Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 6/2014

01-06-2014 | Otology

Comparison of KTP, Thulium, and CO2 laser in stapedotomy using specialized visualization techniques: thermal effects

Authors: Digna M. A. Kamalski, Rudolf M. Verdaasdonk, Tjeerd de Boorder, Robert Vincent, Franco Trabelzini, Wilko Grolman

Published in: European Archives of Oto-Rhino-Laryngology | Issue 6/2014

Login to get access

Abstract

High-speed thermal imaging enables visualization of heating of the vestibule during laser-assisted stapedotomy, comparing KTP, CO2, and Thulium laser light. Perforation of the stapes footplate with laser bears the risk of heating of the inner ear fluids. The amount of heating depends on absorption of the laser light and subsequent tissue ablation. The ablation of the footplate is driven by strong water absorption for the CO2 and Thulium laser. For the KTP laser wavelength, ablation is driven by carbonization of the footplate and it might penetrate deep into the inner ear without absorption in water. The thermal effects were visualized in an inner ear model, using two new techniques: (1) high-speed Schlieren imaging shows relative dynamic changes of temperatures up to 2 ms resolution in the perilymph. (2) Thermo imaging provides absolute temperature measurements around the footplate up to 40 ms resolution. The high-speed Schlieren imaging showed minimal heating using the KTP laser. Both CO2 and Thulium laser showed heating below the footplate. Thulium laser wavelength generated heating up to 0.6 mm depth. This was confirmed with thermal imaging, showing a rise of temperature of 4.7 (±3.5) °C for KTP and 9.4 (±6.9) for Thulium in the area of 2 mm below the footplate. For stapedotomy, the Thulium and CO2 laser show more extended thermal effects compared to KTP. High-speed Schlieren imaging and thermal imaging are complimentary techniques to study lasers thermal effects in tissue.
Appendix
Available only for authorised users
Literature
1.
go back to reference Hausler R (2007) General history of stapedectomy. Adv Otorhinolaryngol 65:1–5PubMed Hausler R (2007) General history of stapedectomy. Adv Otorhinolaryngol 65:1–5PubMed
3.
go back to reference Hausler R, Schar PJ, Pratisto H, Weber HP, Frenz M (1999) Advantages and dangers of erbium laser application in stapedotomy. Acta Otolaryngol 119:207–213PubMedCrossRef Hausler R, Schar PJ, Pratisto H, Weber HP, Frenz M (1999) Advantages and dangers of erbium laser application in stapedotomy. Acta Otolaryngol 119:207–213PubMedCrossRef
4.
go back to reference Gardner G, Robertson JH, Tomoda K, Clark WC (1984) CO2 laser stapedotomy: is it practical? Am J Otolaryngol 5:108–117PubMedCrossRef Gardner G, Robertson JH, Tomoda K, Clark WC (1984) CO2 laser stapedotomy: is it practical? Am J Otolaryngol 5:108–117PubMedCrossRef
5.
go back to reference Wong BJ, Neev J, van Gemert MJ (1997) Surface temperature distributions in carbon dioxide, argon, and KTP (Nd:YAG) laser ablated otic capsule and calvarial bone. Am J Otol 18:766–772PubMedCrossRef Wong BJ, Neev J, van Gemert MJ (1997) Surface temperature distributions in carbon dioxide, argon, and KTP (Nd:YAG) laser ablated otic capsule and calvarial bone. Am J Otol 18:766–772PubMedCrossRef
6.
go back to reference Verdaasdonk RM, van Swol CF, Grimbergen MC, Rem AI (2006) Imaging techniques for research and education of thermal and mechanical interactions of lasers with biological and model tissues. J Biomed Opt 11:041110PubMedCrossRef Verdaasdonk RM, van Swol CF, Grimbergen MC, Rem AI (2006) Imaging techniques for research and education of thermal and mechanical interactions of lasers with biological and model tissues. J Biomed Opt 11:041110PubMedCrossRef
7.
go back to reference Noyes WS, McCaffrey TV, Fabry DA, Robinette MS, Suman VJ (1996) Effect of temperature elevation on rabbit cochlear function as measured by distortion-product otoacoustic emissions. Otolaryngol Head Neck Surg 115:548–552PubMedCrossRef Noyes WS, McCaffrey TV, Fabry DA, Robinette MS, Suman VJ (1996) Effect of temperature elevation on rabbit cochlear function as measured by distortion-product otoacoustic emissions. Otolaryngol Head Neck Surg 115:548–552PubMedCrossRef
8.
go back to reference Barnett SB (1980) The influence of ultrasound and temperature on the cochlear microphonic response following a round window irradiation. Acta Otolaryngol 90:32–39PubMedCrossRef Barnett SB (1980) The influence of ultrasound and temperature on the cochlear microphonic response following a round window irradiation. Acta Otolaryngol 90:32–39PubMedCrossRef
9.
go back to reference Lesinski SG, Palmer A (1989) Lasers for otosclerosis: CO2 vs. Argon and KTP-532. Laryngoscope 99:1–8PubMed Lesinski SG, Palmer A (1989) Lasers for otosclerosis: CO2 vs. Argon and KTP-532. Laryngoscope 99:1–8PubMed
10.
go back to reference Gherini S, Horn KL, Causse JB, McArthur GR (1993) Fiberoptic argon laser stapedotomy: is it safe? Am J Otol 14:283–289PubMed Gherini S, Horn KL, Causse JB, McArthur GR (1993) Fiberoptic argon laser stapedotomy: is it safe? Am J Otol 14:283–289PubMed
11.
go back to reference Kodali S, Harvey SA, Prieto TE (1997) Thermal effects of laser stapedectomy in an animal model: CO2 versus KTP. Laryngoscope 107:1445–1450PubMedCrossRef Kodali S, Harvey SA, Prieto TE (1997) Thermal effects of laser stapedectomy in an animal model: CO2 versus KTP. Laryngoscope 107:1445–1450PubMedCrossRef
Metadata
Title
Comparison of KTP, Thulium, and CO2 laser in stapedotomy using specialized visualization techniques: thermal effects
Authors
Digna M. A. Kamalski
Rudolf M. Verdaasdonk
Tjeerd de Boorder
Robert Vincent
Franco Trabelzini
Wilko Grolman
Publication date
01-06-2014
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 6/2014
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-013-2624-8

Other articles of this Issue 6/2014

European Archives of Oto-Rhino-Laryngology 6/2014 Go to the issue