Skip to main content
Top
Published in: BMC Oral Health 1/2013

Open Access 01-12-2013 | Research article

Comparison of the shaping ability of GT® Series X, Twisted Files and AlphaKite rotary nickel-titanium systems in simulated canals

Authors: Raidan Ba-Hattab, Anne-Kathrin Pröhl, Hermann Lang, Dieter Pahncke

Published in: BMC Oral Health | Issue 1/2013

Login to get access

Abstract

Background

Efforts to improve the performance of rotary NiTi instruments by enhancing the properties of NiTi alloy, or their manufacturing processes rather than changes in instrument geometries have been reported. The aim of this study was to compare in-vitro the shaping ability of three different rotary nickel-titanium instruments produced by different manufacturing methods.

Methods

Thirty simulated root canals with a curvature of 35˚ in resin blocks were prepared with three different rotary NiTi systems: AK- AlphaKite (Gebr. Brasseler, Germany), GTX- GT® Series X (Dentsply, Germany) and TF- Twisted Files (SybronEndo, USA).
The canals were prepared according to the manufacturers’ instructions. Pre- and post-instrumentation images were recorded and assessment of canal curvature modifications was carried out with an image analysis program (GSA, Germany).
The preparation time and incidence of procedural errors were recorded. Instruments were evaluated under a microscope with 15 × magnifications (Carl Zeiss OPMI Pro Ergo, Germany) for signs of deformation. The Data were statistically analyzed using SPSS (Wilcoxon and Mann–Whitney U-tests, at a confidence interval of 95%).

Results

Less canal transportation was produced by TF apically, although the difference among the groups was not statistically significant. GTX removed the greatest amount of resin from the middle and coronal parts of the canal and the difference among the groups was statistically significant (p < 0.05). The shortest preparation time was registered with TF (444 s) and the longest with GTX (714 s), the difference among the groups was statistically significant (p < 0.05). During the preparation of the canals no instrument fractured. Eleven instruments of TF and one of AK were deformed.

Conclusion

Under the conditions of this study, all rotary NiTi instruments maintained the working length and prepared a well-shaped root canal. The least canal transportation was produced by AK. GTX displayed the greatest cutting efficiency. TF prepared the canals faster than the other two systems.
Literature
1.
go back to reference American Association of Endodontists: Rotary Instrumentation: An Endodontic Perspective. 2008, Winter: Endodontics: Colleagues for Excellence, 8- American Association of Endodontists: Rotary Instrumentation: An Endodontic Perspective. 2008, Winter: Endodontics: Colleagues for Excellence, 8-
2.
go back to reference Hu XL, Ling JQ, Chen H, Gu HJ: Clinical evaluation of two types of NiTi rotary instruments in preparation of root canals [abstract]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2004, 40: 30-33. Hu XL, Ling JQ, Chen H, Gu HJ: Clinical evaluation of two types of NiTi rotary instruments in preparation of root canals [abstract]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2004, 40: 30-33.
3.
go back to reference Bergmans L, Cleynenbrugel JV, Wevers MP: Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American journal of dentistry. Am J Dent. 2001, 14: 324-333.PubMed Bergmans L, Cleynenbrugel JV, Wevers MP: Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American journal of dentistry. Am J Dent. 2001, 14: 324-333.PubMed
4.
go back to reference Ruddle CJ: The ProTaper technique. Endod Topics. 2005, 10: 187-190. 10.1111/j.1601-1546.2005.00115.x.CrossRef Ruddle CJ: The ProTaper technique. Endod Topics. 2005, 10: 187-190. 10.1111/j.1601-1546.2005.00115.x.CrossRef
5.
go back to reference Vaudt J, Bitter K, Kielbassa : Evaluation of rotary instruments in vitro. A review. ENDO. 2007, 1: 189-203. Vaudt J, Bitter K, Kielbassa : Evaluation of rotary instruments in vitro. A review. ENDO. 2007, 1: 189-203.
6.
go back to reference Koch K, Brave D: Real world Endo: design features of rotary files and how they affect clinical performance. Oral Health. 2002, 1: 39-49. Koch K, Brave D: Real world Endo: design features of rotary files and how they affect clinical performance. Oral Health. 2002, 1: 39-49.
7.
go back to reference Gambarini G, Grande N, Plotino G, Somme F, Garala M, De Luca M, Testarelli L: Fatigue resistance of engine–driven rotary nickel–titanium instruments produced by new manufacturing methods. J Endod. 2008, 34: 1003-1005. 10.1016/j.joen.2008.05.007.CrossRefPubMed Gambarini G, Grande N, Plotino G, Somme F, Garala M, De Luca M, Testarelli L: Fatigue resistance of engine–driven rotary nickel–titanium instruments produced by new manufacturing methods. J Endod. 2008, 34: 1003-1005. 10.1016/j.joen.2008.05.007.CrossRefPubMed
8.
go back to reference Pirani C, Ruggeri O, Cirulli PP, Pelliccioni GA, Gandolfi MG, Prati C: Metallurgical analysis and fatigue resistance of WaveOne and ProTaper nickel–titanium instruments. Odontology. 2013 Pirani C, Ruggeri O, Cirulli PP, Pelliccioni GA, Gandolfi MG, Prati C: Metallurgical analysis and fatigue resistance of WaveOne and ProTaper nickel–titanium instruments. Odontology. 2013
10.
go back to reference Larsen M, Watanabe I, Glickman N, He J: Cyclic fatigue analysis of a new generation of nickel-titanium rotary instruments. J Endod. 2009, 35: 401-403. 10.1016/j.joen.2008.12.010.CrossRefPubMed Larsen M, Watanabe I, Glickman N, He J: Cyclic fatigue analysis of a new generation of nickel-titanium rotary instruments. J Endod. 2009, 35: 401-403. 10.1016/j.joen.2008.12.010.CrossRefPubMed
11.
go back to reference Lee DH, Park JB, Saxena A, Serene TP: Enhanced surface hardness by boron implantation in Nitinol alloy. J Endod. 1996, 22: 43-46.CrossRef Lee DH, Park JB, Saxena A, Serene TP: Enhanced surface hardness by boron implantation in Nitinol alloy. J Endod. 1996, 22: 43-46.CrossRef
12.
go back to reference Schäfer E: Effect of sterilization on the cutting efficiency of PVD–coated nickel–titanium endodontic instruments. Int Endod J. 2002, 35: 867-872. 10.1046/j.1365-2591.2002.00586.x.CrossRefPubMed Schäfer E: Effect of sterilization on the cutting efficiency of PVD–coated nickel–titanium endodontic instruments. Int Endod J. 2002, 35: 867-872. 10.1046/j.1365-2591.2002.00586.x.CrossRefPubMed
13.
go back to reference Rapisarda E, Bonaccorso A, Tripi TR, Condorelli GG, Torrisi L: Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation. J Endod. 2001, 27: 588-592. 10.1097/00004770-200109000-00009.CrossRefPubMed Rapisarda E, Bonaccorso A, Tripi TR, Condorelli GG, Torrisi L: Wear of nickel-titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation. J Endod. 2001, 27: 588-592. 10.1097/00004770-200109000-00009.CrossRefPubMed
14.
go back to reference Pirani C, Cirulli PP, Chersoni S, Micele L, Ruggeri O, Prati C: Cyclic fatigue testing and metallographic analysis of nickel-titanium rotary instruments. J Endod. 2011, 37: 1013-1016. 10.1016/j.joen.2011.04.009.CrossRefPubMed Pirani C, Cirulli PP, Chersoni S, Micele L, Ruggeri O, Prati C: Cyclic fatigue testing and metallographic analysis of nickel-titanium rotary instruments. J Endod. 2011, 37: 1013-1016. 10.1016/j.joen.2011.04.009.CrossRefPubMed
15.
go back to reference Thompson SA, Dummer PMH: Shaping ability of ProFile.04 Taper Series 29 rotary nickel–titanium instruments in simulated canals. Part 1. Int Endod J. 1997, 30: 1-7. 10.1111/j.1365-2591.1997.tb01093.x.CrossRefPubMed Thompson SA, Dummer PMH: Shaping ability of ProFile.04 Taper Series 29 rotary nickel–titanium instruments in simulated canals. Part 1. Int Endod J. 1997, 30: 1-7. 10.1111/j.1365-2591.1997.tb01093.x.CrossRefPubMed
16.
go back to reference Schäfer E, Tepel J, Hoppe W: Properties of endodontic hand instruments used in rotary motion. Part2. Instrumentation of curved canals. J Endod. 1995, 21: 493-497. 10.1016/S0099-2399(06)80519-4.CrossRefPubMed Schäfer E, Tepel J, Hoppe W: Properties of endodontic hand instruments used in rotary motion. Part2. Instrumentation of curved canals. J Endod. 1995, 21: 493-497. 10.1016/S0099-2399(06)80519-4.CrossRefPubMed
17.
go back to reference Hülsmann M, Gressmann G, Schäfers F: A comparative study of root canal preparation using FlexMaster and HERO 642 rotary NiTi instruments. Int Endod J. 2003, 36: 358-366. 10.1046/j.1365-2591.2003.00664.x.CrossRefPubMed Hülsmann M, Gressmann G, Schäfers F: A comparative study of root canal preparation using FlexMaster and HERO 642 rotary NiTi instruments. Int Endod J. 2003, 36: 358-366. 10.1046/j.1365-2591.2003.00664.x.CrossRefPubMed
18.
go back to reference Vaudt J, Bitter K, Neumann K, Kielbassa AM: Ex vivo study on root canal instrumentation of two rotary nickel–titanium systems in comparison to stainless steel hand instruments. Int Endod J. 2009, 42: 22-33. 10.1111/j.1365-2591.2008.01489.x.CrossRefPubMed Vaudt J, Bitter K, Neumann K, Kielbassa AM: Ex vivo study on root canal instrumentation of two rotary nickel–titanium systems in comparison to stainless steel hand instruments. Int Endod J. 2009, 42: 22-33. 10.1111/j.1365-2591.2008.01489.x.CrossRefPubMed
19.
go back to reference Ayar LR, Love RM: Shaping ability of ProFile and K3 rotary Ni–Ti instruments when used in a variable tip sequence in simulated curved root canals. Int Endod J. 2004, 37: 593-601. 10.1111/j.1365-2591.2004.00851.x.CrossRefPubMed Ayar LR, Love RM: Shaping ability of ProFile and K3 rotary Ni–Ti instruments when used in a variable tip sequence in simulated curved root canals. Int Endod J. 2004, 37: 593-601. 10.1111/j.1365-2591.2004.00851.x.CrossRefPubMed
20.
go back to reference Setzer FC, Kwon TK, Karabucak B: Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences. J Endod. 2010, 36: 1226-1229. 10.1016/j.joen.2010.03.011.CrossRefPubMed Setzer FC, Kwon TK, Karabucak B: Comparison of apical transportation between two rotary file systems and two hybrid rotary instrumentation sequences. J Endod. 2010, 36: 1226-1229. 10.1016/j.joen.2010.03.011.CrossRefPubMed
21.
go back to reference Gergi R, Abou Rjeily J, Sader J, Naaman : A comparison of canal transportation and centering ability of Twisted Files, Pathfile–ProTaper system, and stainless steel hand K–files by using computed tomography. J Endod. 2010, 36: 904-907. 10.1016/j.joen.2009.12.038.CrossRefPubMed Gergi R, Abou Rjeily J, Sader J, Naaman : A comparison of canal transportation and centering ability of Twisted Files, Pathfile–ProTaper system, and stainless steel hand K–files by using computed tomography. J Endod. 2010, 36: 904-907. 10.1016/j.joen.2009.12.038.CrossRefPubMed
22.
go back to reference Fayyad D, Elgendy A: Cutting efficiency of twisted versus machined nickel–titanium endodontic files. J Endod. 2011, 37: 1143-1146. 10.1016/j.joen.2011.03.036.CrossRefPubMed Fayyad D, Elgendy A: Cutting efficiency of twisted versus machined nickel–titanium endodontic files. J Endod. 2011, 37: 1143-1146. 10.1016/j.joen.2011.03.036.CrossRefPubMed
23.
go back to reference El Batouty KM, Elmallah WE: Comparison of canal transportation and changes in canal curvature of two nickel–titanium rotary instruments. J Endod. 2011, 37: 1290-1292. 10.1016/j.joen.2011.05.024.CrossRefPubMed El Batouty KM, Elmallah WE: Comparison of canal transportation and changes in canal curvature of two nickel–titanium rotary instruments. J Endod. 2011, 37: 1290-1292. 10.1016/j.joen.2011.05.024.CrossRefPubMed
24.
go back to reference Buchanan S: The technique for GT Series X rotary shaping files. Endo Tribune U.S. 2007, 12: 8-9. Buchanan S: The technique for GT Series X rotary shaping files. Endo Tribune U.S. 2007, 12: 8-9.
25.
go back to reference Tabtabaei: PhD thesis. Evaluation of canal instrumentation using GT series X versus ProSystem GT. 2011, Vancouver, Canada: The University of British Columbia, the Faculty of Graduate Studies Tabtabaei: PhD thesis. Evaluation of canal instrumentation using GT series X versus ProSystem GT. 2011, Vancouver, Canada: The University of British Columbia, the Faculty of Graduate Studies
26.
go back to reference Hashem A, Ghoneim A, Lutfy R, Foda M, Omer G: Geometric analysis of root canals prepared by four rotary NiTi shaping systems. J Endod. 2012, 38: 996-1000. 10.1016/j.joen.2012.03.018.CrossRefPubMed Hashem A, Ghoneim A, Lutfy R, Foda M, Omer G: Geometric analysis of root canals prepared by four rotary NiTi shaping systems. J Endod. 2012, 38: 996-1000. 10.1016/j.joen.2012.03.018.CrossRefPubMed
27.
go back to reference Al–dameh A: PhD Thesis. Root Canal Preparation with two Different Rotary Systems: Comparative Study Assessed by Micro–Computed Tomography. 2011, Dunedin, New Zealand: University of Otago Al–dameh A: PhD Thesis. Root Canal Preparation with two Different Rotary Systems: Comparative Study Assessed by Micro–Computed Tomography. 2011, Dunedin, New Zealand: University of Otago
28.
go back to reference Young GR, Parashos P, Messer HH: The principles of techniques for cleaning root canals. Aust Dent J. 2007, 52: 52-63.CrossRef Young GR, Parashos P, Messer HH: The principles of techniques for cleaning root canals. Aust Dent J. 2007, 52: 52-63.CrossRef
29.
go back to reference Lev R, Reader A, Beck M, Meyers W: An in vitro comparison of the stepback technique versus a stepback ultrasonic technique for 1 and 3 minutes. J Endod. 1987, 13: 523-530. 10.1016/S0099-2399(87)80031-6.CrossRefPubMed Lev R, Reader A, Beck M, Meyers W: An in vitro comparison of the stepback technique versus a stepback ultrasonic technique for 1 and 3 minutes. J Endod. 1987, 13: 523-530. 10.1016/S0099-2399(87)80031-6.CrossRefPubMed
30.
go back to reference Marending M, Lutz F, Barbakow F: Scanning electron microscope appearances of Lightspeed instruments used clinically: a pilot study. Int Endod J. 1998, 31: 57-62. 10.1046/j.1365-2591.1998.t01-1-00104.x.CrossRefPubMed Marending M, Lutz F, Barbakow F: Scanning electron microscope appearances of Lightspeed instruments used clinically: a pilot study. Int Endod J. 1998, 31: 57-62. 10.1046/j.1365-2591.1998.t01-1-00104.x.CrossRefPubMed
31.
go back to reference Testarelli L, Grande NM, Plotino G, Lendini M, Pongione G, Paolis G, Rizzo F, Milana V, Gambarini G: Cyclic fatigue of different nickel–titanium rotary instruments: a comparative study. Open Dent J. 2009, 3: 55-58. 10.2174/1874210600903010055.CrossRefPubMedPubMedCentral Testarelli L, Grande NM, Plotino G, Lendini M, Pongione G, Paolis G, Rizzo F, Milana V, Gambarini G: Cyclic fatigue of different nickel–titanium rotary instruments: a comparative study. Open Dent J. 2009, 3: 55-58. 10.2174/1874210600903010055.CrossRefPubMedPubMedCentral
32.
go back to reference Kim HC, Yum J, Hur B, Cheung GSP: Cyclic fatigue and fracture characteristics of ground and twisted nickel–titanium rotary files. J Endod. 2010, 36: 147-152. 10.1016/j.joen.2009.09.037.CrossRefPubMed Kim HC, Yum J, Hur B, Cheung GSP: Cyclic fatigue and fracture characteristics of ground and twisted nickel–titanium rotary files. J Endod. 2010, 36: 147-152. 10.1016/j.joen.2009.09.037.CrossRefPubMed
33.
go back to reference Gupta M, Mulay S: Evaluation of cyclic fatigue resistance of three rotary nickel-titanium endodontic instruments in curved canals– In vitro study. Endodontology. 2010, 22: 14-18. Gupta M, Mulay S: Evaluation of cyclic fatigue resistance of three rotary nickel-titanium endodontic instruments in curved canals– In vitro study. Endodontology. 2010, 22: 14-18.
34.
go back to reference Pedullà E, Grande NM, Plotino G, Pappalardo A, Rapisarda E: Cyclic fatigue resistance of three different nickel–titanium instruments after immersion in sodium hypochlorite. J Endod. 2011, 37: 1139-1142. 10.1016/j.joen.2011.04.008.CrossRefPubMed Pedullà E, Grande NM, Plotino G, Pappalardo A, Rapisarda E: Cyclic fatigue resistance of three different nickel–titanium instruments after immersion in sodium hypochlorite. J Endod. 2011, 37: 1139-1142. 10.1016/j.joen.2011.04.008.CrossRefPubMed
Metadata
Title
Comparison of the shaping ability of GT® Series X, Twisted Files and AlphaKite rotary nickel-titanium systems in simulated canals
Authors
Raidan Ba-Hattab
Anne-Kathrin Pröhl
Hermann Lang
Dieter Pahncke
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2013
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/1472-6831-13-72

Other articles of this Issue 1/2013

BMC Oral Health 1/2013 Go to the issue