Abstract

Background

Midshaft clavicle fractures are one of the most familiar fractures. And, dual small plate fixation has been reported as can minimize hardware-related complications. However, the biomechanical properties of the dual small plate fixation have not yet been thoroughly evaluated. Here, we report the results of a finite element analysis of the biomechanical properties of midshaft clavicle fractures treated with dual small plating and superior and anteroinferior single plate fixation.

Methods

A three-dimensional (3D) finite element model of the midshaft clavicle fractures was created, whose 4-mm transverse fracture gap, having an angle < 30 degree and devoid of overlapping triangles, was simulated between the fractured segments of the middle-shaft of the clavicle. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis.

Results

No significant differences were found between dual plating, superior or anteroinferior single plating in cantilever bending, axial compression, and axial torsion. Dual plating with a smaller plate-screw construct is biomechanically eligible to compare with superior and anteroinferior single plate fixation using larger plate-screw constructs.

Conclusions

This study demonstrated that larger plate-screw constructs for the treatment of simple are placed clavicular fractures; however, weight-bearing and exorbitant shoulder activity should be avoided after the operation. Therefore, dual plating may provide a viable option for fixing midshaft clavicle fractures and, thus, may be preferred for patients who need early activity.
Appendix
Available only for authorised users
Literature
1.
go back to reference Zlowodzki M, et al. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the evidence-based orthopaedic trauma working group. J Orthop Trauma. 2005;19(7):504–7.CrossRef Zlowodzki M, et al. Treatment of acute midshaft clavicle fractures: systematic review of 2144 fractures: on behalf of the evidence-based orthopaedic trauma working group. J Orthop Trauma. 2005;19(7):504–7.CrossRef
2.
go back to reference Nourian A, et al. Midshaft fractures of the clavicle: a meta-analysis comparing surgical fixation using anteroinferior plating versus superior plating. J Orthop Trauma. 2017;31(9):461–7.CrossRef Nourian A, et al. Midshaft fractures of the clavicle: a meta-analysis comparing surgical fixation using anteroinferior plating versus superior plating. J Orthop Trauma. 2017;31(9):461–7.CrossRef
3.
go back to reference Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am, 2007. 89(1): p. 1-10. Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. A multicenter, randomized clinical trial. J Bone Joint Surg Am, 2007. 89(1): p. 1-10.
4.
go back to reference Kulshrestha V, Roy T, Audige L. Operative versus nonoperative management of displaced midshaft clavicle fractures: a prospective cohort study. J Orthop Trauma. 2011;25(1):31–8.CrossRef Kulshrestha V, Roy T, Audige L. Operative versus nonoperative management of displaced midshaft clavicle fractures: a prospective cohort study. J Orthop Trauma. 2011;25(1):31–8.CrossRef
5.
go back to reference Mirzatolooei F. Comparison between operative and nonoperative treatment methods in the management of comminuted fractures of the clavicle. Acta Orthop Traumatol Turc. 2011;45(1):34–40.CrossRef Mirzatolooei F. Comparison between operative and nonoperative treatment methods in the management of comminuted fractures of the clavicle. Acta Orthop Traumatol Turc. 2011;45(1):34–40.CrossRef
6.
go back to reference Robinson CM, et al. Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial. J Bone Joint Surg Am. 2013;95(17):1576–84.CrossRef Robinson CM, et al. Open reduction and plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a multicenter, randomized, controlled trial. J Bone Joint Surg Am. 2013;95(17):1576–84.CrossRef
7.
go back to reference Woltz S, Krijnen P, Schipper IB. Plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a meta-analysis of randomized controlled trials. J Bone Joint Surg Am. 2017;99(12):1051–7.CrossRef Woltz S, Krijnen P, Schipper IB. Plate fixation versus nonoperative treatment for displaced midshaft clavicular fractures: a meta-analysis of randomized controlled trials. J Bone Joint Surg Am. 2017;99(12):1051–7.CrossRef
8.
go back to reference Vander Have KL, et al. Operative versus nonoperative treatment of midshaft clavicle fractures in adolescents. J Pediatr Orthop. 2010;30(4):307–12.CrossRef Vander Have KL, et al. Operative versus nonoperative treatment of midshaft clavicle fractures in adolescents. J Pediatr Orthop. 2010;30(4):307–12.CrossRef
9.
go back to reference Demirhan M, et al. Biomechanical comparison of fixation techniques in midshaft clavicular fractures. J Orthop Trauma. 2011;25(5):272–8.CrossRef Demirhan M, et al. Biomechanical comparison of fixation techniques in midshaft clavicular fractures. J Orthop Trauma. 2011;25(5):272–8.CrossRef
10.
go back to reference Prasarn ML, et al. Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation. Arch Orthop Trauma Surg. 2015;135(12):1655–62.CrossRef Prasarn ML, et al. Dual mini-fragment plating for midshaft clavicle fractures: a clinical and biomechanical investigation. Arch Orthop Trauma Surg. 2015;135(12):1655–62.CrossRef
11.
go back to reference Shannon SF, et al. Extraperiosteal dual plate fixation of acute mid-shaft clavicle fractures: a technical trick. J Orthop Trauma. 2016;30(10):e346–50.CrossRef Shannon SF, et al. Extraperiosteal dual plate fixation of acute mid-shaft clavicle fractures: a technical trick. J Orthop Trauma. 2016;30(10):e346–50.CrossRef
12.
go back to reference Altamimi, S.A. and M.D. McKee, Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. Surgical technique. J Bone Joint Surg Am, 2008. 90 Suppl 2 Pt 1: p. 1-8. Altamimi, S.A. and M.D. McKee, Nonoperative treatment compared with plate fixation of displaced midshaft clavicular fractures. Surgical technique. J Bone Joint Surg Am, 2008. 90 Suppl 2 Pt 1: p. 1-8.
13.
go back to reference VanBeek C, et al. Precontoured plating of clavicle fractures: decreased hardware-related complications? Clin Orthop Relat Res. 2011;469(12):3337–43.CrossRef VanBeek C, et al. Precontoured plating of clavicle fractures: decreased hardware-related complications? Clin Orthop Relat Res. 2011;469(12):3337–43.CrossRef
14.
go back to reference Chen X, et al. Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures. Arch Orthop Trauma Surg. 2017;137(6):749–54.CrossRef Chen X, et al. Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures. Arch Orthop Trauma Surg. 2017;137(6):749–54.CrossRef
15.
go back to reference Czajka CM, et al. Symptomatic implant removal following dual mini-fragment plating for clavicular shaft fractures. J Orthop Trauma. 2017;31(4):236–40.CrossRef Czajka CM, et al. Symptomatic implant removal following dual mini-fragment plating for clavicular shaft fractures. J Orthop Trauma. 2017;31(4):236–40.CrossRef
16.
go back to reference Ziegler CG, et al. Low-profile dual small plate fixation is biomechanically similar to larger superior or anteroinferior single plate fixation of midshaft clavicle fractures. Am J Sports Med. 2019;47(11):2678–85.CrossRef Ziegler CG, et al. Low-profile dual small plate fixation is biomechanically similar to larger superior or anteroinferior single plate fixation of midshaft clavicle fractures. Am J Sports Med. 2019;47(11):2678–85.CrossRef
17.
go back to reference Ni M, et al. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures. Injury. 2016;47(8):1618–23.CrossRef Ni M, et al. Finite element analysis of locking plate and two types of intramedullary nails for treating mid-shaft clavicle fractures. Injury. 2016;47(8):1618–23.CrossRef
18.
go back to reference Cronskar M, Rasmussen J, Tinnsten M. Combined finite element and multibody musculoskeletal investigation of a fractured clavicle with reconstruction plate. Comput Methods Biomech Biomed Engin. 2015;18(7):740–8.CrossRef Cronskar M, Rasmussen J, Tinnsten M. Combined finite element and multibody musculoskeletal investigation of a fractured clavicle with reconstruction plate. Comput Methods Biomech Biomed Engin. 2015;18(7):740–8.CrossRef
19.
go back to reference Mei J, et al. Finite element analysis of the effect of cannulated screw placement and drilling frequency on femoral neck fracture fixation. Injury. 2014;45(12):2045–50.CrossRef Mei J, et al. Finite element analysis of the effect of cannulated screw placement and drilling frequency on femoral neck fracture fixation. Injury. 2014;45(12):2045–50.CrossRef
20.
go back to reference Carrera I, et al. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. Int Orthop. 2016;40(10):2163–9.CrossRef Carrera I, et al. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. Int Orthop. 2016;40(10):2163–9.CrossRef
21.
go back to reference Zeng L, et al. Titanium elastic nail (TEN) versus reconstruction plate repair of midshaft clavicular fractures: a finite element study. PLoS One. 2015;10(5):e0126131.CrossRef Zeng L, et al. Titanium elastic nail (TEN) versus reconstruction plate repair of midshaft clavicular fractures: a finite element study. PLoS One. 2015;10(5):e0126131.CrossRef
Metadata
Title
Finite element analysis of dual small plate fixation and single plate fixation for treatment of midshaft clavicle fractures
Authors
Fangxue Zhang
Fancheng Chen
Yuhan Qi
Zhi Qian
Shuo Ni
Zeyuan Zhong
Xu Zhang
Dejian Li
Baoqing Yu
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2020
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-020-01666-x

Other articles of this Issue 1/2020

Journal of Orthopaedic Surgery and Research 1/2020 Go to the issue