Skip to main content
Top
Published in: International Ophthalmology 6/2015

01-12-2015 | Original Paper

Comparison of the current and a new RTVue OCT software version for detection of ganglion cell complex changes due to cataract surgery

Authors: Gábor Holló, Farzaneh Naghizadeh, Sofia Hsu, Tamás Filkorn, Mária Bausz

Published in: International Ophthalmology | Issue 6/2015

Login to get access

Abstract

The purpose was to compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue OCT) for ganglion cell complex (GCC) and retinal nerve fibre layer thickness (RNFLT) changes after phacoemulsification in healthy cataract eyes, and to investigate whether version 6.12, in which image segmentation is improved, provides benefits over version 6.3 for RNFLT and GCC imaging via mild cataract. One eye of 22 consecutive healthy cataract patients were imaged before and 1 month after uncomplicated cataract surgery using RTVue-100 OCT software version 6.3. The images were analysed with both software versions. Signal strength index increased significantly after surgery for both RNFLT and the GCC measurements (p ≤ 0.0015). No difference was seen for any RNFLT parameter between the software versions and time points (p ≥ 0.0140). The GCC values did not differ between the versions either before or after surgery (p ≥ 0.4471), but all increased significantly after surgery with software version 6.12 (p < 0.0001). Neither focal loss volume (FLV) nor global loss volume (GLV) differed between the software versions before and after surgery, respectively, but GLV decreased (improved) significantly after surgery (p = 0.010 and <0.001 for versions 6.3 and 6.12, respectively). Cataract surgery induced similar changes with both software versions, but version 6.12 identified the increase of GCC thickness and the decrease of GLV better than the current version. Although no significant difference between software versions was seen before surgery, our results suggest that version 6.12 may be more precise in measuring GCC parameters than the currently available version.
Literature
1.
go back to reference Sung M-S, Yoon J-H, Park S-W (2013) Diagnostic validity of macular ganglion cell-inner plexiform layer thickness deviation map algorithm using cirrus HD-OCT in preperimetric and early glaucoma. J Glaucoma. doi:10.1097/IJG.0000000000000028 PubMed Sung M-S, Yoon J-H, Park S-W (2013) Diagnostic validity of macular ganglion cell-inner plexiform layer thickness deviation map algorithm using cirrus HD-OCT in preperimetric and early glaucoma. J Glaucoma. doi:10.​1097/​IJG.​0000000000000028​ PubMed
2.
go back to reference Nakatani Y, Higashide T, Ohkubo S et al (2011) Evaluation of macular thickness and peripapillary retinal nerve fiber layer thickness for detection of early glaucoma using spectral domain optical coherence tomography. J Glaucoma 20:252–259CrossRefPubMed Nakatani Y, Higashide T, Ohkubo S et al (2011) Evaluation of macular thickness and peripapillary retinal nerve fiber layer thickness for detection of early glaucoma using spectral domain optical coherence tomography. J Glaucoma 20:252–259CrossRefPubMed
3.
go back to reference Garas A, Vargha P, Holló G (2011) Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma. Eye 25:57–65PubMedCentralCrossRefPubMed Garas A, Vargha P, Holló G (2011) Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma. Eye 25:57–65PubMedCentralCrossRefPubMed
5.
go back to reference Kim NR, Lee EK, Seong GJ et al (2011) Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol 95:1115–1121CrossRefPubMed Kim NR, Lee EK, Seong GJ et al (2011) Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia. Br J Ophthalmol 95:1115–1121CrossRefPubMed
6.
go back to reference Mori S, Hangai M, Sakamoto A, Yoshimura N (2010) Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J Glaucoma 19:528–534CrossRefPubMed Mori S, Hangai M, Sakamoto A, Yoshimura N (2010) Spectral-domain optical coherence tomography measurement of macular volume for diagnosing glaucoma. J Glaucoma 19:528–534CrossRefPubMed
7.
go back to reference Nouri-Mahdavi K, Nowroozizadeh S, Nassiri N et al (2013) Macular ganglion cell/inner plexiform layer measurements by spectral domain optical coherence tomography for detection of early glaucoma and comparison to retinal nerve fiber layer measurements. Am J Ophthalmol 156:1297–1307CrossRefPubMed Nouri-Mahdavi K, Nowroozizadeh S, Nassiri N et al (2013) Macular ganglion cell/inner plexiform layer measurements by spectral domain optical coherence tomography for detection of early glaucoma and comparison to retinal nerve fiber layer measurements. Am J Ophthalmol 156:1297–1307CrossRefPubMed
8.
go back to reference Choi YJ, Jeoung JW, Park KH, Kim DM (2013) Glaucoma detection ability of ganglion cell-inner plexiform layer thickness by spectral-domain optical coherence tomography in high myopia. Invest Ophthalmol Vis Sci 54:2296–2304CrossRefPubMed Choi YJ, Jeoung JW, Park KH, Kim DM (2013) Glaucoma detection ability of ganglion cell-inner plexiform layer thickness by spectral-domain optical coherence tomography in high myopia. Invest Ophthalmol Vis Sci 54:2296–2304CrossRefPubMed
9.
go back to reference Tan O, Chopra V, Lu AT et al (2009) Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography. Ophthalmology 116:2305–2314PubMedCentralCrossRefPubMed Tan O, Chopra V, Lu AT et al (2009) Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography. Ophthalmology 116:2305–2314PubMedCentralCrossRefPubMed
10.
go back to reference Seong M, Sung KR, Choi EH et al (2010) Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma. Invest Ophthalmol Vis Sci 51:1446–1452CrossRefPubMed Seong M, Sung KR, Choi EH et al (2010) Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma. Invest Ophthalmol Vis Sci 51:1446–1452CrossRefPubMed
11.
go back to reference Naghizadeh F, Garas A, Vargha P, Holló G (2014) Detection of early glaucomatous progression with different parameters of the RTVue optical coherence tomograph. J Glaucoma 23:195–198CrossRefPubMed Naghizadeh F, Garas A, Vargha P, Holló G (2014) Detection of early glaucomatous progression with different parameters of the RTVue optical coherence tomograph. J Glaucoma 23:195–198CrossRefPubMed
12.
go back to reference Sung KR, Sun JH, Na JH et al (2012) Progression detection capability of macular thickness in advanced glaucomatous eyes. Ophthalmology 119:308–313CrossRefPubMed Sung KR, Sun JH, Na JH et al (2012) Progression detection capability of macular thickness in advanced glaucomatous eyes. Ophthalmology 119:308–313CrossRefPubMed
13.
go back to reference Bambo PM, Garcia-Martin E, Otin S et al (2014) Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography. Br J Ophthalmol 98:52–58CrossRefPubMed Bambo PM, Garcia-Martin E, Otin S et al (2014) Influence of cataract surgery on repeatability and measurements of spectral domain optical coherence tomography. Br J Ophthalmol 98:52–58CrossRefPubMed
14.
go back to reference Kim NR, Lee H, Lee ES et al (2012) Influence of cataract on time domain and spectral domain optical coherence tomography retinal nerve fiber layer measurements. J Glaucoma 21:116–122PubMed Kim NR, Lee H, Lee ES et al (2012) Influence of cataract on time domain and spectral domain optical coherence tomography retinal nerve fiber layer measurements. J Glaucoma 21:116–122PubMed
15.
go back to reference Garcia-Martin E, Fernandez J, Gil-Arribas L et al (2013) Effect of cataract surgery on optical coherence tomography measurements and repeatability in patients with non-insulin-dependent diabetes mellitus. Invest Ophthalmol Vis Sci 54:5303–5312CrossRefPubMed Garcia-Martin E, Fernandez J, Gil-Arribas L et al (2013) Effect of cataract surgery on optical coherence tomography measurements and repeatability in patients with non-insulin-dependent diabetes mellitus. Invest Ophthalmol Vis Sci 54:5303–5312CrossRefPubMed
16.
go back to reference Mwanza JC, Bhorade AM, Sekhon N et al (2011) Effect of cataract and its removal on signal strength and peripapillary retinal nerve fiber layer optical coherence tomography measurements. J Glaucoma 20:37–43CrossRefPubMed Mwanza JC, Bhorade AM, Sekhon N et al (2011) Effect of cataract and its removal on signal strength and peripapillary retinal nerve fiber layer optical coherence tomography measurements. J Glaucoma 20:37–43CrossRefPubMed
17.
go back to reference Sánchez-Cano A, Pablo LE, Larossa JM et al (2010) The effect of phacoemulsification cataract surgery on polarimetry and tomography measurements for glaucoma diagnosis. J Glaucoma 19:468–474CrossRefPubMed Sánchez-Cano A, Pablo LE, Larossa JM et al (2010) The effect of phacoemulsification cataract surgery on polarimetry and tomography measurements for glaucoma diagnosis. J Glaucoma 19:468–474CrossRefPubMed
18.
go back to reference Georgopoulos GT, Papaconstantinou D, Niskopoulo M et al (2008) Foveal thickness after phacoemulsification as measured by optical coherence tomography. Clin Ophthalmol 2:817–820PubMedCentralPubMed Georgopoulos GT, Papaconstantinou D, Niskopoulo M et al (2008) Foveal thickness after phacoemulsification as measured by optical coherence tomography. Clin Ophthalmol 2:817–820PubMedCentralPubMed
19.
go back to reference Stock G, Ahlers C, Dunavoelgyi R et al (2011) Evaluation of anterior-segment inflammation and retinal thickness change following cataract surgery. Acta Ophthalmol 89:369–375CrossRefPubMed Stock G, Ahlers C, Dunavoelgyi R et al (2011) Evaluation of anterior-segment inflammation and retinal thickness change following cataract surgery. Acta Ophthalmol 89:369–375CrossRefPubMed
20.
go back to reference Biro Z, Balla Z, Kovacs B (2008) Change of foveal and perifoveal thickness measured by OCT after phacoemulsification and IOL implantation. Eye 22:8–12CrossRefPubMed Biro Z, Balla Z, Kovacs B (2008) Change of foveal and perifoveal thickness measured by OCT after phacoemulsification and IOL implantation. Eye 22:8–12CrossRefPubMed
21.
go back to reference Ecsedi M, Miháltz K, Kovács I et al (2011) Effect of femtosecond laser cataract surgery on the macula. J Refract Surg 27:717–722CrossRef Ecsedi M, Miháltz K, Kovács I et al (2011) Effect of femtosecond laser cataract surgery on the macula. J Refract Surg 27:717–722CrossRef
22.
go back to reference Garas A, Vargha P, Holló G (2010) Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomography. Ophthalmology 117:738–746CrossRefPubMed Garas A, Vargha P, Holló G (2010) Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomography. Ophthalmology 117:738–746CrossRefPubMed
23.
go back to reference Optovue Inc. (2011) User’s manual for users only outside the United States to RTVue 100 OCT version 6.3, 09/2011 Optovue Inc. (2011) User’s manual for users only outside the United States to RTVue 100 OCT version 6.3, 09/2011
24.
go back to reference Holló G, Naghizadeh F (2015) Influence of a new software version of the RTVue-100 optical coherence tomograph on ganglion cell complex segmentation in various forms of age-related macular degeneration. J Glaucoma 24:245–250 Holló G, Naghizadeh F (2015) Influence of a new software version of the RTVue-100 optical coherence tomograph on ganglion cell complex segmentation in various forms of age-related macular degeneration. J Glaucoma 24:245–250
Metadata
Title
Comparison of the current and a new RTVue OCT software version for detection of ganglion cell complex changes due to cataract surgery
Authors
Gábor Holló
Farzaneh Naghizadeh
Sofia Hsu
Tamás Filkorn
Mária Bausz
Publication date
01-12-2015
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 6/2015
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-015-0064-8

Other articles of this Issue 6/2015

International Ophthalmology 6/2015 Go to the issue