Abstract

Purpose

Accurate assessment of ventricular function is required to optimize therapeutic management of cardiac diseases. The aim of this study was to correlate planar equilibrium multigated acquisition (MUGA) with tomographic ventriculography (SPECT) in patients with diverse volumes and wall motion abnormalities.

Methods

Eighty-three studies in 80 patients (56±14 years; 56% women) were classified according to ventricular dilation, wall motion abnormalities and systolic dysfunction. Left and right ventricular ejection fraction (LVEF and RVEF) and end-diastolic and end-systolic left ventricular volumes (EDV and ESV) were obtained using a commercial QBS program for SPECT. On planar acquisition, LVEF and RVEF were obtained using standard techniques and volumes were determined using the count-based method, without blood sampling.

Results

A. Total group: With the planar method, LVEF was 44±17%, RVEF 42±13%, left EDV 147±97 ml (range 31–487 ml) and left ESV 93±85 ml (range 15–423 ml); with SPECT the corresponding values were 40±20%, 49±16%,131±95 ml and 91±89 ml, respectively (p=NS for all but RVEF). Linear correlation was 0.845 for LVEF, 0.688 for RVEF, 0.927 for left EDV and 0.94 for left ESV, with good intra-class correlation. B. Subgroups: Global and intra-class correlations between planar imaging and SPECT were high for volumes, RVEF and LVEF in all subgroups, except in patients with normal wall motion and function, who showed smaller volumes with SPECT. The group with diffuse wall motion abnormalities had a lower EDV on SPECT. In the abnormal left ventricle, RVEF was higher with SPECT.

Conclusion

Good correlation and agreement exist between SPECT and planar MUGA with respect to LVEF and left ventricular volumes. SPECT is useful in patients with functional abnormalities, but less reliable in those with normal small cavities. A combined technique is still necessary, and RVEF should be interpreted cautiously.
Literature
1.
go back to reference Borer J. Measurement of ventricular function and volume. In: Zaret B, Beller G, editors. Nuclear cardiology. State of the art and future directions, 2nd edn. St Louis: Mosby. 1998; p. 201–15. Borer J. Measurement of ventricular function and volume. In: Zaret B, Beller G, editors. Nuclear cardiology. State of the art and future directions, 2nd edn. St Louis: Mosby. 1998; p. 201–15.
2.
go back to reference Lu P, Liu X, Shi R, Mo L, Borer JS. Comparison of tomographic and planar radionuclide ventriculography in the assessment of regional left ventricular function in patients with left ventricular aneurysm before and after surgery. J Nucl Cardiol 1994;1:537–45.PubMedCrossRef Lu P, Liu X, Shi R, Mo L, Borer JS. Comparison of tomographic and planar radionuclide ventriculography in the assessment of regional left ventricular function in patients with left ventricular aneurysm before and after surgery. J Nucl Cardiol 1994;1:537–45.PubMedCrossRef
3.
go back to reference Dodge HT, Sandler H, Ballew DW, Lord JD Jr. The use of biplane angiocardiography for the measurement of left ventricular volume in man. Am Heart J 1960;60:762–76.PubMedCrossRef Dodge HT, Sandler H, Ballew DW, Lord JD Jr. The use of biplane angiocardiography for the measurement of left ventricular volume in man. Am Heart J 1960;60:762–76.PubMedCrossRef
4.
go back to reference Links JM, Becker LC, Shindledecker JG, Guzman P, Burow RD, Nickoloff EL, et al. Measurement of absolute left ventricular volume from gated blood pool studies. Circulation 1982;65:82–91.PubMed Links JM, Becker LC, Shindledecker JG, Guzman P, Burow RD, Nickoloff EL, et al. Measurement of absolute left ventricular volume from gated blood pool studies. Circulation 1982;65:82–91.PubMed
5.
go back to reference Starling MR, Dell'Italia LJ, Walsh RA, Little WC, Benedetto AR, Nusynowitz ML. Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction. J Am Coll Cardiol 1984;3:789–98.PubMedCrossRef Starling MR, Dell'Italia LJ, Walsh RA, Little WC, Benedetto AR, Nusynowitz ML. Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction. J Am Coll Cardiol 1984;3:789–98.PubMedCrossRef
6.
go back to reference Massardo T, Gal RA, Grenier RP, Schmidt DH, Port SC. Left ventricular volume calculation using a count-ratio method applied to multigated radionuclide angiography. J Nucl Med 1990;31:450–6. Erratum in: J Nucl Med 1990;31:1449.PubMed Massardo T, Gal RA, Grenier RP, Schmidt DH, Port SC. Left ventricular volume calculation using a count-ratio method applied to multigated radionuclide angiography. J Nucl Med 1990;31:450–6. Erratum in: J Nucl Med 1990;31:1449.PubMed
7.
go back to reference Levy WC, Cerqueira MD, Matsuoka DT, Harp GD, Sheehan FH, Stratton JR. Four radionuclide methods for left ventricular volume determination: comparison of a manual and an automated technique. J Nucl Med 1992;33:763–70.PubMed Levy WC, Cerqueira MD, Matsuoka DT, Harp GD, Sheehan FH, Stratton JR. Four radionuclide methods for left ventricular volume determination: comparison of a manual and an automated technique. J Nucl Med 1992;33:763–70.PubMed
8.
go back to reference Manrique A, Faraggi M, Vera P, Vilain D, Lebtahi R, Cribier A, et al. 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 1999;40:805–9.PubMed Manrique A, Faraggi M, Vera P, Vilain D, Lebtahi R, Cribier A, et al. 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med 1999;40:805–9.PubMed
9.
go back to reference Chua T, Yin LC, Thiang TH, Choo TB, Ping DZ, Leng LY. Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: correlation with equilibrium radionuclide ventriculography and echocardiography. J Nucl Cardiol 2000;7:301–11.PubMedCrossRef Chua T, Yin LC, Thiang TH, Choo TB, Ping DZ, Leng LY. Accuracy of the automated assessment of left ventricular function with gated perfusion SPECT in the presence of perfusion defects and left ventricular dysfunction: correlation with equilibrium radionuclide ventriculography and echocardiography. J Nucl Cardiol 2000;7:301–11.PubMedCrossRef
10.
go back to reference Klocke F, Baird M, Bateman T, Berman D, Caribello B, Cerqueira M, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging. http://www.asnc.org 2003. Klocke F, Baird M, Bateman T, Berman D, Caribello B, Cerqueira M, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging. http://​www.​asnc.​org 2003.
11.
go back to reference Lavados H, Massardo T, Gutiérrez D, Jaimovich R, Alay R. Biventricular ejection fraction reproducibility with planar manual and automatic SPECT method in equilibrium ventriculography with Tc99m-red labelled cells [abstract]. ALASBIMN J 2007;9(35). Lavados H, Massardo T, Gutiérrez D, Jaimovich R, Alay R. Biventricular ejection fraction reproducibility with planar manual and automatic SPECT method in equilibrium ventriculography with Tc99m-red labelled cells [abstract]. ALASBIMN J 2007;9(35).
12.
go back to reference Nichols K, Saouaf R, Ababneh AA, Barst RJ, Rosenbaum MS, Groch MW, et al. Validation of SPECT equilibrium radionuclide angiographic right ventricular parameters by cardiac magnetic resonance imaging. J Nucl Cardiol 2002;9:226–8.CrossRef Nichols K, Saouaf R, Ababneh AA, Barst RJ, Rosenbaum MS, Groch MW, et al. Validation of SPECT equilibrium radionuclide angiographic right ventricular parameters by cardiac magnetic resonance imaging. J Nucl Cardiol 2002;9:226–8.CrossRef
13.
go back to reference Akinboboye O, Nichols K, Wang Y, Uzodinma RD, Reichek N. Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles. J Nucl Cardiol 2005;12:418–27.PubMedCrossRef Akinboboye O, Nichols K, Wang Y, Uzodinma RD, Reichek N. Accuracy of radionuclide ventriculography assessed by magnetic resonance imaging in patients with abnormal left ventricles. J Nucl Cardiol 2005;12:418–27.PubMedCrossRef
14.
go back to reference Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, et al. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 2001;8:645–51.PubMedCrossRef Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, et al. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. J Nucl Cardiol 2001;8:645–51.PubMedCrossRef
15.
go back to reference Daou D, Harel F, Helal BO, Fourme T, Colin P, Lebtahi R, et al. Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation. J Nucl Med 2001;42:1043–9.PubMed Daou D, Harel F, Helal BO, Fourme T, Colin P, Lebtahi R, et al. Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation. J Nucl Med 2001;42:1043–9.PubMed
16.
go back to reference Chin BB, Bloomgarden DC, Xia W, Kim HJ, Fayad ZA, Ferrari VA, et al. Right and left ventricular volume and ejection fraction by tomographic gated blood-pool scintigraphy. J Nucl Med 1997;38:942–8.PubMed Chin BB, Bloomgarden DC, Xia W, Kim HJ, Fayad ZA, Ferrari VA, et al. Right and left ventricular volume and ejection fraction by tomographic gated blood-pool scintigraphy. J Nucl Med 1997;38:942–8.PubMed
17.
go back to reference Nichols K, Humayun N, De Bondt P, Vandenberghe S, Akinboboye OO, Bergmann SR. Model dependence of gated blood pool SPECT ventricular function measurements. J Nucl Cardiol 2004;11:282–92.PubMedCrossRef Nichols K, Humayun N, De Bondt P, Vandenberghe S, Akinboboye OO, Bergmann SR. Model dependence of gated blood pool SPECT ventricular function measurements. J Nucl Cardiol 2004;11:282–92.PubMedCrossRef
18.
go back to reference Vaquette B, Fleury E, Camenzind E, Doriot PA, Righetti A. Comparative study of left ventricular ejection fraction and volume by 2 isotopic methods and contrast angiography. Arch Mal Coeur Vaiss 2003;96:85–91.PubMed Vaquette B, Fleury E, Camenzind E, Doriot PA, Righetti A. Comparative study of left ventricular ejection fraction and volume by 2 isotopic methods and contrast angiography. Arch Mal Coeur Vaiss 2003;96:85–91.PubMed
19.
go back to reference Van Kriekinge SD, Berman DS, Germano G. Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT. J Nucl Cardiol 1999;6:498–506.PubMedCrossRef Van Kriekinge SD, Berman DS, Germano G. Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT. J Nucl Cardiol 1999;6:498–506.PubMedCrossRef
20.
go back to reference Nakajo H, Kumita S, Cho K, Mizumura S, Toba M, Fukushima M, et al. Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography. Kaku Igaku 2002;39:469–76.PubMed Nakajo H, Kumita S, Cho K, Mizumura S, Toba M, Fukushima M, et al. Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography. Kaku Igaku 2002;39:469–76.PubMed
21.
go back to reference Daou D, Vilain D, Colin P, Lebtahi R, Fourme T, Coaguila C, et al. Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function. Eur J Nucl Med Mol Imaging 2003;30:859–67.PubMedCrossRef Daou D, Vilain D, Colin P, Lebtahi R, Fourme T, Coaguila C, et al. Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function. Eur J Nucl Med Mol Imaging 2003;30:859–67.PubMedCrossRef
22.
go back to reference Castell-Conesa J, Aguade-Bruix S, Garcia-Burillo A, Gonzalez JM, Canela T, Oller G, et al. Reproducibility of measurements of left ventricular function with gated myocardial perfusion SPECT and comparison with blood pool radionuclide ventriculography. Rev Esp Cardiol 2004;57:931–8.PubMedCrossRef Castell-Conesa J, Aguade-Bruix S, Garcia-Burillo A, Gonzalez JM, Canela T, Oller G, et al. Reproducibility of measurements of left ventricular function with gated myocardial perfusion SPECT and comparison with blood pool radionuclide ventriculography. Rev Esp Cardiol 2004;57:931–8.PubMedCrossRef
23.
go back to reference Vanhove C, Walgraeve N, De Geeter F, Franken PR. Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 2002;29:735–41.PubMedCrossRef Vanhove C, Walgraeve N, De Geeter F, Franken PR. Gated myocardial perfusion tomography versus gated blood pool tomography for the calculation of left ventricular volumes and ejection fraction. Eur J Nucl Med Mol Imaging 2002;29:735–41.PubMedCrossRef
24.
go back to reference Corbett JR, Jansen DE, Lewis SE, Gabliani GI, Nicod P, Filipchuk NG, et al. Tomographic gated blood pool radionuclide ventriculography: analysis of wall motion and left ventricular volumes in patients with coronary artery disease. J Am Coll Cardiol 1985;6:349–58.PubMedCrossRef Corbett JR, Jansen DE, Lewis SE, Gabliani GI, Nicod P, Filipchuk NG, et al. Tomographic gated blood pool radionuclide ventriculography: analysis of wall motion and left ventricular volumes in patients with coronary artery disease. J Am Coll Cardiol 1985;6:349–58.PubMedCrossRef
25.
go back to reference Iskandrian A, Helfeld H, Lemlek J, Lee J, Iskandrian B, Heo J. Differentiation between primary dilated cardiomyopathy and ischemic cardiomyopathy based on right ventricular performance. Am Heart J 1992;123:768–73.PubMedCrossRef Iskandrian A, Helfeld H, Lemlek J, Lee J, Iskandrian B, Heo J. Differentiation between primary dilated cardiomyopathy and ischemic cardiomyopathy based on right ventricular performance. Am Heart J 1992;123:768–73.PubMedCrossRef
26.
go back to reference Daou D, Van Kriekinge SD, Coaguila C, Lebtahi R, Fourme T, Sitbon O, et al. Automatic quantification of right ventricular function with gated blood pool SPECT. J Nucl Cardiol 2004;11:293–304.PubMedCrossRef Daou D, Van Kriekinge SD, Coaguila C, Lebtahi R, Fourme T, Sitbon O, et al. Automatic quantification of right ventricular function with gated blood pool SPECT. J Nucl Cardiol 2004;11:293–304.PubMedCrossRef
27.
go back to reference Groch MW, DePuey EG, Belzberg AC, Erwin WD, Kamran M, Barnett CA. Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study. J Nucl Med 2001;42:1773–9.PubMed Groch MW, DePuey EG, Belzberg AC, Erwin WD, Kamran M, Barnett CA. Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study. J Nucl Med 2001;42:1773–9.PubMed
28.
go back to reference Wright GA, Thackray S, Howey S, Cleland JG. Left ventricular ejection fraction and volumes from gated blood-pool SPECT: comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure. J Nucl Med 2003;44:494–8.PubMed Wright GA, Thackray S, Howey S, Cleland JG. Left ventricular ejection fraction and volumes from gated blood-pool SPECT: comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure. J Nucl Med 2003;44:494–8.PubMed
29.
go back to reference Hacker M, Hoyer X, Kupzyk S, La Fougere C, Kois J, Stempfle HU, et al. Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography. Int J Cardiovasc Imaging 2006;22:407–16.PubMedCrossRef Hacker M, Hoyer X, Kupzyk S, La Fougere C, Kois J, Stempfle HU, et al. Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography. Int J Cardiovasc Imaging 2006;22:407–16.PubMedCrossRef
30.
go back to reference De Bondt P, Claessens T, Rys B, De Winter O, Vandenberghe S, Segers P, et al. Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom. J Nucl Med 2005;46:165–71.PubMed De Bondt P, Claessens T, Rys B, De Winter O, Vandenberghe S, Segers P, et al. Accuracy of 4 different algorithms for the analysis of tomographic radionuclide ventriculography using a physical, dynamic 4-chamber cardiac phantom. J Nucl Med 2005;46:165–71.PubMed
31.
go back to reference De Bondt P, De Winter O, De Sutter J, Dierckx RA. Agreement between four available algorithms to evaluate global systolic left and right ventricular function from tomographic radionuclide ventriculography and comparison with planar imaging. Nucl Med Commun 2005;26:351–9.PubMedCrossRef De Bondt P, De Winter O, De Sutter J, Dierckx RA. Agreement between four available algorithms to evaluate global systolic left and right ventricular function from tomographic radionuclide ventriculography and comparison with planar imaging. Nucl Med Commun 2005;26:351–9.PubMedCrossRef
32.
go back to reference Bartlett ML, Srinivasan G, Barker WC, Kitsiou AN, Dilsizian V, Bacharach SL. Left ventricular ejection fraction: comparison of results from planar and SPECT gated blood-pool studies. J Nucl Med 1996;37:1795–9.PubMed Bartlett ML, Srinivasan G, Barker WC, Kitsiou AN, Dilsizian V, Bacharach SL. Left ventricular ejection fraction: comparison of results from planar and SPECT gated blood-pool studies. J Nucl Med 1996;37:1795–9.PubMed
33.
go back to reference Adachi I, Umeda T, Shimomura H, Suwa M, Komori T, Ogura Y, et al. Comparative study of quantitative blood pool SPECT imaging with 180 degrees and 360 degrees acquisition orbits on accuracy of cardiac function. J Nucl Cardiol 2005;12:186–94.PubMedCrossRef Adachi I, Umeda T, Shimomura H, Suwa M, Komori T, Ogura Y, et al. Comparative study of quantitative blood pool SPECT imaging with 180 degrees and 360 degrees acquisition orbits on accuracy of cardiac function. J Nucl Cardiol 2005;12:186–94.PubMedCrossRef
34.
go back to reference Kim SJ, Kim IJ, Kim YS, Kim YK, Shin YB, Kim DS. Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography. J Nucl Cardiol 2005;12:553–9.PubMedCrossRef Kim SJ, Kim IJ, Kim YS, Kim YK, Shin YB, Kim DS. Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography. J Nucl Cardiol 2005;12:553–9.PubMedCrossRef
35.
go back to reference Slart RH, Poot L, Piers DA, Van Veldhuisen DJ, Nichols K, Jager PL. Gated blood-pool SPECT automated versus manual left ventricular function calculations. Nucl Med Commun 2004;25:75–80.PubMedCrossRef Slart RH, Poot L, Piers DA, Van Veldhuisen DJ, Nichols K, Jager PL. Gated blood-pool SPECT automated versus manual left ventricular function calculations. Nucl Med Commun 2004;25:75–80.PubMedCrossRef
Metadata
Title
Comparison of radionuclide ventriculography using SPECT and planar techniques in different cardiac conditions
Authors
Teresa Massardo
Rodrigo Jaimovich
Hugo Lavados
Daniela Gutiérrez
J. Carlos Rodríguez
J. Miguel Saavedra
Rita Alay
Héctor Gatica
Publication date
01-11-2007
Publisher
Springer-Verlag
Published in
European Journal of Nuclear Medicine and Molecular Imaging / Issue 11/2007
Print ISSN: 1619-7070
Electronic ISSN: 1619-7089
DOI
https://doi.org/10.1007/s00259-007-0472-8

Other articles of this Issue 11/2007

European Journal of Nuclear Medicine and Molecular Imaging 11/2007 Go to the issue