Skip to main content
Top
Published in: Hernia 1/2008

01-02-2008 | Original Article

Comparison of recurrence with lightweight composite polypropylene mesh and heavyweight mesh in laparoscopic totally extraperitoneal inguinal hernia repair: an audit of 1,232 repairs

Authors: D. Akolekar, S. Kumar, L. R. Khan, A. C. de Beaux, S. J. Nixon

Published in: Hernia | Issue 1/2008

Login to get access

Abstract

Background

In Edinburgh a group of surgeons agreed to convert to a lightweight, composite mesh (Ultrapro—Ethicon) for totally extraperitoneal (TEP) inguinal hernia surgery. The aim of this study was to compare the outcome following the use of a new lightweight vs a standard heavyweight mesh during TEP hernia repair.

Methods

Patients undergoing TEP using lightweight (LWM) or heavyweight meshes (HWM) between March 2004 and March 2006 were identified from the Lothian Surgical Audit database. The patients who re-presented with recurrence of hernia were studied in greater detail. Date of re-attendance at a clinic with recurrence was used as a surrogate for date of recurrence.

Results

Two hundred and fifty one patients had 371 hernia repairs with LWM. A total of 16 (4.3%) recurred with a median follow-up of 14.5 months. A concurrent group of 326 patients had 425 repairs with standard mesh and have had 12 (2.82%) recurrences with a median follow-up of 22.4 months. A group of patients operated immediately prior to the introduction of LWM consisted of 328 patients who had 436 repairs using HWM, of whom 13 (2.98%) have recurred with a median follow-up of 43 months. Whilst there are no statistically significant differences in recurrence rates between these groups, we are concerned that the LWM group has the highest recurrence rate despite the shortest follow-up.

Conclusion

In view of increased patient comfort, we continue to recommend LWM for laparoscopic inguinal hernia surgery but would recommend that, in larger hernias and possibly for all, the surgeon should improve mesh adhesion.
Literature
1.
go back to reference Khan LR, Kumar S, Nixon SJ (2006) Early results for new lightweight mesh in laparoscopic totally extra-peritoneal inguinal hernia repair. Hernia 10:303–308PubMedCrossRef Khan LR, Kumar S, Nixon SJ (2006) Early results for new lightweight mesh in laparoscopic totally extra-peritoneal inguinal hernia repair. Hernia 10:303–308PubMedCrossRef
2.
go back to reference Bringman S, Wollert S, Ostgerberg J, Heikkinen T (2005) Early results of a randomized multicenter trial comparing Prolene and VyproII mesh in bilateral endoscopic extraperitoneal hernioplasty (TEP). Surg Endosc 19:536–540PubMedCrossRef Bringman S, Wollert S, Ostgerberg J, Heikkinen T (2005) Early results of a randomized multicenter trial comparing Prolene and VyproII mesh in bilateral endoscopic extraperitoneal hernioplasty (TEP). Surg Endosc 19:536–540PubMedCrossRef
3.
go back to reference Post S, Weiss B, Willer M, Neufang T, Lorenz D (2004) Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg 91:44–48PubMedCrossRef Post S, Weiss B, Willer M, Neufang T, Lorenz D (2004) Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair. Br J Surg 91:44–48PubMedCrossRef
4.
go back to reference Bringman S, Wollert S, Osterberg J, Smedberg S, Granlund H, Heikkinen TJ (2006) Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg 93:1056–1059PubMedCrossRef Bringman S, Wollert S, Osterberg J, Smedberg S, Granlund H, Heikkinen TJ (2006) Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg 93:1056–1059PubMedCrossRef
5.
go back to reference Puccio F, Solazzo M, Marciano P (2005) Comparison of three different mesh materials in tension-free inguinal hernia repair: prolene versus Vypro versus surgisis. Int Surg 90(3 Suppl):S21–S23 Puccio F, Solazzo M, Marciano P (2005) Comparison of three different mesh materials in tension-free inguinal hernia repair: prolene versus Vypro versus surgisis. Int Surg 90(3 Suppl):S21–S23
6.
go back to reference O’Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK (2005) Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92:166–170PubMedCrossRef O’Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK (2005) Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92:166–170PubMedCrossRef
7.
go back to reference Horstmann R, Hellwig M, Classen C, Rottgermann S, Palmes D (2006) Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. World J Surg 30:1742–1749PubMedCrossRef Horstmann R, Hellwig M, Classen C, Rottgermann S, Palmes D (2006) Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. World J Surg 30:1742–1749PubMedCrossRef
8.
go back to reference Heikkinen T, Wollert S, Osterberg J, Smedberg S, Bringman S (2006) Early results of a randomised trial comparing Prolene and VyproII-mesh in endoscopic extraperitoneal inguinal hernia repair (TEP) of recurrent unilateral hernias. Hernia 10:34–40PubMedCrossRef Heikkinen T, Wollert S, Osterberg J, Smedberg S, Bringman S (2006) Early results of a randomised trial comparing Prolene and VyproII-mesh in endoscopic extraperitoneal inguinal hernia repair (TEP) of recurrent unilateral hernias. Hernia 10:34–40PubMedCrossRef
9.
go back to reference Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef Cobb WS, Kercher KW, Heniford BT (2005) The argument for lightweight polypropylene mesh in hernia repair. Surg Innov 12:63–69PubMedCrossRef
10.
11.
go back to reference Conze J, Kingsnorth AN, Flament JB, Simmermacher R, Arlt G, Langer C, Schippers E, Hartley M, Schumpelick V (2005) Randomized clinical trial comparing lightweight composite mesh with polyester or polypropylene mesh for incisional hernia repair. Br J Surg 92:1488–1493PubMedCrossRef Conze J, Kingsnorth AN, Flament JB, Simmermacher R, Arlt G, Langer C, Schippers E, Hartley M, Schumpelick V (2005) Randomized clinical trial comparing lightweight composite mesh with polyester or polypropylene mesh for incisional hernia repair. Br J Surg 92:1488–1493PubMedCrossRef
12.
go back to reference Kumar S, Wilson RG, Nixon SJ, Macintyre IM (2002) Chronic pain after laparoscopic and open mesh repair of groin hernia. Br J Surg 89:1476–1479PubMedCrossRef Kumar S, Wilson RG, Nixon SJ, Macintyre IM (2002) Chronic pain after laparoscopic and open mesh repair of groin hernia. Br J Surg 89:1476–1479PubMedCrossRef
13.
go back to reference Nixon SJ, Kumar S (2005) The totally extraperitoneal approach (TEP) to inguinal hernia repair. Surgeon 3:281–287, 305 Nixon SJ, Kumar S (2005) The totally extraperitoneal approach (TEP) to inguinal hernia repair. Surgeon 3:281–287, 305
15.
go back to reference Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons R, Dunlop D, Gibbs J, Reda D, Henderson W (2004) Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med 350:1819–1827PubMedCrossRef Neumayer L, Giobbie-Hurder A, Jonasson O, Fitzgibbons R, Dunlop D, Gibbs J, Reda D, Henderson W (2004) Open mesh versus laparoscopic mesh repair of inguinal hernia. N Engl J Med 350:1819–1827PubMedCrossRef
16.
go back to reference Tamme C, Scheidbach H, Hampe C, Schneider C, Kockerling F (2003) Totally extraperitoneal endoscopic inguinal hernia repair (TEP). Surg Endosc 17:190–195PubMedCrossRef Tamme C, Scheidbach H, Hampe C, Schneider C, Kockerling F (2003) Totally extraperitoneal endoscopic inguinal hernia repair (TEP). Surg Endosc 17:190–195PubMedCrossRef
17.
go back to reference Kapiris SA, Brough WA, Royston CM, O’Boyle C, Sedman PC (2001) Laparoscopic transabdominal preperitoneal (TAPP) hernia repair. A 7-year two-center experience in 3017 patients. Surg Endosc 15:972–975PubMedCrossRef Kapiris SA, Brough WA, Royston CM, O’Boyle C, Sedman PC (2001) Laparoscopic transabdominal preperitoneal (TAPP) hernia repair. A 7-year two-center experience in 3017 patients. Surg Endosc 15:972–975PubMedCrossRef
18.
go back to reference Schumplick V, Klinge U (2003) Prosthetic implants for hernia repair. Br J Surg 90:1457–1458CrossRef Schumplick V, Klinge U (2003) Prosthetic implants for hernia repair. Br J Surg 90:1457–1458CrossRef
19.
go back to reference Lamb AD, Robson AJ, Nixon SJ (2006) Recurrence after totally extraperitoneal laparoscopic repair: implications for operative technique and surgical training. Surgeon 4:299–307PubMedCrossRef Lamb AD, Robson AJ, Nixon SJ (2006) Recurrence after totally extraperitoneal laparoscopic repair: implications for operative technique and surgical training. Surgeon 4:299–307PubMedCrossRef
Metadata
Title
Comparison of recurrence with lightweight composite polypropylene mesh and heavyweight mesh in laparoscopic totally extraperitoneal inguinal hernia repair: an audit of 1,232 repairs
Authors
D. Akolekar
S. Kumar
L. R. Khan
A. C. de Beaux
S. J. Nixon
Publication date
01-02-2008
Publisher
Springer-Verlag
Published in
Hernia / Issue 1/2008
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-007-0275-7

Other articles of this Issue 1/2008

Hernia 1/2008 Go to the issue

Reply

Reply