Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT

Authors: Stefan Wirth, Thomas Meindl, Marcus Treitl, Klaus-Jürgen Pfeifer, Maximilian Reiser

Published in: European Radiology | Issue 8/2006

Login to get access

Abstract

The purpose of this study was to analyze different patient positioning strategies for minimizing artifacts of the shoulder girdle in head and neck CT. Standardized CT examinations of three positioning groups were compared (P: patients pushed their shoulders downwards; D: similar optimization by a pulling device; N: no particular positioning optimization). Parameters analyzed were the length of the cervical spine not being superimposed by the shoulder girdle as well as noise in the supraclavicular space. In groups P and D, the portion of the cervical spine not superimposed was significantly larger than in group N (P: 10.4 cm; D: 10.6 cm; N: 8.5 cm). At the supraclavicular space, noise decreased significantly (P: 12.5 HU; D: 12.1 HU; N: 17.7 HU). No significant differences between the two position-optimized groups (P and D) were detected. Optimized shoulder positioning by the patient increases image quality in CT head and neck imaging. The use of a pulling device offers no additional advantages.
Literature
1.
go back to reference La Riviere PJ, Pan X (2002) Longitudinal aliasing in multislice helical computed tomography: sampling and cone-beam effects. IEEE Trans Med Imag 21:1366-1373CrossRef La Riviere PJ, Pan X (2002) Longitudinal aliasing in multislice helical computed tomography: sampling and cone-beam effects. IEEE Trans Med Imag 21:1366-1373CrossRef
2.
go back to reference Wilting JE, Timmer J (1999) Artefacts in spiral-CT images and their relation to pitch and subject morphology. Eur Radiol 9:316-322. DOI 10.1007/s003300050673PubMedCrossRef Wilting JE, Timmer J (1999) Artefacts in spiral-CT images and their relation to pitch and subject morphology. Eur Radiol 9:316-322. DOI 10.1007/s003300050673PubMedCrossRef
3.
go back to reference Baum U, Anders K, Steinbichler G, Lell M, Greess H, Riedel T, Kachelriess M, Kalender WA, Bautz WA (2004) Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique. Eur Radiol 14:1873-1881. DOI:10.1007/s00330-004-2403-4PubMedCrossRef Baum U, Anders K, Steinbichler G, Lell M, Greess H, Riedel T, Kachelriess M, Kalender WA, Bautz WA (2004) Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique. Eur Radiol 14:1873-1881. DOI:10.1007/s00330-004-2403-4PubMedCrossRef
4.
go back to reference Kraas JR, Underhill TE, D’Agostino RB Jr, Williams DW 3rd, Cox JA, Greven KM (2001) Quantitative analysis from CT is prognostic for local control of supraglottic carcinoma. Head Neck 23:1031-1036. DOI 10.1002/hed.10030PubMedCrossRef Kraas JR, Underhill TE, D’Agostino RB Jr, Williams DW 3rd, Cox JA, Greven KM (2001) Quantitative analysis from CT is prognostic for local control of supraglottic carcinoma. Head Neck 23:1031-1036. DOI 10.1002/hed.10030PubMedCrossRef
5.
go back to reference Pameijer FA, Mancuso AA, Mendenhall WM, Parsons JT, Mukherji SK, Hermans R, Kubilis PS (1998) Evaluation of pretreatment computed tomography as a predictor of local control in T1/T2 pyriform sinus carcinoma treated with definitive radiotherapy. Head Neck 20:159-168PubMedCrossRef Pameijer FA, Mancuso AA, Mendenhall WM, Parsons JT, Mukherji SK, Hermans R, Kubilis PS (1998) Evaluation of pretreatment computed tomography as a predictor of local control in T1/T2 pyriform sinus carcinoma treated with definitive radiotherapy. Head Neck 20:159-168PubMedCrossRef
6.
go back to reference Keberle M, Tschammler A, Hahn D (2002) Single-bolus technique for spiral CT of laryngopharyngeal squamous cell carcinoma: comparison of different contrast material volumes, flow rates, and start delays. Radiology 224(1):171-176PubMedCrossRef Keberle M, Tschammler A, Hahn D (2002) Single-bolus technique for spiral CT of laryngopharyngeal squamous cell carcinoma: comparison of different contrast material volumes, flow rates, and start delays. Radiology 224(1):171-176PubMedCrossRef
7.
go back to reference Baum U, Greess H, Lell M, Nomayr A, Lenz M (2000) Imaging of head and neck tumors - methods: CT, spiral-CT, multislice-spiral CT. Eur J Radiol 33:153-160PubMedCrossRef Baum U, Greess H, Lell M, Nomayr A, Lenz M (2000) Imaging of head and neck tumors - methods: CT, spiral-CT, multislice-spiral CT. Eur J Radiol 33:153-160PubMedCrossRef
8.
go back to reference Groell R, Willfurth P, Schaffler GJ, Mayer R, Schmidt F, Uggowitzer MM, Tillich M, Genser B (1999) Signal-enhanced spiral CT of the head and neck: comparison of contrast material injection rates. AJNR 20:1732-1736PubMed Groell R, Willfurth P, Schaffler GJ, Mayer R, Schmidt F, Uggowitzer MM, Tillich M, Genser B (1999) Signal-enhanced spiral CT of the head and neck: comparison of contrast material injection rates. AJNR 20:1732-1736PubMed
9.
go back to reference Schorn C, Obenauer S, Funke M, Hermann KP, Kopka L, Grabbe E (1999) Slice sensitivity profile and image pixel noise of multi-slice spiral CT in comparison with single slice spiral CT (in German). Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 171:219-225PubMedCrossRef Schorn C, Obenauer S, Funke M, Hermann KP, Kopka L, Grabbe E (1999) Slice sensitivity profile and image pixel noise of multi-slice spiral CT in comparison with single slice spiral CT (in German). Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 171:219-225PubMedCrossRef
10.
go back to reference McCollough CH, Zink FE (1999) Performance evaluation of a multi-slice CT system. Med Phys 26:2223-2230PubMedCrossRef McCollough CH, Zink FE (1999) Performance evaluation of a multi-slice CT system. Med Phys 26:2223-2230PubMedCrossRef
11.
go back to reference Fuchs T, Krause J, Schaller S, Flohr T, Kalender WA (2000) Spiral interpolation algorithms for multislice spiral CT-part II: measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system. IEEE Trans Med Imag 19:835-847CrossRef Fuchs T, Krause J, Schaller S, Flohr T, Kalender WA (2000) Spiral interpolation algorithms for multislice spiral CT-part II: measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system. IEEE Trans Med Imag 19:835-847CrossRef
12.
go back to reference Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA, Saini S (2004) Strategies for CT radiation dose optimization. Radiology 230:619-628PubMedCrossRef Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JA, Saini S (2004) Strategies for CT radiation dose optimization. Radiology 230:619-628PubMedCrossRef
13.
go back to reference Mettler FA, Briggs JA, Carchman R, Altobelli KK, Hart BL, Kelsey CA (1993) Use of radiology in U.S. general short-term hospitals: 1980–1990. Radiology 189:377-380PubMed Mettler FA, Briggs JA, Carchman R, Altobelli KK, Hart BL, Kelsey CA (1993) Use of radiology in U.S. general short-term hospitals: 1980–1990. Radiology 189:377-380PubMed
14.
go back to reference Bunge RE, Herman CL (1987) Usage of diagnostic imaging procedures: a nationwide hospital study. Radiology 163:569-573PubMed Bunge RE, Herman CL (1987) Usage of diagnostic imaging procedures: a nationwide hospital study. Radiology 163:569-573PubMed
15.
go back to reference Mettler FA, Wiest PW, Locken JA, Kelsey CA (2000) CT scanning: patterns of use and dose. J Radiol Prot 20:353-359PubMedCrossRef Mettler FA, Wiest PW, Locken JA, Kelsey CA (2000) CT scanning: patterns of use and dose. J Radiol Prot 20:353-359PubMedCrossRef
16.
go back to reference Rothenberg LN, Pentlow KS (1992) Radiation dose in CT. Radiographics 12:1225-1243PubMed Rothenberg LN, Pentlow KS (1992) Radiation dose in CT. Radiographics 12:1225-1243PubMed
17.
go back to reference Scheck RJ, Coppenrath EM, Kellner MW, Lehmann KJ, Rock C, Rieger J, Rothmeier L, Schweden F, Bauml AA, Hahn K (1998) Radiation dose and image quality in spiral computed tomography: multicentre evaluation at six institutions. Br J Radiol 71:734-744PubMed Scheck RJ, Coppenrath EM, Kellner MW, Lehmann KJ, Rock C, Rieger J, Rothmeier L, Schweden F, Bauml AA, Hahn K (1998) Radiation dose and image quality in spiral computed tomography: multicentre evaluation at six institutions. Br J Radiol 71:734-744PubMed
18.
go back to reference Kane AG, Reilly KC, Murphy TF (2004) Swimmer’s CT: improved imaging of the lower neck and thoracic inlet. AJNR 25:859-862PubMed Kane AG, Reilly KC, Murphy TF (2004) Swimmer’s CT: improved imaging of the lower neck and thoracic inlet. AJNR 25:859-862PubMed
Metadata
Title
Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT
Authors
Stefan Wirth
Thomas Meindl
Marcus Treitl
Klaus-Jürgen Pfeifer
Maximilian Reiser
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
European Radiology / Issue 8/2006
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-006-0168-7

Other articles of this Issue 8/2006

European Radiology 8/2006 Go to the issue