Open Access 01-12-2018 | Research article
Comparison among perfect-C®, zero-P®, and plates with a cage in single-level cervical degenerative disc disease
Published in: BMC Musculoskeletal Disorders | Issue 1/2018
Login to get accessAbstract
Background
We intended to analyze the efficacy of a new integrated cage and plate device called Perfect-C for anterior cervical discectomy and fusion (ACDF) to cure single-level cervical degenerative disc disease.
Methods
We enrolled 148 patients who were subjected to single-level ACDF with one of the following three surgical devices: a Perfect-C implant (41 patients), a Zero-P implant (36 patients), or a titanium plate with a polyetheretherketone (PEEK) cage (71 patients). We conducted a retrospective study to compare the clinical and radiological results among the three groups.
Results
The length of the operation, intraoperative blood loss, and duration of hospitalization were significantly lower in the Perfect-C group than in the Zero-P and plate-with-cage groups (P < 0.05). At the last follow-up visit, heterotopic ossification (HO) was not observed in any cases (0%) in the Perfect-C and Zero-P groups but was noted in 21 cases (30%) in the plate-with-cage group. The cephalad and caudal plate-to-disc distance (PDD) and the cephalad and caudal PDD/anterior body height (ABH) were significantly greater in the Perfect-C and Zero-P groups than in the plate-with-cage group (P < 0.05). Subsidence occurred in five cases (14%) in the Perfect-C group, in nine cases (25%) in the Zero-P group, and in 15 cases (21%) in the plate-with-cage group. Fusion occurred in 37 cases (90%) in the Perfect-C group, in 31 cases (86%) in the Zero-P group, and in 68 cases (95%) in the plate-with-cage group.
Conclusions
The Perfect-C, Zero-P, and plate-with-cage devices are effective for treating single-level cervical degenerative disc disease. However, the Perfect-C implant has many advantages over both the Zero-P implant and conventional plate-cage treatments. The Perfect-C implant was associated with shorter operation times and hospitalization durations, less blood loss, and lower subsidence rates compared with the Zero-P implant or the titanium plate with a PEEK cage.