Skip to main content
Top
Published in: Lasers in Medical Science 1/2007

01-03-2007 | Original article

Comparative evaluation of the effects of Nd:YAG and Er:YAG laser in dentin hypersensitivity treatment

Authors: Reza Birang, Jamshid Poursamimi, Norbert Gutknecht, Friedrich Lampert, Maziar Mir

Published in: Lasers in Medical Science | Issue 1/2007

Login to get access

Abstract

Dentin hypersensitivity (DH) is one of the most common complications that affect patients after periodontal therapy. So far, many investigators have successfully used different types of laser on DH treatment. The aim of this study was to evaluate the comparative effect of Nd:YAG laser and Er:YAG laser on human teeth desensitization. A group of nine patients with a total of 63 chronic hypersensitive teeth were selected. Each one of them should at least have three hypersensitive teeth. These teeth were randomly allocated into three groups. Group 1, Nd:YAG laser (1 W, 15 Hz, 60 s, two times); group 2, Er:YAG laser (100 mJ, 3 Hz, 60 s, two times); and group 3 serves as control group without any treatment. Assessment of pain was performed by a visual analysing scale (VAS) after stimulation of sensitive tooth by using the sharp tip of an explorer. This test was performed before treatment, immediately after that and at 1-, 3- and 6-month intervals after treatment by one blinded examiner. Analysis of VAS score between the three groups at the time of treatment did not show any significant difference (p = 0.506). However, by using repeated-measurement analysis of variance test, significant differences were seen in the three groups between before-treatment VAS score and after treatment (p < 0.0005). This statistically significant difference in the control group demonstrated a placebo effect. However, the effect of using Nd:YAG and Er:YAG lasers was stronger than this placebo effect, so that after removing the effect of the placebo, differences immediately after, 1, 3 and 6 months post treatment between all three groups still were statistically highly significant (p < 0.0005). Compared to the Er:YAG laser group, using Nd:YAG laser resulted in a significant reduction of VAS score at each follow-up examination (p < 0.0005). Although using Nd:YAG and Er:YAG laser in desensitization of hypersensitive teeth showed a placebo effect limited to a short time, results of this study demonstrated that both of these lasers have an acceptable therapeutic effect. The observed effects seemed to last for at least 6 months. It was concluded that Nd:YAG laser is more effective than Er:YAG laser in reduction of patients’ pain.
Literature
1.
go back to reference Rees JS, Addy M (2002) A cross-sectional study of dentine hypersensitivity. J Clin Periodontol 29:997–1003PubMedCrossRef Rees JS, Addy M (2002) A cross-sectional study of dentine hypersensitivity. J Clin Periodontol 29:997–1003PubMedCrossRef
2.
go back to reference Klokkevol PR, Carranza FA, Takei HH (2002) General principles of periodontal surgery. In: Newman M, Takei H, Carranza FA (eds) Carranza’s clinical periodontology. WB Sanders, Philadelphia, pp 725–736 Klokkevol PR, Carranza FA, Takei HH (2002) General principles of periodontal surgery. In: Newman M, Takei H, Carranza FA (eds) Carranza’s clinical periodontology. WB Sanders, Philadelphia, pp 725–736
3.
go back to reference Bergenholtz G, Hasselgren G (2003) Endodontics and periodontics. In: Lindhe J, Karring T, Lang NP (eds) Clinical periodontology and implant dentistry, 4th ed. Blackwell Munksgard, Copenhagen, pp 318–351 Bergenholtz G, Hasselgren G (2003) Endodontics and periodontics. In: Lindhe J, Karring T, Lang NP (eds) Clinical periodontology and implant dentistry, 4th ed. Blackwell Munksgard, Copenhagen, pp 318–351
4.
go back to reference Jacobson PL, Gretchen B (2001) Clinical dentine hypersensitivity: understanding the causes and prescribing a treatment. J Contemp Dent Pract 2:1–8 Jacobson PL, Gretchen B (2001) Clinical dentine hypersensitivity: understanding the causes and prescribing a treatment. J Contemp Dent Pract 2:1–8
5.
go back to reference Kimura Y, Wilder-Smith P, Matsumoto K (2000) Treatment of dentine hypersensitivity by lasers: a review. J Clin Periodontol 27:715–721PubMedCrossRef Kimura Y, Wilder-Smith P, Matsumoto K (2000) Treatment of dentine hypersensitivity by lasers: a review. J Clin Periodontol 27:715–721PubMedCrossRef
6.
go back to reference Lier BB, Rosing CK, Aass AM, Gjermo P (2002) Treatment of dentine hypersensitivity by Nd:YAG laser. J Clin Periodontol 29:501–506PubMedCrossRef Lier BB, Rosing CK, Aass AM, Gjermo P (2002) Treatment of dentine hypersensitivity by Nd:YAG laser. J Clin Periodontol 29:501–506PubMedCrossRef
7.
go back to reference Schwarz F, Arweiler N, George T, Reich E (2002) Desensitizing effects of an Er:YAG laser of hypersensitive dentine. J Clin Periodontol 29:211–215PubMedCrossRef Schwarz F, Arweiler N, George T, Reich E (2002) Desensitizing effects of an Er:YAG laser of hypersensitive dentine. J Clin Periodontol 29:211–215PubMedCrossRef
8.
go back to reference Ide M, Wilson RF, Ashley FP (2001) The reproducibility of methods of assessment for cervical dentine hypersensitivity. J Clin Periodontol 28:16–22PubMedCrossRef Ide M, Wilson RF, Ashley FP (2001) The reproducibility of methods of assessment for cervical dentine hypersensitivity. J Clin Periodontol 28:16–22PubMedCrossRef
9.
go back to reference Gillam GD, Newman HN (1993) Assessment of pain in cervical dentinal sensitivity studies. A review. J Clin Periodontol 20:383–394PubMedCrossRef Gillam GD, Newman HN (1993) Assessment of pain in cervical dentinal sensitivity studies. A review. J Clin Periodontol 20:383–394PubMedCrossRef
10.
go back to reference Gutknecht N, Moritz A, Dercks HW, Lampert F (1997) Treatment of hypersensitive teeth using neodymium: yttrium–aluminum–garnet lasers: a comparison of the use of various settings in an in vivo study. J Clin Laser Med Surg 15(4):171–174PubMed Gutknecht N, Moritz A, Dercks HW, Lampert F (1997) Treatment of hypersensitive teeth using neodymium: yttrium–aluminum–garnet lasers: a comparison of the use of various settings in an in vivo study. J Clin Laser Med Surg 15(4):171–174PubMed
11.
go back to reference Harper PR, Midda M (1992) Nd:YAG laser treatment of dentinal hypersensitivity. Br Dent J 172:13–16 Harper PR, Midda M (1992) Nd:YAG laser treatment of dentinal hypersensitivity. Br Dent J 172:13–16
12.
go back to reference Matsumoto K, Funai H, Shirasuka T, Wakabayashi H (1985) Effects of Nd:YAG laser in treatment of cervical hypersensitive dentine. Japanese J Conserv Dent 28:760–765 Matsumoto K, Funai H, Shirasuka T, Wakabayashi H (1985) Effects of Nd:YAG laser in treatment of cervical hypersensitive dentine. Japanese J Conserv Dent 28:760–765
13.
go back to reference Gelsky SC, White JM, Pruthi VK (1993) The effectiveness of the Nd:YAG laser in the treatment of dental hypersensitivity. J Can Dent Assoc 59(4):377–378, 383–6 Gelsky SC, White JM, Pruthi VK (1993) The effectiveness of the Nd:YAG laser in the treatment of dental hypersensitivity. J Can Dent Assoc 59(4):377–378, 383–6
14.
go back to reference Lan WH, Liu HC, Lin CP (1999) The combined occluding effect of sodium fluoride varnish and Nd:YAG laser irradiation on human dentinal tubules. J Endod 25:424–426PubMed Lan WH, Liu HC, Lin CP (1999) The combined occluding effect of sodium fluoride varnish and Nd:YAG laser irradiation on human dentinal tubules. J Endod 25:424–426PubMed
15.
go back to reference Lan WH, Lee BS, Liu HC, Lin CP (2004) Morphologic study of Nd:YAG laser usage in treatment of dentinal hypersensitivity. J Endod 30:131–134PubMedCrossRef Lan WH, Lee BS, Liu HC, Lin CP (2004) Morphologic study of Nd:YAG laser usage in treatment of dentinal hypersensitivity. J Endod 30:131–134PubMedCrossRef
16.
go back to reference Yonaya K, Kimura Y, Matsumoto K (1999) Treatment of cervical dentin hypersensitivity by various methods using pulsed Nd:YAG laser. J Clin Laser Med Surg 17:205–210 Yonaya K, Kimura Y, Matsumoto K (1999) Treatment of cervical dentin hypersensitivity by various methods using pulsed Nd:YAG laser. J Clin Laser Med Surg 17:205–210
17.
go back to reference Theodoro LH, Hypek P, Bachman L, Garcia VG, Sampaio J (2003) Effect of Er:YAG and diode laser irradiation on the root surface: morphologic and thermal analysis. J Periodontal 74:838–843CrossRef Theodoro LH, Hypek P, Bachman L, Garcia VG, Sampaio J (2003) Effect of Er:YAG and diode laser irradiation on the root surface: morphologic and thermal analysis. J Periodontal 74:838–843CrossRef
Metadata
Title
Comparative evaluation of the effects of Nd:YAG and Er:YAG laser in dentin hypersensitivity treatment
Authors
Reza Birang
Jamshid Poursamimi
Norbert Gutknecht
Friedrich Lampert
Maziar Mir
Publication date
01-03-2007
Publisher
Springer-Verlag
Published in
Lasers in Medical Science / Issue 1/2007
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-006-0412-z

Other articles of this Issue 1/2007

Lasers in Medical Science 1/2007 Go to the issue