Skip to main content
Top
Published in: European Radiology 3/2011

01-03-2011 | Chest

Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients

Authors: François Pontana, Alain Duhamel, Julien Pagniez, Thomas Flohr, Jean-Baptiste Faivre, Anne-Lise Hachulla, Jacques Remy, Martine Remy-Jardin

Published in: European Radiology | Issue 3/2011

Login to get access

Abstract

Purpose

To evaluate the image quality of an iterative reconstruction algorithm (IRIS) in low-dose chest CT in comparison with standard-dose filtered back projection (FBP) CT.

Materials and methods

Eighty consecutive patients referred for a follow-up chest CT examination of the chest, underwent a low-dose CT examination (Group 2) in similar technical conditions to those of the initial examination, (Group 1) except for the milliamperage selection and the replacement of regular FBP reconstruction by iterative reconstructions using three (Group 2a) and five iterations (Group 2b).

Results

Despite a mean decrease of 35.5% in the dose-length-product, there was no statistically significant difference between Group 2a and Group 1 in the objective noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and distribution of the overall image quality scores. Compared to Group 1, objective image noise in Group 2b was significantly reduced with increased SNR and CNR and a trend towards improved image quality.

Conclusion

Iterative reconstructions using three iterations provide similar image quality compared with the conventionally used FBP reconstruction at 35% less dose, thus enabling dose reduction without loss of diagnostic information. According to our preliminary results, even higher dose reductions than 35% may be feasible by using more than three iterations.
Literature
1.
go back to reference Tsapaki V, Aldrich JE, Sharma R et al (2006) Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine head, chest, and abdominal CT- IAEA-coordinated Research Project. Radiology 240:828–834CrossRefPubMed Tsapaki V, Aldrich JE, Sharma R et al (2006) Dose reduction in CT while maintaining diagnostic confidence: Diagnostic reference levels at routine head, chest, and abdominal CT- IAEA-coordinated Research Project. Radiology 240:828–834CrossRefPubMed
2.
go back to reference Kubo T, Lin PJP, Stiller W, Takahashi M, Kauczor HU, Ohno Y, Hatabu H (2008) Radiation dose reduction in chest CT: a review. AJR 190:335–343CrossRefPubMed Kubo T, Lin PJP, Stiller W, Takahashi M, Kauczor HU, Ohno Y, Hatabu H (2008) Radiation dose reduction in chest CT: a review. AJR 190:335–343CrossRefPubMed
3.
go back to reference Mayo JR (2009) CT evaluation of diffuse infiltrative lung disease: dose considerations and optimal technique. J Thorac Imaging 24:252–259CrossRefPubMed Mayo JR (2009) CT evaluation of diffuse infiltrative lung disease: dose considerations and optimal technique. J Thorac Imaging 24:252–259CrossRefPubMed
4.
go back to reference Das M, Mahnken AH, Mühlenbruch G et al (2005) Individually-adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations. AJR 184:1437–1443PubMed Das M, Mahnken AH, Mühlenbruch G et al (2005) Individually-adapted examination protocols for reduction of radiation exposure for 16-MDCT chest examinations. AJR 184:1437–1443PubMed
5.
go back to reference De Maertelaer TD, Gevenois PA V (2003) Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR 181:331–334PubMed De Maertelaer TD, Gevenois PA V (2003) Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR 181:331–334PubMed
6.
go back to reference Mulkens TH, Bellinck P, Baeyaert M, Ghysen D, Van Dick X, Mussen E, Venstermans C, Termote JL (2005) Use of an automatic exposure control mechanism for dose optimization in multidetector row CT examinations: clinical evaluation. Radiology 237:213–223CrossRefPubMed Mulkens TH, Bellinck P, Baeyaert M, Ghysen D, Van Dick X, Mussen E, Venstermans C, Termote JL (2005) Use of an automatic exposure control mechanism for dose optimization in multidetector row CT examinations: clinical evaluation. Radiology 237:213–223CrossRefPubMed
7.
go back to reference Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JO, Saini S (2004) Strategies for CT radiation dose optimization. Radiology 230:619–628CrossRefPubMed Kalra MK, Maher MM, Toth TL, Hamberg LM, Blake MA, Shepard JO, Saini S (2004) Strategies for CT radiation dose optimization. Radiology 230:619–628CrossRefPubMed
8.
go back to reference Long FR (2007) High-resolution computed tomography of the lung in children with cystic fibrosis. Technical factors. Proc Am Thorac Soc 4(4):306–309CrossRefPubMed Long FR (2007) High-resolution computed tomography of the lung in children with cystic fibrosis. Technical factors. Proc Am Thorac Soc 4(4):306–309CrossRefPubMed
9.
go back to reference Shepp LA, Vardi Y (1982) Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1:113–122CrossRefPubMed Shepp LA, Vardi Y (1982) Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1:113–122CrossRefPubMed
10.
go back to reference Lange K, Carson R (1984) EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8:306–16PubMed Lange K, Carson R (1984) EM reconstruction algorithms for emission and transmission tomography. J Comput Assist Tomogr 8:306–16PubMed
11.
go back to reference Lewitt RM, Matej S (2003) Overview of methods for image reconstruction from projections in emission computed tomography. Proc IEEE 91:1588–1611CrossRef Lewitt RM, Matej S (2003) Overview of methods for image reconstruction from projections in emission computed tomography. Proc IEEE 91:1588–1611CrossRef
12.
go back to reference Thibault JB, Sauer KD, Bouman CA, Hsieh J (2007) A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 34:4526–4544CrossRefPubMed Thibault JB, Sauer KD, Bouman CA, Hsieh J (2007) A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 34:4526–4544CrossRefPubMed
13.
go back to reference Pontana F, Pagniez J, Flohr T, Faivre JB, Duhamel A, Remy J, Remy-Jardin M (2010) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol Pontana F, Pagniez J, Flohr T, Faivre JB, Duhamel A, Remy J, Remy-Jardin M (2010) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol
14.
go back to reference Szucs-Farkas Z, Strautz T, Patak MA, Kurmann L, Vock P, Schindera ST (2009) Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients. Eur Radiol 19:1914–1922CrossRefPubMed Szucs-Farkas Z, Strautz T, Patak MA, Kurmann L, Vock P, Schindera ST (2009) Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients. Eur Radiol 19:1914–1922CrossRefPubMed
15.
go back to reference Bruder H, Raupach R, Sedlmair M, Sunnegardh J, Stierstorfer K, Flohr TG (2010) Reduction of radiation dose in CT with an FBP-based iterative reconstruction technique. ECR B-568 Bruder H, Raupach R, Sedlmair M, Sunnegardh J, Stierstorfer K, Flohr TG (2010) Reduction of radiation dose in CT with an FBP-based iterative reconstruction technique. ECR B-568
16.
go back to reference Prakash P, Kalra MK, Digumarthy SR, Hsieh J, Pien H, Singh S, Gilman MD, Shepard JAO (2010) Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 34:40–45CrossRefPubMed Prakash P, Kalra MK, Digumarthy SR, Hsieh J, Pien H, Singh S, Gilman MD, Shepard JAO (2010) Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 34:40–45CrossRefPubMed
Metadata
Title
Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients
Authors
François Pontana
Alain Duhamel
Julien Pagniez
Thomas Flohr
Jean-Baptiste Faivre
Anne-Lise Hachulla
Jacques Remy
Martine Remy-Jardin
Publication date
01-03-2011
Publisher
Springer-Verlag
Published in
European Radiology / Issue 3/2011
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1991-4

Other articles of this Issue 3/2011

European Radiology 3/2011 Go to the issue