Skip to main content
Top
Published in: Graefe's Archive for Clinical and Experimental Ophthalmology 3/2003

01-03-2003 | Clinical Investigation

Changes in macular thickness and depth of anterior chamber in patients after filtration surgery

Authors: Gulsara Karasheva, Winfried Goebel, Thomas Klink, Wolfgang Haigis, Franz Grehn

Published in: Graefe's Archive for Clinical and Experimental Ophthalmology | Issue 3/2003

Login to get access

Abstract

Background

The prospective study was undertaken to analyze retinal thickness of the macula and anterior chamber depth in patients undergoing filtration surgery at different times of follow-up.

Methods

Forty-four patients (45 eyes) were included. The thickness of the fovea and the extrafoveal retina were measured using optical coherence tomography (OCT). Anterior chamber depth was determined using the IOLMaster. All standard clinical examination and measurements were performed prior to surgery, at the 2nd day (1–3 days), 1 week, 1 month and 3 months after surgery.

Results

Preoperative IOP under topical medication was 25.5±7.5 mmHg. IOP was significantly decreased at all postoperative visits (P<0.0001): 10.8±5.9 mmHg at the 2nd day, 10.4±5.2 mmHg after 1 week, 11.7±4.4 mmHg after 1 month and 11.4±3.6 mmHg after 3 months. No patient in our study suffered from prolonged postoperative hypotony (IOP<5 mmHg). Foveal thickness at the 2nd day, 1 week and 1 month were elevated compared with baseline (P<0.004). Macular thickness changed from 164±20 μm before surgery to 168±20 μm after 2 days, 170±21 μm after 1 week, 173±19 μm after 1 month and 165±16 μm after 3 months. Mean thickness of the extrafoveal retina did not change significantly. Also, there were no significant changes in anterior chamber depth. There was no significant correlation between reduction of IOP and retinal thickness or anterior chamber depth.

Conclusion

The reduction of IOP after filtration surgery leads to a moderate increase in foveal retinal thickness over approximately 1 month and is not associated with shallowing of the anterior chamber, provided that prolonged postoperative hypotony is avoided with the surgical technique used.
Literature
1.
go back to reference Cohen SM, Flynn HW, Palmberg PF, Gass DM, Grajewski AL, Parrish RK (1995) Treatment of hypotony maculopathy after trabeculotomy. Ophthalmic Surg Lasers 26:435–441PubMed Cohen SM, Flynn HW, Palmberg PF, Gass DM, Grajewski AL, Parrish RK (1995) Treatment of hypotony maculopathy after trabeculotomy. Ophthalmic Surg Lasers 26:435–441PubMed
2.
go back to reference Gass DM. Hypotony maculopathy. In: Bellows JG (ed) (1972) Contemporary ophthalmology: honoring Sir Stewart Duke-Elder. Williams & Wilkins, Baltimore, pp 343–366 Gass DM. Hypotony maculopathy. In: Bellows JG (ed) (1972) Contemporary ophthalmology: honoring Sir Stewart Duke-Elder. Williams & Wilkins, Baltimore, pp 343–366
3.
go back to reference Goins K, Smith T, Kinkeer R, Lewis J (1990) Axial anterior chamber depth after trabeculectomy. Ophthalmologica 200(4): 177–180PubMed Goins K, Smith T, Kinkeer R, Lewis J (1990) Axial anterior chamber depth after trabeculectomy. Ophthalmologica 200(4): 177–180PubMed
4.
go back to reference Göbel W, Hartmann F, Haigis W (2001) The correlation between retina thickness and axial length as well as age, measured by optical coherence tomography. Ophthalmologe 98:157–162CrossRefPubMed Göbel W, Hartmann F, Haigis W (2001) The correlation between retina thickness and axial length as well as age, measured by optical coherence tomography. Ophthalmologe 98:157–162CrossRefPubMed
5.
go back to reference Grewing R, Becker H (2000) Retinal thickness immediately after cataract surgery measured by optical coherence tomography. Ophthalmic Surg 31(3): 215–217 Grewing R, Becker H (2000) Retinal thickness immediately after cataract surgery measured by optical coherence tomography. Ophthalmic Surg 31(3): 215–217
6.
go back to reference Haigis W, Lege BAM (2000) Ultraschallbiometrie und optische Biometrie. In: Kohnen T, Ohrloff C, Wenzel M (eds) 13. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation und Refraktive Chirurgie, 11–13.03.99, Frankfurt. Biermann, Cologne, pp 180–186 Haigis W, Lege BAM (2000) Ultraschallbiometrie und optische Biometrie. In: Kohnen T, Ohrloff C, Wenzel M (eds) 13. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation und Refraktive Chirurgie, 11–13.03.99, Frankfurt. Biermann, Cologne, pp 180–186
7.
go back to reference Haigis W, Lege BAM (2000) Akustische und optische Biometrie im klinischen Einsatz. In: Wenzel M, Kohnen T, Blumer B (ed) 14. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation und Refraktive Chirurgie, 18–19.02.2000, Luzern/Schweiz. Biermann, Cologne, pp 73–78 Haigis W, Lege BAM (2000) Akustische und optische Biometrie im klinischen Einsatz. In: Wenzel M, Kohnen T, Blumer B (ed) 14. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen-Implantation und Refraktive Chirurgie, 18–19.02.2000, Luzern/Schweiz. Biermann, Cologne, pp 73–78
8.
go back to reference Hee MR, Izatt JA, Swanson EA, Huang D, Schuman JS, Lin CP, Puliafito CA, Fujimoto JG (1995) Optical coherence tomography of the human retina. Arch Ophthalmol 113:325–332PubMed Hee MR, Izatt JA, Swanson EA, Huang D, Schuman JS, Lin CP, Puliafito CA, Fujimoto JG (1995) Optical coherence tomography of the human retina. Arch Ophthalmol 113:325–332PubMed
9.
go back to reference Kao SF, Lichter PR, Musch DC (1989) Anterior chamber depth following filtration surgery. Ophthalmic Surg 20(5): 332–336PubMed Kao SF, Lichter PR, Musch DC (1989) Anterior chamber depth following filtration surgery. Ophthalmic Surg 20(5): 332–336PubMed
10.
go back to reference Klink T, Lieb WE, Göbel W (2000) Early and late optical coherence tomography (OCT) findings in patients with postoperative hypotony. Ophthalmologe 97:353–358CrossRefPubMed Klink T, Lieb WE, Göbel W (2000) Early and late optical coherence tomography (OCT) findings in patients with postoperative hypotony. Ophthalmologe 97:353–358CrossRefPubMed
11.
go back to reference Lam AK, Chan R, Pang PC (2001) The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Opthalmic Physiol Opt 21(6): 477–483CrossRef Lam AK, Chan R, Pang PC (2001) The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Opthalmic Physiol Opt 21(6): 477–483CrossRef
12.
go back to reference Lege BAM, Haigis W (2000) In: Kohnen T, Ohrloff C, Wenzel M (eds) 13. Kongress der Deutschsprachigen Gesellschaft fuer Intraokularlinsen-Implantation und Refraktive Chirurgie, 11–13.03.99, Frankfurt. Biermann, Cologne, pp 175–179 Lege BAM, Haigis W (2000) In: Kohnen T, Ohrloff C, Wenzel M (eds) 13. Kongress der Deutschsprachigen Gesellschaft fuer Intraokularlinsen-Implantation und Refraktive Chirurgie, 11–13.03.99, Frankfurt. Biermann, Cologne, pp 175–179
13.
go back to reference Martinez-Bello C, Rodrigues-Ares T, Pazos B, Capeans C, Sanchez-Salorio M (2000) Changes in anterior chamber depth and angle width after filtration surgery: a quantitative study using ultrasound biomicroscopy. J Glaucoma 9 (1): 51–55PubMed Martinez-Bello C, Rodrigues-Ares T, Pazos B, Capeans C, Sanchez-Salorio M (2000) Changes in anterior chamber depth and angle width after filtration surgery: a quantitative study using ultrasound biomicroscopy. J Glaucoma 9 (1): 51–55PubMed
14.
go back to reference Nemeth J (1990) The posterior coats of the eye in glaucoma. An echobiometric study. Graefes Arch Clin Exp Ophthalmol 228:33–35PubMed Nemeth J (1990) The posterior coats of the eye in glaucoma. An echobiometric study. Graefes Arch Clin Exp Ophthalmol 228:33–35PubMed
15.
go back to reference Nemeth J, Horoczi Z (1992) Changes in the ocular dimensions after trabeculectomy. Int Ophthalmol 16(4–5): 355–357 Nemeth J, Horoczi Z (1992) Changes in the ocular dimensions after trabeculectomy. Int Ophthalmol 16(4–5): 355–357
16.
go back to reference Peng SX, Zhou WB (1992) The anterior chamber depth after trabeculectomy. Chung Hua Yen Ko Tsa Chin 28(4):214–216 Peng SX, Zhou WB (1992) The anterior chamber depth after trabeculectomy. Chung Hua Yen Ko Tsa Chin 28(4):214–216
17.
go back to reference Sourdille P, Santiago PY (1999) Optical coherence tomography of macular thickness after cataract surgery. Cataract Refract Surg 25(2):256–261 Sourdille P, Santiago PY (1999) Optical coherence tomography of macular thickness after cataract surgery. Cataract Refract Surg 25(2):256–261
18.
go back to reference Stamper RL, McMenemy GM, Lieberman MF (1992) Hypotonous maculopathy after trabeculectomy with subconjunctival 5-fluorouracil. Am J Ophthalmol 114:544–553PubMed Stamper RL, McMenemy GM, Lieberman MF (1992) Hypotonous maculopathy after trabeculectomy with subconjunctival 5-fluorouracil. Am J Ophthalmol 114:544–553PubMed
19.
go back to reference Trier HG (1983) Ocular tissue characterization by RF-signal analysis: results and experience of a 4 year in vivo-study. Ultrasound Med Biol [Suppl 2]:157–161 Trier HG (1983) Ocular tissue characterization by RF-signal analysis: results and experience of a 4 year in vivo-study. Ultrasound Med Biol [Suppl 2]:157–161
20.
go back to reference Vogel A (2001) Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability. J Cataract Refract Surg 27(12):1961–1968CrossRefPubMed Vogel A (2001) Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability. J Cataract Refract Surg 27(12):1961–1968CrossRefPubMed
Metadata
Title
Changes in macular thickness and depth of anterior chamber in patients after filtration surgery
Authors
Gulsara Karasheva
Winfried Goebel
Thomas Klink
Wolfgang Haigis
Franz Grehn
Publication date
01-03-2003
Publisher
Springer-Verlag
Published in
Graefe's Archive for Clinical and Experimental Ophthalmology / Issue 3/2003
Print ISSN: 0721-832X
Electronic ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-003-0628-6

Other articles of this Issue 3/2003

Graefe's Archive for Clinical and Experimental Ophthalmology 3/2003 Go to the issue