Skip to main content
Top
Published in: Knee Surgery, Sports Traumatology, Arthroscopy 12/2011

01-12-2011 | Knee

Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs

Authors: Jong-Keun Seon, Ju-Kwon Park, Young-Joo Shin, Hyung-Yeon Seo, Keun-Bae Lee, Eun-Kyoo Song

Published in: Knee Surgery, Sports Traumatology, Arthroscopy | Issue 12/2011

Login to get access

Abstract

Purpose

The purpose of this study was to compare in vivo kinematics, range of motion, and functional outcomes in patients that received either a high-flexion cruciate retaining or a high-flexion cruciate substituting knee.

Methods

Forty-eight high-flexion cruciate retaining (CR) and 47 high-flexion cruciate substituting (PS) knees were included in this study and followed for an average of 27 months (24–33). Weight-bearing and non-weight-bearing maximal flexions and functional scores were compared between two groups. For kinematics evaluations, amount of posterior femoral roll-back and internal tibial rotation from 0° to maximal flexion using lateral radiographs under weight-bearing conditions were also compared.

Results

Average weight-bearing maximal flexion was 126.3° in the PS group, which was significantly higher than the 115.0° in the CR group. Average functional scores showed no significant difference between the two groups. In terms of kinematics, the average amount of posterior femoral roll-back during full flexion was 9.6 mm in the PS group and 6.1 mm in the CR group, which was a significant difference. However, internal tibial rotation during full flexion was not significantly different in the two groups.

Conclusion

PS high-flexion TKA provided greater weight-bearing maximal flexion and posterior femoral roll-back than CR high-flexion TKA, although no difference in clinical outcomes was observed between the two prosthesis designs.

Level of evidence

I.
Literature
1.
go back to reference Anouchi YS, McShane M, Kelly F Jr et al (1996) Range of motion in total knee replacement. Clin Orthop Relat Res 331:87–92PubMedCrossRef Anouchi YS, McShane M, Kelly F Jr et al (1996) Range of motion in total knee replacement. Clin Orthop Relat Res 331:87–92PubMedCrossRef
2.
go back to reference Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304PubMedCrossRef Banks SA, Markovich GD, Hodge WA (1997) In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. J Arthroplasty 12:297–304PubMedCrossRef
3.
go back to reference Becker MW, Insall JN, Faris PM (1991) Bilateral total knee arthroplasty. One cruciate retaining and one cruciate substituting. Clin Orthop Relat Res 271:122–124PubMed Becker MW, Insall JN, Faris PM (1991) Bilateral total knee arthroplasty. One cruciate retaining and one cruciate substituting. Clin Orthop Relat Res 271:122–124PubMed
4.
go back to reference Bellemans J, Banks S, Victor J et al (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84:50–53PubMedCrossRef Bellemans J, Banks S, Victor J et al (2002) Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset. J Bone Joint Surg Br 84:50–53PubMedCrossRef
5.
go back to reference Cates HE, Komistek RD, Mahfouz MR et al (2008) In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty 23:1057–1067PubMedCrossRef Cates HE, Komistek RD, Mahfouz MR et al (2008) In vivo comparison of knee kinematics for subjects having either a posterior stabilized or cruciate retaining high-flexion total knee arthroplasty. J Arthroplasty 23:1057–1067PubMedCrossRef
6.
go back to reference Dennis DA, Komistek RD, Colwell CE Jr et al (1998) In vivo anteroposterior femorotibial translation: a multicenter analysis. Clin Orthop Relat Res 356:47–57PubMedCrossRef Dennis DA, Komistek RD, Colwell CE Jr et al (1998) In vivo anteroposterior femorotibial translation: a multicenter analysis. Clin Orthop Relat Res 356:47–57PubMedCrossRef
7.
go back to reference Dennis DA, Komistek RD, Mahfouz MR et al (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR et al (2003) Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res 416:37–57PubMedCrossRef
8.
go back to reference Dennis DA, Komistek RD, Mahfouz MR et al (2004) A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res 428:180–189PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR et al (2004) A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res 428:180–189PubMedCrossRef
9.
go back to reference Dennis DA, Komistek RD, Stiehl JB et al (1998) Range of motion following total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13:748–752PubMedCrossRef Dennis DA, Komistek RD, Stiehl JB et al (1998) Range of motion following total knee arthroplasty: the effect of implant design and weight-bearing conditions. J Arthroplasty 13:748–752PubMedCrossRef
10.
go back to reference Hartford JM, Banit D, Hall K et al (2001) Radiographic analysis of low contact stress meniscal bearing total knee replacements. J Bone Joint Surg Am 83:229–234PubMed Hartford JM, Banit D, Hall K et al (2001) Radiographic analysis of low contact stress meniscal bearing total knee replacements. J Bone Joint Surg Am 83:229–234PubMed
11.
go back to reference Kim YH, Choi Y, Kwon OR et al (2009) Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am 91:753–760PubMedCrossRef Kim YH, Choi Y, Kwon OR et al (2009) Functional outcome and range of motion of high-flexion posterior cruciate-retaining and high-flexion posterior cruciate-substituting total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am 91:753–760PubMedCrossRef
12.
go back to reference Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am 87:1470–1475PubMedCrossRef Kim YH, Sohn KS, Kim JS (2005) Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am 87:1470–1475PubMedCrossRef
13.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
14.
go back to reference Maloney WJ, Schurman DJ (1992) The effects of implant design on range of motion after total knee arthroplasty. Total condylar versus posterior stabilized total condylar designs. Clin Orthop Relat Res 278:147–152PubMed Maloney WJ, Schurman DJ (1992) The effects of implant design on range of motion after total knee arthroplasty. Total condylar versus posterior stabilized total condylar designs. Clin Orthop Relat Res 278:147–152PubMed
15.
go back to reference Massin P, Gournay A (2006) Optimization of the posterior condylar offset, tibial slope, and condylar roll-back in total knee arthroplasty. J Arthroplasty 21:889–896PubMedCrossRef Massin P, Gournay A (2006) Optimization of the posterior condylar offset, tibial slope, and condylar roll-back in total knee arthroplasty. J Arthroplasty 21:889–896PubMedCrossRef
16.
go back to reference Most E, Sultan PG, Park SE et al (2006) Tibiofemoral contact behavior is improved in high-flexion cruciate retaining TKA. Clin Orthop Relat Res 452:59–64PubMedCrossRef Most E, Sultan PG, Park SE et al (2006) Tibiofemoral contact behavior is improved in high-flexion cruciate retaining TKA. Clin Orthop Relat Res 452:59–64PubMedCrossRef
17.
go back to reference Most E, Sultan PG, Park SE et al (2005) Kinematic analysis of conventional and high-flexion cruciate-retaining total knee arthroplasties: an in vitro investigation. J Arthroplasty 20:529–535PubMedCrossRef Most E, Sultan PG, Park SE et al (2005) Kinematic analysis of conventional and high-flexion cruciate-retaining total knee arthroplasties: an in vitro investigation. J Arthroplasty 20:529–535PubMedCrossRef
18.
go back to reference Myles CM, Rowe PJ, Walker CR et al (2002) Knee joint functional range of movement prior to and following total knee arthroplasty measured using flexible electrogoniometry. Gait Posture 16:46–54PubMedCrossRef Myles CM, Rowe PJ, Walker CR et al (2002) Knee joint functional range of movement prior to and following total knee arthroplasty measured using flexible electrogoniometry. Gait Posture 16:46–54PubMedCrossRef
19.
go back to reference Sharma A, Komistek RD, Scuderi GR et al (2007) High-flexion TKA designs: what are their in vivo contact mechanics? Clin Orthop Relat Res 464:117–126PubMed Sharma A, Komistek RD, Scuderi GR et al (2007) High-flexion TKA designs: what are their in vivo contact mechanics? Clin Orthop Relat Res 464:117–126PubMed
20.
go back to reference Shi K, Hayashida K, Umeda N et al (2007) Kinematic comparison between mobile-bearing and fixed-bearing inserts in Nexgen legacy posterior stabilized flex total knee arthroplasty. J Arthroplasty 23:164–169PubMedCrossRef Shi K, Hayashida K, Umeda N et al (2007) Kinematic comparison between mobile-bearing and fixed-bearing inserts in Nexgen legacy posterior stabilized flex total knee arthroplasty. J Arthroplasty 23:164–169PubMedCrossRef
21.
go back to reference Stiehl JB, Komistek RD, Dennis DA (1999) Detrimental kinematics of a flat on flat total condylar knee arthroplasty. Clin Orthop Relat Res 365:139–148PubMedCrossRef Stiehl JB, Komistek RD, Dennis DA (1999) Detrimental kinematics of a flat on flat total condylar knee arthroplasty. Clin Orthop Relat Res 365:139–148PubMedCrossRef
22.
go back to reference Stiehl JB, Komistek RD, Dennis DA et al (1995) Fluoroscopic analysis after posterior cruciate retaining knee arthroplasty. J Bone Joint Surg Br 77:884–889PubMed Stiehl JB, Komistek RD, Dennis DA et al (1995) Fluoroscopic analysis after posterior cruciate retaining knee arthroplasty. J Bone Joint Surg Br 77:884–889PubMed
23.
go back to reference Suggs JF, Hanson GR, Park SE et al (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296PubMedCrossRef Suggs JF, Hanson GR, Park SE et al (2008) Patient function after a posterior stabilizing total knee arthroplasty: cam-post engagement and knee kinematics. Knee Surg Sports Traumatol Arthrosc 16:290–296PubMedCrossRef
24.
go back to reference Suggs JF, Kwon YM, Durbhakula SM et al (2009) In vivo flexion and kinematics of the knee after TKA: comparison of a conventional and a high flexion cruciate-retaining TKA design. Knee Surg Sports Traumatol Arthrosc 17:150–156PubMedCrossRef Suggs JF, Kwon YM, Durbhakula SM et al (2009) In vivo flexion and kinematics of the knee after TKA: comparison of a conventional and a high flexion cruciate-retaining TKA design. Knee Surg Sports Traumatol Arthrosc 17:150–156PubMedCrossRef
Metadata
Title
Comparisons of kinematics and range of motion in high-flexion total knee arthroplasty: cruciate retaining vs. substituting designs
Authors
Jong-Keun Seon
Ju-Kwon Park
Young-Joo Shin
Hyung-Yeon Seo
Keun-Bae Lee
Eun-Kyoo Song
Publication date
01-12-2011
Publisher
Springer-Verlag
Published in
Knee Surgery, Sports Traumatology, Arthroscopy / Issue 12/2011
Print ISSN: 0942-2056
Electronic ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-011-1434-z

Other articles of this Issue 12/2011

Knee Surgery, Sports Traumatology, Arthroscopy 12/2011 Go to the issue