Skip to main content
Top
Published in: EJNMMI Research 1/2017

Open Access 01-12-2017 | Original research

Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer

Authors: Michael K. O’Connor, Melissa M. B. Morrow, Katie N. Hunt, Judy C. Boughey, Dietlind L. Wahner-Roedler, Amy Lynn Conners, Deborah J. Rhodes, Carrie B. Hruska

Published in: EJNMMI Research | Issue 1/2017

Login to get access

Abstract

Background

Molecular breast imaging (MBI) performed with 99mTc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99mTc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99mTc sestamibi and 99mTc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations—one with 99mTc sestamibi and one with 99mTc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1–5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis.

Results

Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99mTc sestamibi MBI and 19 of 21 (90%) were seen on 99mTc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size (99mTc sestamibi, r = 0.84; 99mTc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99mTc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99mTc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99mTc sestamibi (r s  = 0.12, p = 0.63) or 99mTc maraciclatide (r s  = −0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99mTc sestamibi and 9 of 20 (45%) were seen on 99mTc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99mTc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99mTc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC analysis was 0.83 for 99mTc sestamibi and 0.87 for 99mTc maraciclatide (p = 0.64).

Conclusions

99mTc maraciclatide offered comparable lesion uptake to 99mTc sestamibi, in both malignant and benign lesions. There was good correlation between lesion extent and uptake measured from both radiopharmaceuticals. 99mTc maraciclatide offered a marginal (but not significant) improvement in sensitivity over 99mTc sestamibi. Our findings did not support an association between the uptake of either radiopharmaceutical and tumor molecular subtype.

Trial registration

ClinicalTrials.gov, NCT00888589
Literature
1.
2.
go back to reference Spanu A, Dettori G, Nuvoli S, Porcu A, Falchi A, Cottu P, et al. (99)mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis. Eur J Nucl Med. 2001;28:1781–94. doi:10.1007/s00259-001-0657-5.CrossRefPubMed Spanu A, Dettori G, Nuvoli S, Porcu A, Falchi A, Cottu P, et al. (99)mTc-tetrofosmin SPET in the detection of both primary breast cancer and axillary lymph node metastasis. Eur J Nucl Med. 2001;28:1781–94. doi:10.​1007/​s00259-001-0657-5.CrossRefPubMed
3.
go back to reference Kim IJ, Kim SJ, Kim YK. Comparison of double phase Tc-99m MIBI and Tc-99m tetrofosmin scintimammography for characterization of breast lesions: visual and quantitative analyses. Neoplasma. 2008;55:526–31.PubMed Kim IJ, Kim SJ, Kim YK. Comparison of double phase Tc-99m MIBI and Tc-99m tetrofosmin scintimammography for characterization of breast lesions: visual and quantitative analyses. Neoplasma. 2008;55:526–31.PubMed
4.
go back to reference Papantoniou V, Christodoulidou J, Papadaki E, Valotassiou V, Stipsanelli A, Louvrou A, et al. 99mTc-(V)DMSA scintimammography in the assessment of breast lesions: comparative study with 99mTc-MIBI. Eur J Nucl Med. 2001;28:923–8.CrossRefPubMed Papantoniou V, Christodoulidou J, Papadaki E, Valotassiou V, Stipsanelli A, Louvrou A, et al. 99mTc-(V)DMSA scintimammography in the assessment of breast lesions: comparative study with 99mTc-MIBI. Eur J Nucl Med. 2001;28:923–8.CrossRefPubMed
5.
go back to reference Arslan N, Ozturk E, Ilgan S, Narin Y, Dundar S, Tufan T, et al. The comparison of dual phase Tc-99m MIBI and tc-99m MDP scintimammography in the evaluation of breast masses: preliminary report. Ann Nucl Med. 2000;14:39–46.CrossRefPubMed Arslan N, Ozturk E, Ilgan S, Narin Y, Dundar S, Tufan T, et al. The comparison of dual phase Tc-99m MIBI and tc-99m MDP scintimammography in the evaluation of breast masses: preliminary report. Ann Nucl Med. 2000;14:39–46.CrossRefPubMed
7.
go back to reference Bernard BF, Krenning EP, Breeman WA, Ensing G, Benjamins H, Bakker WH, et al. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo. Nucl Med Biol. 1998;25:233–40.CrossRefPubMed Bernard BF, Krenning EP, Breeman WA, Ensing G, Benjamins H, Bakker WH, et al. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo. Nucl Med Biol. 1998;25:233–40.CrossRefPubMed
8.
go back to reference Conners AL, Jones KN, Hruska CB, Geske JR, Boughey JC, Rhodes DJ. Direct-conversion molecular breast imaging of invasive breast cancer: imaging features, extent of invasive disease, and comparison between invasive ductal and lobular histology. Am J Roentgenol. 2015;205:W374–81. doi:10.2214/ajr.14.13502.CrossRef Conners AL, Jones KN, Hruska CB, Geske JR, Boughey JC, Rhodes DJ. Direct-conversion molecular breast imaging of invasive breast cancer: imaging features, extent of invasive disease, and comparison between invasive ductal and lobular histology. Am J Roentgenol. 2015;205:W374–81. doi:10.​2214/​ajr.​14.​13502.CrossRef
10.
go back to reference Rak J. Angiogenesis. In: Tannock IF, Hill RP, Bristow RG, Harrington L, editors. The basic science of oncology. 5e ed. New York: McGraw-Hill; 2013. Rak J. Angiogenesis. In: Tannock IF, Hill RP, Bristow RG, Harrington L, editors. The basic science of oncology. 5e ed. New York: McGraw-Hill; 2013.
13.
go back to reference Brooks PC, Clark RA, Cheresh DA. Requirement of vascular integrin alpha v beta 3 for angiogenesis. Science. 1994;264:569–71.CrossRefPubMed Brooks PC, Clark RA, Cheresh DA. Requirement of vascular integrin alpha v beta 3 for angiogenesis. Science. 1994;264:569–71.CrossRefPubMed
14.
go back to reference Line BR, Mitra A, Nan A, Ghandehari H. Targeting tumor angiogenesis: comparison of peptide and polymer-peptide conjugates. J Nucl Med. 2005;46:1552–60.PubMed Line BR, Mitra A, Nan A, Ghandehari H. Targeting tumor angiogenesis: comparison of peptide and polymer-peptide conjugates. J Nucl Med. 2005;46:1552–60.PubMed
16.
go back to reference Bach-Gansmo T, Danielsson R, Saracco A, Wilczek B, Bogsrud TV, Fangberget A, et al. Integrin receptor imaging of breast cancer: a proof-of-concept study to evaluate 99mTc-NC100692. J Nucl Med. 2006;47:1434–9.PubMed Bach-Gansmo T, Danielsson R, Saracco A, Wilczek B, Bogsrud TV, Fangberget A, et al. Integrin receptor imaging of breast cancer: a proof-of-concept study to evaluate 99mTc-NC100692. J Nucl Med. 2006;47:1434–9.PubMed
18.
go back to reference Sickles EA, D’Orsi CJ, Bassett LW. ACR BI-RADS® mammography. In: ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System. 5th ed. Reston: American College of Radiology; 2013. Sickles EA, D’Orsi CJ, Bassett LW. ACR BI-RADS® mammography. In: ACR BI-RADS® Atlas, Breast Imaging Reporting and Data System. 5th ed. Reston: American College of Radiology; 2013.
20.
go back to reference Hruska CB, Weinmann AL, O’Connor MK. Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms. Med Phys. 2012;39:3466–75.CrossRefPubMedPubMedCentral Hruska CB, Weinmann AL, O’Connor MK. Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part I. Evaluation in phantoms. Med Phys. 2012;39:3466–75.CrossRefPubMedPubMedCentral
21.
go back to reference Hruska CB, Weinmann AL, Tello Skjerseth CM, Wagenaar EM, Conners AL, Tortorelli CL, et al. Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part II. Evaluation in patients. Med Phys. 2012;39:3476–83. doi:10.1118/1.4719959.CrossRefPubMedPubMedCentral Hruska CB, Weinmann AL, Tello Skjerseth CM, Wagenaar EM, Conners AL, Tortorelli CL, et al. Proof of concept for low-dose molecular breast imaging with a dual-head CZT gamma camera. Part II. Evaluation in patients. Med Phys. 2012;39:3476–83. doi:10.​1118/​1.​4719959.CrossRefPubMedPubMedCentral
22.
23.
go back to reference Conners AL, Hruska CB, Tortorelli CL, Maxwell RW, Rhodes DJ, Boughey JC, et al. Lexicon for standardized interpretation of gamma camera molecular breast imaging: observer agreement and diagnostic accuracy. Eur J Nucl Med Mol Imaging. 2012;39:971–82. doi:10.1007/s00259-011-2054-z.CrossRefPubMed Conners AL, Hruska CB, Tortorelli CL, Maxwell RW, Rhodes DJ, Boughey JC, et al. Lexicon for standardized interpretation of gamma camera molecular breast imaging: observer agreement and diagnostic accuracy. Eur J Nucl Med Mol Imaging. 2012;39:971–82. doi:10.​1007/​s00259-011-2054-z.CrossRefPubMed
26.
go back to reference Kit for the preparation of technetium Tc 99m sestamibi injection package insert. Hazelwood: Mallinckrodt Inc; 2006. Kit for the preparation of technetium Tc 99m sestamibi injection package insert. Hazelwood: Mallinckrodt Inc; 2006.
27.
go back to reference Rhodes DJ, Hruska CB, Conners AL, Tortorelli CL, Maxwell RW, Jones KN, et al. Journal club: molecular breast imaging at reduced radiation dose for supplemental screening in mammographically dense breasts. Am J Roentgenol. 2015;204:241–51. doi:10.2214/ajr.14.13357.CrossRef Rhodes DJ, Hruska CB, Conners AL, Tortorelli CL, Maxwell RW, Jones KN, et al. Journal club: molecular breast imaging at reduced radiation dose for supplemental screening in mammographically dense breasts. Am J Roentgenol. 2015;204:241–51. doi:10.​2214/​ajr.​14.​13357.CrossRef
28.
go back to reference Shermis RB, Wilson KD, Doyle MT, Martin TS, Merryman D, Kudrolli H, et al. Supplemental breast cancer screening with molecular breast imaging for women with dense breast tissue. Am J Roentgenol. 2016:1-8. doi:10.2214/AJR.15.15924. Shermis RB, Wilson KD, Doyle MT, Martin TS, Merryman D, Kudrolli H, et al. Supplemental breast cancer screening with molecular breast imaging for women with dense breast tissue. Am J Roentgenol. 2016:1-8. doi:10.​2214/​AJR.​15.​15924.
31.
go back to reference Piwnica-Worms D, Holman BL. Noncardiac applications of hexakis(alkylisonitrile) technetium-99m complexes. J Nucl Med. 1990;31:1166–7.PubMed Piwnica-Worms D, Holman BL. Noncardiac applications of hexakis(alkylisonitrile) technetium-99m complexes. J Nucl Med. 1990;31:1166–7.PubMed
32.
33.
go back to reference Hruska CB, Phillips SW, Whaley DH, Rhodes DJ, O’Connor MK. Molecular breast imaging: use of a dual-head dedicated gamma camera to detect small breast tumors. AJR Am J Roentgenol. 2008;191:1805–15. doi:10.2214/AJR.07.3693.CrossRefPubMed Hruska CB, Phillips SW, Whaley DH, Rhodes DJ, O’Connor MK. Molecular breast imaging: use of a dual-head dedicated gamma camera to detect small breast tumors. AJR Am J Roentgenol. 2008;191:1805–15. doi:10.​2214/​AJR.​07.​3693.CrossRefPubMed
34.
go back to reference NC100692 Kit (for the preparation of technetium (99mTc) NC100692 injection) [package insert]. 3.0 ed. Little Chalfont, Buckinghamshire: GE Healthcare Limited. NC100692 Kit (for the preparation of technetium (99mTc) NC100692 injection) [package insert]. 3.0 ed. Little Chalfont, Buckinghamshire: GE Healthcare Limited.
36.
go back to reference Mitchell D, Hruska CB, Boughey JC, Wahner-Roedler DL, Jones KN, Tortorelli C, et al. 99mTc-sestamibi using a direct conversion molecular breast imaging system to assess tumor response to neoadjuvant chemotherapy in women with locally advanced breast cancer. Clin Nucl Med. 2013;38:949–56. doi:10.1097/RLU.0000000000000248.CrossRefPubMedPubMedCentral Mitchell D, Hruska CB, Boughey JC, Wahner-Roedler DL, Jones KN, Tortorelli C, et al. 99mTc-sestamibi using a direct conversion molecular breast imaging system to assess tumor response to neoadjuvant chemotherapy in women with locally advanced breast cancer. Clin Nucl Med. 2013;38:949–56. doi:10.​1097/​RLU.​0000000000000248​.CrossRefPubMedPubMedCentral
Metadata
Title
Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer
Authors
Michael K. O’Connor
Melissa M. B. Morrow
Katie N. Hunt
Judy C. Boughey
Dietlind L. Wahner-Roedler
Amy Lynn Conners
Deborah J. Rhodes
Carrie B. Hruska
Publication date
01-12-2017
Publisher
Springer Berlin Heidelberg
Published in
EJNMMI Research / Issue 1/2017
Electronic ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-017-0255-6

Other articles of this Issue 1/2017

EJNMMI Research 1/2017 Go to the issue