Skip to main content
Top
Published in: BMC Musculoskeletal Disorders 1/2014

Open Access 01-12-2014 | Research article

Comparison of three plate system for lateral malleolar fixation

Authors: ZeYu Huang, Lei Liu, ChongQi Tu, Hui Zhang, Yue Fang, TianFu Yang, FuXing Pei

Published in: BMC Musculoskeletal Disorders | Issue 1/2014

Login to get access

Abstract

Background

This study was to compare clinical and radiographic outcomes with three different implants and evaluate the effectiveness of minimally invasive plate osteosynthesis (MIPO) technique for the distal fibular fractures.

Methods

We performed a retrospective cohort single-surgical team single-facility study between 2000 and 2011. 147 patients receiving surgical interventions for closed, displaced distal fibular fractures were included. Based on the different implants, patients were divided into three groups: Group A: one-third tubular plate; Group B: locking compression (LCP) metaphyseal plate; Group C: LCP distal fibula plate. Clinical and radiographic outcomes were compared among the three groups.

Results

Totally, we found that patients in Group C had significant higher functional scores than those in Group A (p1 = 0.004; p2 = 0.002) (p1 stands for the p value for Olerud & Molandar Score, p2 stands for the p value for American Orthopaedic Foot & Ankle Society score). The healing time was significant less in Group C than that in Group A (p < 0.0001) and Group B (p < 0.0001). Subgroup analysis showed that: (1) For Weber A fracture, the functional scores of the Group C were higher than those in Group A (p1 = 0.020; p2 = 0.029) and B (p1 = 0.020; p2 = 0.034). (2) For Weber B fracture, the functional scores of the Group B (p1 = 0.033; p2 = 0.030) and C (p1 = 0.027; p2 = 0.017) were higher than those in Group A. No significant differences were observed in terms of the ankle range of motion, reduction accuracy and complication rate.

Conclusions

Our study demonstrated using LCP metaphyseal plate in patients associated with lateral malleolar fracture could achieve significantly better OMS & AOFAS scores and less healing time than using one-third tubular plate. Specifically, For Weber A fracture, LCP distal fibula plate is much better than one-third tubular plate and LCP metaphyseal plate. While for Weber B fracture, LCP distal fibula plate and LCP metaphyseal plate are better than one-third tubular plate. As to the complications, using MIPO technique in patients with distal fibular fractures is at least comparable to the traditional one.
Appendix
Available only for authorised users
Literature
1.
go back to reference Strauss EJ, Egol KA: The management of ankle fractures in the elderly. Injury. 2007, 38 (Suppl 3): S2-S9.CrossRefPubMed Strauss EJ, Egol KA: The management of ankle fractures in the elderly. Injury. 2007, 38 (Suppl 3): S2-S9.CrossRefPubMed
2.
go back to reference Salai M, Dudkiewicz I, Novikov I, Amit Y, Chechick A: The epidemic of ankle fractures in the elderly–is surgical treatment warranted?. Arch Orthop Trauma Surg. 2000, 120: 511-513. 10.1007/s004020000172.CrossRefPubMed Salai M, Dudkiewicz I, Novikov I, Amit Y, Chechick A: The epidemic of ankle fractures in the elderly–is surgical treatment warranted?. Arch Orthop Trauma Surg. 2000, 120: 511-513. 10.1007/s004020000172.CrossRefPubMed
3.
go back to reference Lin CW, Moseley AM, Refshauge KM: Effects of rehabilitation after ankle fracture: a Cochrane systematic review. Eur J Phys Rehabil Med. 2009, 45: 431-441.PubMed Lin CW, Moseley AM, Refshauge KM: Effects of rehabilitation after ankle fracture: a Cochrane systematic review. Eur J Phys Rehabil Med. 2009, 45: 431-441.PubMed
4.
go back to reference Morin PM, Reindl R, Harvey EJ, Beckman L, Steffen T: Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation. Can J Surg. 2008, 51: 45-50.PubMedPubMedCentral Morin PM, Reindl R, Harvey EJ, Beckman L, Steffen T: Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation. Can J Surg. 2008, 51: 45-50.PubMedPubMedCentral
5.
go back to reference Vallier HA, Cureton BA, Patterson BM: Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures. J Orthop Trauma. 2011, 25: 736-741. 10.1097/BOT.0b013e318213f709.CrossRefPubMed Vallier HA, Cureton BA, Patterson BM: Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures. J Orthop Trauma. 2011, 25: 736-741. 10.1097/BOT.0b013e318213f709.CrossRefPubMed
6.
go back to reference Khalily C, Behnke S, Seligson D: Treatment of closed tibia shaft fractures: a survey from the 1997 Orthopaedic Trauma Association and Osteosynthesis International--Gerhard Kuntscher Kreis meeting. J Orthop Trauma. 2000, 14: 577-581. 10.1097/00005131-200011000-00011.CrossRefPubMed Khalily C, Behnke S, Seligson D: Treatment of closed tibia shaft fractures: a survey from the 1997 Orthopaedic Trauma Association and Osteosynthesis International--Gerhard Kuntscher Kreis meeting. J Orthop Trauma. 2000, 14: 577-581. 10.1097/00005131-200011000-00011.CrossRefPubMed
7.
go back to reference Leyes M, Torres R, Guillen P: Complications of open reduction and internal fixation of ankle fractures. Foot Ankle Clin. 2003, 8: 131-147. 10.1016/S1083-7515(02)00162-6.CrossRefPubMed Leyes M, Torres R, Guillen P: Complications of open reduction and internal fixation of ankle fractures. Foot Ankle Clin. 2003, 8: 131-147. 10.1016/S1083-7515(02)00162-6.CrossRefPubMed
8.
go back to reference Sommer C, Gautier E, Muller M, Helfet DL, Wagner M: First clinical results of the Locking Compression Plate (LCP). Injury. 2003, 34 (Suppl 2): B43-B54.CrossRefPubMed Sommer C, Gautier E, Muller M, Helfet DL, Wagner M: First clinical results of the Locking Compression Plate (LCP). Injury. 2003, 34 (Suppl 2): B43-B54.CrossRefPubMed
9.
10.
go back to reference Myller M: Manual of Internal Fixation: Techniques Recommended by the AO-ASIF Group. 1991, Berlin: SpringerCrossRef Myller M: Manual of Internal Fixation: Techniques Recommended by the AO-ASIF Group. 1991, Berlin: SpringerCrossRef
11.
go back to reference Hess F, Sommer C: Minimally invasive plate osteosynthesis of the distal fibula with the locking compression plate: first experience of 20 cases. J Orthop Trauma. 2011, 25: 110-115. 10.1097/BOT.0b013e3181d9e875.CrossRefPubMed Hess F, Sommer C: Minimally invasive plate osteosynthesis of the distal fibula with the locking compression plate: first experience of 20 cases. J Orthop Trauma. 2011, 25: 110-115. 10.1097/BOT.0b013e3181d9e875.CrossRefPubMed
12.
go back to reference Olerud C, Molander H: A scoring scale for symptom evaluation after ankle fracture. Arch Orthop Trauma Surg. 1984, 103: 190-194. 10.1007/BF00435553.CrossRefPubMed Olerud C, Molander H: A scoring scale for symptom evaluation after ankle fracture. Arch Orthop Trauma Surg. 1984, 103: 190-194. 10.1007/BF00435553.CrossRefPubMed
13.
go back to reference Kitaoka HB, Alexander IJ, Adelaar RS, Nunley JA, Myerson MS, Sanders M: Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int. 1994, 15: 349-353. 10.1177/107110079401500701.CrossRefPubMed Kitaoka HB, Alexander IJ, Adelaar RS, Nunley JA, Myerson MS, Sanders M: Clinical rating systems for the ankle-hindfoot, midfoot, hallux, and lesser toes. Foot Ankle Int. 1994, 15: 349-353. 10.1177/107110079401500701.CrossRefPubMed
14.
go back to reference Tscherne H, Oestern HJ: A new classification of soft-tissue damage in open and closed fractures (author's transl). Unfallheilkunde. 1982, 85: 111-115.PubMed Tscherne H, Oestern HJ: A new classification of soft-tissue damage in open and closed fractures (author's transl). Unfallheilkunde. 1982, 85: 111-115.PubMed
15.
go back to reference McLennan JG, Ungersma JA: A new approach to the treatment of ankle fractures. The Inyo nail. Clin Orthop Relat Res. 1986, 213: 125-136.PubMed McLennan JG, Ungersma JA: A new approach to the treatment of ankle fractures. The Inyo nail. Clin Orthop Relat Res. 1986, 213: 125-136.PubMed
16.
go back to reference Lamontagne J, Blachut PA, Broekhuyse HM, O’Brien PJ, Meek RN: Surgical treatment of a displaced lateral malleolus fracture: the antiglide technique versus lateral plate fixation. J Orthop Trauma. 2002, 16: 498-502. 10.1097/00005131-200208000-00008.CrossRefPubMed Lamontagne J, Blachut PA, Broekhuyse HM, O’Brien PJ, Meek RN: Surgical treatment of a displaced lateral malleolus fracture: the antiglide technique versus lateral plate fixation. J Orthop Trauma. 2002, 16: 498-502. 10.1097/00005131-200208000-00008.CrossRefPubMed
17.
go back to reference Anglen J, Kyle RF, Marsh JL, Virkus WW, Watters WC, Keith MW, Turkelson CM, Boyer KM: Locking plates for extremity fractures. J Am Acad Orthop Surg. 2009, 17: 465-472.CrossRefPubMed Anglen J, Kyle RF, Marsh JL, Virkus WW, Watters WC, Keith MW, Turkelson CM, Boyer KM: Locking plates for extremity fractures. J Am Acad Orthop Surg. 2009, 17: 465-472.CrossRefPubMed
18.
go back to reference Zahn RK, Frey S, Jakubietz RG, Jakubietz MG, Doht S, Schneider P, Waschke J, Meffert RH: A contoured locking plate for distal fibular fractures in osteoporotic bone: a biomechanical cadaver study. Injury. 2012, 43: 718-725. 10.1016/j.injury.2011.07.009.CrossRefPubMed Zahn RK, Frey S, Jakubietz RG, Jakubietz MG, Doht S, Schneider P, Waschke J, Meffert RH: A contoured locking plate for distal fibular fractures in osteoporotic bone: a biomechanical cadaver study. Injury. 2012, 43: 718-725. 10.1016/j.injury.2011.07.009.CrossRefPubMed
19.
go back to reference White NJ, Corr DT, Wagg JP, Lorincz C, Buckley RE: Locked plate fixation of the comminuted distal fibula: a biomechanical study. Can J Surg. 2013, 56: 35-40. 10.1503/cjs.012311.CrossRefPubMedPubMedCentral White NJ, Corr DT, Wagg JP, Lorincz C, Buckley RE: Locked plate fixation of the comminuted distal fibula: a biomechanical study. Can J Surg. 2013, 56: 35-40. 10.1503/cjs.012311.CrossRefPubMedPubMedCentral
20.
go back to reference Kim T, Ayturk UM, Haskell A, Miclau T, Puttlitz CM: Fixation of osteoporotic distal fibula fractures: a biomechanical comparison of locking versus conventional plates. J Foot Ankle Surg. 2007, 46: 2-6. 10.1053/j.jfas.2006.09.009.CrossRefPubMed Kim T, Ayturk UM, Haskell A, Miclau T, Puttlitz CM: Fixation of osteoporotic distal fibula fractures: a biomechanical comparison of locking versus conventional plates. J Foot Ankle Surg. 2007, 46: 2-6. 10.1053/j.jfas.2006.09.009.CrossRefPubMed
21.
go back to reference Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H: Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study. Injury. 1997, 28 (Suppl 1): A7-A12.CrossRefPubMed Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H: Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study. Injury. 1997, 28 (Suppl 1): A7-A12.CrossRefPubMed
22.
go back to reference Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H: Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique?. J Orthop Trauma. 1999, 13: 401-406. 10.1097/00005131-199908000-00002.CrossRefPubMed Farouk O, Krettek C, Miclau T, Schandelmaier P, Guy P, Tscherne H: Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique?. J Orthop Trauma. 1999, 13: 401-406. 10.1097/00005131-199908000-00002.CrossRefPubMed
23.
go back to reference Lau TW, Leung F, Chan CF, Chow SP: Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008, 32: 697-703. 10.1007/s00264-007-0384-z.CrossRefPubMed Lau TW, Leung F, Chan CF, Chow SP: Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008, 32: 697-703. 10.1007/s00264-007-0384-z.CrossRefPubMed
24.
25.
go back to reference Neubauer T, Heidari N, Weinberg AM, Grechenig W, Tesch NP, Pichler W, Wagner M: The risk of nerve injury with minimally invasive plate osteosynthesis of distal fibula fractures: an anatomic study. Arch Orthop Trauma Surg. 2011, 131: 1409-1412. 10.1007/s00402-011-1318-1.CrossRefPubMed Neubauer T, Heidari N, Weinberg AM, Grechenig W, Tesch NP, Pichler W, Wagner M: The risk of nerve injury with minimally invasive plate osteosynthesis of distal fibula fractures: an anatomic study. Arch Orthop Trauma Surg. 2011, 131: 1409-1412. 10.1007/s00402-011-1318-1.CrossRefPubMed
26.
go back to reference Schepers T, Van Lieshout EM, De Vries MR, Van der Elst M: Increased rates of wound complications with locking plates in distal fibular fractures. Injury. 2011, 42: 1125-1129. 10.1016/j.injury.2011.01.009.CrossRefPubMed Schepers T, Van Lieshout EM, De Vries MR, Van der Elst M: Increased rates of wound complications with locking plates in distal fibular fractures. Injury. 2011, 42: 1125-1129. 10.1016/j.injury.2011.01.009.CrossRefPubMed
27.
go back to reference Miller AG, Margules A, Raikin SM: Risk factors for wound complications after ankle fracture surgery. J Bone Joint Surg Am. 2012, 94: 2047-2052. 10.2106/JBJS.K.01088.CrossRefPubMed Miller AG, Margules A, Raikin SM: Risk factors for wound complications after ankle fracture surgery. J Bone Joint Surg Am. 2012, 94: 2047-2052. 10.2106/JBJS.K.01088.CrossRefPubMed
Metadata
Title
Comparison of three plate system for lateral malleolar fixation
Authors
ZeYu Huang
Lei Liu
ChongQi Tu
Hui Zhang
Yue Fang
TianFu Yang
FuXing Pei
Publication date
01-12-2014
Publisher
BioMed Central
Published in
BMC Musculoskeletal Disorders / Issue 1/2014
Electronic ISSN: 1471-2474
DOI
https://doi.org/10.1186/1471-2474-15-360

Other articles of this Issue 1/2014

BMC Musculoskeletal Disorders 1/2014 Go to the issue