recent Data Systematic Review.Materials (Basel). 2020; 23;13(8):1982. Cicciù M, Fiorillo L, D’Amico C, Gambino D, Amantia EM, Laino L et al. 3D Digital Impression Systems Compared with Traditional Techniques in Dentistry: A Recent Data Systematic Review.Materials (Basel). 2020; 23;13(8):1982.
29.
go back to reference Hsu MR, Driscoll CF, Romberg E, Masri R. Accuracy of dynamic virtual articulation: trueness and Precision. J Prosthodont. 2019;28(4):436–43.CrossRefPubMed Hsu MR, Driscoll CF, Romberg E, Masri R. Accuracy of dynamic virtual articulation: trueness and Precision. J Prosthodont. 2019;28(4):436–43.CrossRefPubMed
30.
go back to reference Cicciù M, Cervino G, Terranova A, Risitano G, Raffaele M, Cucinotta F, et al. Prosthetic and mechanical parameters of the facial bone under the load of different Dental Implant Shapes: a Parametric Study. Prosthesis. 2019;1(1):41–53.CrossRef Cicciù M, Cervino G, Terranova A, Risitano G, Raffaele M, Cucinotta F, et al. Prosthetic and mechanical parameters of the facial bone under the load of different Dental Implant Shapes: a Parametric Study. Prosthesis. 2019;1(1):41–53.CrossRef
31.
go back to reference Koyano K, Esaki D. Occlusion on oral implants: current clinical guidelines. J Oral Rehabil. 2015;42(2):153–61.CrossRefPubMed Koyano K, Esaki D. Occlusion on oral implants: current clinical guidelines. J Oral Rehabil. 2015;42(2):153–61.CrossRefPubMed
32.
go back to reference Papaspyridakos P, Chen CJ, Gallucci GO, Doukoudakis A, Weber HP, Chronopoulos V. Accuracy of implant impressions for partially and completely edentulous patients: a systematic review. Int J Oral Maxillofac Implants. 2014;29(4):836–45.CrossRefPubMed Papaspyridakos P, Chen CJ, Gallucci GO, Doukoudakis A, Weber HP, Chronopoulos V. Accuracy of implant impressions for partially and completely edentulous patients: a systematic review. Int J Oral Maxillofac Implants. 2014;29(4):836–45.CrossRefPubMed
Metadata
Title
Occlusal contact and clearance of posterior implant-supported single crowns designed by two different methods: a self-controlled study
Authors
Mingzhu He
Tingting Pu
Qian Ding
Yao Sun
Pengfei Wang
Yuchun Sun
Lei Zhang
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-02847-w

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue