Skip to main content
Top
Published in: Lasers in Medical Science 8/2019

01-10-2019 | Colon Cancer | Original Article

Evaluation of nonlinear optical behavior of mouse colon cancer cell line CT26 in hyperthermia treatment

Authors: Alireza Ghader, Arezoo Mohammadi Gazestani, Soraya Emamgholizadeh Minaei, Ali Abbasian Ardakani, Samideh Khoei, Salman Mohajer, Mohammad Hosein Majles Ara

Published in: Lasers in Medical Science | Issue 8/2019

Login to get access

Abstract

Hyperthermia treatment can induce component changes on cell. This study explored the potential of Z-scan to improve accuracy in the identification of subtle differences in mouse colon cancer cell line CT26 during hyperthermia treatment. Twenty-one samples were subjected individually to treatment of hyperthermia at 41, 43, and 45 °C. Each hyperthermia treatment was done in six different time (15, 30, 45, 60, 75, and 90 min). Two optical setups were used to investigate the linear and nonlinear optical behavior of samples. Prior to the Z-scan technique, all samples were fixed with 1 mL of 5% paraformaldehyde. The linear optical setup indicated that extinction coefficient cannot monitor cell changes at different treatment regimes. But the nonlinear behavior of CT26 in all hyperthermia treatment regimens was different. By increasing the time and/or temperature of hyperthermia treatments, change in the sign of nonlinear refractive index from negative to positive occurred in earlier time intervals. This phenomenon was seen for 41, 43, and 45 °C in 75, 60, and 45 min, respectively. The results showed that the Z-scan technique is a reliable method with the potential to characterize cell changes during hyperthermia treatment regimes. Nonlinear refractive index can be used as a new index for evaluation of cell damage.
Literature
8.
go back to reference Baronzio GF, Hager ED (2008) Hyperthermia in cancer treatment: a primer. Springer Science & Business Media Baronzio GF, Hager ED (2008) Hyperthermia in cancer treatment: a primer. Springer Science & Business Media
14.
go back to reference Gomaa IE, Gaber SAA, Bhatt S, Liehr T, Glei M, El-Tayeb TA, Abdel-Kader MH (2015) In vitro cytotoxicity and genotoxicity studies of gold nanoparticles-mediated photo-thermal therapy versus 5-fluorouracil. J Nanopart Res 2:1–11. https://doi.org/10.1007/s1105 CrossRef Gomaa IE, Gaber SAA, Bhatt S, Liehr T, Glei M, El-Tayeb TA, Abdel-Kader MH (2015) In vitro cytotoxicity and genotoxicity studies of gold nanoparticles-mediated photo-thermal therapy versus 5-fluorouracil. J Nanopart Res 2:1–11. https://​doi.​org/​10.​1007/​s1105 CrossRef
26.
go back to reference Warters RL, Henle KJ (1982) DNA degradation in Chinese hamster ovary cells after exposure to hyperthermia. Cancer Res 42:4427–4432PubMed Warters RL, Henle KJ (1982) DNA degradation in Chinese hamster ovary cells after exposure to hyperthermia. Cancer Res 42:4427–4432PubMed
33.
go back to reference Tuchin VV (2007) Tissue optics: light scattering methods and instruments for medical diagnosis, vol 13. SPIE press, BellinghamCrossRef Tuchin VV (2007) Tissue optics: light scattering methods and instruments for medical diagnosis, vol 13. SPIE press, BellinghamCrossRef
34.
go back to reference Maeda D, Iwai T, Namiki M (2018) Diffuse light reflectometry for measuring scattering and absorption coefficients of a biological tissue. In: Biomedical Imaging and Sensing Conference. Int Society for Optics and Photonics, p 107111L. https://doi.org/10.1117/12.2319355 Maeda D, Iwai T, Namiki M (2018) Diffuse light reflectometry for measuring scattering and absorption coefficients of a biological tissue. In: Biomedical Imaging and Sensing Conference. Int Society for Optics and Photonics, p 107111L. https://​doi.​org/​10.​1117/​12.​2319355
36.
go back to reference Nishidate I, Mustari A, Kawauchi S, Sato S, Sato M, Kokubo Y (2017) In vivo imaging of tissue scattering parameter and cerebral hemodynamics in rat brain with a digital red-green-blue camera. SPIE BiOS Int Society for Opt and Photonics, 100500O-100508. https://doi.org/10.1117/12.2251109 Nishidate I, Mustari A, Kawauchi S, Sato S, Sato M, Kokubo Y (2017) In vivo imaging of tissue scattering parameter and cerebral hemodynamics in rat brain with a digital red-green-blue camera. SPIE BiOS Int Society for Opt and Photonics, 100500O-100508. https://​doi.​org/​10.​1117/​12.​2251109
37.
go back to reference Boyd RW (2008) Nonlinear opt. Academic Press Boyd RW (2008) Nonlinear opt. Academic Press
Metadata
Title
Evaluation of nonlinear optical behavior of mouse colon cancer cell line CT26 in hyperthermia treatment
Authors
Alireza Ghader
Arezoo Mohammadi Gazestani
Soraya Emamgholizadeh Minaei
Ali Abbasian Ardakani
Samideh Khoei
Salman Mohajer
Mohammad Hosein Majles Ara
Publication date
01-10-2019
Publisher
Springer London
Published in
Lasers in Medical Science / Issue 8/2019
Print ISSN: 0268-8921
Electronic ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-019-02759-8

Other articles of this Issue 8/2019

Lasers in Medical Science 8/2019 Go to the issue