Abstract

Background

The Labcor Dokimos Plus (LDP) is a stented externally mounted pericardial aortic bioprosthesis, which was recently introduced in Europe. Aims of the study are evaluation of operative and postoperative results as well as hemodynamic performance.

Methods

One hundred consecutive patients with a mean age of 65.9 ± 10.7 years (range 35–87) and a mean EuroSCORE II of 3.1 ± 3.9 (range 0.67–24.5) underwent aortic valve replacement with the LDP. Mean valve-size was 25.2 ± 1.7 mm. Concomitant procedures were performed in 34% of the cases. Postoperative clinical data were analyzed and hemodynamic performance of the prostheses was evaluated by transthoracic echocardiography. Clinical follow-up was 100%, echocardiographic follow-up was 93% complete.

Results

Intraoperatively no peculiarities occurred. Mean cross clamp times for isolated and complex procedures were 74.5 ± 20.0 min and 103.7 ± 37.1 min, respectively. Patients were extubated after a mean of 9.4 ± 15.8 h. There were no perioperative strokes. Bleeding events occurred in 4 patients. 30-day-mortality was 2%. One case of early endocarditis occurred. Echocardiography showed maximum and mean pressure gradients of 18.1 ± 6.4 and 9.6 ± 3.7 mmHg, respectively. Correspondingly to valve sizes 21, 23, 25 and 27 mm, mean pressure gradients were 17.3, 9.5, 8.5 and 10.2 mmHg, effective orifice areas were 1.92, 1.79, 2.0, 2.16 cm2 and indexed effective orifice areas were 1.08, 0.95, 0.99 and 1.01 cm2/m2, respectively. No relevant regurgitations occurred.

Conclusions

The LDP showed operatively no peculiarities and a satisfactory clinical outcome with low perioperative morbidity and mortality. The hemodynamic performance of the implanted valve sizes was satisfactory.
Literature
1.
go back to reference Garcia-Bengochea JB, Casagrande I, Gonzalez-Juanatey JR, Puig L, Rubio J, Duran D, et al. The new Labcor-Santiago pericardial bioprosthesis. J Card Surg. 1991;6:613–9.CrossRefPubMed Garcia-Bengochea JB, Casagrande I, Gonzalez-Juanatey JR, Puig L, Rubio J, Duran D, et al. The new Labcor-Santiago pericardial bioprosthesis. J Card Surg. 1991;6:613–9.CrossRefPubMed
2.
go back to reference Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, et al. Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2012;33:2451–96.CrossRefPubMed Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, et al. Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2012;33:2451–96.CrossRefPubMed
3.
go back to reference Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, Guyton RA, et al. 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease. J Am Coll Cardiol. 2014;63:e57–e185.CrossRefPubMed Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP, Guyton RA, et al. 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease. J Am Coll Cardiol. 2014;63:e57–e185.CrossRefPubMed
4.
go back to reference David TE, Armstrong S, Maganti M. Hancock II Bioprosthesis for Aortic Valve Replacement: The Gold Standard of Bioprosthetic Valves Durability? Ann Thorac Surg. 2010;90:775.CrossRefPubMed David TE, Armstrong S, Maganti M. Hancock II Bioprosthesis for Aortic Valve Replacement: The Gold Standard of Bioprosthetic Valves Durability? Ann Thorac Surg. 2010;90:775.CrossRefPubMed
5.
go back to reference McClure RS, Narayanasamy N, Wiegerinck E, Lipsitz S, Maloney A, Byrne JG, et al. Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients. Ann Thorac Surg. 2010;89:1410–6.CrossRefPubMed McClure RS, Narayanasamy N, Wiegerinck E, Lipsitz S, Maloney A, Byrne JG, et al. Late Outcomes for Aortic Valve Replacement With the Carpentier-Edwards Pericardial Bioprosthesis: Up to 17-Year Follow-Up in 1,000 Patients. Ann Thorac Surg. 2010;89:1410–6.CrossRefPubMed
6.
7.
go back to reference Dell’Aquila AM, Schlarb D, Schneider SRB, Sindermann JR, Hoffmeier A, Kaleschke G, et al. Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: an initial single-centre experience. Interact Cardiovasc Thorac Surg. 2013;16:112–5.CrossRefPubMed Dell’Aquila AM, Schlarb D, Schneider SRB, Sindermann JR, Hoffmeier A, Kaleschke G, et al. Clinical and echocardiographic outcomes after implantation of the Trifecta aortic bioprosthesis: an initial single-centre experience. Interact Cardiovasc Thorac Surg. 2013;16:112–5.CrossRefPubMed
8.
go back to reference Nashef SAM, Roques F, Sharples LD, Nilsson J, Smith C, Goldstone AR, et al. EuroSCORE II. Eur J Cardio-Thorac Surg Off J Eur Assoc Cardio-Thorac Surg. 2012;41:734–45.CrossRef Nashef SAM, Roques F, Sharples LD, Nilsson J, Smith C, Goldstone AR, et al. EuroSCORE II. Eur J Cardio-Thorac Surg Off J Eur Assoc Cardio-Thorac Surg. 2012;41:734–45.CrossRef
9.
go back to reference Conte J, Weissman N, Dearani JA, Bavaria J, Heimansohn D, Dembitsky W, et al. A North American, Prospective, Multicenter Assessment of the Mitroflow Aortic Pericardial Prosthesis. Ann Thorac Surg. 2010;90:144.CrossRefPubMed Conte J, Weissman N, Dearani JA, Bavaria J, Heimansohn D, Dembitsky W, et al. A North American, Prospective, Multicenter Assessment of the Mitroflow Aortic Pericardial Prosthesis. Ann Thorac Surg. 2010;90:144.CrossRefPubMed
10.
go back to reference Riess F-C, Bader R, Cramer E, Hansen L, Kleijnen B, Wahl G, et al. Hemodynamic performance of the Medtronic Mosaic porcine bioprosthesis up to ten years. Ann Thorac Surg. 2007;83:1310–8.CrossRefPubMed Riess F-C, Bader R, Cramer E, Hansen L, Kleijnen B, Wahl G, et al. Hemodynamic performance of the Medtronic Mosaic porcine bioprosthesis up to ten years. Ann Thorac Surg. 2007;83:1310–8.CrossRefPubMed
11.
go back to reference Beholz S, Claus B, Dushe S, Konertz W. Operative technique and early hemodynamic results with the Freedom Solo valve. J Heart Valve Dis. 2006;15:429–32.PubMed Beholz S, Claus B, Dushe S, Konertz W. Operative technique and early hemodynamic results with the Freedom Solo valve. J Heart Valve Dis. 2006;15:429–32.PubMed
12.
go back to reference Ugur M, Suri RM, Daly RC, Dearani JA, Park SJ, Joyce LD, et al. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses. J Thorac Cardiovasc Surg. 2014;148:1940–6.CrossRefPubMed Ugur M, Suri RM, Daly RC, Dearani JA, Park SJ, Joyce LD, et al. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses. J Thorac Cardiovasc Surg. 2014;148:1940–6.CrossRefPubMed
14.
go back to reference Walther T, Autschbach R, Falk V, Baryalei M, Scheidt A, Dalichau H, et al. The stentless Toronto SPV bioprosthesis for aortic valve replacement. Cardiovasc Surg Lond Engl. 1996;4:536–42.CrossRef Walther T, Autschbach R, Falk V, Baryalei M, Scheidt A, Dalichau H, et al. The stentless Toronto SPV bioprosthesis for aortic valve replacement. Cardiovasc Surg Lond Engl. 1996;4:536–42.CrossRef
Metadata
Title
Clinical outcome and hemodynamic behavior of the Labcor Dokimos Plus aortic valve
Authors
Torsten Christ
Konstantin Zhigalov
Wolfgang Konertz
Sebastian Holinski
Publication date
01-12-2016
Publisher
BioMed Central
Published in
Journal of Cardiothoracic Surgery / Issue 1/2016
Electronic ISSN: 1749-8090
DOI
https://doi.org/10.1186/s13019-016-0561-5

Other articles of this Issue 1/2016

Journal of Cardiothoracic Surgery 1/2016 Go to the issue