Skip to main content
Top
Published in: Lasers in Medical Science 7/2018

01-09-2018 | Original Article

Comparative microstructural analysis of bone osteotomies after cutting by computer-assisted robot-guided laser osteotome and piezoelectric osteotome: an in vivo animal study

Authors: Marcello Augello, Waldemar Deibel, Katja Nuss, Philippe Cattin, Philipp Jürgens

Published in: Lasers in Medical Science | Issue 7/2018

Login to get access

Abstract

Most industrial laser applications utilize computer and robot assistance, for guidance, safety, repeatability, and precision. In contrast, medical applications using laser systems are mostly conducted manually. The advantages can be effective only when the system is coupled to a robotic guidance, as operating by hand does not reach the required accuracy. We currently developed the first laser osteotome which offers preoperative planning based on CT data, robot guidance, and a precise execution of the laser cuts. In an animal trial, our system was used to create a grid pattern of the same depth on the inner layer of parietal bone in 12 adult sheep. The same bone cuts were done with piezoelectric osteotome on the contralateral side. The micro-CT and histological analysis showed more new mineralized bone in the laser group compared to the piezoelectric group. As well, a cutting pattern with especially a constant osteotomy depth in the laser group was demonstrated. The here presented autonomous osteotomy tool shows not only an advantage in early bone healing stage but additionally sharp bone cuts with a very high accuracy and freely selectable design cuts.
Literature
1.
go back to reference Burgner J, Muller M, Raczkowsky J, Worn H (2010) Ex vivo accuracy evaluation for robot assisted laser bone ablation. Int J Med Robot 6:489–500CrossRefPubMed Burgner J, Muller M, Raczkowsky J, Worn H (2010) Ex vivo accuracy evaluation for robot assisted laser bone ablation. Int J Med Robot 6:489–500CrossRefPubMed
2.
go back to reference Stübinger S, Ghanaati S, Saldamli B, Kirkpatrick CJ, Sader R (2009) Er:YAG laser osteotomy: preliminary clinical and histological results of a new technique for contact-free bone surgery. Eur Surg Res 42:150–156CrossRefPubMed Stübinger S, Ghanaati S, Saldamli B, Kirkpatrick CJ, Sader R (2009) Er:YAG laser osteotomy: preliminary clinical and histological results of a new technique for contact-free bone surgery. Eur Surg Res 42:150–156CrossRefPubMed
3.
go back to reference Kuttenberger JJ, Stübinger S, Waibel A, Werner M, Klasing M, Ivanenko M, Hering P, Von Rechenberg B, Sader R, Zeilhofer HF. (2080) Computer-guided CO2-laser osteotomy of the sheep tibia: technical prerequisites and first results. Photomed Laser Surg 26:129–136 Kuttenberger JJ, Stübinger S, Waibel A, Werner M, Klasing M, Ivanenko M, Hering P, Von Rechenberg B, Sader R, Zeilhofer HF. (2080) Computer-guided CO2-laser osteotomy of the sheep tibia: technical prerequisites and first results. Photomed Laser Surg 26:129–136
4.
go back to reference Kuttenberger JJ, Waibel A, Stübinger S, Werner M, Klasing M, Ivanenko M, Hering P, von Rechenberg B, Sader R, Zeilhofer HF (2010) Lasers Med Sci 25:239–249CrossRefPubMed Kuttenberger JJ, Waibel A, Stübinger S, Werner M, Klasing M, Ivanenko M, Hering P, von Rechenberg B, Sader R, Zeilhofer HF (2010) Lasers Med Sci 25:239–249CrossRefPubMed
5.
go back to reference Akyol UK, Güngörmüs M, Gündogdu C, Erdem H (2009) Histologic evaluation of the effects of Er:YAG laser on bone ablation. J Contemp Dent Pract 10:65–72 Akyol UK, Güngörmüs M, Gündogdu C, Erdem H (2009) Histologic evaluation of the effects of Er:YAG laser on bone ablation. J Contemp Dent Pract 10:65–72
6.
go back to reference Kesler G, Romanos G, Koren R (2006) Use of Er:YAG laser to improve osseointegration of titanium alloy implants—a comparison of bone healing. Int J Oral Maxillofac Implants 21(3):375–379PubMed Kesler G, Romanos G, Koren R (2006) Use of Er:YAG laser to improve osseointegration of titanium alloy implants—a comparison of bone healing. Int J Oral Maxillofac Implants 21(3):375–379PubMed
7.
go back to reference Stübinger S, Biermeier K, Bächi B, Ferguson SJ, Sader R, von Rechenberg B (2010) Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: a biomechanical and histological analysis in sheep. Lasers Surg Med 42(7):652–661CrossRefPubMed Stübinger S, Biermeier K, Bächi B, Ferguson SJ, Sader R, von Rechenberg B (2010) Comparison of Er:YAG laser, piezoelectric, and drill osteotomy for dental implant site preparation: a biomechanical and histological analysis in sheep. Lasers Surg Med 42(7):652–661CrossRefPubMed
8.
go back to reference Nunamaker D (1989) Experimental models of fracture repair. J Clin Orthop Rel Res 5:355 Nunamaker D (1989) Experimental models of fracture repair. J Clin Orthop Rel Res 5:355
9.
go back to reference Augat P (1998) Local tissue properties in bone healing: influence of size and stability of the osteotomy gap. J Orthopaed Res 16:475–481CrossRef Augat P (1998) Local tissue properties in bone healing: influence of size and stability of the osteotomy gap. J Orthopaed Res 16:475–481CrossRef
10.
go back to reference Sarkar M, Patka P, Kinzl L (2001) First histological observations on the incorporation of a novel calcium phosphate bone substitute material in human cancellous bone. J Biomed Mater Res 13:329–334CrossRef Sarkar M, Patka P, Kinzl L (2001) First histological observations on the incorporation of a novel calcium phosphate bone substitute material in human cancellous bone. J Biomed Mater Res 13:329–334CrossRef
11.
go back to reference Schulz G, Götz C, Müller-Gerbl M, Zanette I, Zdora MC, Khimchenko A, Deyhle H, Thalmann P, Müller B (2016) Multimodal imaging of the human knee down to the cellular level. X-ray Microscopy Conference. J Physics 849:1–4 Schulz G, Götz C, Müller-Gerbl M, Zanette I, Zdora MC, Khimchenko A, Deyhle H, Thalmann P, Müller B (2016) Multimodal imaging of the human knee down to the cellular level. X-ray Microscopy Conference. J Physics 849:1–4
12.
go back to reference Martini L, Fini M, Giavaresi G, Giardino R (2001) Sheep model in orthopedic research: a literature review. Comp Med 51:292–299PubMed Martini L, Fini M, Giavaresi G, Giardino R (2001) Sheep model in orthopedic research: a literature review. Comp Med 51:292–299PubMed
13.
go back to reference Fagundes DJ, Taha MO (2004) Modelo animal de doença: critérios de escolha e espécies de animais de uso corrente. Acta Cir Bras 19:59–65CrossRef Fagundes DJ, Taha MO (2004) Modelo animal de doença: critérios de escolha e espécies de animais de uso corrente. Acta Cir Bras 19:59–65CrossRef
14.
go back to reference Baek KW, Deibel W, Marinov D, Griessen M, Dard M, Bruno A, Zeilhofer HF, Cattin P, Jürgens P (2015) Clinical applicability of robot-guided contact free laser osteotomy in cranio-maxillo-facial surgery: in-vitro simulation and in-vivo surgery in minipig mandibles. Br J Oral Maxillofac Surg 53:976–981CrossRefPubMed Baek KW, Deibel W, Marinov D, Griessen M, Dard M, Bruno A, Zeilhofer HF, Cattin P, Jürgens P (2015) Clinical applicability of robot-guided contact free laser osteotomy in cranio-maxillo-facial surgery: in-vitro simulation and in-vivo surgery in minipig mandibles. Br J Oral Maxillofac Surg 53:976–981CrossRefPubMed
15.
go back to reference Bayly JG, Kartha VB, Stevens WH. (1963) The absorption spectra of liquid phase H2O, HDO, D2o from 0.7μm to 10 μm. Infrared Phys 3:211–223 Bayly JG, Kartha VB, Stevens WH. (1963) The absorption spectra of liquid phase H2O, HDO, D2o from 0.7μm to 10 μm. Infrared Phys 3:211–223
16.
go back to reference Doyle BB, Bendit EG, Blout ER (1975) Infrared spectroscopy of collagen and collagen-like polypeptides. Biopolymers 14:937–957CrossRefPubMed Doyle BB, Bendit EG, Blout ER (1975) Infrared spectroscopy of collagen and collagen-like polypeptides. Biopolymers 14:937–957CrossRefPubMed
17.
18.
go back to reference Trost D, Zacherl A, Smith M. (1992) Surgical laser properties and their tissue interaction. St. Louis: Mosby-Year Book Trost D, Zacherl A, Smith M. (1992) Surgical laser properties and their tissue interaction. St. Louis: Mosby-Year Book
19.
go back to reference Sasaki KM, Aoki A, Ichinose S, Yoshino T, Yamada S, Ishikawa I (2002) Scanning electron microscopy and Fourier transformed infrared spectroscopy analysis of bone removal using Er:YAG and CO2 lasers. J Periodontol 73:643–652CrossRefPubMed Sasaki KM, Aoki A, Ichinose S, Yoshino T, Yamada S, Ishikawa I (2002) Scanning electron microscopy and Fourier transformed infrared spectroscopy analysis of bone removal using Er:YAG and CO2 lasers. J Periodontol 73:643–652CrossRefPubMed
20.
go back to reference de Oliveira GJ, Rodrigues CN, Perussi LR, de Souza Rastelli AN, Marcantonio RA, Berbert FL (2016) Effects on bone tissue after osteotomy with different high-energy lasers: an ex vivo study. Photomed Laser Surg 34:291–296CrossRefPubMed de Oliveira GJ, Rodrigues CN, Perussi LR, de Souza Rastelli AN, Marcantonio RA, Berbert FL (2016) Effects on bone tissue after osteotomy with different high-energy lasers: an ex vivo study. Photomed Laser Surg 34:291–296CrossRefPubMed
21.
go back to reference Gabric D, Blaskovic M, Gjorgijevska E, Mladenov M, Tasic B, Juric IB, Ban T (2016) Evaluation of bone healing after osteotomies prepared with Er:YAG laser in contact and noncontact modes and piezosurgery-an animal study. J Oral Maxillofac Surg 74:18–28CrossRefPubMed Gabric D, Blaskovic M, Gjorgijevska E, Mladenov M, Tasic B, Juric IB, Ban T (2016) Evaluation of bone healing after osteotomies prepared with Er:YAG laser in contact and noncontact modes and piezosurgery-an animal study. J Oral Maxillofac Surg 74:18–28CrossRefPubMed
22.
go back to reference Baek KW, Deibel W, Marinov D, Griessen M, Dard M, Bruno A, Zeilhofer HF, Cattin P, Jürgens P (2015) A comparative investigation of bone surface after cutting with mechanical tools and Er:YAG laser. Lasers Surg Med 47:426–432CrossRefPubMed Baek KW, Deibel W, Marinov D, Griessen M, Dard M, Bruno A, Zeilhofer HF, Cattin P, Jürgens P (2015) A comparative investigation of bone surface after cutting with mechanical tools and Er:YAG laser. Lasers Surg Med 47:426–432CrossRefPubMed
23.
go back to reference Kahrs LA, Burgner J, Klenzner T, Raczkowsky J, Schipper J, Wörn H (2010) Planning and simulation of microsurgical laser bone ablation. Int J Comput Assist Radiol Surg 5:155–162CrossRefPubMed Kahrs LA, Burgner J, Klenzner T, Raczkowsky J, Schipper J, Wörn H (2010) Planning and simulation of microsurgical laser bone ablation. Int J Comput Assist Radiol Surg 5:155–162CrossRefPubMed
24.
go back to reference Zhang Y, Pfeiffer T, Weller M, Wieser W, Huber R, Raczkowsky J, Schipper J, Wörn H, Klenzner T (2014) Optical coherence tomography guided laser cochleostomy: towards the accuracy on tens of micrometer scale. Biomed Res Int 11:251–284 Zhang Y, Pfeiffer T, Weller M, Wieser W, Huber R, Raczkowsky J, Schipper J, Wörn H, Klenzner T (2014) Optical coherence tomography guided laser cochleostomy: towards the accuracy on tens of micrometer scale. Biomed Res Int 11:251–284
Metadata
Title
Comparative microstructural analysis of bone osteotomies after cutting by computer-assisted robot-guided laser osteotome and piezoelectric osteotome: an in vivo animal study
Authors
Marcello Augello
Waldemar Deibel
Katja Nuss
Philippe Cattin
Philipp Jürgens
Publication date
01-09-2018
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 7/2018
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-018-2502-0

Other articles of this Issue 7/2018

Lasers in Medical Science 7/2018 Go to the issue