Skip to main content
Top
Published in: BMC Oral Health 1/2023

Open Access 01-12-2023 | Computer Aided Design | Research

Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars

Authors: Qi Wang, Zhenzhen Zhang, Sheng Zhong, Jiajia Liu, Ying Hu, Ziling Zhou, Caidi Zhang, Shizhu Bai, Li’an Wu

Published in: BMC Oral Health | Issue 1/2023

Login to get access

Abstract

Background

Premature loss of primary molars can be treated with a band loop space maintainer (SM). However, fabricating a conventional band loop SM requires multiple clinical and laboratory procedures, which can potentially affect the accuracy of the SM. Moreover, the conventional SM is unable to fully restore masticatory function and maintain the vertical dimension of the edentulous space. In this current study, a fully digital workflow to fabricate a semi-rigid bridge SM made from polyetheretherketone (PEEK) has been described and evaluated for its clinical effectiveness.

Methods

A total of 15 children (eight males and seven females) between the ages of 4–8 years, who experienced the premature loss of a single primary molar, were included in this study. Digital impressions were taken using the CEREC CAD/CAM chair system and imported into CAD software to design the semi-rigid bridge SM, which was fabricated using PEEK block as the maintainer material. The digital SM was tried-in and bonded to the abutment with resin cement. The edentulous space was measured immediately after bonding (T0) and 1 month (T1), 3 months (T2), and 6 months (T3) after treatment. The periodontal condition and mobility of the SM and abutment were also examined.

Results

The use of digital impressions resulted in a decreased occurrence of the pharyngeal reflex. The digital semi-rigid bridge SM, fabricated with PEEK, was both convenient and aesthetically pleasing, and successfully restored the anatomy and masticatory function of the missing primary molar. None of the 15 semi-rigid bridge SMs or abutments became loose or fell off during the study, and only one child presented with gingivitis. Furthermore, the difference in the edentulous space at T0, T1, T2, and T3 was not statistically significant (all P > 0.05).

Conclusions

The digital semi-rigid bridge SM fabricated with PEEK was clinically effective in maintaining the missing space and had advantages over the traditional band/crown loop SM.
Literature
2.
go back to reference Tokuc M, Yilmaz H. Comparison of fit accuracy between conventional and CAD/CAM-fabricated band-loop space maintainers. Int J Paediatr Dent. 2022;32(5):764–71.CrossRefPubMed Tokuc M, Yilmaz H. Comparison of fit accuracy between conventional and CAD/CAM-fabricated band-loop space maintainers. Int J Paediatr Dent. 2022;32(5):764–71.CrossRefPubMed
4.
go back to reference Soni HK. Application of CAD-CAM for fabrication of metal-free Band and Loop Space Maintainer. J Clin Diagn Res. 2017;11(2):Zd14–zd16.PubMedPubMedCentral Soni HK. Application of CAD-CAM for fabrication of metal-free Band and Loop Space Maintainer. J Clin Diagn Res. 2017;11(2):Zd14–zd16.PubMedPubMedCentral
5.
go back to reference Ge LH. Pediatric Dentistry (in Chinese). Beijing: People’s Medical Publishing House; 2020. Ge LH. Pediatric Dentistry (in Chinese). Beijing: People’s Medical Publishing House; 2020.
6.
go back to reference Hallab NJ, McAllister K, Brady M, Jarman-Smith M. Macrophage reactivity to different polymers demonstrates particle size- and material-specific reactivity: PEEK-OPTIMA(®) particles versus UHMWPE particles in the submicron, micron, and 10 micron size ranges. J Biomed Mater Res B Appl Biomater. 2012;100(2):480–92.CrossRefPubMed Hallab NJ, McAllister K, Brady M, Jarman-Smith M. Macrophage reactivity to different polymers demonstrates particle size- and material-specific reactivity: PEEK-OPTIMA(®) particles versus UHMWPE particles in the submicron, micron, and 10 micron size ranges. J Biomed Mater Res B Appl Biomater. 2012;100(2):480–92.CrossRefPubMed
7.
go back to reference Guo H, Wang Y, Zhao Y, Liu H. Computer-aided design of polyetheretherketone for application to removable pediatric space maintainers. BMC Oral Health. 2020;20(1):201.CrossRefPubMedPubMedCentral Guo H, Wang Y, Zhao Y, Liu H. Computer-aided design of polyetheretherketone for application to removable pediatric space maintainers. BMC Oral Health. 2020;20(1):201.CrossRefPubMedPubMedCentral
8.
go back to reference Harb IE, Abdel-Khalek EA, Hegazy SA. CAD/CAM constructed poly(etheretherketone) (PEEK) Framework of Kennedy Class I removable partial denture: a clinical report. J Prosthodont. 2019;28(2):e595–8.CrossRefPubMed Harb IE, Abdel-Khalek EA, Hegazy SA. CAD/CAM constructed poly(etheretherketone) (PEEK) Framework of Kennedy Class I removable partial denture: a clinical report. J Prosthodont. 2019;28(2):e595–8.CrossRefPubMed
9.
go back to reference Siqueira R, Galli M, Chen Z, Mendonça G, Meirelles L, Wang HL, Chan HL. Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review. Clin Oral Investig. 2021;25(12):6517–31.CrossRefPubMedPubMedCentral Siqueira R, Galli M, Chen Z, Mendonça G, Meirelles L, Wang HL, Chan HL. Intraoral scanning reduces procedure time and improves patient comfort in fixed prosthodontics and implant dentistry: a systematic review. Clin Oral Investig. 2021;25(12):6517–31.CrossRefPubMedPubMedCentral
10.
go back to reference Khanna S, Rao D, Panwar S, Pawar BA, Ameen S. 3D printed Band and Loop Space Maintainer: a Digital game changer in preventive orthodontics. J Clin Pediatr Dent. 2021;45(3):147–51.CrossRefPubMed Khanna S, Rao D, Panwar S, Pawar BA, Ameen S. 3D printed Band and Loop Space Maintainer: a Digital game changer in preventive orthodontics. J Clin Pediatr Dent. 2021;45(3):147–51.CrossRefPubMed
11.
go back to reference Pawar BA. Maintenance of space by innovative three-dimensional-printed band and loop space maintainer. J Indian Soc Pedod Prev Dent. 2019;37(2):205–8.CrossRefPubMed Pawar BA. Maintenance of space by innovative three-dimensional-printed band and loop space maintainer. J Indian Soc Pedod Prev Dent. 2019;37(2):205–8.CrossRefPubMed
13.
go back to reference Dhanotra KG, Bhatia R. Digitainers-Digital Space Maintainers: a review. Int J Clin Pediatr Dent. 2021;14(Suppl 1):69–s75. Dhanotra KG, Bhatia R. Digitainers-Digital Space Maintainers: a review. Int J Clin Pediatr Dent. 2021;14(Suppl 1):69–s75.
14.
go back to reference Ierardo G, Luzzi V, Lesti M, Vozza I, Brugnoletti O, Polimeni A, Bossù M. Peek polymer in orthodontics: a pilot study on children. J Clin Exp Dent. 2017;9(10):e1271–5.CrossRefPubMedPubMedCentral Ierardo G, Luzzi V, Lesti M, Vozza I, Brugnoletti O, Polimeni A, Bossù M. Peek polymer in orthodontics: a pilot study on children. J Clin Exp Dent. 2017;9(10):e1271–5.CrossRefPubMedPubMedCentral
15.
go back to reference Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: a narrative review. BMC Oral Health. 2020;20(1):217.CrossRefPubMedPubMedCentral Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: a narrative review. BMC Oral Health. 2020;20(1):217.CrossRefPubMedPubMedCentral
16.
go back to reference Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR. Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater. 2013;101(7):1209–16.CrossRefPubMed Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR. Polyetheretherketone-a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater. 2013;101(7):1209–16.CrossRefPubMed
17.
go back to reference Verkouteren DRC, de Sonnaville WFC, Zuithoff NPA, Wulffraat NM, Steenks MH, Rosenberg A. Growth curves for mandibular range of motion and maximum voluntary bite force in healthy children. Eur J Oral Sci. 2022;130(3):e12869.CrossRefPubMedPubMedCentral Verkouteren DRC, de Sonnaville WFC, Zuithoff NPA, Wulffraat NM, Steenks MH, Rosenberg A. Growth curves for mandibular range of motion and maximum voluntary bite force in healthy children. Eur J Oral Sci. 2022;130(3):e12869.CrossRefPubMedPubMedCentral
18.
go back to reference Shiau YY, Wang JS. The effects of dental condition on hand strength and maximum bite force. Cranio. 1993;11(1):48–54. discussion 54.CrossRefPubMed Shiau YY, Wang JS. The effects of dental condition on hand strength and maximum bite force. Cranio. 1993;11(1):48–54. discussion 54.CrossRefPubMed
Metadata
Title
Clinical application of a digital semi-rigid bridge space maintainer fabricated from polyetheretherketone for premature loss of primary molars
Authors
Qi Wang
Zhenzhen Zhang
Sheng Zhong
Jiajia Liu
Ying Hu
Ziling Zhou
Caidi Zhang
Shizhu Bai
Li’an Wu
Publication date
01-12-2023
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2023
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-023-03570-2

Other articles of this Issue 1/2023

BMC Oral Health 1/2023 Go to the issue